• Title/Summary/Keyword: 내부표준법

Search Result 135, Processing Time 0.037 seconds

Development of a rapid HPLC method for the determination of penciclovir in human plasma using a monolithic column and its application to a bioequivalence study (모노리틱 칼럼을 이용한 혈장 중 펜시를로버의 HPLC 신속분석법 개발 및 이를 이용한 생물학적동등성시험)

  • Kim, Jin Hee;Park, Ah Yeon;Jung, Eun Ha;Lee, Cheol Woo;Lee, Tae Ho;Youm, Jeong-Rok
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.323-330
    • /
    • 2007
  • A simple and rapid HPLC method with fluorescence detection(FLD) for quantitation of penciclovir in human plasma using a monolithic column was developed and validated. Penciclovir and ganciclovir(internal standard, I.S.) were separated on a Chromolith column RP-18e ($4.6{\times}100mm$) with a mobile phase consisting of a mixture of (A) methanol/50 mM sodium phosphate buffer containing 200 mg/L sodium dodecyl sulfate (3/97, pH 2.5) and (B) methanol/50 mM sodium phosphate buffer containing 200 mg/L sodium dodecyl sulfate (50/50, pH 2.5) at a flow gradient of $1.6{\sim}4.0mL/min$. The retention times of penciclovir and internal standard were less than 4.0 min. Calibration curve was linear ($R^2=0.9994$) over a concentration range of $0.1{\sim}5{\mu}g/mL$. Intra-day precision, accuracy and inter-day precision were 1.36~8.55 %, 92.8~100.0 % and 0.93~5.62 %, respectively with a limit of quantitation at $0.1{\mu}g/mL$. The present HPLC-FLD method is sensitive, precise and accurate. The method described herein has been successfully used for the bioequivalence study of a famciclovir formulation product after oral administration to healthy Korean volunteers.

Study on Optimum Design for Embankment Construction on Soft Ground Treated by SCP (SCP개량지반상에 성토시공 시 최적설계에 관한 연구)

  • Chae, Jong-gil;Park, Yeong-Mog;Jung, MinSu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.6C
    • /
    • pp.251-258
    • /
    • 2009
  • In this study, the optimum design conditions for embankment construction on soft clay layer improved by soil compaction pile (SCP) are discussed by comparing the practical design method to the reliability design which is based on the loss function and advanced first order second moment (AFOSM) method. The results are summarized as follows; 1) the relationship between safety factor and failure probability becomes heavy exponentially, failure probability decreases rapidly till 1% approximately until safety factor is smaller than 1.2 and after then, failure probability decrease gradually along the increase of the safety factor. The design safety factor of 1.2 may be the critical value that has been established on considering both relationships appropriately, 2) the safety factor of 1.15 at the minimum expected total cost is a little smaller than the design safety factor of 1.2 and the failure probability is about 1%, 3) the sensitivities of the ratio of stress share and the internal friction angle of sand is larger than the variables related the undrained shear strength of soft layer. This result means that the distribution characteristic of n and ${\phi}$ influences on the stability analysis considerably and they should be considered necessarily on stability analysis of embankment on soft layer improved by SCP, 4) new failure points of the input variables at the design safety factor of 1.2(below failure probability of 0.1~0.3%) is far 1~2 times of standard deviation from the initial design values of themselves.

Use of Real-Time PCR and Internal Standard Addition Method for Identifying Mixed Ratio of Chicken Meat in Sausages (Real-Time PCR과 Internal Standard Addition법을 이용한 돼지고기 소시지에 혼합된 닭고기의 정량)

  • Lee, Namrye;Joo, Jae-Young;Yeo, Yong-Heon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.9
    • /
    • pp.1097-1105
    • /
    • 2017
  • This study examined how much chicken meat was in sausage made with pork. Both real-time polymerase chain reaction (PCR) and internal standard addition were used. Fifty ng of chicken DNA was added to the sausages as an internal standard. The addition of standard DNA increased the amplification efficiency of PCR and confirmed the possibility of quantitative analysis. A QIAamp DNA Micro Kit was used to improve the DNA recovery and amplification efficiency. The density of template DNA and primer were suitable for $3.0{\sim}5.0{\mu}L$ and $0.5{\mu}L$, respectively. Each DNA of pig and chicken was diluted in 10-fold from steps 50 ng to 0.05 ng. The detection limit of both pig and chicken meat was more than 0.05 ng and the correlation coefficient of the standard curve was at least 0.98. The result of the quantitative analysis after heat treatment of 3 samples of pigs and chickens mixed at 70:30 showed a 5.7% difference (64.3:35.7) between the expected value and measured value. The quantitative value was changed by affecting the DNA according to the heat treatment ($70^{\circ}C$, 10 min). An analysis of the pork and chicken content in sausages showed that it was difficult to detect chicken meat and the quantitative value of DNA according to the Ct value was very low. On the other hand, when adding standard material (50 ng of chicken DNA) to the sausages, the Ct value decreased gradually with increasing chicken mixing ratio. Thus, the mixing ratio of chicken in sausages could be estimated.

