• Title/Summary/Keyword: 난분해성 유기물제거

Search Result 44, Processing Time 0.028 seconds

오존 전처리 공정이 생물활성탄 공정의 효율에 미치는 영향

  • Lee, Sang-Hun;Mun, Sun-Sik;Sin, Jong-Cheol;Choe, Gwang-Geun;Park, Dae-Won;Sim, Sang-Jun;Lee, Jin-Won
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.361-364
    • /
    • 2002
  • BAC (biological activated carbon) process is a combination of biodegradation and active carbon adsorption. Pre-ozonation of raw water increased in biodegradable organic fraction. This study is to investigate the enhancement of dissolved organic matter removals by pre-ozonation process combined with BAC process at a semi-pilot scale. By biodegradation improvement in pre-ozonation process. the charge of adsorption was reduced and the life of biological activated carbon is extended. And, 48 % of total DOC was remove in the upper compartment of BAC column. The removal of the nitrogen-ammonia shows a considerably high removal ratio with 75.9 %.

  • PDF

Effective Chemical Treatment of Biologically Treated Distillery Wastewater in Industrial Scale (생물학적으로 처리한 주정폐액의 효율적인 화학적 처리방법)

  • Nam, Ki-Du;Chung, In;Hur, Daniel;Park, Wan
    • Journal of Life Science
    • /
    • v.9 no.6
    • /
    • pp.692-697
    • /
    • 1999
  • For further removal of non-biodegradable CODs and color in biologically treated distillery waster water, we selected a chemical treatment with Fe(III) and cationic polymers and then another chemical treatment with Fenton reagent. We developed Pregenerated Bubble Flotation(PBF) to effectively remove the chemical sludge from each chemical reaction process. The flotation unit was constructed with hydraulic loading rate, 7 ㎥/$m^2$.hr. The CODMn and suspended solids (SS) in biologically treated distillery waste water were reduced by the first PBF from 310-1096 mg/L to 141-303 mg/L and from 160-990 mg/L to 48-385 mg/L, respectively. Again, after the Fenton reaction process, floated SS was skimmed off at the top of the flotation unit and the final effluent was directly discharged without any tap water dilution. The quality of final effluent can be below 40 mg/L-CODMn but IISan Distilery has been maintained effluent quality of 73 mg/L-CODMn and 10-80 mg/L-SS. The chemical cost was saved by more than 30% as compared with that of prior process.

  • PDF

Application of Iron-Catalyzed Air Oxidation Process for Organics and Color Removals in Recalcitrance Flexographic Inks Wastewater (난분해성 후렉소잉크 폐수중 유기물 및 색도제거를 위한 철촉매 공기산화 공정의 적용)

  • Cho, Yong Duck;Yoon, Hyon Hee;Park, Sang Joong;Kim, Jong Sung;Lee, Sang-Wha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.4
    • /
    • pp.487-498
    • /
    • 2006
  • The oxidation processes of metal catalysis were practically applied into the flexographic inks wastewater treatment to derive the most effective and economical system among all the processes of iron-salts coagulation, iron-catalyzed air oxidation, and coagulation followed by biological treatment. The iron concentration and pH were optimized as $2.8{\times}10^{-3}mol$ and 5.5~6.0, respectively, for all the oxidation processes. At the optimal reaction conditions, the removal efficiencies of $TCOD_{Mn}$ and Color were as follows for the respective process: i) 75% $TCOD_{Mn}$ and 77% Color removals for iron-salts coagulation, ii) 91% TCODMn and 90% Color removals for iron-catalyzed air oxidation, iii) 74~92% $TCOD_{Mn}$ and 81~90% Color removals for coagulation followed by biological treatment. Based on the economical and technological aspects, iron-catalyzed air oxidation was confirmed as the most effective process in the treatment of industrial wastewater.

