• 제목/요약/키워드: 난방비용 절감

Search Result 50, Processing Time 0.028 seconds

Effect of Heating by Nano-Carbon Fiber Infrared Lamps on Growth and Vase Life of Cut Roses and Heating Cost (나노탄소섬유 적외선등 난방이 절화장미의 생육과 수명 및 난방비에 미치는 영향)

  • Lim, Mi-Young;Ko, Chung-Ho;Son, Moon-Sook;Lee, Sang-Bok;Kim, Gil-Ju;Kim, Byung-Soo;Kim, Young-Bok;Jeong, Byoung-Ryong
    • Journal of Bio-Environment Control
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • The greatest and major cost for cut rose production during winter seasons in Korea is cost of heating the greenhouse. A study was conducted on a cost-efficient heating system to reduce expenses of cut rose growers in times of high energy prices. An infrared heating system utilizing radiant energy has an obvious advantage over other heating methods in that the energy is first used to raise temperatures of plants and other objects and subsequently that of the atmosphere, resulting in faster reaching to desired plant temperatures at a reduced heating cost. In this study the heating effect and heating cost saving of a nano-carbon fiber infrared heating system (NCFIHS) installed in cut rose greenhouses in Gimhae, Gyeongnam Province were analyzed comparatively. In addition growth, quality, and vase life of 'Orange Fresh' roses grown in greenhouses heated by NCFIHS against those grown in greenhouses heated by so called an electrical heating system. In greenhouses with a NCFlHS with a set point air temperature of $20^{\circ}C$, plant temperature was maintained at $1{\sim}2^{\circ}C$ higher than the air temperature, and temperatures of growing bed surface and root zone were maintained at $17{\sim}19^{\circ}C$ throughout cold winter nights. The cost for heating in NCFIHS was about 25 and 51% of that of an electrical heating system and a hot water heating system heated by petroleum, respectively. Growth of roses harvested in greenhouses with a NCFIHS was similar to those grown in greenhouses with an electrical heating system. However, cut roses with more intense petal and leaf colors and a longer vase life (fresh weight and amount of water uptake) were harvested in greenhouses with a NCFIHS as compared to those harvested in greenhouses with an electrical heating system.

Development of Double Distributing Duct Equal to Thermostatic distribution on Hot Air Heater in Protected Cultivation (시설내 온도분포를 균일화 할 수 있는 온풍난방용 2중덕트의 개발)

  • 김태영;김기덕;조일환;남윤일;남은영;우영회;문보흠
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2003.04a
    • /
    • pp.38-43
    • /
    • 2003
  • 우리나라의 시설재배면적은 2001년 현재 52,135ha이고 이중가온 재배면적이 12,710ha로 전체 시설재배면적의 25%에 해당하며 또한 난방비용이 경영비 중 차지하는 비중이 시설재배 선진국의 15%에 비하여 25-30%을 차지하고 있어 난방비의 비중이 높다. 온풍난방시 시설내 에너지 절감을 위한 국내의 연구는 주로 보온, 난방기의 위치 및 Duct의 토출구 간격 및 직경(Kim 등, 1994), 난방배관 구조개선(Kwon 등, 1992)등으로 연구되어 왔다. (중략)

  • PDF

우리아파트 녹색아파트-서울하계동 한신동성아파트

  • Park, Eun-Ju
    • The Magazine for Energy Service Companies
    • /
    • s.47
    • /
    • pp.46-49
    • /
    • 2007
  • 6개동 498세대가 거주하고 있는 서울 하계동 한신동성아파트는 지난 2006년 12월 327kW급 열병합발전기를 도입했다. 기존에 스팀보일러로 중앙난방을 하던 방식에서 발전기로 대체한 이 아파트는 가동한지 7개월만에 2억 원 이상 비용절감을 하고 있다. 한신동성아파트를 찾아가 보았다.

  • PDF

ESCO현장-벽산건설-한국 원자력 연구원의 에스코사업 진행

  • Korean association for escos
    • The Magazine for Energy Service Companies
    • /
    • s.53
    • /
    • pp.28-29
    • /
    • 2008
  • 제2의 자원개발이라는 '에스코'사업은 150불을 넘나드는 고유가로 인해 더욱 높은 관심을 끌고 있다. 특히 1차에너지원의 가격이 높을수록 절약하는 에너지의 양에 비례해 절감액은 더욱 커져 에너지절약의 효과는 더 커진다. 명품 건설 브랜드 '블루밍'으로 유명한 벽산건설에서 지난해 5월부터 금년 4월까지 한국 원자력 연구원의 냉.난방시설 개선 세너지절약 사업을 통해 매년 15억원 상당의 에너지비용을 절감시켰다.

