• Title/Summary/Keyword: 내화성

Search Result 515, Processing Time 0.025 seconds

A Preliminary Study on the Fire Safety Testing Method for Fire-resistance Paints Using an X-ray Analysis Method (X-선 분석법을 이용한 내화도료의 화재안전성 평가 방법에 관한 기초연구)

  • Shim, Ji-Hun;Cho, Nam-Wook;Kim, Kang-Woo
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.58-63
    • /
    • 2014
  • Fire-resistance paints are supposed to become intumescent and diminish heat transfer along the steel frames in case of a fire. If unsatisfactory fire-resistance paints which do not satisfy their standard specification are used, it may result in a severe disaster. Because satisfactory fire-resistance paints are hardly discriminated from the unsatisfactory ones by a simple visual inspection, more reliable and convenient onsite evaluation methods are necessary. Here we report the preliminary study result on the fire safety testing method for fire-resistance paints using an X-ray analysis method. It was found that the existence and quantity of effective constituents in fire-resistance paints can be detected by the X-ray analysis method. X-ray fluorescence (XRF) analyses showed that P and Cl elements are much more enriched in fire-resistance paints, compared to normal paints. X-ray diffraction (XRD) analyses showed that ammonium polyphosphate is present as the main crystalline material in fire-resistance paints, but absent in normal paints. The X-ray analysis method is expected to be used for the onsite inspection of fire-resistance paints with the upcoming availability of portable XRF and XRD instruments.

An Experimental Study on the Chemical Resistance of Concrete(II) -The case of mortar with silica sand particle- (콘크리트의 내화학성에 관한 실험적 연구(II)-규사 분말을 치환한 모르터의 경우-)

  • 윤보현;김제원;설광욱;김명재;부척량
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.1
    • /
    • pp.153-163
    • /
    • 1997
  • This paper is an experimental study of the chemical resistance of mortar which contains silica sand particles. The possible use of silica sand particles in the future as an admixture for improving chemical resistance of mortar is examined in mortar model experiments. The possibility of using mortar model its prediction models for the chemical resistance of concrete is examined. The results obtained are as follows. Since the experimental results from the chemical resistance tests based on the kinds and the amount of replaced admixture are similar to those from the concrete. mortar model could be used as a prediction model of chemical resistance of concrete.

A Study of Fire-resistance Light-weight Inorganic Foam Material Using Cullet and Fly-ash (유리분말과 플라이애시를 사용한 내화성 경량 무기발포 소재 연구)

  • Shin, Hyeon-Uk;Song, Hun;Chu, Yong-Sik;Lee, Jong-Kyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.79-81
    • /
    • 2011
  • To prevent energy waste in buildings used heat insulator. Heat insulator materials can be classified inorganic and organic. The organic material is due to toxic gas emission, when a fire occurs. And it has lower water resistance. The inorganic material is heavy and worse thermal performance than organic materials. This study focused on evaluation of the physical properties and fire-resistance of inorganic foam material for using industrial by-products materials for the applicability of Fire-resistance Light-weight material.

  • PDF

The Examination Fire Resistance of Mortar According to Particle Size Distrivution as Oyster Shell Fine Aggregate (굴 패각의 잔골재 입도분포 변화에 따른 모르타르의 내화성 검토)

  • Choi, In-Kwon;Jung, Ui-In;Kim, Bong-Joo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.71-72
    • /
    • 2017
  • The oyster shell is lightweight and exhibits strength characteristics similar to sand. In this study, mortar specimens were fabricated by crushing them and processed to 5mm or less of the fine aggregate standard, and examined the fire resistance of the mortar according to changes in particle size distribution. In this experiment, seven particle size distribution conditions were tested. In addition, the mixing ratio was fixed at 1: 3, and the experiment was conducted in terms of the volume ratio because the densities of sand and oyster shells were different.

