• Title/Summary/Keyword: 난방 시간

Search Result 138, Processing Time 0.025 seconds

Energy Saving Effect of a Greenhouse with New Laborsaving Opening & Closing System of Thermal Tunnel Film (보온터널 개폐 생력화 장치를 이용한 온실의 난방에너지 절감 효과)

  • Ryou, Y.S.;Kang, G.C.;Kim, Y.J.;Paek, Y.;Jang, C.H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.07a
    • /
    • pp.255-260
    • /
    • 2002
  • 일반적으로 온실의 효과적인 온도관리를 위해서는 단열효과가 우수한 보온재를 이용하거나 또는 난방공간의 체적을 최소화 할 수 있는 터널재배가 바람직하다. 지금까지는 딸기, 수박 등 키가 작은 작물에 한하여 보온터널재배가 이루어지고 있는 실정이나, 보온터널의 개폐를 인력에 의존하고 있기 때문에 노동력이 많이 들고, 개폐에 소요되는 시간도 상당한 비중을 차지하고 있다. (중략)

  • PDF

Effect of Additional Early-Morning Heating Periods on the Growth and Yield of Cucumber and Heating Load (조조가온기간이 시설재배 오이의 생육과 수량 및 난방부하에 미치는 영향)

  • Kwon Joon Kook;Kang Nam Jun;Lee Jae Han;Kang Kyung Hee;Choi Young Hah
    • Journal of Bio-Environment Control
    • /
    • v.13 no.4
    • /
    • pp.245-250
    • /
    • 2004
  • To investigate the effect of early-morning heating periods on growth and yield of cucumber and heating load in a greenhouse cultivation, three additional heating periods (0, 1 and 2 hours) were compared to rise temperature from $12^{\circ}C\;to\;16^{\circ}C$ in the early-morning. Leaf temperature just before opening the thermal screen was $3.3^{\circ}C\;and\;4.1^{\circ}C$ higher in the 1 and 2 hour heating compared to that in the control (0 hour heating), respectively. Photosynthetic rate, conductance to $H_2O$ and transpiration rate of cucumber leaves were the highest in the 2 hour heating, and the lowest in the control. However. the difference between the 1 hour and 2 hour heating was not significant. Inorganic element content in cucumber leaves was not significant among the treatments of duration. Initial growth after planting of cucumber was greater in the 1 and 2 hour heating than that in the control. Yield increased by $11\%\;and\;15\%$ in the 1 hour and 2 hour heating compared to that in the control. respectively. Fuel consumption for heating increased by $12\%\;and\;22\%$ in the 1 hour and 2 hour heating compared to that in the control, respectively. Considering in the yield and fuel consumption for heating. 1 or 2 hours of early morning heating could be effective in temperature management for cucumber in a greenhouse cultivation.

Effect of Growing Part Following Local Heating for Cherry Tomato on Temperature Distribution of Crop and Fuel Consumption (방울토마토 생장부 추종 국소난방이 군락 온도분포 및 연료소비에 미치는 영향)

  • Kwon, Jin Kyung;Kang, Geum Chun;Moon, Jong Pil;Lee, Tae Seok;Lee, Su Jang
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.217-225
    • /
    • 2015
  • Local heating system providing hot air locally to growing parts including shoot apex and flower cluster which were temperature-sensitive organs of cherry tomato was developed to reduce energy consumption for greenhouse heating without decline of crop growth. Growing part following local heating system was composed of double duct distributer which connected inner and outer ducts with hot air heater and winder which moved ducts up and down following growing parts with plant growth. Growing part local heating system was compared with conventional bottom duct heating system with respect to distributions of air and leaf surface temperatures according to height, growth characteristics and energy consumption. By growing part local heating, air temperature around growing part was maintained $0.9{\sim}2.0^{\circ}C$ higher than that of lower part of crop and leaf surface temperature was also stratified according to height. Investigations on crop growth characteristics and crop yield showed no statistically significant difference except for plant height between bottom duct heating and growing part local heating. As a result, the growing part local heating system consumed 23.7% less heating energy than the bottom duct heating system without decrease of crop yield.

