• Title/Summary/Keyword: 내부온도변화

Search Result 1,150, Processing Time 0.026 seconds

Fluid Flow and Temperature Distribution in the Simplified Chamber (단순화한 챔버에서 유체의 흐름과 온도분포)

  • Han Hyun-Kak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.4
    • /
    • pp.302-308
    • /
    • 2005
  • The temperature distribution and fluid flow in the chamber was investigated using FLUENT code. It provides comprehensive modeling capabilities for a wide range of incompressible or compressible and laminar or turbulent fluid flow problems. And a broad range of mathematical models for transport phenomena is combined with the ability to model for complex geometries. The geometry of the chamber was very complex, and a simplified model of the chamber was used in the simulation experiment. It was important that the temperature deviation of test site. This datum were provided in the improving the control algorithm. Using this algorithm, the results were with in $0.1^{\circ}C.$

  • PDF

Heat Transfer Analysis of the Opaque Solid Heated by Pulsed Laser (Pulsed Laser에 의하여 가열되는 불투명 고체의 열전달 해석)

  • 전민호;이은호;유재석
    • Journal of Energy Engineering
    • /
    • v.8 no.1
    • /
    • pp.181-188
    • /
    • 1999
  • 재료의 표면을 pulsed laser로 가열할 때, 유한한 두께를 가지는 반무한 평판의 온도분포를 해석하여 열확산계수, 재료의 두께, 열원의 주기, 그리고 열원의 반경이 온도분포에 미치는 영향을 알아보았다. Pulsed laser에 의하여 가열되는 불투명 고체의 시간에 따른 온도는 전체적으로 증가하지만 열원의 주기와 동일한 주기를 가지고 일정한 온도차를 가지는 전체온도와 평균온도의 차, Tac가 존재한다. 열확산계수가 증가하면 재료 내부로 에너지의 확산이 활발하기 때문에 Tac는 커진다. 재료의 두께가 열확산길이보다 얇은 경우에는 두께변화에 따라서 온도가 민감하게 변하지만, 열확산길이보다 재료의 두께가 두꺼울 때는 두께의 변화에 관계없이 거의 일정한 온도가 나타난다. 열원의 단속주파수가 증가하면 한 주기당 에너지가 작아지므로 Tac의 크기는 작아진다. 열원의 반경이 커지면 단위면적당 에너지가 감소하므로 Tac의 크기는 삼각파, 싸인파, 사각파 순으로 크게 나타난다. 따라서 열원의 파형을 측정하여 이를 적용하는 것이 바람직하다.

  • PDF

LPG Dispensing Control System (LPG 충전 제어시스템)

  • 이상훈;최병철;박남철
    • Proceedings of the KAIS Fall Conference
    • /
    • 2000.10a
    • /
    • pp.113-113
    • /
    • 2000
  • LPG 및 석유류는 온도에 따라서 유량의 변화가 LPG의 경우는 ±0.23%/℃, 무연은 ±0.11%/℃, 등유는 ±0.10%/℃, 경유의 경우는 ±0.09%/℃로 특히 LPG의 경우가 그 변화가 심하므로 정확한 충전량을 계량하는 것이 중요하다. 이는 공정거래 확립의 차원에서 공급자와 소비자 입장에서 반드시 요구되는 사항이다. 이를 위해 본 논문에서는 LPG 충전기의 충전제어 및 자동 온도 보정의 알고리즘을 개발하고 이를 프로그래밍한 후 온도센서와 16-bit 마이크로프로세서(intel 80C196)로 자동 온도 보정이 가능한 LPG 충전기의 충전제어 시스템을 설계 및 제작하였다. 설계 제작된 시스템은 프로세서부, I/O 입ㆍ출력부, VFD(vacuum fluorescent display) 디스플레이 구동부로 구성된다. 충전제어 동작은 LPG 유량계의 encoder로부터의 유량(유속)신호와 기차 보정값 및 15℃를 기준으로 한 온도 센서부의 온도 보정값을 입력받아 솔레노이드 밸브를 제어하여 충전을 제어하게 된다. 온도 보정은 80C196 프로세서의 내부 10-bit A/D 변환기를 사용하여 0.5℃ 분해능으로 온도제어를 할 수 있다. VFD 디스플레이는 유량, 금액, 단가가 표시되며 그 값을 누적시켜 일계, 월계를 알 수 있게 하였다. 그 외에 시스템 진단기능 및 컴퓨터통신, POS 통신이 가능하도록 하였다. 제작된 시스템을 LPG 충전기에 실장하여 시험한 결과 목표한 정확도로 유량이 제어됨을 알 수 있었다.

