• Title/Summary/Keyword: 나사 유지형

Search Result 33, Processing Time 0.022 seconds

The Effects of Screw Retained Prosthesis Misfit & Cantilever on Stress Distribution in Bone Around the Implant (나사유지형 임플란트 고정성 보철물의 적합도와 캔틸레버가 지지골조직의 응력분산에 미치는 영향)

  • Lee, Jae-In;Kim, Tae-Young;Cho, Hye-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.224-235
    • /
    • 2013
  • A passively fitting prosthesis is an essential prerequisite to attain long-lasting success and maintenance of osseointegration. However, true "passive fit" can not be achieved with the present implant-supported prosthesis fabrication protocol. Many clinical situations are suitably treated with cantilevered implant-supported fixed restorations. The purpose of this study was to compare the stress distribution pattern and magnitude in supporting tissues around ITI implants with cantilevered, implant-supported, screw-retained fixed prosthesis according to the fitness of superstructures. Photoelastic model was made with PL-2 resin (Measurements, Raleigh, USA) and three ITI implants (${\phi}4.1{\times}10mm$) were placed in the mandibular posterior edentulous area distal to the canine. Anterior and posterior extended 4-unit cantilevered FPDs were made with different misfit in the superstructures. 4 types of prosthesis were made by placing a $100{\mu}m$ gap between the abutment and the crown on the second premolar and/or the first molar. Photoelastic stress analysis were carried out to measure the fringe order around the implant supporting structure under simulated loading conditions (30 lb).

원지점 차넣기 모타 적용 잠입노즐 기초 기술 개발

  • 노태호;황종선;조인현
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.32-32
    • /
    • 2000
  • 잠입노즐은 로케트 추진기관의 길이 및 중량을 감소시켜 체계설계의 관점에서 볼 때 많은 이점을 제공한다. 본 연구에서는 3단형 과학로케트 원지점 차넣기 모타(apogee kick motor)에 적용하기위한 잠입노즐의 기초기술 개발에 주안점을 두었다. 고고도에서 저속으로 회전하며 비행하는 원지점 차넣기 모타를 제작하기위해서 체계 요구성능에 의해 예상된 실물형의 50% 크기에 해당하는 축소형 잠입노즐을 제작하였다. 잠입노즐은 잠입부의 내외부가 고온의 추진제 연소가스에 노출된 상태에서 노즐 내부 압력 외에 연소실압에 의한 외부압력이 작용하므로 이를 고려한 열 및 구조설계가 중요하다. 본 연구에서는 노즐 수렴부와 목부에 일체형 그라파이트 소재를 적용하고 확장부 내열재 및 잠입부 배면내열재에 탄소/페놀 복합재를 노즐 내열재로 사용하였다. 그리고 이들의 구조적 지지를 위해 스틸구조물을 적용하였다. 적용된 스틸구조물에는 K형 열전쌍을 이용해 내열재와 구조물 온도를 측정할 수 있는 관통구멍 및 나사부를 구조물 외변에 가공하였다. 열전쌍은 노즐 목직경의 2, 4배 되는 확장부 내열재 단면위치의 2mm와 4mm 깊이와 구조물 내면 및 외면의 4개소에 열전쌍을 부착하여 지상연소시험시 노즐 내열재와 구조물의 온도분포를 관찰한다. 그리고 노즐 조립시 확장부 내열재와 구조물에 각 각 반원형 홈을 내어 여분의 접착제가 원형 홈에 밀려들어가 경화되어 노즐 기밀유지와 체결력을 향상시킬 수 있는 원형공간 접착제 충전 공법을 적용하여 실제모타에 대한 적용가능성을 지상연소시험을 통해 확인한다.

