• Title/Summary/Keyword: 내부 응력

Search Result 965, Processing Time 0.027 seconds

Engineering Characteristics of Diatom Modified Soil Mixture (Diatom 혼합토의 공학적 특성)

  • Kim, Kyu-Sun
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.5
    • /
    • pp.77-84
    • /
    • 2012
  • The engineering characteristics of natural sediments containing diatom microfossils have been investigated for their abnormal deformation and strength behavior for a few decades. The presence of disk or hollow shape diatoms causes low compressibility, high hydraulic conductivity, and high shear strength of sediments. Some of these unusual differences show the characteristic of diatom owing to the interlocking of large interparticle porosity and angular particles. This phenomenon implies the possible use of diatom as modification materials to change the engineering performance of soil mixtures. This paper describes the engineering characteristics of diatom-kaolin mixture to investigate the engineering properties of diatom modified soils using conventional geotechnical tests and elastic and electromagnetic wave propagation tests. Experimental test results show the performance improvement by increasing diatom contents and the performance degradation by the breakage of interlocking between diatom particles under high effective stress.

Assessment of Shear Band Characteristics in Granular Soils Using Digital Image Analysis Technique for Plane Strain Tests (평면변형률 시험에서 이미지 해석을 통한 사질토의 전단면 특성 평가)

  • Jang, Eui-Ryong;Jung, Young-Hoon;Kim, Jun-Young;Chung, Choong-Ki
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.4
    • /
    • pp.51-65
    • /
    • 2011
  • Shear banding, the localization of deformation into thin zones, has a quite practical relevance, as stability and deformation characteristics of earth structures are controlled by the soil behavior within the shear band. In this study, for understanding occurrence and developed pattern of shear band, plane strain compression tests were performed on three soils with different particle-size distribution under various conditions. Digital images were captured during the experiments; then, deformation of a specimen was evaluated by digital image analysis technique. The characteristics of a shear band were evaluated from the state shortly after post-peak occurrence to critical state. Additionally, the statistical procedure was developed to determine the reasonable thickness of a shear band.

Strength of Interior Plat Plate-Column Connections Subjected to Unbalanced Moment (불균등 휨모멘트를 받는 플랫 플레이트-기둥 접합부의 강도산정모델)

  • 최경규;박홍근
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.961-972
    • /
    • 2002
  • Flat plate structures under lateral load are susceptible to the brittle shear failure of plate-column connection. To prevent such brittle failure, strength and ductility of the connection should be ensured. However, according to previous studies, current design methods do not accurately estimate the strength of plate-column connection. In the present study, parametric study using nonlinear finite element analysis was performed for interior connections. Based on the numerical results, a design method for the connection was developed. At the critical sections around the connection coexist flexural moment and shear developed by lateral and gravity loads, and maximum allowable eccentric shear stresses were proposed based on the interactions between the flexural moment and shear, The proposed method can precisely predict the strength of the connection, compared with the current design provisions. The predictability of the proposed method was verified by the comparisons with existing experiments and nonlinear numerical analyses.

A Study on Crack Control of Tunnel Lining Concrete with Large Section (대단면 터널 라이닝 콘크리트의 균열저감 연구)

  • Kim, Wan-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.509-512
    • /
    • 2008
  • The lining concrete of water tunnel is a much capability to occur crack due to drying shrinkage and vibrator compaction etc. Because of crack of concrete induce structural problem and decrease durability of concrete, it is need to reduce crack of concrete. In this an Analytical study to analyze the effect of curing of concrete and compaction on the lining concrete. As the results, it was found that control of construction condition into curing of concrete and compaction improve on construction efficiency of the lining concrete.

  • PDF

Hydration Heat Analysis of Mass Concrete considering Heat Transfer Coefficient and Hydration Heat Difference (수화발열량차 및 열전달계수 변화를 고려한 매스콘크리트의 수화열 해석)

  • Han, Seung-Baek;Lee, Seong-Su;Shin, Hyo-Bum;Kim, Ho-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.249-252
    • /
    • 2008
  • In recent large-scale structures, as mass concrete type structure is frequently applied to the building, temperature crack due to hydration heat needs to be considered. Since a volume change is internally or externally restricted in a mold after placing concrete, temperature crack of mass concrete takes place. By this reason, the reduction method to control this crack is required. In this study, low heat mixture and hydration heat difference is used to execute the analysis of hydration heat, considering the changes of heat transfer coefficient according to curing conditions and block placement of mass concrete. For the analytical modelling, original portland cement and concrete of low heat mixture are placed in the upper and lower payer, respectively. A convection boundary condition is fixed because mass concrete of block placement is characterized by the difference of mold form and curing condition. Through the analysis results considering the changes of low heat mixture, block placement, and heat transfer coefficient, we check out the temperature and stress distribution and analyze the temperature crack reduction effect.

