• Title/Summary/Keyword: 날림

Search Result 50, Processing Time 0.022 seconds

Study on the characteristics of laminar lifted flames using planar laser induced fluorescence technique (평면 레이저유도 형광법을 이용한 부상화염의 특성 연구)

  • Lee, Byeong-Jun;Jeong, Seok-Ho;Han, Jae-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.11
    • /
    • pp.1393-1402
    • /
    • 1997
  • Characteristics of the lifted flame which is generated by issuing of the fuel through the miniature nozzle, d = 0.164 mm, are studied using the planar laser induced fluorescence technique. OH radical is excited on the $Q_{1}$(8) line of the $A^{2}$.SIGMA.$^{+.leq.X2}$ .PI.(1, 0) band transition (283.55 nm) and LIF signals are captured at the bands of (0, 0) and (1, 1) transition (306 ~ 326 nm) using the filters and ICCD camera. Hydroxyl radical (OH) profile for nozzle attached flame shows that OH radical populations at the flame sides and flame tip are larger than those at the base. But for the lifted flame (tribrachial flame) case, those are larger at the flame base than at the flame tip and flame sides. The OH radical is more dense near the center line of flame base at the blowing out. This fact proves the Chung and Lee's blowout theory-blowout occurs when the flame is anchored at the flame axis. axis.

Characteristics of Premixed Flames in a Double Concentric Burner (이중 동축류 버너에서의 예혼합화염 특성에 관한 연구)

  • Gwon, Seong-Jun;Cha, Min-Seok;Choe, Man-Su;Jeong, Seok-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.12
    • /
    • pp.1662-1669
    • /
    • 2000
  • Various flame types are observed in a double concentric burner by varying equivalence ratio and flow rates in each tube. Observed flame types include bunsen-type flame, ring-shaped flame, outer lifted flame, inner lifted flame, and oscillatory lifted flame, The doman of existence of various flames is mapped with equivalence ratio and annular jet velocity. Each flame is investigated through direct photography and OH PLIF. As central air velocity increase, the blowout region is diminished and lifted oscillating flames are observed. Inner lifted flames are observed from bunsen flames or rich shaped flames by increasing central air velocity. For inner lifted flames, annular jet velocity, at flame liftoff decreases with increasing central air jet velocity. Axial velocity profile and temperature fie이 using LDV and CRS, respectively, for a typical inner lifted flame are also measured through which the role of tribrachial flame for stabilization in emphasized.

The Effect of Swirl on the Blowout Velocities of Partially Premixed Interacting Flames (스월이 부분예혼합 상호작용화염의 화염날림 유속에 미치는 영향)

  • Lee, Byeong-Jun;Choi, Kwang-Deok
    • Journal of the Korean Society of Combustion
    • /
    • v.14 no.2
    • /
    • pp.26-31
    • /
    • 2009
  • Adding small amounts of air to the fuel is used in many commercial combustors to avoid sooty flame. But partially premixed jet flame has lower blowout velocity, $u_{b.o}$, than nonpremixed one. Increasing blowout limit would be one of the key factors to develope highly intense compact combustion devices. Swirling flow enhances fuel and air mixing and induces a highly turbulent recirculation zone, which helps flame stabilization. It was known that NOx emission decreases with swirl on the proper range of swirl number. And it was shown that the flame interaction in multiple jets also increases $u_{b.o}$ owing to the internal recirculation and reduces NO emission. If the effects of swirl and flame interaction are combined together in partially premixed flame, both $u_{b.o}$ increasement and NOx emission reduction could be achieved. Blowout limits of partially premixed interacting propane flame in the swirling air coflow are investigated experimentally. The results show that the flame is not extinguished up to the experimental limits, 210 m/s, at the swirl number of 0.32 and $X_{F,o}$ = 0.46.

