• 제목/요약/키워드: 냉각유

Search Result 210, Processing Time 0.025 seconds

Optimization of the Scraper Speed and Improvement of the Refrigerant Path for the Evaporator of the Soft Ice Cream Machine (소프트 아이스크림 제조기 증발기의 스크레이퍼 회전수 최적화 및 냉매 유로 개선)

  • Baek, Seung-Hyuk;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.8-14
    • /
    • 2017
  • Improvements in the standard of living and lifestyle have led to increased sales of frozen milk products, such as soft ice cream or slush. These frozen milk products are commonly made in a small refrigeration machine. In a soft ice cream machine, the freezer is composed of a concentric cylinder, where the refrigerant flows in the annul us and the ice cream is made in the cylinder by a rotating scraper. In this study, an optimization and performance evaluation were conducted on a soft ice cream machine having a freezer volume of 2.8 liters. The optimization was focused on the scraper rotation speed and the refrigerant path of the freezer. The measurements included the temperature, pressure and consumed power. At the optimized speed of 124 rpm, ice cream was produced in 6 minutes and 2 seconds, and the COP was 0.90. Through a flow visualization study using air-water, the refrigerant path was improved. The improved design reduced the ice cream making time significantly. The present results may be used for the optimization of other refrigeration cycles, including those of frozen food products.

A Study on Heat Transfer Enhancement of Oil Cooler (유냉각기의 열전달 촉진에 관한 연구)

  • Cho, D.H.;Lim, T.W.
    • Journal of Power System Engineering
    • /
    • v.15 no.3
    • /
    • pp.25-30
    • /
    • 2011
  • A shell-and-tube oil cooler with plate fins was suggested to improve the defect of the conventional shell-and-tube oil cooler. Experiments were conducted to evaluate the heat transfer performance on the shell side of shell-and-plate finned tube oil cooler with three different tube numbers(9, 13 and 19). Oil flowing on the shell side was cooled by cold water flowing inside the tubes. A shell-and-tube heat exchanger of an oil cooler consisted of one shell pass and two tube passes with the inner tube diameter of 8.82 mm and the tube length of 575 mm. From the experiment of shell-and-tube oil cooler, it was found that the heat transfer coefficient of oil cooler with 9 tubes, as oil flow rate was increased, was approximately 140% and 250% higher than that of 13 and 19 tubes, respectively. The heat transfer coefficient at the water flow rate of $3m^3/h$, also was 120% and 140% higher than that of 2.4 and $1.8m^3/h$, respectively.

The effect of dilution solvent ratio on dewaxing of waxy oils (Waxy Oil 탈납에 있어서 용제희석의 영향)

  • 김주항
    • Tribology and Lubricants
    • /
    • v.3 no.2
    • /
    • pp.34-43
    • /
    • 1987
  • The effect of dilution solvent ratio, and the mixing ratio of MEK and toluene on the solvent dewaxing process has been studied. The results of this study are Summarized as follows; 1. The best mixing ratio of solvent of MEK process and Toluene when in case of light and medium Waxy oils, which has low viscosity was 48: 52, and when in case of heavy waxy oil, which has high viscosity was 45: 55. 2. The best dilution solvent ratio when in case of low viscosity oils. was 1:2.8 against waxy oils after annexing 5 times divided as well as, when incase of high viscosity oil was 1:3.5 after annexing 2 times divided. 3. The chilling temperature was -26$\circ$C and the reguired dewaxing time depends on the viscosity of waxy oils.

Analysis of Anisotropic Turbulent Heat Transfer in Nuclear Fuel Bundles (핵연료 집합체내의 비등방성 난류 열전달에 관한 해석적 연구)

  • Kim, Sin;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • v.20 no.1
    • /
    • pp.35-46
    • /
    • 1988
  • The prediction of clad surface temperatures is important to the design and the safety anlaysis of nuclear reactor. The accurate prediction requires the detailed knowledge of the flow structure and heat transfer, which is complicate due to anisotropic turbulent phenomena. A two-equation model including anisotropic eddy viscosity model is applied to forecast the velocity distribution. And the temperature field is calculated with uniform wall heat flux. The Galerkin's weighted residual finite element method has been used to calculate the turbulent quantities right up to the wall. The numerical results show good agreement with available data and that turbulence anisotropy strongly affects on the mean flow and thus the temperature field. And Nu-P/D correlation is established for sodium coolant in close-packed equilateral triangular bundle in the P/D range of 1.05 to 1.30.

