• Title/Summary/Keyword: 냉각튜브

Search Result 68, Processing Time 0.021 seconds

Experimental Investigation of Steam Condensation Heat Transfer in the Presence of Noncondensable Gas on a Vertical Tube (수직 튜브 외벽에서의 증기-비응축성 기체 응축 열전달 실험 연구)

  • Lee, Yeon-Gun;Jang, Yeong-Jun;Choi, Dong-Jae;Kim, Sin
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.42-50
    • /
    • 2015
  • To evaluate the heat removal capability of a condenser tube in the PCCS of an advanced nuclear power plant, a steam condensation experiment in the presence of noncondensable gas on a vertical tube is performed. The average heat transfer coefficient is measured on a vertical tube of 40 mm in O.D. and 1.0 m in length. The experiments covers the pressures of 2-4 bar, and the mass fraction of air ranges from 0.1 up to 0.7. From the experimental results, the effects of the total pressure and the concentration of air on the condensation heat transfer coefficient are investigated. The measured data are compared with the predictions by Uchida's and Tagami's correlations, and it is revealed that these models underestimate the condensation heat transfer coefficient of the steam-air mixture.

Analysis on Fluid Dynamics in the Cooling Tube for Manufacture of Liquid Hydrogen (액체수소 제조를 위한 냉각튜브 내 유동장 해석)

  • LEE, DAE-WON;NGUYEN, HOANG HAI;NASONOVA, ANNA;OH, IN-HWAN;KIM, KYO-SEON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.4
    • /
    • pp.301-307
    • /
    • 2015
  • We present a study of hydrogen liquefaction using the CFD (Computational Fluid Dynamics) program. Liquid hydrogen has been evaluated as the best storage method because of high energy per unit mass than gas hydrogen, but efficient hydrogen liquefaction and storage are needed in order to apply actual industrial. In this study, we use the CFD program that apply navier-stokes equation. A hydrogen is cooled by heat transfer with the while passing gas hydrogen through Cu tube. We change diameter and flow rate and observe a change of the temperature and flow rate of gas hydrogen passing through Cu tube. As a result of, less flow rate and larger diameter are confirmed that liquefaction is more well. Ultimately, When we simulate the hydrogen liquefaction by using CFD program, and find optimum results, it is expected to contribute to the more effective and economical aspects such as time and cost.

The effect of the number of nozzle holes on the energy separation (보텍스튜브의 노즐홀수가 에너지분리에 미치는 영향)

  • 유갑종;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.692-699
    • /
    • 1999
  • The vortex tube is a sample device for separating a compressed gaseous fluid stream into two flows of high and low temperature without any chemical reactions. The phenomena of energy separation through the vortex tube were investigated experimentally, to see the effects of the number of nozzle holes on the energy separation. The experiment was carried out with the number of nozzle holes from 1 to 10 by varying inlet pressure and cold mass fraction. The experimental results were indicated that the effective number of nozzle holes for the best cooling performance was found as 4. Also, to find effective use in a given operation conditions, the temperature difference of cold air and the cooling capacity of vortex tube was compared. The result is that cooling capacity was more important than temperature difference of cold air.

  • PDF

Performance Development of the Silencer for a Vortex Tube (볼텍스 튜브용 소음기 성능 개발)

  • Jo, Young-Ho;Kim, Chang-Su;Park, Sung-Young
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.659-661
    • /
    • 2012
  • 볼텍스 튜브란 압축가스의 흐름을 뜨거운 공기와 차가운 공기로 전환 시켜주는 냉각 장치이다. 본 논문에서는 볼텍스 튜브에서 발생되는 소음의 특성을 파악하고자 하였다. 1/2in 소음기와 3/8in 소음기는 소음기를 장착하지 않은 경우 보다 평균8~10dB 감소되었고, 1/4in 소음기는 약15dB정도 감소하였다. 출구를 가공한 1/2in 소음기의 소음은 소음기를 장착하지 않은 경우와 비슷하고 3/8in 소음기는 소음 감소폭이 적었다. 1/4in 소음기기의 소음은 압력이 커질수록 소음이 급격히 커지는 것을 알 수 있다. 기존의 소음기와 출구를 가공한 소음기를 비교 하였을 경우 1/2in 소음기에서는 평균 9dB정도 기존 소음기의 성능이 좋고, 3/8in 소음기에서는 평균 7.5dB정도 성능이 좋은 것을 알 수 있다. 1/4in 소음기에서는 평균 9.5dB정도 기존 소음기가 소음 감소폭이 크며 압력에 따른 소음의 감소폭이 차이가 큰 것을 알 수 있다.

  • PDF

A Quality Stability Estimation of Shock-absorber Tube for automatic drawer (자동서랍함용 완충기 튜브의 품질 안정성 예측)

  • Son, Jae-Hwan;Kim, Young-Suk;Han, Chang-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.7
    • /
    • pp.2919-2924
    • /
    • 2011
  • The automatic drawer is used to absorb the movement shock and adjust its velocity when it opens and closes. The tube in shock-absorber is the cylindrical case which surrounds its parts and is made of acetal. The purpose of this study is to determine the quality stability of the tube in the shock-absorber in injection molding process. The tube which had been manufactured in the process with 4 cavity cooling unit was used. In this study, the analysis and test are carried out to determine its quality stability. Which are the quality analysis with numerical simulation and performance tests of the tube compared with one of foreign make. It is calculated that the injection press is 87.6 MPa and the deflections in X, Y, Z directions are ranged in 0.07~1.00 mm. When the researched tube is compared with the foreign made tube, the maximum bending compressive load is 231 kgf higher, average axial compressive load is 0.05 kgf higher, and the roughness(Ra) on the inner surface is $0.02\;{\mu}m$. lower. In the result, it is known that the quality of researched tube in injection mold process is stable and its performance is superior.