  • PDF

A study on the Automatic Generation of the Freehand Style Fonts with parameters (매개변수를 가지는 한글 필기체 폰트의 자동 생성에 관한 연구)

  • Lee, D.R.;Lee, D.H.;Park, H.S.;Cho, H.G.
    • Annual Conference on Human and Language Technology
    • /
    • 1992.10a
    • /
    • pp.581-590
    • /
    • 1992
  • 고품위 입출력 장치의 급속한 발달과 전자 출판 시스템의 출현은 더 다양한 서체를 요구하게 되었다. 컴퓨터에서 사용되고 있는 한글 서체는 명조, 고딕체를 제외하고는 주로 장식용 폰트를 만들어 사용하고 있다. 본 논문에서는 Cubic B-Spline 곡선을 이용하여 다양한 필기체 폰트를 구현하였고, 필기체가 가지는 특성(날림의 정도, 글자의 기울이기 정도, 각 음소의 크기, 각 글자의 크기의 균일성 등)에 따라 인자를 부여하여 개별화되고 사실적인 폰트를 생성하였다. 각 인자의 조합은 암호화되어 각 개인의 폰트로 부여된다. 즉, 개인의 고유 폰트는 폰트 암호(password)로 부여되고, 제어인자는 폰트암호의 해쉬값에 의해 선택되며, 사용자들로부터 이 제어인자들을 숨기게 되면 각 사용자들의 폰트는 유일하고, 안전하게 되므로, 일정정도의 안정성이 보장된다고 보여진다. 그리고 본 연구에서 구현된 폰트는 한글 필기체 문자인식의 정도를 측정하는 다양한 데이타를 제공하는 데에도 의미가 있다.

  • PDF

Measures to Reduce Mine Hazards Caused by Open- cut Mining of Limestone Mines (석회석광산에서 노천채굴에 따른 광해 발생을 감소시키기 위한 대책)

  • Won, Yeon-Ho;Ah, Jin-Man
    • Explosives and Blasting
    • /
    • v.24 no.2
    • /
    • pp.75-82
    • /
    • 2006
  • Most of limestone mines in Korea have been developed by a open-cut mining method in consideration of a deposited condition of ore, ore recovery, safety, economic efficiency, etc.. But it has produced environmental problems such as dust flying, blasting noise & vibration, and spoil of farmlands due to slope failure of waste rock mass caused by access road construction, fragmentation & crush of rocks, blasting, transportation, and mineral processing. In this study, it has been suggested for measures to reduce mine hazards caused by open- cut mining of limestone nines.

A Study on Development of an Automatic Spreading System of High-concentration Flux for a Nocolok Brazing Furnace (NBF 고농도 플럭스 자동 도포 장치 개발에 관한 연구)

  • Lee, Young-Lim;Hwang, Soon-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.1108-1114
    • /
    • 2010
  • Nocolok brazing requires flux at the joining area and low-concentration flux is uniformly spreaded to products to be brazed in a chamber. However high-concentration flux needs to be applied only to a necessary spot. In general, high-concentration flux is manually applied for conventional brazing furnaces, resulting in low production efficiency and harmful environments for workers due to particles and heat etc. Therefore an economical and efficient automatic spreading system needs to be developed. In this study, an efficient automatic spreading system of high-concentration flux was successfully developed and tested with a NBF.

Characteristics of Autoignited Laminar Lifted Flames in Heated Coflow Jets of Carbon Monoxide/Hydrogen Mixtures (일산화탄소/수소 혼합기의 가열된 동축류 제트에서 자발화된 층류 부상화염의 특성)

  • Choi, Byung-Chul;Chung, Suk-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.6
    • /
    • pp.639-646
    • /
    • 2012
  • The characteristics of autoignited lifted flames in laminar jets of carbon monoxide/hydrogen fuels have been investigated experimentally in heated coflow air. In result, as the jet velocity increased, the blowoff was directly occurred from the nozzle-attached flame without experiencing a stabilized lifted flame, in the non-autoignited regime. In the autoignited regime, the autoignited lifted flame of carbon monoxide diluted by nitrogen was affected by the water vapor content in the compressed air oxidizer, as evidenced by the variation of the ignition delay time estimated by numerical calculation. In particular, in the autoignition regime at low temperatures with added hydrogen, the liftoff height of the autoignited lifted flames decreased and then increased as the jet velocity increased. Based on the mechanism in which the autoignited laminar lifted flame is stabilized by ignition delay time, the liftoff height can be influenced not only by the heat loss, but also by the preferential diffusion between momentum and mass diffusion in fuel jets during the autoignition process.