Leachate Treatment using Intermittently Aerated BAC-Fluidizing Bed (간헐폭기 생물활성탄 유동상에 의한 매립지침출수 처리)

  • Kim, Kyu Yeon;Lee, Dong Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.13 no.4
    • /
    • pp.136-147
    • /
    • 2005
  • Leachate from landfill sites contains high organics, chloride and ammonium nitrogen in concentration which might be potentially major pollutants to surface and groundwater environment. Most of landfill leachate treatment plants in Korea consist of biological processes to remove BOD and nitrogen. However, the efficiencies of refractory organics removal, nitrification and denitrification have not met frequently the national effluent regulation of wastewater treatment facility, especially in winter season. Simultaneous removal of organics and nitrogen from leachate is strongly necessitated to meet the national regulation on effluents from leachate treatment facilities. The intermittently aerated biological activated carbon fluidized bed(IABACFB) process was applied to treat real landfill leachates containing refractory organics and high concentration of ammonium nitrogen. The IABACFB reactor consisted of a single bed in which BAC fluidizing and an aerating column. The fluidized bed is intermittently aerated through the blower located at the aerating column. Experiments were performed to evaluate the applicability of Intermittently Aerated BACFB for simultaneous removal of refractory organic carbon and ammonium nitrogen of leachate. Organics and ammonia nitrogen($NH{_4}{^+}-N$)are oxidized during the aerobic stage, and nitrite-nitrate nitrogen($NO{_x}{^-}-N$) are removed to nitrogen gas through denitrification reaction during anoxic state. The IABACFB reactor condition reached a steady state within 40 days since the reactors had been operated. The blowing mode of 60 min.-On/60 min.-OFF is more compatible to remove TOC and ($NH{_4}{^+}-N$) operated. The blowing mode of 60 min.-On/60 min.-OFF is more compatible to remove TOC and ($NH{_4}{^+}-N$) simultaneously than the mode of 30 min.-On/90 min.-OFF. The average removal efficiencies of TOC, the refractory organic carbon, and the average efficiencies of nitrification and denitrification were 90%, 75%, 80%, 95%, respectively.

  • PDF

The Effect of Solubilization Pretreatment Process on Anaerobic Digestion of Waste Activated Sludge (전처리 가용화 공정이 잉여슬러지 혐기성 소화효율에 미치는 영향)

  • Yoo, Ho-Sik;Ahn, Seyoung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.3
    • /
    • pp.35-43
    • /
    • 2016
  • COD properties of waste activated sludge (WAS) were investigated for various solubilization rate of mechanical pretreatment method in anaerobic digestion process. Inert COD was 37.0% of total COD in untreated WAS. Particulate biodegradable COD was converted to soluble biodegradables and particulate unbiodegradables as solubilization was processed. Particulate unbiodegradable portion of COD in WAS can be increased as particulate biodegradable portion is decreased in case of relatively long SRT of biological treatment. Thus, COD properties of WAS should be investigated in case of relatively low particulate biodegradable COD, because of possible low effect of solubilization. COD removal rate in anaerobic digester was enhanced as much as 2.1% and 15.1% for solubilization rate 5% and 35% due to pretreatment, respectively. COD removal rate was increased from 25% to 40%, and methane gas generation was increased from $607m^3/d$ to $907m^3/d$ as particulate COD of WAS was solubilized to 35% in pretreatment facilities.

Biological Treatment of Dyeing Wastewater Using Jet Loop Reactor with Activated Carton Supports (활성탄 담체가 포함된 Jet-Loop Reactor를 이용한 종합염색폐수처리)

  • 조무환;박종탁;이길호;류원률
    • KSBB Journal
    • /
    • v.17 no.3
    • /
    • pp.241-246
    • /
    • 2002
  • Today, many problems of dye-processing wastewaters were raised due to industry of dyeing and textiles. It is difficult to treat them perfectly because they contain many poorly degradable matters, such as surfactants, ethylene glycol, polyvinyl alcohol, and so on. To improve the performances of conventional physicochemical treatment and activated sludge process, new systems of combining jet-loop reactor (JLR) with physicochemical treatment were developed. Volumetric oxygen transfer coefficient ($k_{L}a$) of JLR was significantly larger than that of air-lift reactor. Also, for the effective treatment of dye-processing wastewater, JLR with active carbon supports (JLRAS) were investigated. Removal efficiency of BOD, $COD_{Mn}$, $COD_{Cr} and color were found as 99, 86, 84, 83%, respectively, when HRT was 8 hrs. And performance of JLRAS was rapidly restored after step change of $COD_{Mn}$ loading late. The optimal coagulant and dosage of second physicochemical treatment after JLRAS were polyferric sulfate and 130 mg/L, respectively, when removal efficiencies of $COD_{Mn} and color were 85 and 73%, respectively. In conclusion, this system enables the reduction of operation cost, and the effective removal of many organics.

