  • The purpose of this study was to develop the production technology of modified starch. Corn starches were gamma irradiated at 0-110 kGy and the effect of irradiation dose levels on the physicochemical properties of corn starches were investigated. Blue value linearly decreased, while alkali number and solubility markedly increased as irradiation dose levels were increased. The optical transmittance increased as applied irradiation dose levels were increased in the temperature range of $65-95^{\circ}C.$ Water binding capacity and swelling power showed maximum value at 30 and 10 kGy, respectively and they tended to decrease thereafter. Gelatinization viscosity of the gamma irradiated starch considerably decreased as compared to that of the non-irradiated starch. Irradiation at 110kGy resulted in a marked reduction of peak viscosity and cooling viscosity at $30^{\circ}C$ by 100 and 300 times, respectively. The physicochemical properties of corn starch irradiated at 30 kGy were similar to those of commercial acid-modified starch, while those of corn starch irradiated at 100 kGy were similar to those if oxidized starch.

  • PDF

Field Loss Analysis and Cooling Analysis of HTS Synchronous Motor (고온초전도 동기모터의 계자손실 해석 및 냉각 해석)

  • Kim, Ki-Chan;Lee, Dae-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.69-74
    • /
    • 2018
  • Large industrial motors require a large area because of the high risk of shutdown accidents and large industrial accidents due to the lowering of the dielectric strength of the armature windings and overheating problems. Therefore, there is a demand for a large-capacity motor that has small size, light weight, and excellent dielectric strength compared with conventional motors. Superconducting motors have advantages of high efficiency and output power, low size, low weight, and improved stability. This results from greatly increasing the magnetic field generation by using superconductive field coils in rotating machines such as generators and motors. It is very important to design and analyze the cooling system to lower the critical temperature of the wires to achieve superconducting performance. In this study, a field loss analysis and low-temperature heat transfer analysis of the cooling system were performed through the conceptual design of a 100-HP high-temperature superconducting synchronous motor. The field loss analysis shows that a uniform pore magnetic flux density appears when high-temperature superconducting wire is used. The low-temperature heat transfer analysis for gaseous neon and liquid neon showed that a flow rate of 1 kg/min of liquid neon is suitable for maintaining low-temperature stability of the high-temperature superconducting wire.

Development of Large Diameter Hardfacing FCW for Life Extension of Hot Forging Die (열간단조 금형 수명연장을 위한 경화육성용접용 태경 FCW의 개발)