  • PDF

A Development of Seismic Rehabilitation Method of RC Buildings Strengthened with X-Bracing Using Carbon Fiber Composite Cable (X-가새형 탄소섬유케이블을 이용한 중·저층 철근콘크리트 건물의 내진보강법 개발)

  • Lee, Kang-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.1-9
    • /
    • 2014
  • Improving the earthquake resistance of buildings through seismic retrofitting using steel braces can result in brittle failure at the connection between the brace and the building, as well as buckling failure of the braces. In this study, a non-compression cross-bracing system using the Carbon Fiber Composite Cable (CFCC), which consists of CFCC bracing and bolt connection was proposed to replace the conventional steel bracing. This paper presented the seismic resistance of a reinforced concrete frame strengthened using CFCC X-bracing. Cyclic loading tests were carried out, and the maximum load carrying capacity and ductility were investigated, together with hysteresis of the lateral load-drift relations. Test results revealed that the CFCC X-bracing system installed RC frames enhanced markedly the strength capacity and no buckling failure of the bracing was observed.

A COMPARISON OF LOAD TRANSFER IN SCREW- AND CEMENT-RETAINED IMPLANT FIXED PARTIAL DENTURE DESIGNS (임플랜트 상부 보철물의 고정 방식에 따른 힘의 분포에 관한 연구 : 나사 유지형 대 시멘트 유지형)

  • Lee Joo-Hee;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.2
    • /
    • pp.125-145
    • /
    • 2001
  • To compare the stress distribution patterns between cement-retained and screw-retained implant supported fixed prostheses according to four different abutment types, a three dimensional finite element analysis was performed. The hypothetical three unit fixed partial denture case was modelled on the three implants(10mm length and 3.75 diameter) in mandibular bone. Four angles of implantation(vertical, 10, 15 and 20 degree inclined mesially) were created and three different directions of force (vertical, oblique, horizontal) were applied at the center of the second premolar and distal end of the first molar for each cases. Within the limits of this study, the results were as follows, 1. In vertically installed cases, the more stress was concentrated at upper components, but mesially inclined cases, the more stress was concentrated at cortical bone. 2, The more inclined mesially the more stress was observed, especially at cortical bone. 3. The cement-retained models showed lower principal stress and more even stress distribution than the screw-retained models. 4. The similar stress distribution pattern was showed in model 1 and model 2, model 3 and model 4. 5. The more stress was observed when the loads were applied at the distal end of 1st molar than the center of 2nd premolar. 6 The fixture and the model as a whole, lesser stress values were observed when vertical loads were applied as compared to horizontal and oblique loads.

  • PDF

Stress distribution of implants with external and internal connection design: a 3-D finite element analysis (내측 연결 및 외측 연결 방식으로 설계된 임플란트의 3차원적 유한요소 응력 분석)

  • Chung, Hyunju;Yang, Sung-Pyo;Park, Jae-Ho;Park, Chan;Shin, Jin-Ho;Yang, Hongso
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.3
    • /
    • pp.189-198
    • /
    • 2017
  • Purpose: This study aims to analyze the stress distribution of mandibular molar restoration supported by the implants with external hex and internal taper abutment connection design. Materials and Methods: Models of external connection (EXHEX) and internal connection (INCON) implants, corresponding abutment/crowns, and screws were developed. Supporting edentulous mandibular bony structures were designed. All the components were assembled and a finite element analysis was performed to predict the magnitude and pattern of stresses generated by occlusal loading. A total of 120 N static force was applied both by axial (L1) and oblique (L2) direction. Results: Peak von Mises stresses produced in the implants by L2 load produced 6 - 15 times greater than those by L1 load. The INCON model showed 2.2 times greater total amount of crown cusp deflection than the EXHEX model. Fastening screw in EXHEX model and upside margin of implant fixture in INCON model generated the peak von Mises stresses by oblique occlusal force. EXHEX model and INCON model showed the similar opening gap between abutment and fixture, but intimate sealing inside the contact interface was maintained in INCON model. Conclusion: Oblique force produced grater magnitudes of deflection and stress than those by axial force. The maximum stress area at the implant was different between the INCON and EXHEX models.