Experimental Study on the Determination of Heat Transfer Coefficient for the KURT (KURT 내 열전달계수 결정에 관한 실험적 연구)

  • Yoon, Chan-Hoon;Kwon, Sang-Ki;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.19 no.6
    • /
    • pp.507-516
    • /
    • 2009
  • In cases of high-level radioactive waste repositories, heat load is apparent by radioactive waste decay. The safety of a waste repository would be influenced by changing circumstances caused by heat transfer through rock. Thus, a ventilation system is necessary to secure the waste repository. The first priority for building an appropriate ventilation system is completing a computer simulation research with thermal rock properties and a heat transfer coefficient. In this study, the heat transfer coefficient in KURT was calculated using the measurement of inner circumstance factors that include dry bulb and wet bulb temperature, rock surface temperature, and barometric pressure. The heater that is 2 m in length and 5 kw in capacity heats the inside of rock in the research module by $90^{\circ}C$. As a result of determining the heat transfer coefficient in the heating section, the changes of heat transfer coefficient were found to be a maximum of 7.9%. The average heat transfer coefficient is approximately 4.533 w/$m^2{\cdot}K$.

A study on temperature dependent acoustic receiving characteristics of underwater acoustic sensors (수중음향센서 수온 변화에 따른 음향 수신 특성 변화 연구)

  • Je, Yub;Cho, Yohan;Kim, Kyungseop;Kim, Yong-Woon;Park, Saeyong;Lee, Jeong-Min
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.2
    • /
    • pp.214-221
    • /
    • 2019
  • In this paper, a temperature dependent acoustic receiving characteristics of underwater acoustic sensor is studied by theoretical and experimental investigations. Two different types (low mid frequency sensor and high frequency sensor) of underwater acoustic sensors are designed with different configuration of baffle and conditioning plate. The temperature dependent characteristics of the acoustic sensors are investigated within the temperature range from $-2^{\circ}C$ to $35^{\circ}C$. The material properties of the piezoelectric ceramics, molding and baffle, which are the primary materials of the acoustic sensors, are measured with temperature change. The temperature dependent RVS (Receiving Voltage Sensitivity) characteristics of the acoustic sensors are simulated by using the measured material properties. The RVS changes of the acoustic sensors are measured by changing temperature in the watertank where the acoustic sensors are installed. The measured and the simulated data show that the temperature dependent characteristics of the acoustic sensors are mainly dependent for the sound speed changes of the molding material.

Relaxation Behavior of Thermo-Plastic Elastomers

  • 도문석;이한섭;서승원
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 1998.10a
    • /
    • pp.203-206
    • /
    • 1998
  • 열가소성 탄성체(Thermoplastic elastomers)의 일종인 polyurethane은 상온보다 높은 유리전이온도(T$_{g}$)를 갖는 hard segment(HS)와 낮은 T$_{g}$를 갖는 soft segment(SS)간의 열역학적 불친화성으로 인해 미세 상분리 구조를 갖는다. SS는 낮은 T$_{g}$로 인해 상온에서 rubbery한 성격을 나타내며 HS는 높은 T$_{g}$로 인해 물리적 가교 역할과 충진제 역할을 한다. Polyurethane은 중합당시의 조성이나 중합방법에 따라 다양한 내부구조를 갖으며 이런 내부구조의 변화에 따른 물리적 성질의 변화 역시 다양하다. (중략)

  • PDF

Development of a curling pad performance test system to support Korea curling team (국가대표 컬링 대표팀 지원을 위한 컬링 패드 성능 시험 시스템 개발)

  • Kim, Taewhan;Lee, Sangcheol;Kil, Sekee
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.25-30
    • /
    • 2020
  • In this study, a test system which can test performance of curling pad was developed to support Korea curling team. The developed system consists of a water tank, a mechanical pad driving system that can perform sweeping movement using a curling pad on surface of ice made by the water tank, and temperature sensors monitoring ice and air temperatures. To control the temperature of ice and humidity/temperature of air around the ice, all system are installed in a chamber that can isolate the developed system from external environment. Eight kinds of curling pads were tested using the developed system. Test result showed that each curling pad revealed different rate of ice temperature increasing. The pad with the highest rate of ice temperature rising was found to be the same as the most preferred pad by the athletes. Therefore, it was confirmed that the method of measuring change of ice temperature by the sweeping performed in this study is an effective method to test the performance of the pad.