  • PDF

Development of Oil Mist Collector by using Exterior Filtration Method-1 (외면 여과식 오일 미스트 콜렉터의 개발-1)

  • 조진호;김태형;하현철
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.531-532
    • /
    • 2003
  • 공작기계 가동시 윤활과 냉각 등의 목적으로 다양한 종류의 금속가공유 (MWFs : 절삭유, 윤활유, 방청유 둥)를 사용하고 있다. MWFs에는 포름알데히드, 니트로스아민, 염화파라핀 등의 발암물질이 포함되어 있는 것으로 알려져 있어 작업자 건강보호를 위해 효율적인 환기가 요구되고 있다. 현장에서 가장 많이 사용하고 있는 포켓 필터형 오일미스트 콜렉터는 제진 장치가 없기 때문에 필터 표면에 한번 부착된 오일 미스트와 먼지가 떨어지지 않기 때문에 일정시간 후 필터 표면에 막힘 현상이 발생한다. 필터 표면이 막히면 차압 증가와 함께 송풍량이 감소하기 때문에 미스트 제거 효율이 크게 저하되고, 결과적으로 오일미스트의 환기 효율이 크게 감소된다.(중략)

  • PDF

Performance Analysis of Hybrid SOFC/Uncooled GT System for Marine Power Applications (선박동력용 SOFC/GT(무냉각) 하이브리드시스템의 성능 평가)

  • Kim, Myoung-Hwan;Kil, Byung-Lea
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.8
    • /
    • pp.1050-1060
    • /
    • 2012
  • As an approach to high-efficiency of SOFC system, SOFC/GT Hybrid system is effective. However, if the output size of the system belongs to the marine class of dozens MWs, the introduction of the cooling system of GT system, which is used as sub-system, makes its related devices complicated and also makes its control difficult. Accordingly, for the marine use, SOFC/GT (non-cooling)Hybrid system looks more suitable than SOFC/GT(cooling)Hybrid system. This study established the SOFC/GT (non-cooling)Hybrid system, and examined the operating temperature & current density of the stack for the system, pressure ratio of the gas turbine, the influence of TIT(Turbine Inlet Temperature) on system performance, etc. through the simulation process. Through this research process, this study was able to confirm that electrical efficiency rises in spite of the increase in the required power for the air compressor, and there exists a limited range of temperatures for operation in TIT.

Optimized Brazing Conditions of Regenerative Cooling Thrust Chambers (재생 냉각용 연소기의 최적 브레이징 조건)

  • Nam,Dae-Geun;Hong,Seok-Ho;Han,Gyu-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.7
    • /
    • pp.112-117
    • /
    • 2003
  • The brazing of copper alloys and duplex stainless steels is an indispensable manufacturing technology for thrust chambers with regenerative cooling. For setting up the optimized brazing conditions, C18200 copper alloy plate with machined cooling channels and S31803 stainless steel plate are brazed with AMS4764 filler metals of which thickness is 50${\mu}m$ and 80${\mu}m$ They are tested by X-ray radiography, strength/leakage and fracture tests, and fracture surface inspection. The results obtained by the suggested conditions are that the specimen brazed with filler metal thickness of 50${\mu}m$ has good strength properties and brazed zone. However, the specimen with filler metal thickness of 80${\mu}m$ has the brazed zone with cooling channel obstruction and enlargement.

A study on performance comparison of jacket cooling fresh water system for marine diesel engine (선박용 디젤기관의 재킷 냉각청수시스템 성능 비교에 관한 연구)

  • Kim, Duk-Kyung;Lee, Jae-Hyun;Cho, Kwon-Hae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.8-14
    • /
    • 2017
  • Due to the financial crisis in 2008, the world economy collapsed leading to an increase in oil prices and a decrease in freight by shipping. To overcome this crisis, major shipping companies ordered larger ships, changed their trading route and improved operating of ships to overcome deficits. In particular, low-speed navigation was much favored by many companies so that it can reduce fuel consumption. However, the long-term operation of high-speed optimized engines in low-speeds has affected the jacket cooling fresh water (J.C.F.W.) system as they fail to maintain the normal operational temperature. The temperature of J.C.F.W. system dropped leading to low temperature corrosion. As a result, when the engine is operating at minimal load the functioning of existing J.C.F.W cooler is decreased and the use of fresh water generator is substantially limited. Therefore, an improvement in the functioning of J.C.F.W. system is necessary. In this paper, in order to review the improvements required for the operation of J.C.F.W. of low-speed operating marine diesel, an experiment was conducted by comparing and analyzing the results of the main engine J.C.F.W. system of a Panamax class bulk carrier 82k and a Cape class bulk carrier 180k by installing and uninstalling the J.C.F.W. Cooler. Thus, this paper proposed an improved design of the J.C.F.W. system that is suitable for the present low-speed operation.

Development of Low Pollution Grinding Technology using Mist (Mist를 이용한 저공해 연삭 가공기술 개발)

  • 최헌종;이석우;김대중;정해도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.793-797
    • /
    • 2000
  • The environmental problems by using coolant demanded the new cooling methods. As one of them the studies on the dry grinding with compressed cold air have been done. The cooling method using compressed cold air was effdve thmugh going down the temperature of compressed air supplied below $-25^{\circ}C$ and inneasing the amount of mmpresd cold air, but had not enough cooling effect due to the low performance of lubrication. Therefore, the cooling methods using MQL(Minimum Quantity Lubrication) or mist newly were suggested. These two methods can satisfy both cooling effect and lubrication with only small amount of coolant, also has the benefit in the point of decreasing the envimnmental pollution. This paper focused on analyzing the grindmg characteristics of the cooling method using mid. The generated heat and grinding force of the cooling method using mist were compared with them of coolant and compressed cold air. And them grinding test according to the temperature of compressed cold air, mist spray amount and mist supply direction were done.

  • PDF