Patent Technologies for Reducing Micro-Dust (미세먼지 저감을 위한 특허기술들)

  • Cho, Taejun;Kim, Tae-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.9-14
    • /
    • 2020
  • Four developed patents have applied for a new type of Composite Cyclone Scrubber followed by the previous research (Cho and Kim, 2017), including dust reducing fan with filters. Regarding target installation and maintenance cost, 64% reduction for investment costs (6.2 billion won vs. 17 billion won) compared to existing road pollution reduction system, while social benefit costs increase by 43% compared to existing road pollution reduction measures (72.6 billion won vs. 50.8 billion won). The composition of the device is an air blower type spiral guide vane, and an injection pressure collecting dust efficiency. A nozzle varies Injection angle and contact range, spray liquid species (waterworks, salty water). The proposed patent tests are circulation water Time-by-Time Spray and collected 41.4% more increased micro dust since the sprayed water meets contaminated gas due to the 45° degree colliding, which is 141% increased conventional dust collector. (Ratio of collection over 85%). As regards the source of collection liquid, circulated rainwater and well water, we expect a huge amount of energy and economically saved eco-friendly system in our patent. Finally, the guided vane and metal filter reduced over 90% micro-dust, while sprayed water cleans the vane and filters, resultantly minimizing the maintenance budget. The preliminary evaluations of the developed design make it possible to reduce not only cheaper maintenance budget due to the characteristic water spraying but the cost of water comes from mainly rain and underground.

Influence of Implant Fixture-Abutment Connection and Abutment Design on Mechanical Strength (임플란트 고정체-지대주 연결부 및 지대주 디자인이 기계적 강도에 미치는 영향)

  • Chun, Mi-Hyun;Jeong, Chang-Mo;Jeon, Young-Chan;Eom, Tae-Gwan;Yoon, Ji-Hoon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.269-281
    • /
    • 2008
  • Fatigue or overload can result in mechanical problems of implant components. The mechanical strength in the implant system is dependent on several factors, such as screw and fixture diameters, material, and design of the fixture-abutment connection and abutment. In these factors, the last rules the strength and stability of the fixture-abutment assembly. There have been some previous reports on the mechanical strength of the fixture-abutment assembly with the compressive bending test or short-term cyclic loading test. However, it is restrictive to predict the long-term stability of the implant system with them. The purpose of this study was to evaluate the influence of the design of the fixture-abutment connection and abutment on the mechanical strength and failure mode by conducting the endurance limit test as well as the compressive bending strength test. Tests were performed according to a specified test(ISO/FDIS 14801) in 4 fixture-abutment assemblies of the Osstem implant system: an external butt joint with Cemented abutment (group BJT), an external butt joint with Safe abutment (group BJS), an internal conical joint with Solid abutment (group CJO), and an internal conical joint with ComOcta abutment (group CJT). The following conclusions were drawn within the limitation of this study. Compressive bending strengths were decreased in order of group BJS(1392.0N), group CJO(1261.8N), group BJT(1153.2N), and group CJT(1110.2N). There were no significant differences in compressive bending strengths between group BJT and group CJT(P>.05). Endurance limits were decreased in order of group CJO(600N), group CJT(453N), group BJS(360N), and group BJT(300N). 3. Compressive bending strengths were influenced by the connection and abutment design of the implant system, however endurance limits were affected more considerably by the connection design.

Cases of screw-retained implant prosthesis in the anterior maxilla through multidisciplinary approach, including orthodontic teeth alignment (교정적 치아 재배열을 포함한 다학제적 접근(multidisciplinary approach)을 통한 상악 전치부의 나사 유지형 임플란트 보철 수복 증례)

  • Kim, Hyo-Seon;Lee, Won-Sup;Lee, Su-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.244-250
    • /
    • 2020
  • The labio-palatal location of the implant in the maxillary anterior region is one of the important factors affecting the aesthetics of the implant prosthesis. However, the thin labial bone of maxilla could be absorbed in significant amounts after extraction of the teeth, which makes the implant be placed on the palatal side rather than the ideal location. In fact, in the cases of maxillary central incisor loss, UCLA was used for prosthetic restoration of palatally placed implant. In addition, with multidisciplinary treatment, GBR (Guided Bone Regeneration) was performed for compensating the absorbed alveolar bone and adjacent anterior tooth were aligned. Definitive restoration was performed after confirming aesthetic recovery of the gingiva with sufficient provisional restoration period. There were satisfactory results of functional and esthetic recovery of tooth loss through implant prosthesis.