Treatment of Textile Wastewater by Membrane-Bioreactor Process (막-생물반응조 공정을 이용한 염색폐수의 처리)

  • 강민수;김성수;황규대;강종림
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.10a
    • /
    • pp.60-61
    • /
    • 1996
  • 염색폐수를 처리하기 위하여, 일반적으로 물리.화학적 공정과 호기성 생물학적 공정을 조합한 방법들을 사용하고 있다. 하지만 호기성 생물학적 공정은 난분해성 물질의 제거능력이 낮고, 염색폐수의 주된 오염원인 염료분자가 호기성 미생물에 대한 에너지원으로 적합하지 않아 분해되기 어려우며, 물리.화학적 공정을 이용한 처리방법으로도 높은 처리효율을 얻을 수가 없다. 이러한 문제점을 극복하기 위하여 염색폐수 처리에 혐기-호기공정을 이용하며, 혐기성 공정에서 생물학적으로 분해되기 어려운 고분자 물질들을 가수분해하여 생물학적으로 분해가능한 저분자물질로 전환시키고, 호기성 공정에서 저분자 물질을 효과적으로 처라할 수 있기때문에 기존의 염색폐수 처리공정에 비하여 훨씬 높은 처리효율을 얻을 수 있다. 특히, 혐기성 미생물은 호기성 미생물에 비하여 난분해성 물질에 대한 분해력이 높고, 생물독성 물질에 대한 내성이 강하기 때문에 수중생물에 유해한 염료를 함유한 염색폐수의 색도제거에 효과적인 것으로 기대된다. 또한, 막분리 공정은 유기물 및 미생물이 막표면에 축적, 증식함으로써 막세공에 막힘현상을 초래하여 역세척 등의 물리적인 방법이나 화학약품을 이용한 화학적 세척 방법으로도 투과플럭스의 회복이 불가능한 상태를 유발함으로 막의 수명을 단축시키는 원인이 된다. 따라서, 혐기-호기공정과 조합하면 색도성분 제거 및 막 오염의 원인이 되는 유기물 및 용존성 고형물을 제거하고, 막 오염의 억제를 통한 후 수염의 연장은 물론, 처리수의 수질향상에 활용될 수 있을 것으로 사료된다.1로 강구와 함께 공구강 vial에 장입 후, Spex mixer/mill을 이용하여 기계적 합금화 하였다. 기계적 합금화 공정으로 제조한 분말에 대한 X-선 회절분석과 시차 열분석으로 합금화 정도를 분석하였다. (Bi1-xSbx)2Te3 및 Bi2(Te1-ySey)3 합금분말을 10-5 torr의 진공중에서 300℃∼550℃의 온도로 30분간 가압소결하였다. 가압소결체의 파단면에서의 미세구조를 주사전자현미경으로 관찰하였으며, 상온에서 가압소결체의 열전특성을 측정하였다. (Bi1-xSbx)2Te3의 기계적 합금화에 요구되는 공정시간은 Sb2Te3 함량에 따라 증가하여 x=0.5 조성에서는 4 시간 45분, x=0.75 조성에서는 5 시간, x=1 조성에서는 6 시간 45분의 vibro 밀링이 요구되었다. n형 Bi2(Te1-ySey)3 합금분말의 제조에 요구되는 밀링시간 역시 Bi2Se3 함량 증가에 따라 증가하였으며 Bi2(Te0.95Se0.05)3 합금분말의 제조에는 2시간, Bi2(Te0.9Se0.1)3 및 Bi2(Te0.85Se0.15)3 합금분말의 형성에는 3시간의 bivro 밀링이 요구되었다. 기계적 합금화로 제조한 p형 (Bi0.2Sb0.8)2Te3 및 n형 Bi2(Te0.9Se0.1)3 가압 소결체는 각기 2.9x10-3/K 및 2.1x10-3/K 의 우수한 성능지수를 나타내었다.ering)가 필수적이다. 그러나 침전법에서 얻게 되는 분말은 매우 미세하여 colloid를 형성하게 되며, 이러한 colloid 상태의 미세한 침전입자가 filte

