• Title/Summary/Keyword: 내화 성능

Search Result 584, Processing Time 0.032 seconds

각형 강관기둥부재의 한계온도 평가 연구 (Evaluation of Limiting Temperatures of Rectangular Hollow Sections)

  • 권인규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.331-332
    • /
    • 2012
  • Structural steel has been used as a primary materials to columns and beams since 1960's in Korea with an advantages of excellent of load-bearing capacity and design flexibility, and faster construction. However, if the steel columns made of structural steel exposed to fire the load-bearing capacity is going down steadily and finally reach to collapse. Therefore, building regulation requires fire resistance according to building occupation, scales. The fire resistance can be evaluated two categories. One is prescriptive method that is based on building regulation, specification and so on and the other is performance-based fire engineering method. The latter can be designed based on scientific and engineering consequences. The easiest evaluation way using the fire engineering design is comparing to the limiting temperature and maximum temperature calculated based on heat transfer theory. If the limiting temperature of a column exceeds the maximum temperature of it, the column can carry the load during the fire. Therefore, the database of limiting temperature is very essential for evaluation of column. In this paper, to build the database of column made of rectangular hollow sections 8 fire tests with loading were conducted and the relation between the limiting temperature and the applied loads showed in reverse proportion.

  • PDF

방사선 중합에 의한 폴리프로필렌 정밀여과막의 제조 및 친수화 거동에 관한 연구 (A Study on the Preparation and Hydrophilization of Polypropylene Microfiltration Membrane by Radiation-Induced Graft Polymerization)

  • 황택성;이선아;황의환
    • 폴리머
    • /
    • 제24권5호
    • /
    • pp.621-628
    • /
    • 2000
  • 폴리프로필렌 다공성 분리막은 산, 알칼리에 대한 내화학성이 좋고, 기계적 성질이 우수하며 높은 열적 안정성을 가지고 있으나, 막의 소수성 때문에 일부 영역에만 사용이 제한되고 있다. 따라서 본 연구에서는 소수성 막의 성능을 향상시키기 위해서 방사선 조사에 의한 그라프트 중합법을 사용하여, 친수성 작용기 (-COOH, -OH)를 갖는 acrylic acid (AAc)와 2-hydroxyethyl methacrylate (MEMA)를 도입하였다. 이때 반응시간, 반응온도, 조사량, 간의 첨가 효과, 팽윤현상에 의한 그라프트율의 변화를 조사하였다. 분리막의 기공크기를 분석하는 방법으로 행한 가스투과 실험에서 단량체의 종류와 관계없이 그라프트가 증가함에 따라 가스 투과속도가 감소함을 보였고, 오일 에멀젼 투과실험에서 미개질 폴리프로필렌 막의 오염현상은 크게 발생하였으나, 그라프트 중합 후, 높은 투과속도를 유지하여 막의 친수화 효과가 큰 것으로 나타났다.

  • PDF

도로터널 내 화재에 따른 시간-온도 가열곡선 도출 (Time-Temperature Curve of road tunnel for fire)

  • 최민정;장창일;이상우;김준모;원종필
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.713-716
    • /
    • 2008
  • 본 연구는 도로터널 내 화재시 콘크리트 구조체의 내화성능을 평가하기 위한 기준을 제시하고자 실시하였다. 현재 국내에서는 지형특성 및 환경친화적인 도로건설로 도로 터널의 수가 빠른 속도로 증가하며, 터널연장이 길어짐에 따라 터널 내 화재사고가 갈수록 높아지고 있는 상황이다. 하지만 우리나라에서는 터널 화재에 대한 적합한 시간-온도 곡선을 규정하지 못하고 있는 실정이다. 따라서 본 연구에서는 국내 도로의 통행량, 차량 종류등을 고려한 열방출율을 기초로 외국에서 제시된 시간-온도 곡선을 검토해 보았으며 설계화재 모델을 제시하였다.

  • PDF

프리스트레스트 콘크리트 슬래브의 내화성능 예측에 대한 해석적 연구 (Analytical Study on Fire Resistance Predictions of Prestressed Concrete Slabs)

  • 민정기;박민재;주영규
    • 한국공간구조학회논문집
    • /
    • 제17권1호
    • /
    • pp.69-75
    • /
    • 2017
  • In fire design for floors, the three criteria of stability, integrity and insulation are required for the specified fire resistance duration. Among these, stability is not easy to confirm. For solid prestressed concrete slabs of uniform thickness, Eurocode 2 provides tabulated data and specifies an axis distance to the centroid of strands to achieve particular fire resistance ratings, but it is not clear if this data can be used for a wide range of different prestressed slab profiles. In order to verify the current code-fire ratings for precast prestressed slabs, both simple and advanced calculation methods are investigated. This paper examines the use of calculation methods, accounting for the real behaviour of unprotected simply supported prestressed concrete slabs exposed to the standard ISO 834 fire. The calculated fire resistance of each prestressed concrete slab is compared with tabulated data in Eurocode part 1.2, with detailed discussion.

