• Title/Summary/Keyword: 나사제거

Search Result 49, Processing Time 0.031 seconds

Effect of dual pitch mini-implant design and diameter of an orthodontic mini-implant on the insertion and removal torque (교정용 미니임플랜트의 이중 피치와 직경의 차이가 삽입 및 제거 토크에 미치는 영향 평가)

  • Kim, Jong-Wan;Cho, Il-Sik;Lee, Shin-Jae;Kim, Tae-Woo;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.36 no.4
    • /
    • pp.275-283
    • /
    • 2006
  • Objective: Small orthodontic mini-implants are useful as anchorage. However they have some weaknesses such as loosening. This study was carried out to analyze the mechanical effects of the dual pitch and diameter on the insertion and removal torque of mini-implants. Methods: The threads of mini-implants were mono and dual pitch. The diameters of mini-implants were 1.4 mm and 1.6 mm. Four groups were tested (mono 1.4 mm, mono 1.6 mm, dual 1.4 mm and dual 1.6 mm). All were inserted and removed on polyurethane foam with the torques being measured. Results: The maximum torque of the dual pitch groups was higher than the mono pitch groups during removal but lower during insertion. The maximum torque of the 1.6 mm diameter groups was higher than the 1.4 mm diameter groups during insertion and removal. The dual pitch 1.4 mm group showed the lowest insertion torque but had similar or superior levels of removal torque to that of the mono pitch 1.6 mm group. Conclusions: The dual pitch especially showed a continuous high removal torque after the peak. Despite the small diameter, the dual pitch might improve the initial mechanical stability.

Mechanical analysis of the taper shape and length of orthodontic mini-implant for initial stability (교정용 미니임플랜트의 초기 안정성에 대한 원추형태와 길이에 관한 기계역학적 분석)

  • Kim, Jong-Wan;Cho, Il-Sik;Lee, Shin-Jae;Kim, Tae-Woo;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.36 no.1 s.114
    • /
    • pp.55-62
    • /
    • 2006
  • Orthodontic mini-implants, despite its usefulness as anchorage, have some limits such as loosening. Therefore, various shapes and lengths have been studied. The aim of this study is to analyze the shape and length of mini-implants mechanically. The shapes of mini-implants (1.6 mm, Dual Top, Jeil Medical Co., Seoul, Korea) were cylindrical and taper. The lengths of mini-implants were 6 mm and 8 mm. The tested groups were 5 groups (cylindrical 6 mm, cylindrical 8 mm, taper 6 mm, taper 8 mm and taper 8 mm modified whose thread is reduced from the middle to upper part). All were inserted and removed on the polyurethane foam with the torque measured. During insertion and removal, the taper shape needed higher torque than the cylindrical shape, and the 8 mm length than the 6 mm length (p<0.001). The taper 6mm group showed superior insertion torque (p<0.001) and similar removal torque to the cylindrical 8 mm group. The taper 8 mm modified group with gradually reduced threads, showed continuous high removal torque after the peak. The initial mechanical stability can be provided by the tapered shape and also, affected by length and thread design.

Finite element analysis of cortical bone strain induced by self-drilling placement of orthodontic microimplant (Self-drilling 방식의 마이크로임플란트 식립에 의해 발생하는 피질골 스트레인의 유한요소해석)

  • Park, Jin-Seo;Yu, Won-Jae;Kyung, Hee-Moon;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.39 no.4
    • /
    • pp.203-212
    • /
    • 2009
  • Objective: The aim of this study was to evaluate the strain induced in the cortical bone surrounding an orthodontic microimplant during insertion in a self-drilling manner. Methods: A 3D finite element method was used to simulate the insertion of a microimplant (AbsoAnchor SH1312-7, Dentos Co., Daegu, Korea) into 1 mm thick cortical bone. The shape and dimension of thread groove in the center of the cortical bone produced by the cutting flute at the apical of the microimplant was obtained from animal test using rabbit tibias. A total of 3,600 analysis steps was used to calculate the 10 turns and 5 mm advancement of the microimplant. A series of remesh in the cortical bone was allowed to accommodate the change in the geometry accompanied by the implant insertion. Results: Bone strains of well higher than 4,000 microstrain, the reported upper limit for normal bone remodeling, were observed in the peri-implant bone along the whole length of the microimplant. Level of strains in the vicinity of either the screw tip or the valley part were similar. Conclusions: Bone strains from a microimplant insertion in a self-drilling manner might have a negative impact on the physiological remodeling of cortical bone.

