• Title/Summary/Keyword: 냉각수 부족

Search Result 15, Processing Time 0.023 seconds

A Study on Sensing Method of the Stack Coolant Deficiency for FCEV (연료전지 차량 스택 냉각수 부족 감지 방법에 관한 연구)

  • Kim, Hyung Kook;Han, Su Dong;Nam, Gi Young;Kim, Chi Myung;Park, Yong Sun
    • Journal of Hydrogen and New Energy
    • /
    • v.25 no.5
    • /
    • pp.525-532
    • /
    • 2014
  • The sensing of a stack coolant deficiency is very important in that cooling performance of a fuel cell, overheating prevention of a stack or coolant heater. This paper explains the performance comparison between the coolant contact/noncontact level sensors and coolant deficiency sensing logic using the pressure sensor in a stagnant or circulating flow. Throughout the comparison, the pressure sensor is more suitable than the other sensors in terms of the precision, fast response, sensing frequency. After the experiment, the pressure sensor is equipped to an FCEV(Fuel Cell Electric Vehicle) to verify sensing definitely. There was no miss-sensing using pressure sensor while FCEV runs in the conditions of the paved road and cross country road.

Circuit Capacity of Water Cooling on Domestic Small Diesel Engine (소형(小型)디젤 기관(機關)의 냉각수(冷却水) 순환량(循環量)에 대(對)한 연구(硏究))

  • Kim, Sung Rai;Myung, Byung Soo
    • Korean Journal of Agricultural Science
    • /
    • v.19 no.1
    • /
    • pp.91-96
    • /
    • 1992
  • Diesel engine being used on power tiller has over heating problem while running at the rated power range, The reason for overheating the engine is mainly owing to so small capacity of cooling system. This study was conducted to determine relatively optimum capacity of cooling system for the diesel engine. The results obtained are summarized as follows. 1. The capacity of cooling system for the diesel engine being used in the rural area was not sufficient to cool the engine at the rated power. 2. It is desirable that the cooling water flow rate was $12{\ell}/min$ if we used supplementary pump for increasing the cooling efficiency. 3. As cooling water was circuited $12{\ell}/min$, highest temperature of cooling water was $91^{\circ}C$. This value is within $88^{\circ}C{\pm}5^{\circ}C$ of SAE Standard criterion.

  • PDF

복수기 및 열교환기의 부식과 전기방식법

  • 박현기
    • 전기의세계
    • /
    • v.44 no.4
    • /
    • pp.25-30
    • /
    • 1995
  • 복수기 및 열교환기는 진공증발 등 특수한 것을 제외하면 면적을 크게하여 유속을 부여하고 전도효율을 높이기 위해 금속관을 주체로 하는 다관식이 많다. 냉각수는 다량으로 필요하기 때문에 하수나 지하수보다 질이 떨어지는 공업용수나 해수가 많이 사용되나, 우리나라는 용수 부족등으로 인하여 해안지방에 화력 및 원자력 발전소, 정유공장 및 일반산업체 등이 집중되어 있어 대부분의 경우 해수를 냉각수로 사용하고 있는 실정으로 해수에 의한 심한 부식성으로 tube, tube sheet 및 water box가 빠른 속도로 부식되어 열교환기 이용률을 저하시키며 잦은 고장으로 인한 발전 및 조업중단등의 사고를 야기할 수 있으므로 부식손상등의 종류 및 대책드을 강구하기 위하여 적정 방식법을 논의 하기로 한다.