Effect of internal gap on retentivity in implant fixed prosthesis with lingual slot (설측 슬롯을 부여한 임플란트 고정성 보철물에서 내면 간격이 유지력에 미치는 영향)

  • Kim, Tae-Kyun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.206-211
    • /
    • 2018
  • Purpose: Recently, a method of forming a slot in the prosthesis lingual has been introduced to solve the occlusal and aesthetic disadvantages of screw-retained prosthesis in the manufacture of implant-fixed prosthesis and to ensure retrievability in cement retained prostheses. The purpose of this study is to investigate the effect of the internal gap on the removal of the prosthesis in the preparation of cement-retained implant prostheses with lingual slots. Materials and methods: Titanium abutment and internal gap of the zirconia prosthesis to be attached to the upper part were set to 30, 35, and $50{\mu}m$, respectively. Three for each type total 15 were produced for each type. The zirconia prosthesis formed a retrievable cement-type slot with a space of 1 mm at the location where the titanium abutment meets the shelf area. Autocatalytic resin cement was used for bonding of abutment and zirconia prosthesis, and the maximum removal stress value was measured in units of Ncm by using the customized equipment of the cemented specimen. The Kruskal-Wallis test was used to compare the three groups by statistical analysis (${\alpha}=.05$), modified by post hoc test the Mann-Whitney U-test and the Bonferroni correction method were used to compare the two methods (${\alpha}=.017$). Results: There was no statistically significant difference in removal stress between the $30{\mu}m$ group and the $35{\mu}m$ group in the internal gap (P = .032), and there was a significant difference between the $30{\mu}m$ group and the $50{\mu}m$ group, between the $35{\mu}m$ group and the $50{\mu}m$ group (P < .017). Conclusion: Thus, the internal gap of computer-aided design affected the retention between the zirconia prosthesis and the titanium abutment.

All-on-6 implant fixed prosthesis restoration with full-digital system on edentulous patient: A case report (무치악 환자에서 완전 디지털 시스템을 활용한 All-on-6 임플란트 고정성 보철물 수복 증례)

  • Lee, SeungJin;Jeong, Seung-Mi;Chung, Chae-Heon;Fang, YiQin;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.497-507
    • /
    • 2021
  • All-on-six concept can be used as one of the treatment options to maximize the use of available residual alveolar bone for implant-supported fixed prosthesis on edentulous patients. But this process is complex and cumbersome. Digital system can be used at multiple steps, from implantation to prosthetic restoration, to overcome this shortcoming. In this case of a maxillary edentulous patient aged 76, digital system was used for restoration of 1-piece design, screw retained fixed prosthesis from diagnosis, implant surgery to fabrication of provisional and final prosthesis. For preoperative diagnosis and treatment planning stage, intra-oral information of a patient was digitalized by direct intra-oral scan. Surgical guide and immediate provisional prosthesis was designed based on this digitalized data. Patient's inconvenience was minimized by applying immediate provisional prosthesis, which was delicately fabricated according to the location data of six implants on most suitable residual alveolar bone. Then, final prosthesis was designed and fabricated going through new interim prosthesis which was newly designed and fabricated, considering patient's requests, stable vertical dimension and occlusion, and esthetic factors using digital system. We hereby report a case successfully applying digital system to multiple steps including implant surgery to fabricating prosthesis, to simplify existing complicated implant treatment procedure to an edentulous patient.