  • Kim, Sung-Ho;Jung, Yun-Ho;Baek, Seung-Hui;Jang, Jong-Hun;Park, Chul-Gyu;Woo, Hee-Chul;Jung, Byung-Ho;Cho, Sang-Myung
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.13-13
    • /
    • 2009
  • 현재 열간단조 금형을 제작함에 있어 육성용접을 실시하는 방법이 금형강 STD61, STD11 등으로 제작하는 방법에 비해 보수나 비용적인 측면에서 이점을 가지고 있기 때문에 점차적으로 증가하고 있는 추세이다. 열간단조 공정에서 금형은 $1000^{\circ}C$이상의 고온재료와 반복접촉하게 된다. 이때 이형제의 사용은 급속냉각 및 급속가열의 열피로를 가속시킨다. 또한, 금형은 반복충격에 의한 기계적 피로를 받게 된다. 이러한 금형의 사용환경을 고려한 FCW는 종래 고가의 $2.8{\sim}3.2{\Phi}$인 외국산 FCW를 사용하였으나 이를 대체한 $3.2{\Phi}$ 태경 FCW가 국내에서 개발되었다. 하지만 개발된 FCW를 사용하여 제작된 금형의 수명이 부족한 현상이 발생하였다. 이에 금형의 수명을 연장시킬 수 있는 내균열성 및 내열충격성을 확보한 태경 FCW의 개발과 개발된 FCW의 성능평가가 요구되었다. 특히 열간단조 금형에 있어서 중요한 내열충격성의 경우 가열과 냉각의 반복 Cycle에 의한 Thermal shock의 평가가 대부분이며 높은 Cycle로 인해 많은 시간이 걸리며, 또한 가열과 냉각을 오갈 수 있는 고가의 시험장치가 요구된다. 그러므로 개발된 FCW 육성용접부의 내균열성 및 내열충격성을 평가할 수 있는 방법에 대한 연구와 특히 내열충격성을 시간이 적게 걸리면서도 경제적으로 평가할 수 있는 방법에 대한 연구가 필요하다. 본 연구의 목적은 열간단조 금형 육성용접부의 내균열성 및 열충격특성을 평가할 수 있는 방법에 대한 검토와 특히 내열충격성에 대해 J.W.Kim등의 시험방법을 참고하여 시간이 적게 걸리면서 저 비용으로 열 충격특성을 평가할 수 있는 시험법을 고안하는 것이다. 이를 위한 방법으로 육성용접부의 내균열성을 평가하기 위한 상온 Bending을 실시하였고, 내열충격성을 평가하기 위한 염욕로를 이용하는 고온 Bending을 고안하여 실시하였다. 상온 Bending, 고온 Bending 모두 3점 굽힘시험을 적용하였다. 고온 Bending의 가열방법으로는 염욕로를 사용하여 시편이 대기중에서 약 $850^{\circ}C$의 온도가 될 수 있도록 하였다. 시편은 각각 열처리를 하여 요구 경도를 확보하였고, 이를 염욕로에서 5분간 가열 및 유지하여 취출 후 굽힘하중을 가하여 변위의 정도로 열충격을 평가하는 방법을 사용하였다. 상온 Bending은 극한변형량과 파단부 극한응력으로, 고온 Bending은 고온 극한변형량으로 평가를 하였고, 외국산 FCW를 사용한 육성용접부를 비교대상으로 하였다. 평가 결과 개발된 국산 $3.2{\Phi}$ 태경 FCW의 성능은 외국산 FCW와 유사하거나 우수한 것으로 평가되었고, 실제 금형을 제작하여 현장에 적용한 결과 금형의 수명이 연장된 것이 나타났다.

  • PDF

Satellite Thermal Control Device Enhanced by Latent Heat of the Phase Change Material (응고/융해 잠열을 이용한 위성용 열제어장치의 실험적 연구)

  • Kim, Tae Su;Shin, Yoon Sub;Kim, Taig Young;Seo, Jung-gi;Hyun, Bum-Seok;Cheon, Hyeong Yul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.10
    • /
    • pp.887-894
    • /
    • 2016
  • The thermal control device using solid-liquid phase change material (PCM) is designed, manufactured, and experimented in thermal environment chamber. The n-Hexadecane is selected as a PCM and its melting point is placed within the component working temperature range. The PCM container is made of Al6061 and has the thermal spreading fins inside. To simulate the working condition for on-orbit satellite the heat pipes are used to connect the heater and radiator and the PCM thermal control device (PCMTD) is installed at the middle portion of heat pipes. The thermal buffer mass (TBM), which is same configuration and volume with PCMTD, is also manufactured to compare the thermal control performance. As a result, the PCMTD is not only more efficient than TBM in their temperature control features but both mass and power of compensation heater are reduced.

The Throughflow Effects on Natural Convection in Horizontal Porous Layer (수평 다공층에서 수직 관통류가 자연대류 열전달에 미치는 영향에 관한 연구)

  • 서석진
    • Journal of Energy Engineering
    • /
    • v.7 no.2
    • /
    • pp.209-215
    • /
    • 1998
  • This paper investigated the vertical throughflow effects on natural convection due to heating from below in horizontal porous layer. The motion of the fluid in the porous layer is governed by Brinkman-Darcy equation. And compared Critical Rayleigh number in case of throughflow with no throughflow. Investigated Nusslet number, isothermalline and flow with the variation of the strength of throughflow in a constant Rayleigh number. In the numerical analysis, flow is assumed to be two-dimensional and unsteady. The numerical scheme used is a finite-difference method. In the experimental study, Temperature distribution was measured by use of Liquid Crystal film. As a results, indicated that throughflow influences largely on the temperature field and as the strength of throughflow increased, unstability of natural convection decreased. Also it could predict the strength of natural convection with the measured Nusselt number.