난방운전의 최적제어방안 중심 공동주택의 열성능 향상 방안

  • 이승언;안태경;강재식
    • 월간 기계설비
    • /
    • s.46
    • /
    • pp.74-89
    • /
    • 1994
  • 현재 범국가적 차원에서 지속적인 국가 경제 발전과 국제수지 개선을 위하여 추진되고 있는 정부의 에너지 절약사업에서 건물부문이 차지하는 에너지절약 효과는 막중하다. 특히 전체주택에서 공동주택이 차지하는 비율은 1990년에 32.1$\%$, 서울시의 경우 51.3$\%$로 전체 주택의 과반수를 넘어섰으며, 수도권의 대단위 아파트단지의 개발과 함께 공동주택의 증가추세는 당분간 지속될 전망이다. 본 연구는 공동주택의 최적난방 운전기법 개발을 위한 1차년도의 연구로서 현행 공동주택의 난방운전 실태를 조사, 분석하고 각 난방법에 따른 문제점 및 최적제어 알고리즘의 개발을 위한 자료 도출을 주 목적으로 진행되었다. 1차년도에 수행된 연구의 주요 내용을 살펴보면 다음과 같다. 공동주택의 난방에너지 소비현상은 단지에 따라 최대 3배이상의 열사용량에 차이가 있는 것으로 나타났다. 열사용량의 차이는 건축의 기본 열성능, 설비시설의 수준 및 노후화정도에 영향을 받으나 동일 연대의 단지들에서도 최대 80$\%$이상의 열사용량이 차이를 보이고 있었으며 이는 기계실 및 각 세대의 난방운전방법 및 제어수준에 따른 것으로 평가되었다. 세대의 층별, 위치별 열사용량 분석에 의하면 층별 열사용량차이가 큰 것으로 분석되었으며, 특히 최상층부와 최하층부의 열사용량이 뚜렷이 많이 나타나 단열성능의 강화가 요구되는 것으로 나타났다. 한편 샘플단지에 대한 측정 데이터를 통해 적정 열량공급시간대의 설정과 외기온의 변화에 따른 적정 온수공급온도의 설정조건 및 유량제어 효과등에 대한 분석 및 검토를 하였으며, 이를 통해 2차년도의 개발목표인 최적운전제어 방안의 제시를 위한 자료를 구축하였다. 또한 각 세대의 기밀성능이 공동주택의 열성능에 미치는 영향을 도출하기 위하여 샘플단지에 대해 트레스가스 측정법과 Blower Door법에 의하여 환기 및 기밀상태를 평가 하였으며 측정주호에 대한 환기를 예측할 수 있는 환기예측평가식을 제시하였다.

  • PDF

An Investigation on the Effect of Duration of Sunshine on the Heating Energy of Apartment Houses (일조시간이 아파트 난방에너지 소비량에 미치는 영향에 관한 조사연구)

  • Lee Jong-Won;Hwang Hye-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.3
    • /
    • pp.277-284
    • /
    • 2005
  • The purpose of this study is to analyze the effect of sunshine on the heating energy consumption of apartment houses by a field investigation in Haeundae, Busan. In the field, heating energy consumption of every household is researched by reading a calorimeter and the duration of sunshine of every household is calculated by Sunlight V1.0. Then, the duration of sunshine and heating energy are done regression analysis by SPSS 10. According to this study the apartment houses by orientation spend more energies order of east, west, southeast, southwest, and south. When apartment houses are same orientation, there is difference of $29{\sim}58\%$ in heating energy consumption by the duration of sunshine. And the heating energy consumption in worst condition of sunshine increases $67\%$ on the best condition of sunshine.

Heating and cooling properties in cultivation room and cultural characteristics of oyster mushroom according to type of air exchange (외부공기 유입방식에 따른 느타리버섯 생육실의 온도변화 및 자실체의 생육특성)

  • Jang, Myoung-Jun;Lee, Yun-Hae;Ju, Young-Cheol
    • Journal of Mushroom
    • /
    • v.11 no.4
    • /
    • pp.214-218
    • /
    • 2013
  • This study was carried out to find out suitable input method for air exchange about bottle cultivation of oyster mushroom. There was no difference of average temperature in cultivation room, but T1(direct introduction of outside air) was higher than T2(heat exchanger) and T3(air buffer) in the standard deviation. The ratio of cooling operating was the highest in August and in the descending order, T1 54%, T3 43%, T2 33%. At ratio of energy reduction, T2 and T3 were higher than T1. The operating ratio of heater was highest in January and in the descending order, T1 53%, T3 37%, T2 30%. At ratio of energy reduction(%), T2 and T3 were higher than T1 similar to result of cooling operating. Therefore there were largest in August about Cooling Degree-Hour and in January about Heating Degree-Hour. And fruitbody yields quality was excellent in T2 and T3 than T1. The suitable effective type of air exchange in oyster mushroom cultivation are heat exchange and air buffer system.