Quantitative analysis of cholesterol in infant formula by isotope dilution liquid chromatography-tandem mass spectrometry (동위원소희석 액체크로마토그래피 질량분석법에 의한 분유 내 콜레스테롤의 정량)

  • Ahn, Eun Jeong;Lee, Hwa Shim;Kim, Byung Joo;Lee, Gae Ho
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.460-466
    • /
    • 2015
  • An isotope dilution liquid chromatography tandem mass spectrometry was developed as a primary method for the quantitative analysis of cholesterol in infant formula. Cholesterol-d4 was used as an internal standard and spiked into the infant formula sample. In order to release cholesterol out of cholesteryl ester, which is cholesterol bound to fatty acids in infant formula, saponification was carried out. Saponification conditions were optimized with heating temperature, reaction time and the concentration of KOH. The optimum conditions were as follows; heating temperature was 70 ℃, reaction time was 180 min and the concentration of KOH was 0.8 mL of 8 M KOH for about 0.1 g infant formula sample. Extraction of cholesterol out of sample solution was carried out with hexane uisng liquid-liquid extraction. Chromatographic analysis was carried out using Phenomenex Kinetex C18 column. Mobile phase was 0.1% acetic acid in methanol/water (v/v, 99/1) and flow rate was 0.3 mL/min. Cholesterol and cholesterol-d4 were monitored at mass transfer m/z 369/259 and 373/263 respectively. Reproducibility of the method was evaluated to be 0.23% of the measurement result. The expanded uncertainty of the measurement result of cholesterol in infant formula was approximately 1.9% at a 95% confidence level. NIST standard reference material having certified values of cholesterol in infant formula, was analyzed in order to verify this method. The ID-LC/MS/MS results were well agreed with the certified values of NIST SRM within the uncertainty.

Profitability Analysis for Ligularia fischeri Forest Farming (곰취 임간재배 수익성 분석)

  • Park, Sang-Byeong;Kim, Mahn-Jo;Park, Yunmi;Hwang, Suk-In;Kim, Eui-Gyeong
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.3
    • /
    • pp.426-433
    • /
    • 2012
  • This study was carried out for preliminary feasibility review to consult forest farmer, to make policy and to search improvement for Ligularia fischeri forest farm. The survey for eight Ligularia fischeri forest farmer in Inje-gun was conducted. And the case study was conducted with computing labor input, gross margin, net margin in each planting stages, which is contented each cultivating stage from creating to harvesting. B/C ratio, Net Present Value and Internal Rate of Return were used for profitability analysis. The results applied 3% of discount rate showed IRR 48.6%, B/C ratio 1.5 and NPV 41 million KRW, which means high profitability. Forest farming is early step in Korean forestry so that standard methods of cultivation for that haven't established yet, and differences among farmers in productivity are being. Establishing organized methods of cultivation in each stages and being political supports are essential for income generation to forest households, supply of safe food and rest place for urbanity.

Rapid Analytical Method of Volatile- and Semivolatile Organic Compounds in Water and their Monitoring in Water Treatment Plants (물 시료 중 휘발성 및 반휘발성 유기물질들의 빠른 분석법 및 정수처리 단계별 모니터링)

  • Shin, Ho-Sang;Ahn, Hye-Sil
    • Analytical Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.240-250
    • /
    • 2004
  • A gas chromatography-mass spectrometric (GC-MS) assay method was developed for the rapid and sensitive determination of volatile- and semivolatile organic compounds in water. Two hundreds mL of water sample was extracted in a 250 mL separatory funnel with 1 ml of pentane at pH 6.5. Fluorobenzene and 1,2-dichlorobenzene-d4 as internal standards were added to water sample and the solution was mechanically shaken for 5 min and analyzed by GC-MS (selected ion monitoring) without more any concentration or purification steps. The peaks had good chromatographic properties and the extraction of these compounds from water also gave relatively high recoveries with small variations. The range of detection limits of the assay was 0.5-10 ng/L. Turnaround time for up to about 40 samples was one day. This method is simple, convenient, and can be learned easily by relatively inexperienced personnel. This method was used to analyze 15 volatile- and semivolatile organic compounds in water of a Lake, and raw and treated water from three Water Treatment Plants in Korea. As the analytical results, benzene, toluene, xylene, isopropylbenzene, 1,3,5-trimethylbenzene, 1,2,4-trimethylbenzene, naphthalene and 2,4,6-trichlorophenol were detected at concentrations of up to 0.4, 1.9, 1.3, 0.2, 1.8, 13.0, 1.7 and $1.1{\mu}g/L$, respectively. But chlorobenzene, trichloroethylene, tetrachloroethylene, ethylbenzene, n-butylbenzene and dibromochloropropane levels during that period were not significant. The removal effect of the compounds in three Water Treatment Plants was calculated. The compounds studied were generally removed during conventional water treatment, especially during the active carbon filtration.