A Study on the Risk Assessment Occurred Possibly in a Civil Project (토목공사에서 발생 가능한 리스크평가에 관한 연구)

  • Yoon, Yong-Kyun
    • Explosives and Blasting
    • /
    • v.29 no.2
    • /
    • pp.59-66
    • /
    • 2011
  • A variety of risks caused by natural, technological and biological hazards threaten a business continuity of an organization. Business continuity is very important issue for all organizations and its proper management may control success and failure of an organization. Business continuity plan (BCP) may be defined as a management process which provides a business continuity. BCP includes risk management, operational continuity plan, response/ recovery, exercise/study and crisis communication, etc. Risk management is a systematic method to identify, analyze, evaluate and treat emergency risks and risk assessment is composed of identifying, analyzing and evaluating emergency risks. Risk assesment is the first step for making BCP. In this study, risk assessment has been conducted for sewer laying project. Through assessing risks, 18 risks that may threaten the construction operation are identified and it is founded to be that high levels of risks which require treatment are 'collapse of excavation surface', 'breakage of ground infra-facilities', 'noise & dust dispersion' and 'rise of material costs'.

Quantitative Difference in the Extinguishing Concentration of Inert Gases with Fire Suppression Criteria in a Cup Burner Test (컵버너시험에서 소화기준에 따른 불활성기체의 소화농도에 대한 정량적 차이)

  • Cho, Jae-Ho;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.34-42
    • /
    • 2014
  • The concentrations of inert gases ($N_2$, Ar, $CO_2$ and He) required to induce the flame instabilities such as swing, rotation, lifted and blow-out were measured in a cup burner nonpremixed flames for $CH_4$ and $C_3H_8$ fuels. Quantitative differences in the extinguishing concentration with fire suppression criteria (i.e. blow-out or onset of flame instability) were also examined. It was found that the difference in extinguishing concentration was increased with the appearance of lifted flame and the low extinguishing performance of inert gaseous. The maximum difference in extinguishing concentration with the suppression criteria was approximately 35% at the highest fuel velocity condition (1.3 cm/s) for the $C_3H_8$-air nonpremixed flame. It can be also expected that the extinguishing concentration by the criteria based on the onset of flame instability will provide the useful information from the viewpoint of the accurate and economical design concentration.

Development of Parasol Device at Convenience Harvest Product for Chilli and Bare Ground Vegetable (고추 및 노지채소 수확작업 편이장치의 해가림 장치개발)

  • Jang, SukGeun;Kim, JiMan;Choi, Hwon;Kim, Yeoungsu;Oh, Sungkil;Lim, HackKyu;Kim, TeaHan
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.64-64
    • /
    • 2017
  • 노지 고추 수확작업은 7~9월에 걸쳐 5~6회 수행되며 가장 더운 한 여름의 태양볕에 노출되어 장시간 수확작업을 하며 노지채소 및 고추 수확작업시 자외선 과다 노출되어 악성흑생종, 광선각화증, 편평세포 암 및 각종 피부암발생의 원인되기 때문에 적절한 해가림 장치의 설계가 필요하다. 해를 가려주는 장치에 사용되는 재질로는 우산 및 양산에 널리 사용되어지는 섬유로 폴리에스테르를 선정하였으며 두께로 우산의 재질로 많이 사용되는 75 denier을 채택하였다. 코팅의 종류로는 Foam, Milky, Silver, 폴리우레탄을 채택하여 섬유의 코팅 종류에 따른 차단 효과를 실험하였다. 실험 방법으로서는 KS K 0850 텍스타일의 자외선 차단율 및 차단지수 시험방법에 의거 하여 실험하였다. 자외선 UV-A(365n/m), UV-B(315n/m) 측정장치는 자외선 센서, UV램프, 인디케이터로 구성된 측정기를 이용하였으며 각 재료별 5회 반복 실시하여 평균치를 산출 하였다. UV-A(365n/m) 측정값으로는 FOAM, MILKY코팅이 된 섬유재질이 KS의 우산 및 양산품질표시기준에 부합하여 해가림 장치에 사용이 적절하였으며 UV-B(315n/m) 파장 차단율 측정값으로는 KS의 우산 및 양산품질표시기준에 모두 부합되었다. 또한 해가림 장치는 태양고도에 따라 각도를 조절 가능한 형태로 설계하였으며 직사광선이 가장 강한 시간대인 10시부터 12시를 기준하여 틸팅의 최대 각도는 20도로 개발하였다. 또한 바람에 의한 날림현상을 방지하고 통풍효과를 높이기 위해서 해가림 장치의 섬유를 2중 구조로 설계하여 바람의 순환이 되게하였다.

  • PDF