Implant-assisted removable partial denture using freely removable abutment in a fully edentulous patient: A case report (완전 무치악 환자에서 자유 착탈가능 임플란트 지대주를 이용한 임플란트 융합 국소의치 수복증례)

  • Oh, You-Kyoung;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Lee, Hyeon-Jong;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.58-66
    • /
    • 2020
  • Implant-Assisted Removable Partial Dentures (IARPDs) treatment is being performed in a fully edentulous patient using implant surveyed prosthesis as an abutment. Implant-supported prosthesis as an abutment of IARPDs is classified into screw-retained and cement-retained type according to the retention type, and each has advantages and disadvantages. The EZ crown system (Samwon DMP, Yangsan, Korea) has a cylinder combined with abutment, and the nickel-titanium spring in this cylinder provides a constant force on the zirconia ball to obtain retention in EZ crown system. In this patient, the natural abutment teeth of the mandibular overdenture was hopeless. We planned implant assisted removable partial denture using anterior implant surveyed prosthesis considering functional and esthetical rehabilitation, cost and patient's needs. When fabricating IARPDs using implant as abutment, we could compensate for the shortcomings of existing implant-supported prosthesis retention type and made the design of removable partial denture easy due to using EZ crown system.

Arthscopic Treatment of Osteochondritis Dissecans in Femoral Condyle (관절경을 이용한 대퇴골과 박리성 골연골염에 대한 치료)

  • Kim Sung-Jung;Kyung Hee-Soo;Ihn Joo-Chul;Lee Seong-Man
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.2
    • /
    • pp.138-143
    • /
    • 2000
  • Purpose : We analyzed clinical and radiological results of the treatment of osteochondritis dissecans in the femoral condyle under arthroscopic guidance. Materials and Methods : The study group consists 19 cases in 17 patients. Average follow up period was 34 months and average age was 16 years. The cases were classified by 4 different groups, using the fellowing system: Group 1-stable lesion and no specific treatment after arthroscopic examination; Group 2-early separation and multiple drilling; Croup 3-unstable lesion and Herbert screw fixation; Croup 4-loose body removal and/or crater curettage. The results were analyzed by the criteria of Hughston which including clinical and radiologic outcomes. Results : There were 14 cases$(74\%)$ of good and excellent results in 19 knees in which, $75\%$(3/4) in Group 1, $75\%$(3/4) in Group 2, $86\%$(7/8) in Group 3 and $33\%$(1/3) in Group 4. The result of Herbert screw fixation group was better than that of other groups with statistically significant differences. Conclusion : In the treatment of osteochondritis dissecans of skekletally immature patients, arthroscopic finding was reliable guidance in decision of treatment method and active fixation was recommended in patients with large, unstable lesion.

  • PDF

Effects of Pretreatment of Alkali-degreasing Solution for Cu Seed Layer (약알칼리탈지 용액에서의 구리 Seed 층의 전처리 효과)