  • PDF

Behavior of Fire Resistance Engineered Cementitious Composites(FR-ECC) under Fire Temperature (화재 온도를 받는 고인성.고내화성 시멘트 복합체의 거동)

  • Han, Byung-Chan;Kwon, Young-Jin;Kim, Jae-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.2
    • /
    • pp.189-197
    • /
    • 2007
  • Concrete tunnel lining must be designed to having the fireproof performance because the lining are sometimes exposed to very high temperature due to traffic accident. Such fire temperature may cause explosion of concrete, or collapse of tunnel structure. The purpose of this study is to obtain the fundamental fireproof behavior of fire resistance-engineered cementitious composites(FR-ECC) under fire temperature in order to use the fire protection material in tunnel lining system. The present study conducted the experiment to simulate fire temperature by employing 2 types of FR-ECC and investigated experimentally the explosion and cracks in heated surface of these FR-ECC. Employed temperature curve were hydro carbon(HC, ECl) criterion, which are severe in various criterion of fire temperature. The numerical analysis is carried out the nonlinear transient heat flow analysis and verified against the experimental data. The complex features of behavior in fire conditions, such as thermal expansion, plasticity, cracking or crushing, and material properties changing with temperature are considered. By the use of analytical model, the concrete tunnel subjected to fire loads were analyzed and discussed. With comparison of current concrete materials and FR-ECC, the experimental and analytical results of FR-ECC shows the better fire resistance performance than the other.

A Evaluation of Fire Behavior According to Member Thickness of Precast Prestressed Hollow Core Slab of Fire Resistance Section (프리캐스트 프리스트레스트 내화단면 중공슬래브의 부재두께에 따른 화재거동평가 )

  • Yoon-Seob Boo;Kyu-Woong Bae;Sang-Min Shin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.1
    • /
    • pp.1-8
    • /
    • 2023
  • At construction sites, interest in the production of precast materials is increasing due to off-site conditions due to changes in construction site conditions due to increased labor costs and the Act on the Punishment of Serious Accidents. In particular, the precast prestressed hollow slab has a hollow shape in the cross section, so structural performance is secured by reducing weight and controlling deflection through stranded wires. With the application of structural standards, the urgency of securing fire resistance performance is emerging. In this study, a fire-resistance cross section was developed by reducing the concrete filling rate in the cross section and improving the upper and lower flange shapes by optimizing the hollow shape in the cross section of the slab to have the same or better structural performance and economic efficiency compared to the existing hollow slab. The PC hollow slab to which this was applied was subjected to a two-hour fire resistance test using the cross-sectional thickness as a variable, and as a result of the test, fire resistance performance (load bearing capacity, heat shielding property, flame retardance property) was secured. Based on the experimental results, it is determined that fire resistance modeling can be established through numerical analysis simulation, and prediction of fire resistance analysis is possible according to the change of the cross-sectional shape in the future.

Thermal Stress Analysis of Refractory of VOD Ladle Using Finite Element Method (유한요소법을 이용한 VOD Ladle 내화물의 열응력 해석)

  • 이순욱;조문규;임종인;함경춘;배성인;송정일
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.2
    • /
    • pp.193-198
    • /
    • 2001
  • 유한요소법을 이용하여 STS VOD 래들에서 내장 내화물의 재질 및 back filler의 시공 위치에 따른 열응력을 수행하였다. 불소성 내화물의 경우 높은 열전도율에 의해 가동면과 배면(back face)간의 온도구배가 소성품에 비해 감소하였으며 탄성계수도 낮아 발생되는 열응력이 2~4배 낮았다. Back filler는 dolomite 내화물의 열간 팽창을 흡수하기 위해 시공하는 것으로, 상대적으로 낮은 열전도율을 가지고 있기 때문에 back filler의 내부와 외부에 급격한 온도구배가 발생된다. 결과적으로 래들의 내부는 고온을 유지하여 내화물이 팽창이 되고, 외부는 온도가 낮아지므로 수축되어 열응력이 증가하였다.