  • PDF

Trends of Research and Practical Use on Explosive Spalling Properties and Performance Based of Structural Design of the High-Strength Concrete (고강도콘크리트의 폭렬대책공법에 대한 국내외 현황과 성능적 구조내화설계를 위한 과제)

  • Kwon, Young-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.935-940
    • /
    • 2008
  • When reinforced concrete is subjected to high temperature as in fire, there is deterioration in its properties of particular importance are loss in compressive strength, cracking and spalling of concrete, destruction of the bond between the cement paste and the aggregates and the gradual deterioration of the hardend cement paste. Assessment of fire-damaged concrete usually starts with visual observation of color change, cracking and spalling of the surface. In this paper, it was reported the trends of research and practical use on the Explosive Spalling Properties and Performance Based of Structural Design of the High-Strength Concrete.

  • PDF

Cracks in Tape Cast Oxide Laminar Composites (테이프 캐스팅 산화물 층상 복합체에서의 균열)

  • Kim, Ji-Hyun;Yang, Tae-Young;Lee, Yoon-Bok;Yoon, Seog-Young;Park, Hong-Chae
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.5
    • /
    • pp.484-489
    • /
    • 2002
  • Hot-pressure sintered laminar composites with alumina/zirconia or mullite/zirconia as an outer layer and alumina/zircon (resulting in reaction-bonded mullite/zirconia during sintering) as an inner layer were fabricated by tape casting and lamination. Various forms of crack were observed in sintered laminar composites, these cracks included channel cracks in the outer layer, transverse cracks in the inner layer and interface cracks debonding interlayer. Based on detailed microscopic observations, the cracks were attributed to thermal expansion mismatch between the oxides consisting of the each layer. In particular, the interlayer and transverse cracks were confirmed in the laminates consisted of the mullite/zirconia system as the outer layers, however, those cracks were not observed in the alumina/zirconia system used. In addition, the crack propagation did not exhibit same behavior in the two kinds of outer layer when the indentation load was applied.

Evaluation of Undrained Shear Strength for Clayey Silt with Low Plasticity from the West Coast (서해안 저소성 점토질 실트 지반의 비배수 전단강도 평가)

  • Kim, Seok-Jo;Lee, Sang-Duk;Kim, Ju-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.8
    • /
    • pp.15-25
    • /
    • 2016
  • In order to analyze undrained shear strength for clayey silt with low plasticity from Hwaseong site, a series of laboratory and in-situ tests were performed. The Unconfined Compressive (UC) test and Simple Consolidated-Undrained Triaxial (SCU) test were examined in order to assess their applicability to the measurement of the undrained strength of this soil. In the case of clayey silt with low plasticity, although the samples were properly taken by undisturbed sampling method, the residual effective stress and the unconfined compressive strength were reduced considerably. Therefore, an effective confining pressure that corresponds to the typical marine clay should be applied to the soil specimen before shearing in order to compensate for the loss of residual effective stress. By evaluating the shear strengths of clayey silt with low plasticity as 75% of $s_{u(scu)}$, the in-situ shear strength of this kind of soil can be duplicated.

Study of Ultrasonic Nonlinearity in Heat-Treated Material (열처리된 재료의 초음파 비선형성에 관한 연구)

  • Li, Weibin;Lee, Jae-Sun;Cho, Youn-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.6
    • /
    • pp.751-756
    • /
    • 2010
  • Ultrasonic nonlinearity is very sensitive to changes in material properties. This paper describes the study of the correlation between heat treatment and ultrasonic nonlinearity by taking nonlinear factors into consideration. A modified formula was proposed for ultrasonic velocity. This formula indicated that the changes occurring in nonlinearity during heat treatments cause changes in the ultrasonic velocity. The experimental results show that the relative nonlinearity parameters calculated from the modified ultrasonic velocities and the ratio of amplitudes of the second harmonic and fundamental wave are in good agreement. The experimental results prove that heat treatment can result in changes in material nonlinearity. Moreover, the relative nonlinearity parameter calculated from the modified velocity formula is has a large value. Since this parameter has high sensitivity to changes in nonlinearity, it can be used to represent the relative nonlinearity change calculated in this study by using the modified formula for ultrasonic velocity.

Design of a Piezocomposite Generating Element and Its Characteristics (압전-복합재료 발전 소자의 설계 및 특성)

  • Tien, Minh Tri;Kim, Jong-Hwa;Goo, Nam-Seo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.7
    • /
    • pp.867-872
    • /
    • 2010
  • Unused energy derived from sources in nature can be captured and stored for future use, for example, to recharge a battery or power a device; this process of capturing and storing energy is called energy harvesting. Extensive investigations are being carried out in order to use piezoelectricity to harvest the energy generated by body movements or machine vibrations. This paper presents a simple analytical model that describes the output voltage effectiveness of a Piezocomposite Generating Element (PCGE) from vibration and its experimental verification. PCGE is composed of carbon/epoxy, PZT, and glass/epoxy layers. During the manufacturing process, the stacked layers were cured at $177^{\circ}C$ in an autoclave, which created residual stresses in PCGE and altered the piezoelectric properties of the PZT layer. In the experiments, three kinds of lay-up configurations of PCGE were considered to verify the proposed prediction model and to investigate its capability to convert oscillatory mechanical energy into electrical energy. The predicted performance results are in good agreement with observed experimental ones.