  • PDF

Heat Transfer Characteristics in the Evaporator of a Soft Ice Cream Maker (소프트 아이스크림 제조기 증발기의 전열 특성)

  • Byun, Ho-Won;Lee, Jin-Wook;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1466-1473
    • /
    • 2012
  • Soft icecream is made by scraping an ice formed on the inside of the cylindrical evaporator, where R-404A is evaporating in the annulus. The heat transfer characteristics of the refrigerant evaporation and those during icecream formation were experimentally investigated. Results show that the refrigerant-side heat transfer coefficients are highly dependent on the location in the evaporator due to the complex annulus configuration. The heat transfer coefficient at the inlet is generally lower than those of other locations. The average heat transfer coefficient increases as heat flux increases or saturation temperature decreases. A correlation is developed to predict the refrigerant-side heat transfer coefficient. The icecream-side heat transfer coefficient oscillates continuously due to the periodic removal of ice formed on the surface. The average heat transfer coefficient during icecream formation is approximately 280 W/$m^2K$, and that during single-phase cooling increased from 150 W/$m^2K$ to 250 W/$m^2K$.

Fire-Retardation Properties of Silicone/Perlite Composites (실리콘/펄라이트 복합체의 난연 특성)

  • Lee, Byunggab;Won, Jongpil;Jang, Ilyoung;Bang, Daesuk
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.154-154
    • /
    • 2011
  • 최근 세계 각지에서 발생하는 대규모 터널 화재사고는 많은 사상자를 동반하고 이에 따른 경제적, 사회적 손실 또한 방대하게 진행되는 실정이다. 터널 구조물의 화재 특성상 외부에 쉽게 노출되지 않기 때문에 화재 발생 시 화재에 노출된 표층이 박리되거나 비산해서 단면결손이 생기는 폭렬 현상(explosive spalling)이 발생하게 된다. 이러한 폭렬 현상은 붕괴와 같은 대형 참사로 이어질 가능성이 크다. 따라서 본 연구에서는 터널 내 화재 발생 시 콘크리트 구조물의 폭렬에 의한 붕괴를 예방하기 위하여 이액형 상온경화 실리콘 고무와 인체에 무해한 친환경 첨가제인 펄라이트를 일정한 혼합비(5wt%, 10wt%, 15wt%, 20wt%)로 혼합하여 고성능 난연 복합체를 제조하고, 열적 특성과 난연 특성을 연구를 진행하였다. 열적 특성에 관한 시험으로 TGA를 측정하였으며, 난연 특성에 관한 시험으로는 화염 시험, 내화로 시험, 탄화로 시험을 진행하였다. 우선 TGA 시험은 $20^{\circ}C/min$ 승온 속도로 $800^{\circ}C$까지 실험을 하였고, 화염 시험은 제작한 시편과 gas torch($1200^{\circ}C$)의 화염 거리를 약 10cm로 하여 약 1시간 동안 시험을 하였다. 내화로 시험은 내화로 장치를 이용하여 RABT curve(5분만에 $1200^{\circ}C$도달 후 한 시간 동안 유지 후 냉각, 총 시험 시간 180분) 조건을 만족하는 환경에서 제작한 시편을 콘크리트에 부착하여 콘크리트의 내부온도를 측정하였다. 탄화로 시험은 탄화로 장치를 이용하여 $2^{\circ}C/min$ 승온속도로 $900^{\circ}C$까지 실험을 하여 외부 형태 변화를 관찰하였다. 각각의 시험 결과 TGA 열분해 결과 순수한 실리콘 고무보다 난연제인 펄라이트를 첨가했을 때 더 높은 온도에서 초기 분해 거동을 보였으며, 최종 잔류량은 80%를 보였고, 5 wt%의 펄라이트가 혼합된 시편의 최종 잔류량이 높은 것으로 보아 열분해에 가장 강한 조성임을 알 수 있었다. 화염 시험 결과 펄라이트가 혼합된 모든 시편에서 $300^{\circ}C$가 넘지 않은 결과를 보였다. 이는 제조된 복합체가 화염에 직접적으로 장시간 노출이 되어도 안전하다는 것을 알 수 있다. 내화로 및 탄화로 시험 결과 펄라이트가 15wt%와 20wt%가 첨가된 시편들보다 5wt%와 10wt% 첨가된 시편들이 고온에서 안정하다는 것을 보였다.