  • Lee, Youn-Seoung;Kim, Sung-Soo;Rha, Sa-Kyun
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.1
    • /
    • pp.6-11
    • /
    • 2012
  • In order to understand a process of contaminants removal on surface of Cu seed layer (Cu seed/Ti/Si) by sputter deposition, we investigated the changed morphology and states of Cu seed surface after pretreatment in alkali degreasing Metex TS-40A solution according to dipping time. After TS-40A pretreatment, the surface morphology with clearer grains was observed by Field emission scanning electron microscope and the changed surface chemical states and impurities on surface of samples were checked by X-ray photoelectron spectroscopy. Dipping time in TS-40A solution had very little effect on surface of Cu seed layer. After pretreatment, much carbons and little oxygens on surface of Cu seed were eliminated and the decrease of peaks corresponded to O=C and $Cu(OH)_2$ was estimated. However, Si content (=silicate) was detected on sample surface. We think that the silicate impurity forms on Cu seed by chemical reaction of TS-40A solution included silicate component. By pretreatment of alkali degreasing Metex TS-40A solution, it showed an excellent effect in removal of O=C and $Cu(OH)_2$ on Cu seed layer, but the silicate was formed on surface of Cu seed. Therefore, another cleaning process such as acid cleaning is required for removal of this silicate in use of this alkali degreasing.

FIXATION OF FRACTURED ORBITAL BONE USING AUTOGENOUS CALVARIAL BONE PLATE (자가 두개골 플레이트(autogenous calvarial bone plate)를 이용한 골절된 안와골의 고정)

  • Yang, Yun-Seok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.19 no.4
    • /
    • pp.377-382
    • /
    • 1997
  • Miniplate의 사용은 Champy등의 보고 이후 구강외과 영역에 있어서 외상 혹은 악교정수술등 많은 분야에 이용되기 시작했다. 전통적인 악간고정 방법에 비해 miniplate는 사용하기 쉽고, 정확한 해부학적 정복 및 고정을 가능케 하며 결과적으로 빠른 치유를 가능케 한다는 장점들을 갖고 있다. 그러나 감염, wound dehiscence, 부식, 나사의 헐거워짐, 주위조직의 변색 그리고 stress shielding effect등의 후유증들이 보고되어 왔으며 가장 무해한 금속이라고 알려진 titanium 또한 주위조직 및 lung, spleen, liver 그리고 kidney 등과 같은 조직으로 metal을 전이시키는 것으로 보고되고 있다. 특히 안와골 주변과 같은 상부 연조직이 얇은 곳에 miniplate를 사용할 경우 miniplate가 만져지거나 보일수도 있다는 점이 보고되었으며 따라서 술후 사용되었던 miniplate를 제거 해야만 할 것인가가 또한 주된 관심사로 보고되고 있다. 이에 저자는 이러한 금속성 miniplate의 단점을 개선하고자 자가 두개골을 이용한 플레이트를 고안하였다. '자가 두개골 플레이트'의 적응증은, enophthalmos 개선의 목적으로 두개골을 채취해 임플란트로 사용하는, enophthalmos를 동반한 관골 및 안와골의 복합골절환자에 있어 두개골의 추가채취가 가능한 경우가 될 수 있겠다. 자가 두개골을 이용해 플레이트를 고안하려고 본 증례에서의 시도는 구강외과 영역에 있어서 자가 두개골이 골편이 고정재료로도 쓰일 수 있다는 가능성을 보여주었다는 점에서 의미가 있다고 저자는 생각한다.

  • PDF

Study of Cutting Characteristics in High Speed Synchronized Tapping (고속 동기 탭핑에서의 절삭 특성에 관한 연구)

  • 정용수;이돈진;김선호;안중환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.304-307
    • /
    • 2002
  • High speed machining was accomplished. through the technological advances which covers the whole field of mechanical industry. But tapping have many troubles because of its complicate cutting mechanism, for example. tool damage, chip elimination and synchronization between spindle rotation and feed motion. But High speed tapping is so important that it marches in step with the flow of the times and make improvement in the productivity. In this paper we analyze mechanism of high speed synchronized tapping with the signal of tapping torque and spindle speed obtained through the newly developed high speed tapping machine(NTT-30B). We made an experiment with this machine on condition of various speed from 1000rpm to 10000rpm. As one complete thread is performed through the whole chamfer cutting, cutting torque increases highly in chamfer cutting, but smoothly in full thread cutting functioning of the threads guide. And the size of cutting torque according to spindle speed(rpm) was not enough of a difference to be conspicuous.