  • PDF

A Study on Development of Liquid Cooled Plate for Cooling of a Communication Electronic Device with High Heat Generation (고발열 통신용 전자부품 냉각을 위한 고성능 수냉식 냉각판 개발에 관한 연구)

  • Chang, G.;Park, C.M.;Kim, E.P.
    • Journal of Power System Engineering
    • /
    • v.11 no.2
    • /
    • pp.26-31
    • /
    • 2007
  • 통신용 전자기기에서 대부분의 열은 증폭기에서 발생한다. 일반적으로 증폭기를 냉각하기 위하여 공랭식을 사용하여 발생하는 많은 열을 냉각하였다. 그러나 전통적인 방법은 고성능 콤팩트화 되어가는 추세에서 발열되는 열을 충분히 냉각하기는 부족하다. 본 논문은 고발열 전자부품 냉각을 위해서 수냉식 방법을 사용하였다. 열전달 효율을 높이기 위하여 냉각판에 직접 냉각수를 흐르게하여 접촉저항을 줄였다. 그리고 냉각판의 유로에 대한 배열과 유량의 비의 효과를 조사하였다. 연구를 수행한 결과, 다음과 같은 결론을 얻을 수 있었다. 냉각수 순환량이 $3{\iota}/min$인 경우, 유로 직경이 8 mm일 때의 냉각 성능이 10 mm일 때보다 우수한 것으로 나타났다. 냉각수 순환량이 $3{\iota}/min$인 경우, 유로 직경이 8 mm일 때의 발열 소자 표면 온도 분포가 더욱 안정적으로 나타났으며, 상하부에 설치된 발열 소자 표면 온도가 더 낮게 나타났다. 동일한 유로 직경의 냉각판에서, 열유속 증가에 따른 냉각수의 전열 성능 증가로 인해 전체 발열량의 증가율보다 발열 소자의 온도 증가율이 낮게 나타났다.

  • PDF

생물공정의 측정 및 새로운 공정변수의 개발

  • Heo, Won
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.51-52
    • /
    • 2000
  • 생물공정의 운전에 있어서 적절한 공정변수가 부족한 경우가 많다. 이것은 멸균과정을 견딜 수 있는 신뢰성 높은 센서가 부족하기 때문이다[1]. 생물공정에 주로 사용되는 센서로서는 온도, pH, D.O., rpm, viscosoty 등이 있으나 이 센서들은 배양액의 물리적 혹은 화학적 상태를 측정할 수 있는 경우가 대부분이다[2]. 미생물의 대사활동과 관련이 있는 공정 변수로는 배출가스의 성분을 측정하여 얻을 수 있는 Oxygen uptake rate, Carbon dioxide evolution rate 및 Respiratory quotient가 있으며 현재 생물공정의 운전에 사용되고 있다[3]. 그러나 반복적인 센서의 보정과 연결관의 잦은 청소 및 보수를 필요로 하여 제한적으로 사용되고있는 실정이다. 자동화된 습식분석장치, Gas chromatograph, High Performace Liquid Chromatograph 혹은 Mass spectrophtometry 등을 온라인 샘플 처리장치와 연결하여 발효조의 배양액의 성분을 온라인으로 분석하고 공정의 운전에 응용하는 사례가 많이 발표되었다[4-6]. 고가의 장비 및 운전의 번거러움이나 추가적인 인력이 필요하므로 역시 특별한 경우에만 사용되고 있다. 이외에도 여러 종류의 온라인 센서 및 바이오 센서등이 개발되어 사용되고 있으나 역시 그 사용범위는 특수한 영역에 한정되어있다. 이와 같이 새로운 센서를 개발하여 공정변수를 측정하려는 시도중의 하나가 소프트웨어 센서의 개발이다. 이 것은 공정상에서 발생하는 1차 공정변수를 이용하여 배양액의 상태 혹은 2차적인 공정 변수를 추측해내는 것이다. 대부분의 경우 기존의 공정 변수를 사용하므로 추가적인 비용이 들지 않고 소프트웨어의 형태로 구현되므로 센서의 보정과 설치 및 유지관리의 노력이 매우 적은 장점이 있다. 본 연구에서는 생물공정에서 자동제어 과정에서 발생하는 여러 가지 공정상의 제어 신호로부터 새로운 공정 변수를 얻어내고자 시도하였다. 대부분의 생물공정에서는 pH의 자동제어가 필수적인데 자동제어 과정에서 발생하는 pH 제어 신호 및 pH의 변화 응답신호를 이용하여 배지의 완충용량의 변화와 알칼리의 소비속도를 온라인으로 측정할 수 있었다. 여기에 인공지능망을 설계하여 균체의 량을 온라인으로 추정하는 방법을 개발하였다 [7].산업용 발효조의 운전 온도는 주로 냉각수의 단속적인 공급에 의하여 항상 일정하게 조절된다. 따라서 냉각수의 냉각량을 측정하면 미생물의 배양시 발생하는 대사열량을 측정할 수 있게 된다. 본 연구에서는 실험실의 발효조를 냉각수의 단속적인 공급에 의하여 자동온도 조절이 되도록 개조하고 여기에 냉각수의 유출입 지점에 온도센서를 부착하여 냉각수의 온도를 측정하고 냉각수의 공급량과 대기의 온도 등을 측정하여 대사열의 발생을 추정할 수 있었다. 동시에 이를 이용하여 유가배양시 기질을 공급하는 공정변수로 사용하였다 [8]. 생물학적인 폐수처리장치인 활성 슬러지법에서 미생물의 활성을 측정하는 방법은 아직 그다지 개발되어있지 않다. 본 연구에서는 슬러지의 주 구성원이 미생물인 점에 착안하여 침전시 슬러지층과 상등액의 온도차를 측정하여 대사열량의 발생량을 측정하고 슬러지의 활성을 측정할 수 있는 방법을 개발하였다.