  • PDF

The Study on Smart Farm of Apple Mango with Energy-mix Hybrid (애플망고 농가의 에너지-믹스 하이브리드 스마트 팜에 대한 연구)

  • Son, Jae Hwan;Lee, Seung Yong;Han, Chang Woo;Nah, Kyu Dong;Ha, Yu Shin
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.155-155
    • /
    • 2017
  • 최근 애플망고 스마트 농가에 에너지 사용량이 증가됨에 따라 에너지 절감을 위한 대책들과 화석연료를 대체하는 다양한 신재생에너지 도입에 대한 요구들이 늘고있다. 본 연구에서는 애플망고 스마트 농가에 여러 에너지원들을 혼합하여 사용할 수 있도록 실증시험 모델을 구축하고 운영함으로써 그 효용성을 검토하고자 하였다. 우선 애플망고 특성을 고려한 비닐온실의 최대 냉난방부하량과 에너지모델을 분석하여 신재생 에너지원들의 혼합 및 기존 공조설비와의 연계를 계산하였다. 애플망고 시험 농지로는 재배에 적합한 제주도 서귀포를 선정하였으며, 기존의 경유 난방기를 사용하는 비교시험 하우스, 기존의 경유와 태양광, 지하 공기 히트펌프 난방기를 혼합하여 사용하는 실증시험 하우스, 경유와 지하공기 히트펌프 난방기를 사용하는 대조시험 하우스를 10~11월 두 달간 운영하여 그 결과들을 평가하였다. 온실 내외부에 온도, 습도, CO2를 측정할 수 있는 6점의 센서부들을 설치하였고, 적산 전력계와 유량계를 설치하여 데이터를 수집하였으며, 모든 시험 데이터는 모바일 원격으로 제어 및 모니터링이 가능하도록 구성하였다. 시험 결과, 각 하우스들에서 수확한 과실의 수량과 품질은 유사하게 평가되었지만, 실증시험 하우스의 난방비가 비교시험 하우스보다 절감되었다. 하지만 실증시험 하우스의 경우 높은 시설유지비로 인해 이를 고려한 사용료는 비교시험 하우스보다 더 비싸게 평가되었다. 본 연구를 통해 생산된 잉여전력을 매전할 때 이로 인한 이용비는 비교시험 하우스보다 더 경제적임을 확인할 수 있었다. 또한 기존의 경유와 지하공기 히트펌프 난방기를 혼합한 대조시험 하우스의 난방비용이 경제성에서 더 유리함을 알 수 있었다. 따라서 본 연구를 통해 애플망고 스마트 농가에 적합한 에너지-믹스 모델을 구축할 수 있었으며, 다양한 신재생에너지들의 효용성들을 검토할 수 있었다.

  • PDF

Thermoeconomic Analysis of Hybrid Desiccant Cooling System Driven by District Heating (지역난방에 연계된 하이브리드 제습냉방시스템의 경제성 분석)

  • Ahn, Joon;Kim, Jaeyool;Kang, Byung Ha
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.9
    • /
    • pp.721-729
    • /
    • 2014
  • A hybrid desiccant cooling system (HDCS) that uses a heat pump driven by district heating instead of a sensible rotor can provide an increased energy efficiency in summer. In this paper, the summer operation costs and initial costs of both the HDCS and traditional systems are analyzed using annual equal payments, and national benefits are found from using the HDCS instead of traditional systems. In the analysis results, the HDCS reduces the operation cost by 30 compared to the traditional systems, and each HDCS unit has 0.079 TOE per year of primary energy savings and 0.835 $TCO_2$ per year of $CO_2$ emission reduction more than the traditional systems. If HDCSs were to be installed in 680,000 households by 2020, this would produce a replacement power effect of 463 MW. Despite this savings effect, HDCSs require a government subsidy before they can be supplied because the initial cost is higher than that of traditional systems. Thus, this paper calculates suitable subsidies and suggests a supply method for HDCSs considering the national benefits.