구조용 압연강(SS 400)의 고온 기계적 특성을 이용한 기둥부재의 내화성능 평가 (Evaluation of Fire Resistance Using Mechanical Properties at High Temperature for Steel Column Made of Rolled Steels (SS 400))

  • 권인규;신순기
    • 대한금속재료학회지
    • /
    • 제49권9호
    • /
    • pp.671-677
    • /
    • 2011
  • Steel columns used in steel buildings are inclined to lose their strength when exposed to severe fire conditions, so fire resistance is required in most countries to protect against loss of life and building collapses. In Korea, the fire resistance of columns can be obtained by the fire test defined in KS F 2257-1, 7. The fire resistance of a steel column should be evaluated in terms of the column's conditions, such as various section types (H-section, hollow-section), the column's length and boundary conditions, and whether it is fixed or hinged. However, fire testing of steel columns is usually conducted on one standard-sized H-section over 3,000 mm, and the result is used as the column's fire resistance. This is not a reasonable way to ensure that a building can withstand fire conditions. In this study, to evaluate the possibility of calculating the fire resistance of steel columns with material properties of high tensile strength of SS 400, both load-bearing fire tests and calculation of steel temperatures were carried out. The results of temperature calculation were very similar to those obtained by fire test.

진공압출성형 고인성 시멘트 패널의 역학 및 내구특성에 관한 실험적 연구 (An Experimental Study on the Mechanical and Durability Properties of Ductile Cement Panel Used Vacuum Extrusion Molding)

  • 노형남;이종석;한병찬;권영진;이상수;송하영
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.473-476
    • /
    • 2008
  • 최근 건설분야에서 고기능화의 추구와 국제적 물가 상승에 기인하여 건설산업에 있어서 공기 단축과 건식공법에 의한 경제적 비용 절감을 추구함과 동시에 시멘트를 사용한 2차 제품의 적용이 점차 증대되고 있으나, 아직까지 건축 내 외장에서의 패널이나 기능적인 보수 보강 측면에서의 용도로만 사용하는데 국한되어 있어, 구조적인 성능이나 내구적인 성능의 개선을 위한 대책이 시급한 실정이다. 이에 따라 본 연구에서는 건설분야에 있어서 구조적 성능과 내구적 성능이 우수한 영구 거푸집의 적용가능성을 검토하고, 제조성능과 품질에 있어서 최적의 배합을 도출하고자 한다. 따라서, 4조건의 배합에 따른 진공압출성형 고인성 시멘트 패널의 역학 및 내구적 특성을 비교 분석한 결과 소량의 충전재와 다량의 고로슬래그 미분말 및 분말내화재료를 사용한 ECC-DP3의 시험체가 우수한 상대경도와 휨응력변형을 나타내었으며, 내구적 성능에서도 공극률 감소 및 수밀성 향상에 의해 우수한 경향을 나타내었다.

  • PDF

띠형 섬유보강재의 장기성능 평가를 위한 실험적 연구 (Experimental Study on Long-Term Performance Evaluation of Geosynthetic Strip Reinforcement)

  • 이광우;김주형;조삼덕;한중근;윤원일;홍기권
    • 한국지반신소재학회논문집
    • /
    • 제9권4호
    • /
    • pp.75-84
    • /
    • 2010
  • 본 연구에서는 띠형 섬유보강재의 인장특성, 크리프 변형, 내시공성 및 내구성을 평가하기 위한 일련의 장기성능 평가시험을 수행하였다. 또한 시험결과를 바탕으로 장기설계인장강도 산정을 위한 강도감소계수를 평가하였다. 먼저, 크리프 변형 특성을 평가하기 위해 단계 등온법과 시간-온도 중첩법을 이용하였으며, 크리프 감소계수는 1.6을 적용하는 것이 바람직한 것으로 평가되었다. 다음으로 입도 조정된 화강풍화토를 성토재로 사용하여 수행한 내시공성 시험 결과, 보강재의 강도특성에 영향을 미치는 원사의 손상이 거의 없는 것으로 확인되어, 장기설계인장강도에 큰 영향을 미치지 않을 것으로 분석되었다. 마지막으로 내구성 평가 결과, 내화학성, 내미생물 및 내후성을 고려한 강도감소계수는 1.1을 적용하는 것이 합리적인 것으로 평가되었다.