  • PDF

Development of a Solar Powered Water Pump by Using Low Temperature Phase Change Material ­ System Construction and Operation Analysis ­ (저온 상변화 물질 특성을 이용한 태양열 물펌프 실용화 연구개발(II) ­시스템 구성 및 작동분석)

  • 김영복;이양근;이승규;김성태;나우정;민영봉
    • Journal of Animal Environmental Science
    • /
    • v.9 no.2
    • /
    • pp.69-78
    • /
    • 2003
  • In this study, the energy conversion equipment from the radiation energy to mechanical energy by using n­pentane as the operating fluid was constructed and the performance to pump the water was tested for the utilization of solar powered water pump. The equipment was designed optimally, after the theoretical analyses of the water pumping head and water quantity per cycle were done. The pentane vapour temperature in the condenser and the temperature of the outlet water from the condenser became lowered and the heat transfer rate became higher with decreasing the water inlet level to the condenser. The temperature difference between the condenser and the water tank was significant. Therefore, the distance between the water tank and condenser was recommended to be shorten and the diameter of their connecting pipe was recommended to be narrow in order to reduce the resistance of the fluid passage and improve the heat transfer rate. The amount of water pumped was 1.6­2.4 liters. Mass flow rate of the cooling water became lowered when the cooling water pipe was prolonged from the condenser to improve the heat transfer rate.

  • PDF

A Trend of Infra Structure Establishment and Method of Performance Evaluation for Cooling Tower (냉각탑 성능평가 방법 및 관련 설비구축 현황)

  • 윤재호;김종하;권오경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.3
    • /
    • pp.405-412
    • /
    • 2004
  • 최근 우리나라의 경제 발전에 따른 산업 규모가 총체적으로 증가함으로써 그에 따른 산업용수의 사용량이 크게 증가하고 있다. 산업용수 사용량의 증가는 제한된 수자원의 부족과 방류 산업용수에 의한 수질오염 등의 문제가 발생하게 된다. 이러한 문제점을 해결하기 위해서는 산업용수중 약70%를 차지하는 각종 냉각수의 재이용이 필요하다.(중략)

Strategy of Water-Energy-Food Nexus to ensure Resources Security (자원안보 확보를 위한 물-에너지-식량 넥서스 추진 전략)