Performance Improvement Technology on a Continuous Heating Heat Pump at Frost Condition (착상조건에서 연속난방이 가능한 히트펌프 성능 향상 기술)

  • Jeon, Chang-Duk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.573-577
    • /
    • 2013
  • Heat pumps come into wide use because high energy efficiency can be obtained and diverse heat sources like geothermal heat, waste heat and air are available. It is necessary for an air source heat pump to defrost in order to remove frost on the surfaces of an outdoor heat exchanger. It is impossible for continuous heating if reverse cycle operation is used as defrosting method, furthermore it causes the degradation of COP. In this study an fin-tube heat exchanger with three rows was used as an outdoor coil. One row among three rows of the heat exchanger was used like a condenser in order to remove frost on it, the others were used as evaporator to accomplish continuous heating. Each row was switched in order from a condenser to an evaporator in specified time interval. Tests were carried out during minimum 180 minutes at the defrost-heating test condition(dry bulb temperature $2^{\circ}C$, wet bulb temperature $1^{\circ}C$) described in KS C 9306. Time-averaged COP was about 20% higher than that of conventional defrosting method.

Accuracy Improvement in Demand Forecast of District Heating by Accounting for Heat Sales Information (열판매 정보를 고려한 지역난방 수요 예측의 정확도 향상)

  • Shin, Yong-Gyun;Yoo, Hoseon
    • Plant Journal
    • /
    • v.15 no.1
    • /
    • pp.31-37
    • /
    • 2019
  • In this study, to improve the accuracy of forecast of heat demand in the district heating system, this study applied heat demand performance among the main factors of district heating demand forecast in Pankyo area as the heat sales information of the user facility instead of existing heat source facility heat supply information, and compared the existing method with the accuracy based on the actual value. As a result of comparing the difference of the forecasts values of the existing and changed methods based on the performance values over the one week (2018.01.08 ~ 01.14) during the hot water peak, the relative error decreased from 7% to 3% The relative error between the existing and revised forecasts was 9% and 4%, respectively, for the five-month cumulative heat demand from February to February 2018, Also, in case of the weekend where the demand of heat is differentiated, the relative error of the forecasts value is consistently reduced from 10% to 5%.

The Optimal Operation Pattern and Heat Pricing Scheme for District Heating CHP System (지역난방용 열병합발전시스템의 최적운전패턴과 적정 열요금구조)

  • 권영한;김창수;진병문;김진오
    • Journal of Energy Engineering
    • /
    • v.5 no.2
    • /
    • pp.183-192
    • /
    • 1996
  • This paper presents a numerical model of the optimal operation pattern of the CHP system built for duel-purpose of power generation and district heat production. The model can be differently formulated in accordance with the view of planner: society, electric utility or district-heating company. Here, the operation pattern of the system components and the effect of heat price are of major interest in the study. From the case study, it was found that the optimal use of auxiliary heating equipment is very important to achieve the minimum societal cost. And, the multi-step heat pricing scheme is desirable to induce the voluntary behavior of both companies towards the societal optimal pattern.

  • PDF

Preparation of Heating Fuel by the Recycling of High Viscosity Waste Oil (고점도 폐유의 재활용에 의한 난방연료 제조)

  • Jin, Eui;Chung, Yeong-Jin
    • Applied Chemistry for Engineering
    • /
    • v.20 no.4
    • /
    • pp.411-415
    • /
    • 2009
  • To replace waste oil with the lowest grade which has high viscosity into heating fuel, light oil and buncker C oil in waste oil was used and the fuel characteristic was analyzed by its concentration after mixing oil. The mixture conditions were controlled by the reaction time (30 s~30 min) and kept by the reaction temperature ($75{\pm}5^{\circ}C$) when mixing speed was stirred at 3400~3600 rpm. We used the buncker C oil and light oil to decrease viscosity of waste oil and the dynamic viscosity was decreased by 81~96%. Optimum mixing ratio (waste oil : buncker C oil : light oil) as heating fuel was 1 : 1 : 1. Flash point, dynamic viscosity and heating value of this case were identified $78^{\circ}C$, $20.02mm^{2}/s$, 9158 kcal/L respectively.