Corrosion Resistance of Al-Mg Coated Steel Sheets by E-beam deposition (전자빔 증착에 의해 제조된 Al-Mg 코팅 강판의 내부식 특성)

  • Yang, Ji-Hun;Jeong, Jae-Hun;Song, Min-A;Kim, Seong-Hwan;Jeong, Jae-In
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.54-54
    • /
    • 2014
  • 전자빔 증착을 이용하여 알루미늄(Al)과 마그네슘(Mg)의 2층 구조를 갖는 박막을 강판 위에 코팅한 후 열처리를 실시하여 박막의 미세구조 변화와 합금상을 관찰하고 Al-Mg 코팅 강판의 내부식 특성을 평가하였다. 이를 통해서 Al-Mg 박막의 미세구조와 합금상이 Al-Mg 코팅 강판의 내부식 특성에 미치는 영향을 확인하였다. Al-Mg 박막의 조성은 Al 박막과 Mg 박막의 두께 변화를 이용하여 조절하였으며 Al-Mg 박막의 두께비는 각각 1:1(Al:Mg), 2:1, 5:1 이었다. 열처리 온도는 $400^{\circ}C$, 열처리 시간은 2, 3, 10분 이었다. Al-Mg 코팅 강판은 열처리를 실시하면 주상구조에서 치밀한 구조로 변화하였으며 Al-Mg 합금상이 생성되었으며 합금상은 $Al_3Mg_2$$Al_{12}Mg_{17} $ 이었다. 이러한 합금상의 생성으로 Al-Mg 박막의 미세구조가 변화하고 Al-Mg 코팅 강판의 내식성에도 영향을 미친 것으로 판단된다.

  • PDF

Estimation of Frost Penetration Depth of Paved Road with Field Temperature Data (도로포장 현장 온도데이터를 이용한 동결심도 추정 연구)

  • Lee, Jae-Sik;Cho, Gyu-Tae
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.82-82
    • /
    • 2011
  • 현재 도로 포장 설계시 동결심도의 결정은 30년간 관측한 기상자료 분석을 통해서 얻은 동결지수를 근거로 하여 동결심도를 산정한다. 그러나 기후 온난화 현상 등 변화된 기상조건과 대기온도를 근거로 작성된 동결지수와 대기온도에 따른 실제 포장 내부의 온도 변화를 반영하지 못하고 있다. 따라서, 본 연구에서는 설계시 산정된 동결심도와 실제 현장의 동결심도의 차이를 확인하기 위하여 한반도 북부지역을 동결지수에 따라 동결지수 $550{\sim}650^{\circ}C{\cdot}$일, $450{\sim}550^{\circ}C{\cdot}$일, $350{\sim}450^{\circ}C{\cdot}$일, $350^{\circ}C{\cdot}$일 이하로 구분하여 15개 지역을 선정하였고, 각 지역별로 절토부, 절성경계부, 저성토부(2m 이하 성토부) 구간으로 45단면을 구분하여 현장계측시스템을 구축하였다. 그리고 현장계측시스템으로부터 얻어진 대기온도와 포장층별 온도를 이용하여 현장 동결심도를 산정하고 동결심도 산정식의 동결심도와 비교하였다. 또한, 현장 동결심도를 이용하여 동결심도선도를 작성하였다.

  • PDF

Anti-condensation System for Switchboard sing the ATmega128 (ATmega128을 이용한 배전반의 결로 방지 시스템 구현)

  • Youn, Jung-Ho;Oh, Kab-Suk
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11a
    • /
    • pp.329-331
    • /
    • 2010
  • 전력회사로부터 공급되는 전력을 분배하고 제어하는 기능을 갖는 배전반은 아파트를 비롯한 대단위 인구밀집 주택 지역과 고압 변전소 등에 설치된다. 배전반에 수용되는 전력설비의 사고는 전력 기기의 열화에 의한 사고, 접점 및 각 연결 부위의 접촉 불량에 의한 과열 현상 등에 의한 사고 등으로 구분할 수 있으며 과열 현상에 의한 사고의 원인 중의 하나는 배전반 천정면의 결로에 의한 것으로, 물방울이 각종 기기에 직접 접촉하여 폭발하는 사고로 연결된다. 배전반의 결로는 일중 온도가 급격한 변화를 보이는 계절이나 지역에서 배전반 내부와 외부의 온도 차이와 내부 습도에 의해 발생한다. 본 논문에서는 온도와 습도의 단순 비교를 통하여 환풍기, 열풍기, 환기 등을 제어하여 결로를 해결하는 기존의 방식을 개선하여, 노점온도 계산에 의한 히터 구동 방안을 제시한다.

  • PDF