  • Lee, Eul Rae;Choi, Byung Man;Chae, Hyo Sok;Jung, Young Hun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.136-136
    • /
    • 2016
  • 현재 전 세계적으로 지속적인 인구증가와 도시화 및 산업화 영향으로 물, 에너지, 식량의 수요증가와 공급부족이 예상되는 가운데, 급격한 기후변화와 자원고갈로 인해 이는 더욱 가속화되고 심화될 위기에 직면하였다. 특히 물의 수요는 증가하나 공급은 제한되어 있어 지속가능한 인류의 생존을 위하여 인간에게 꼭 필요한 에너지와 식량의 문제를 물을 중심으로 상관성을 찾고 효율적인 물활용 방법을 개발하고 정책화할 필요가 있다. 세계 물공급량 중 농업으로는 70%, 에너지로는 15%로 소비되고 있다. 또한 유럽과 미국은 발전용 냉각수로 각각 담수총량의 43%, 50%를 사용하고 있는 등, 세계는 물, 식량 그리고 에너지 수급의 불균형이 심화되고 상호 위기가 증폭되고 있다. 향후 인간의 삶에 절대적으로 필요한 세가지 자원이 복합적으로 연계되어 상호 위기가 증폭될 수 있는 실정이나, 우리나라는 개별자원에 대한 관리 및 운영기술은 상당한 수준이지만 아직까지 연계성을 고려하여 자원간의 효율성을 찾는 물-에너지-식량 연계(Water-Energy-Food Nexus, WEF Nexus)에 대한 관리 및 기술은 부족한 실정이다. 국제적으로 세자원의 연계상황이 선진국과 개도국간에 편차가 크고, 사막지대 등 자연조건이 열악한 지역에서 자원들간의 위기 연계성이 높은 상황이므로 우리나라도 물-에너지-식량의 연계위기 상황을 정확히 파악하고 미래 환경변화에 대한 대응방안 수립이 필요하나, 현재 국내 물관리에 있어 저수지나 수리시설 관리가 제대로 실행되지 못하고 있어 이를 방치할 경우 중장기적으로 식량 및 에너지생산에 있어 부족이 우려되고 있다. 또한 부처간의 행정적인 간격으로 물-에너지-식량의 연계성 연구 및 정책수립에 있어서 자료 등이 절대적으로 부족한 실정이기 때문에 체계적으로 빅데이터 기반의 DB구축 및 인벤토리 정의 등도 현재시점에서는 절대적으로 필요하다고 할 수 있다. WEF Nexus를 실현하기 위해서는 각 자원간의 효율성을 극대화하여야 한다. 과거에는 개별적 자원의 확보를 추구했다면 이제부터는 각 자원간의 상생을 통한 연계성을 확보하여 서로간의 자원 확보를 고려하여 개발하여야 한다. 이를 위해 현재의 자원확보에 대한 문제점들을 고려하여, 상호 연계를 통한 효율성을 확보하고 그 효율성이 각 자원에 영향을 주어 시너지효과를 발생시킬 수 있는 방안으로 진행되어야 할 것으로 판단된다.

  • PDF

Study for Flow Phenomenon in the Circulation Water Pump Chamber using the Flow-3D Model (Flow-3D 모형을 이용한 순환수취수펌프장 내 흐름현상 연구)

  • Ha, Sung-Won;Kim, Tae-Won;Choi, Joo-Hwan;Park, Young-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.580-589
    • /
    • 2019
  • Indonesia has a very short supply of electricity. As a solution to this problem, plans for construction of thermal power plants are increasing. Thermal power plant require the cooling water system to cool the overheated engine and equipment that accompany power generation, and the circulation water pump chamber among the cooling water system are generally designed according to the ANSI (1998) standard. In this study, the design criterion $20^{\circ}$ for the spreading angle of the ANSI (1998) of the layout of the circulating water pump chamber can not be satisfied on the K-coal thermal power plant site condition in Indonesia. Therefore, 3-D numerical model experiment was carried out to obtain a hydraulically stable flow and stable structure. The Flow-3D model was used as numerical model. In order to examine the applicability of the Flow-3D model, the flow study results around the rectangular structure of Rodi (1997) and the numerical analysis results were compared around the rectangular structures. The longitudinal velocity distribution derived from numerical analysis show good agreement. In order to satisfy the design velocity in the circulating water pump chamber, a rectangular baffle favoring velocity reduction was applied. When the approach velocity into the circulating water pump chamber was occurred 1.5 m/s ~ 2.5 m/s, the angle of the separation flow on the baffle was occurred about $15^{\circ}{\sim}20^{\circ}$. By placing the baffle below the separation flow angle downstream, the design velocity of less than 0.5 m/s was satisfied at inlet bay.