  • PDF

Advanced Treatment of Sewage and Wastewater Using an Integrated Membrane Separation by Porous Electrode-typed Electrolysis (분리막/다공 전극형 전기분해 조합공정을 이용한 하.폐수의 고도처리)

  • Choi, Yong-Jin;Lee, Kwang-Hyun
    • Membrane Journal
    • /
    • v.22 no.2
    • /
    • pp.95-103
    • /
    • 2012
  • To treat nitrate and non-biodegradable organics effectively in sewage, industrial wastewater and livestock wastewater, the activated sludge process integrated by a membrane separation and a porous electrode- electrolysis was proposed and its efficiency was investigated. The proposed system was consisted of 3 processes; activated sludge, membrane filtration and electrolysis. In the study, the membrane filtration played a role in reducing the load of the electrolysis to operate the proposed process stably. The electrolysis consisted of a porous electrode to increase the efficiency due to the extension of the specific surface area. Additionally, redox reaction in the electrolysis was induced by decomposing influent water as current was applied. As a result, hydrogen free radicals and oxygen radicals as intermediates were produced and they acted as oxidants to play a role in decomposing non-degradable organics. It was environmentally-friendly process because intermediates produced by porous electrode were used to treat waste matters without supplying external reagent. Experimental data showed that the proposed process was more excellent than activated sludge process. SS removal efficiencies of the proposed process, membrane filtration and activated sludge process were about 100%, about 100% and about 90%, respectively. COD removal efficiencies of the proposed system, membrane filtration and activated sludge process were about 92%, about 84% and about 78%, respectively. T-N removal efficiencies of the proposed system, membrane filtration and activated sludge process were about 88%, about 67%, and about 58%, respectively. The SS data showed that SS was efficiently removed in the single of the membrane filtration. The COD/T-N data showed that COD/T-N of membrane hybrid process was treated by removing a little soluble organics and SS, and that COD/T-N of electrolysis hybrid process was treated by oxidize organics with high removal rate.

Treatment of Wastewater Containing Ethanolamine in Secondary System of Nuclear Power Plant (Ethanolamine이 포함된 원자력발전소 2차계통 폐수처리)

  • Lee, Han Chul
    • Applied Chemistry for Engineering
    • /
    • v.24 no.1
    • /
    • pp.38-43
    • /
    • 2013
  • ETA (ethanolamine), a pH control agent, has been used as an ammonia substitute in the secondary system of nuclear power plants since 2001. It is impossible to remove ETA from the wastewater treatment system in the nuclear power plant operating currently, because it is the non-biodegradable organics in terms of the environmental. The optimum process and chemicals for the removal of chemical oxygen demand (COD) & N with the field sample were investigated. More than 95% of Ammonium ions, contained much in wastewater, was removed with a diffused aeration system. COD could be removed over 90% through the process that includes the oxidation with mixed peroxidants (sodium persulfate/sodium percarbonate) followed by the physicochemical treatment with coagulants.

Methodology Development for the Reuse of Sludge Generated from Fenton's Oxidation Process (펜톤산화 공정에서 발생하는 슬러지의 재활용 방안)

  • Koo, Tai-Wan;Cho, Soon-Haing;Choi, Young-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.6
    • /
    • pp.1083-1091
    • /
    • 2000
  • The objective of this study is to develop effective and economical treatment processes for the removal of non-biodegradable organics by reusing the sludge generated from Fenton's Oxidation Process. It was found that about 50% of coagulants and 50% of catalyst can be reduced by reusing the sludge generated from Fenton's Oxidation Process. It was also found that the amount of sludge generation can be reduced in coagulation process and Fenton's Oxidation Process. From the results of bench-scale test, it was found that the average removal efficiency increased to 8.5% and the amount of sludge generation was reduced up to 35% by reusing the sludge as coagulant. The average organic removal efficiency increased to 5.3% and the amount of sludge generation was reduced up to 14% by reusing the sludge as catalyst in Fenton's Oxidation. It can be concluded that the reuse of sludge generated from Fenton's Oxidation Process would be reduced cost of chemical consumption and Fenton's sludge treatment.

  • PDF