  • PDF

A Study on the Fire Resistance Performance of Mortars Using Mesoporous Silica Nanoparticles(MSNs) and PVA Fibers (다공성 나노실리카 입자(MSNs)와 PVA섬유를 혼입한 모르타르의 내화성능에 관한 연구)

  • Cheonpyo Park;Jakyung Lee;Taehyung Kim
    • Journal of the Korean Geosynthetics Society
    • /
    • v.22 no.4
    • /
    • pp.51-61
    • /
    • 2023
  • In this study, in order to improve the fire resistance performance of structures in case of fire in buildings and structures, PVA fibers and the ZnO particles combined with mesoporous nano silica (MSNs) were mixed with cement mortar, and the specimen was exposed to a temperature range of 20~1100℃. Then the residual compressive strength and weight change rate were measured to determine whether the fire resistance performance changed. As a result of the study, it was found that mixing mesoporous nano silica and PVA fiber together did not contribute to improving the fire resistance performance of cement mortar. On the other hand, mixing 0.5% of mesoporous nano silica and 0.1 vol% of PVA fiber showed the best improvement test results, showing that it was advantageous for fire resistance performance.

Comparative Analysis of Fire Resistance in Glued Laminated Timber: The Impact of Adhesives and Surface Direction (구조용 집성재의 접착제 종류 및 접착면 방향성에 따른 내화성능 비교 분석)

  • Choi, Yun-Jeong;An, Jae-Hong;Baik, Kwon-hyuk
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.6
    • /
    • pp.761-772
    • /
    • 2023
  • The fire resistance design of timber structures involves calculating the residual section based on charring depth, which is then utilized in structural design. Charring depth is determined from fire-resistance test results in Korea, which currently do not account for the charring properties of the adhesive used in Glued Laminated Timber(GLT) production. This study fabricated GLT using various adhesives employed in domestic GLT production, comparing the charring properties by adhesive type and the fire resistance performance relative to the directionality of the laminated surface. Melamine demonstrated the most advantageous fire resistance performance, followed by resorcinol and polyurethane. Furthermore, it was established that the laminated section exhibited a higher charring rate, influenced by the adhesive, compared to the laminated surface, which significantly impacts the fire resistance performance.

An Experimental Study on the Fire Behavior of Two-way Void Slab under Standard Fire with Loading condition (표준화재 재하조건 이방향 중공슬래브의 화재거동에 관한 실험적 연구)

  • Kim, Hyung-Jun;Yeo, In-Hwan;Kim, Heung-Youl;Cho, Kyung-Suk;Kim, Jeong-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.17-20
    • /
    • 2010
  • 기존의 무량판 구조와 동일한 이방향 슬래브구조인 TVS(two-way void slab)공법은 구조적 하중지지 성능이 불필요한 슬래브 단면상의 중앙부 콘크리트를 제거하여 슬래브의 자중을 줄이고 무량판 구조의 단점을 보완하여 장점을 극대화시킨 구조형식이다. 그러나 이러한 장점을 보유한 공법을 현장적용하기 위해서는 내화성능평가를 통해 화재안전성을 확보하여야 하므로, 이에 대한 화재 실증실험을 수행하여 현장적용을 위한 최소 요구내화 시간에 따른 내화성능 확보방안의 도출이 제시되어야 한다. 이에 본 연구에서는 TVS공법의 실제 스팬길이로 슬래브 피복두께에 따른 화재거동 영향성 분석을 위하여 화재실험을 수행하였다. 하중조건은 고정하중과 적재하중을 고려하여 실험체에 등분포 조건으로 사전재하하였으며, 표준화재조건으로 재하가열 실험을 수행하였다. 슬래브의 화재가열 노출면으로부터의 깊이별 온도변화와 처짐변형 특성을 측정하였으며, KS F 2257-1 평가기준에 의거하여 슬래브의 내화성능을 평가하였다. 실험결과 피복두께 50 mm를 확보할 경우, EPS중공체로 제작한 실험체의 경우 약 2시간정도의 내화성능을 확보할 수 있는 것으로 나타났다.

  • PDF