  • PDF

Development of control and monitoring board for building energy saving valve (빌딩 에너지 절감 밸브용 제어 및 감시 보드 개발)

  • Oh, Jin-Seok;Kang, Young-Min;Jang, Jae-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.6
    • /
    • pp.895-902
    • /
    • 2018
  • Energy consumption in buildings is close to 40% of the total national energy consumption in developed countries such as US and Japan, and Korea accounts for 24% of total energy consumption. In buildings, HVAC can't freely control the cooling flow rate according to the required calorie, so energy is not used efficiently. Therefore, by using the energy saving valve, the flow rate can be controlled by the required amount of heat and the energy can be saved. In this paper, we define basic conditions and develop control and monitoring boards for building energy saving valves based on PIC processor with low power and high cost-effectiveness. The designed board displays and transmits in real time information about two temperature values, flow values and calculated calories for temperature difference measurement. The developed board will be useful for real - time monitoring of the state of the valve in the future and development of the valve for the offshore.

Determination of the Nucleation Rate Curve for Lead Titanate in the PbO-TiO$_2$-B$_2$O$_3$-BaO by Diffferential Thermal Analysis (PbO-TiO$_2$-B$_2$O$_3$-BaO 계 유리에서 PbTiO$_3$ 결정의 핵생성 곡선 결정을 위한 열시차분석법의 응용)

  • 이선우;심광보;오근호
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.6
    • /
    • pp.640-646
    • /
    • 1998
  • Nucleation and crystallzation of a quaternary glass system for lead titanate glass-ceramics were in-vestigated using DTA(differential thermal analysis ) with variation of nucleation temperature and crystal growth time. Glass samples containing 60mol% of PbO-{{{{ { TiO}_{2 } }} were prepared from melts by the conventional normal cooling method in a cylindrical brass mould. The glass sample was nucleated between 40$0^{\circ}C$ and 50$0^{\circ}C$ for a given time and showed the maximum nucleation rate at 46$0^{\circ}C$ The DTA crystallization peak temperature decreased with increasing nucleating time and decreasing heating rate during DTA runs which indicated an increase of the number of nuclei produced in the system.

  • PDF

Design Point Operating Characteristics of an Oxidizer Rich Preburner (산화제 과잉 예연소기 설계점 운영 특성)

  • Moon, Ilyoon;Moon, Insang;Kang, Sang Hun;Ha, Seong-Up;Lee, Soo Young
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.4
    • /
    • pp.81-88
    • /
    • 2013
  • It was designed and tested at the design point that an oxidizer rich preburner for a staged combustion liquid rocket engine propelled by kerosene and LOx. The oxidizer rich preburner was designed as some of LOx injected from the mixing head was burned with kerosene and the rest of LOx injected from injection holes in the regenerative cooling chamber was vaporized by combustion gas. The preburner is operated at OF ratio of 60 and combustion pressure of 20 MPa. The Preburner has a honey-comb type mixing head with simplex swirl injectors, a turbulence ring improving combustion stability and uniformity of product gas temperature distribution, and a nozzle simulating the duct. With the combustion test results at the design point, the oxidizer rich preburner showed high combustion stability and uniformity of product gas temperature distribution.