Path-Loss Modeling for Human Channel of WBAN System (WBAN 시스템용 인체 채널에 대한 경로 손실 모델링)

  • Mun, Ji-Yeon;Kim, Tae-Hong;Seo, Min-Gyeong;Pack, Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.12
    • /
    • pp.1116-1123
    • /
    • 2011
  • In this paper, we studied the propagation of the radio wave in the human body for WBAN system and proposed the path-loss models applicable in the MICS and ISM frequency band. Human Tissues are composed of complicate organ. So it is difficult to measure to insert the probe in human body. Accordingly, the equations were modelled by electromagnetic analysis using the numerical phantom based on the real human. The numerical analysis used XFDTD 6.5 of Remcom co. in commercial software based on the Finite-Difference Time-Domain method. Human body model used a standard adult Korean model developed by ETRI. The proposed channel models will be very helpful to design the WBAN system.

Determination of Copper Ion with 2-Mercaptobenzimidazol Immobilized on Surfactant-Coated Alumina (계면활성제를 코팅한 알루미나에 부동화한 2-Mercaptobenzimidazol을 이용한 구리이온의 정량)

  • Absalan, G.;Goudi, A.Aghaei
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.2
    • /
    • pp.141-146
    • /
    • 2007
  • The present paper describes a procedure for separation, preconcentration and determination of trace amount of copper in natural water samples by using 2-mercaptobenzimidazol as the complexing agent. The proposed method is based on the surfactant aggregation formed on γ-alumina by mixing sodium dodecyl sulfate and γ-alumina in water; 2-mercaptobenzimidazol was incorporated into inner hydrophobic part of produced ad-micelles in acidic media to produce an assemble suitable for preconcentration and determination of copper ion. Optimum experimental conditions for adsorption of μg/ml levels of copper ions from aqueous solution by the adsorbent have been reported. The copper ions were quantitively adsorbed by the sorbent over the pH range of 7.1-8.0 and were quantitatively desorbed afterward by using sulfosalycilic acid as the eluent. The determination of copper was not interfered in the presence of common metal ions. The procedure was applied for analysis of river water sample. Relative standard deviation was found to be 4.91%.

Low-level Determinations of Uranium and Thorium in Geologic Samples by X-ray Fluorescence (x-선 형광분석기톨 이용한 지질시료 중 우라늄과 토륨의 미량분석)

  • Park, Yong Joon;Kim, Jung Suk;Choi, Kwang Soon;Suh, Moo Yul
    • Analytical Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.20-25
    • /
    • 1996
  • Trace levels of uranium and thorium in geologic samples are determined rapidly by a direct wavelength-dispersive X-ray fluorescence method. Relative intensity of scattered tube radiation was used as an internal standard to compensate for variations in instrumental operating characteristics. U and Th can be determined within a precision of ${\pm}10%$ and accuracy of ${\pm}15%$ or less with measuring times of 50 seconds for Th and 400 seconds for U, respectively. The results of XRF analysis were in good agreement with those of other methods such as nutron activation analysis and inductively coupled plasma atomic emission spectrometry.

  • PDF

The Defect Inspection on the Irradiated Fuel Rod by Eddy Current Test (와전류시험에 의한 조사핵연료봉의 결함 검사)

  • Koo, D.S.;Park, Y.K.;Kim, E.K.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.1
    • /
    • pp.29-33
    • /
    • 1996
  • The eddy current test(ECT) probe of differential encircling coil type was designed and fabricated, and the optimum condition of ECT was derived for the examination of the irradiated fuel rod. The correlation between ECT test frequency and phase & amplitude was derived by performing the test of the standard rig that includes inner notches, outer notches and through-holes. The defect of through-hole was predicted by ECT at the G33-N2 fuel rod irradiated in the Kori-1 nuclear power reactor. The metallographic examination on the G33-N2 fuel rod was Performed at the defect location predicted by ECT. The result of metallographic examination for the G33-N2 fuel rod was in good agreement with that of ECT. This proves that the evaluation for integrity of irradiated fuel rod by ECT is reliable.

  • PDF