  • PDF

경화제의 첨가에 따른 UP와 EPS 혼입 MMA 수지의 경화특성 (Hardening properties in MMA monomer using UP and EPS in addition hardener)

  • 이정희;송훈;추용식;이종규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.445-448
    • /
    • 2008
  • 철근콘크리트 구조물은 내구성 등이 우수한 건설재료로 사용되고 있지만 최근 시간의 경과에 따른 자연 노후화, 환경의 변화에 의한 부재 및 재료 자체의 성능 저하로 구조물의 기능이 저하된다. 따라서 철근콘크리트의 균열 발생은 불가피하며, 균열의 발생은 외부 물질의 침투로 구조물 노후화의 촉진을 발생시킨다. 따라서 콘크리트 구조물에 발생되는 노후화 및 균열의 발생은 구조물의 안정성에 위해를 가져올 수 있다. 이런 구조물의 안정성을 유지하기 위해서는 주기적인 점검 및 구조물의 성능을 원래 및 동등 이상의 상태로 회복시켜야하는 기술이 필요하다. 기존 하수관거 비굴착 전체 보수 공법에서는 라이너 함침 재료로서 경제성 및 내구성, 내화학성이 우수한 불포화폴리에스터수지(UP) 또는 에폭시수지(Epoxy)가 일반적으로 사용된다. 하지만 불포화폴리에스터 또는 에폭시수지를 함침재료로서 현장에 적용하기 위해서는 공장에서 생산된 수지함침 라이너를 냉각차($-5{\sim}5^{\circ}C$)로 현장까지 운반 해야하는 불편함이 있다. 또한 현장시공에 있어 경화시간을 단축하기 위하여 온수 및 고온의 증기로 경화를 촉진시켜야 하며, 이로 인해 별도의 가열장치를 필요로 한다. 그러므로 현장에서의 함침이 가능하며 저온환경에서도 작업성이 우수하며 가사시간 조절이 가능하다면 보다 유리하게 작업을 진행할 수 있다. 따라서 본 연구에서는 저온경화성, 내약폼성, 내마모성 등이 뛰어난 것으로 알려진 MMA 모노머에 EPS를 각각 10, 20, 30%를 혼입하여 제작한 수지의 점도변화 및 가사시간 및 경화시간 등의 변화를 검토하여 하수관거 보수용 수지로서 적합한지를 검토하였다. 연구결과, 개시제 및 촉진제의 첨가량에 따라 가사시간 및 경화시간을 조절할 수 있었으며 하수관거 보수용 수지로서의 이용가능성을 확인할 수 있었다.

  • PDF

폴리머 콘크리트를 적용한 하수암거의 공학적 특성 (Engineering Properties of Sewage Polymer Concrete Culvert)

  • 권성준;민병윤;박상순
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권6호
    • /
    • pp.9-17
    • /
    • 2012
  • 콘크리트 하수 암거는 항상 유해이온에 노출되어 있으므로 사용기간의 증가에 따라 내구적인 문제점을 보이며, 이러한 열화는 구조적인 문제로 진전된다. 콘크리트 하수암거는 일단 매립 후 유지관리가 어려우므로 초기에 높은 내구성 및 안전성을 요구한다. 최근 들어 역학적 특성과 내구적 성능의 개선을 위하여 폴리머 콘크리트가 사용되고 있다. 본 논문에서는 폴리머 콘크리트를 이용한 하수암거에 대한 공학적 성능을 평가하였으며, 축소 모형을 통하여 이음부의 누수와 접착강도를 평가하였다. 제작된 폴리머 하수암거는 100MPa 이상의 높은 압축강도를 확보하였으며, 낮은 투수성 및 염소이온 침투성을 확보하고 있었다. 또한 내화학성 및 생물학적 시험 등에서도 우수한 저항성을 확보하고 있었다. 축소모형실험을 통하여, 이음부 누수가 없고 높은 접착강도를 확보하고 있음을 평가하였으며 연결부의 일체거동을 확인하였다. 본 연구에서 제작된 프리캐스트 폴리머 하수암거는 하수도관과 같이 열악한 환경조건에 적극적으로 사용될 수 있다고 판단된다.

고도정수처리용 콘크리트 금속용사 피막의 내오존성 및 오존처리 후 부착강도 평가에 관한 실험적 연구 (Experimental Study on Evaluation of Bond Strength after Ozone Treatment and Ozone Resistance of Concrete Metal Spray Coating for Advanced Water Treatment)

  • 박진호;장현오;이한승
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권4호
    • /
    • pp.68-75
    • /
    • 2018
  • 기존의 정수처리 방법으로는 제거되지 않는 물질이 발생함에 고도정수 처리 시설의 도입이 증가하고 있다. 그러나 오존을 이용한 고도정수처리 시설의 내부 방수 방식재는 오존의 산화력에 의해 열화되며 콘크리트까지 영향을 미쳐 내구성 저하의 원인이 된다. 본 연구에서는 내오존성 및 내화학성이 뛰어난 금속 패널을 기존의 시공법 보다 손쉬운 방법으로 시공하기 위한 방법으로 금속용사 공법을 이용하여 수처리 시설 콘크리트 구조물의 열화를 원천적으로 방지하기 위한 마감공법 개발 연구의 일원으로 용사금속 종류 및 피막의 표면처리 방법에 따른 내오존성 평가를 실시하였으며, 오존처리 후의 부착강도를 평가하였다. 실험결과 용사금속 Ti이 용사 후에도 내오존성이 뛰어난 것으로 나타났으며 표면처리 방법으로는 테프론계 봉공처리제를 사용하여 마감하는 것이 내오존성 및 부착성능 확보에 가장 적합한 방법이라 판단된다.