Thermal Performance of PV Cells Exposed to Irradiation by a Parabolic Trough Concentrator (PTC형 태양열 집열기로 조사되는 PV cell의 열적 성능)

  • Hwang, Seon Yeob;Kang, Tae Gon;Boo, Joon Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.68-68
    • /
    • 2011
  • 본 연구에서는 PV cell이 직달 일사에 노출되는 경우와 집광된 태양광에 조사되는 경우의 성능을 비교하는 한편 집광기의 형태에 따른 열적 성능을 검토하고자 하였다. PV cell은 본질적으로 반도체의 특성을 가지므로 작동온도의 상승에 따라 성능이 저하된다는 사실이 알려져 있으며, 태양조사의 강도 및 밀도 등 특성에 따라서도 성능의 변화를 예상할 수 있다. 그러나 이러한 성능변화에 관련된 인자들과 그 영향의 크기에 대한 정량적인 기술자료가 부족하므로 설치와 이용에 한계가 있는 것이 현실이다. 인공태양 장치(solar simulator)를 이용하여 0.7에서 1.2 sun 범위의 태양 조사 환경에서 결정질 실리콘계 PV cell과 집광형 PV cell의 성능을 검토하였다. 집광에 사용한 PTC는 집광면적의 폭이 500 mm이며, 집광 조사면적이 최소 10 mm인 경우 이론적 최대 집광비가 50이었다. PTC의 축방향으로는 균일한 태양조사가 있게된다는 것을 가정하여 모델의 길이는 간편한 실험을 위해 150에서 500 mm의 범위에서 제작하였다. 수평으로 놓인 PTC의 상부 초점 위치로부터 집광면이 아래 쪽에 위치할수록 집광 조사 면적이 증가하므로 PV cell의 크기에 따라 PTC 초점의 위치로부터 거리를 결정하였다. 한편, PTC 자체의 성능도 촛점거리와 집광면 폭의 비에 따라 달라질 수 있다는 가정 하에, 포물면의 최저 위치로부터 촛점거리는 각각 300, 400 및 500 mm가 되도록 세가지 형태를 제작하여 사용하였다. 동일한 형태의 PTC에서 PV cell의 동일한 설치 위치에서도 최고 $110^{\circ}C$ 범위의 PV cell의 작동 (표면) 온도에 따른 성능의 차이를 관찰하기 위해 셀의 후면을 냉각시키는 경우와 그렇지 않은 경우를 비교하였다. PV cell의 표면 온도 측정을 위해서, 후면의 온도와 같이 광선 차단 효과의 우려가 없는 경우에는 열전대를 설치하였으며, 셀의 전면 온도 측정을 위해서는 비접촉식 적외선 온도계를 사용하였다. 냉각 방법으로는 공기를 이용한 자연대류와 액체를 사용하는 강제대류의 경우를 고려하였으며, 필요에 따라 적절히 설계된 히트싱크를 설치하여 비교 실험을 진행하였다. 강제대류 냉각의 경우는 항온조를 사용하여 순환하는 냉각수의 유량과 공급온도를 변화시킴으로써 PV cell의 작동온도를 조절하고, 이에 따른 발전 성능의 변화를 관찰하였다. 본 연구에서 도출한 실험 및 분석 결과는 PV cell의 설치 환경과 작동온도의 변화에 따라 그 성능 변화를 예측할 수 있는 기술적 자료를 제공함으로써 에너지 이용의 합리화를 도모하는데 기여할 수 있을 것이다.

  • PDF