공동주택 최초 지역냉방시스템 현장

  • Park, Jeong-Mi
    • The Magazine for Energy Service Companies
    • /
    • s.42
    • /
    • pp.30-31
    • /
    • 2006
  • 경기도 안산시 사동 푸른마을 3단지 주민들은 남들이 쓰는 에어컨 비용의 3분의 1만 내고도 원하는 시간에 에어컨을 사용하고 쾌적함까지 맛보고 있다. 바로 지역냉장시스템 덕분이다. 이 시스템은 공동주택으로서는 전국 최초로 시범설치된 것으로 하절기 소각열 등 버려지는 열을 이용해 에너지비용을 절감하면서도 프레온가스를 사용하지 않아 친환경적이다. 이 사업은 지난 2001년부터 안산지역에 지역난방을 공급하고 있는 안산도시개발(주)이 시행되고 있다.

  • PDF

Optimization of Integrated District Heating System (IDHS) Based on the Forecasting Model for System Marginal Prices (SMP) (계통한계가격 예측모델에 근거한 통합 지역난방 시스템의 최적화)

  • Lee, Ki-Jun;Kim, Lae-Hyun;Yeo, Yeong-Koo
    • Korean Chemical Engineering Research
    • /
    • v.50 no.3
    • /
    • pp.479-491
    • /
    • 2012
  • In this paper we performed evaluation of the economics of a district heating system (DHS) consisting of energy suppliers and consumers, heat generation and storage facilities and power transmission lines in the capital region, as well as identification of optimal operating conditions. The optimization problem is formulated as a mixed integer linear programming (MILP) problem where the objective is to minimize the overall operating cost of DHS while satisfying heat demand during 1 week and operating limits on DHS facilities. This paper also propose a new forecasting model of the system marginal price (SMP) using past data on power supply and demand as well as past cost data. In the optimization, both the forecasted SMP and actual SMP are used and the results are analyzed. The salient feature of the proposed approach is that it exhibits excellent predicting performance to give improved energy efficiency in the integrated DHS.

Effects of Minimizing the Heating Space on Energy Saving and Hot Pepper(Capsicum annuum L.) Growth in the Plastic Greenhouse (온실 난방공간 최소화가 에너지 절감 및 고추 생육에 미치는 영향)

  • Tae Young Kim;Young Hoe Woo;Ill Hwan Cho;Young Sam Kwon;Si Young Lee;Han Ik Jang
    • Journal of Bio-Environment Control
    • /
    • v.10 no.4
    • /
    • pp.213-218
    • /
    • 2001
  • In 2000, domestic protected cultivation area was about 52,189 ha including 13,621 ha of heating greenhouses. Recently, heating cost accounts for 25 to 30% of total production cost which has been increased due to the rise of oil price, while the heating cost was about 15% in other advanced countries. To reduce the heating energy cost, the study of minimizing the heating space of greenhouse have been conducted from 1998 to 1999. The system was developed to control the heating space according to crop growth by moving horizontal curtain up and down. Installation of the heating space-control curtain in greenhouse decreased heating capacity to 264 m$^3$compared to 661.5 m$^3$in the traditional curtain, and consumpted fuel was saved about 56% point in semiforcing culture and 28% point in retarding culture of pepper. In addition, uniform distribution of air temperature and relative humidity in greenhouse environment resulted in earlier flowering and higher yields in hot pepper.

  • PDF

Comparison of Heating Characteristics of Electric Heating Element Heater and Oil Hot Air Heater in Single Span Greenhouses (전기발열체 난방기 및 유류온풍 난방기의 단동온실 난방 특성 비교)

  • Kwon, Jin Kyung;Kim, Seung Hee;Shin, Young An;Lee, Jae Han;Park, Kyeong Sub;Kang, Youn Koo
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.324-332
    • /
    • 2017
  • The comparative experiments were conducted for single span greenhouses where cucumbers were cultivated to analyze the effect of heating between a carbon fiber electric heating element heater and an oil hot air heater in terms of the inside climate, energy consumption and plant growth. In order to analyze the effect of heating capacity, 6, 9, and 16 kW of electric powers were supplied to the electric heating element for same setting temperature of 15?. As a result, as the heating capacity increased, the number of ON-OFF cycles of the electric heating element and the temperature inside the greenhouse increased proportionally. In the comparison of two heaters, it was shown that the temperature and relative humidity distributions of the electric heating element installed greenhouse was much uniform than those of the oil hot air heater installed greenhouse. The heating energy consumptions during the heating period of 79 days were 867L for the oil hot air heater and 8,959 kWh for the electric heating element heater, and the heating costs were 607 and 403 thousand won respectively. In the electric heating element installed greenhouse, the cucumber growth was slightly better and the yield was 4.3% higher than those of the oil hot air heater installed greenhouse, but there were no statically significant difference in the cucumber growth and yield between greenhouses.