홍조류 김 사상체의 동결보존

  • 조영현;강성필;최성제;서태호;신종암
    • Proceedings of the Korean Aquaculture Society Conference
    • /
    • 2003.10a
    • /
    • pp.118-118
    • /
    • 2003
  • 홍조류 김속 해조 5종(모무늬돌김, 방사무늬김, 참김, 긴잎돌김, 잇바디돌김)의 사상체를 2단계 냉각법으로 액체질소 중에서 동결보존을 시행하였다. 시료를 여러 가지 동해보호제에 현탁시킨 후 프로그램 냉각기로 4시간에 걸쳐 -4$0^{\circ}C$까지 천천히 동결시켰다. 일차 완만동결 종결 후 즉시 동결용 튜브를 액체질소 중에 수용하여 급속동결 시켰다. 해동시에는 4$0^{\circ}C$의 항온수조에서 대부분의 얼음 결정을 급격히 해동시킨 후 냉각수내에서 완전히 해동시켰다. 생존률은 김 속 해조에서는 neutral red로 염색하여 산정하였으며 50% 해수에 10% DMSO와 0.5M sorbitol 혼합액을 동해보호제로 사용하였을 때의 생존율이 54.6~70.9%였다.

  • PDF

Evaluation of Thermal Fluid Characteristics for EGR Cooler with Spiral Type (Spiral 구조 EGR Cooler의 열유동 특성 평가)

  • 허형석;원종필;박경석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.6
    • /
    • pp.44-50
    • /
    • 2003
  • Cooled EGR is an effective method for the reduction of NOx from a diesel engine and an EGR Cooler is the key component of the system. High efficiency, low pressure loss and compactness are required for the EGR Cooler. To meet these requirements, new geometric tube must be developed. In this paper, a full size EGR cooler test bench has been developed to validate the CFD flow and heat transfer models. Fluid temperature and pressure drop measurements are provided. fillet temperature is $200^{\circ}C$ and $300^{\circ}C$, and flow rates vary from 0.008 kg/sec to 0.019 kg/sec. The gas flow and heat transfer in a single tube cooler have been studied using computational fluid dynamics(CFD). Analysis has been carried out in a single tube with a plain tube and six spirally enhanced tubes of varying pitch to depth ratio(p/e).

Improvement of Position Tacking Performance of Magnetostrictive Actuator Using Compressed Air Cooling (압축 공기 냉각을 이용한 자기 변형 액추에이터의 위치 추종 성능 향상)

  • Kwak, Yong-Kil;Hwang, Jin-Dong;Kim, Churl-Min;Kim, Sun-Ho;Ahn, Jung-Hwan
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.4
    • /
    • pp.51-56
    • /
    • 2007
  • Precision positioning system with magnetostrictive actuator(MA) has widely used in manufacturing devices to control the positioning accuracy to meet the high load and stroke requirements. It has many advantage in comparison with piezoelectric actuator; high force, high strain, high efficient etc. But, the performance of Terfenol-D, the commercially available magnetostrictive material, is highly dependent on the prestress, magnetic field intensity and temperature. This paper present an experimental investigation of the temperature effect on displacement characteristics of magnetostrictive actuator. In this paper, compressed cold air is proposed to improve of positioning accuracy of magnetostrictive actuator. The compressed cold air cooling system has good cooling effect Experimental results confirming the effectiveness of the proposed cooling system as high precision positioning system are also has presented in this paper.

A Study on Thermal Analysis for Magnetostrictive Actuator Using Compressed Air Cooling (압축 공기 냉각을 이용한 자기 변형 구동기의 열해석에 관한 연구)

  • Kwak, Yong-Kil;Mostofa, G.;Hwang, Jin-Dong;Kim, Sun-Ho;Ahn, Jung-Hwan
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.4
    • /
    • pp.388-394
    • /
    • 2009
  • Precision positioning system with magnetostrictive actuator(MA) has widely used in manufacturing devices to control the positioning accuracy to meet the high load and stroke requirements. It has many advantage in comparison with piezoelectic actuator; high force, high strain, high efficient etc. But, the performance of Terfenol-D, the commercially available magnetostrictive material, is highly dependent on the prestress, magnetic field intensity and temperature. Therefore, thermal strain of magnetostrictive material obstructs precision position control of magnetostrictive actuator, magnetostrictive actuator is need of cooling system. In this paper, cooling system using compressed cold air is developed and proper temperature and velocity of compressed cold air is studied by thermal analysis according to applied current.

  • PDF

Thermal Effect of a Diode Side-Pumped Yb:YAG Laser Using a Diffusive Reflector (난반사체를 이용한 다이오드 횡여기 Yb:YAG 레이저의 열유도 효과 연구)

  • 이성만;김선국;윤미정;문희종;김현수;고도경;차병헌;이종민
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.46-47
    • /
    • 2001
  • 난반사체를 이용한 다이오드 횡여기 Yb:YAG 레이저에서 레이저 결정의 반경과 레이저 결정의 도핑 농도 등을 매개변수로 하여 이들 매개변수의 변화가 열초점거리에 미치는 영향을 분석해 보았다. 이 때 결정의 굴절률은 1.826, 결정의 투과율은 90%, 결정의 길이는 10mm로 하였으며, 냉각수의 굴절률은 1.33, 냉각튜브의 두께는 1.5 mm로 하였다. 또 렌즈를 통과한 황선의 divergence는 5도, 난반사 공동체의 반사율은 95.7%로 계산하였다. 다이오드의 전체 출력은 600 W이다. 펌프헤드의 구조도를 그림1에 보였다. (중략)

  • PDF