  • PDF

A Radial Nerve Palsy Cases Managed by Yinyang Balance Appliance of FCST, a TMJ Therapy for the Balance of Meridian and Neurological System (FCST 음양균형장치를 활용한 요골신경마비치료의 증례보고)

  • Kim, Young Pan;Lee, Sang Bae
    • Journal of TMJ Balancing Medicine
    • /
    • v.5 no.1
    • /
    • pp.13-15
    • /
    • 2015
  • Therapeutic effect of Yinyang Balancing Appliance of functional cerebrospinal therapy (FCST) for meridian and neurologic yinyang balance was observed in a radial nerve palsy case. One Radial nerve palsy case was managed with the Yinyang Balancing Appliance on temporomandibular joint (TMJ), combined with acupuncture. Clinical outcome measurement was based on subjective measures and clinical observations. The patient showed positive changes even after the initial treatment and this effect maintained over the follow-up period. further clinical and biological research on FCST is expected.

  • PDF

Design and Construction of the Sprout Trimmer for a 3-Wheel Riding Type Cultivating Vehicle (3륜 승용관리기용 순 지르기 작업기 설계 제작)

  • Choi, Il Soo;Choi, Yong;Lee, Beom Seob;Ji, Keum Bae;Yun, Young Tae;Yoo, Soo Nam
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.75-75
    • /
    • 2017
  • 3륜 승용관리기는 4륜 승용관리기에 비하여 작업기를 복부에 장착함으로 작업의 정밀도, 편이성, 관측의 용이성 향상과 함께 지상고 제고, 차폭 조절, 조향 등의 성능 개선을 기할 수 있다. 국내에서는 3륜 승용관리기용 복부 장착 부속작업기가 거의 개발되어 있지 않으며, 특히 두류 재배에 있어서 일관기계화 작업을 위한 관리작업기의 개발이 매우 필요한 실정이다. 콩의 순 지르기 작업은 콩이 지나친 생육을 한 경우 미리 줄기의 윗부분을 제거하는 저심처리를 해주면 곁가지들의 왕성한 생육을 유도하여 많은 꼬투리를 얻고 쓰러짐도 줄어들어 수량을 높일 수 있다. 순 지르기 작업은 보통 낫이나 배부식 예취기를 이용하여 작업함으로 노동력이 많이 들고 작업부담이 심하여 개선이 필요한 실정이다. 따라서 본 연구는 3륜 승용관리기에 적합한 복부장착형의 순 지르기 작업기를 설계 제작하였다. 3륜 승용관리기용 순 지르기 작업기는 승용관리기의 복부 PTO에서의 구동력 전달을 위한 연결 조인트, 중간축, 기어 전동기구, 구동축으로 구성된 동력전달부, 2 조의 원판형 작업 날, 다양한 조간거리에 적응을 위한 조간조정 나사부, 3륜 승용관리기에의 부착을 위한 프레임 및 부착보조 작업기 이동용 바퀴장치 등으로 구성 설계 제작하였다. 원판형 칼날은 시판 중인 예취기의 외경 305 mm, 칼날 톱니 수 90개의 초경 비트 부착 날을 사용하였다. 작업 날의 승강높이는 150~540 mm 범위로 조절하도록 하였다. 조간거리의 조절범위는 수동나사에 의하여 660~860 mm 범위로 무단조절 할 수 있도록 하였다. 순 지르기 작업기는 3륜 승용 관리기 복부의 평행링크에 부착되므로 작업기의 이동 및 부착 편이를 위하여 이동용 바퀴를 설치하였다. 제작된 순 지르기 작업기의 크기는 길이${\times}$${\times}$높이가 $514{\times}1138{\times}810mm$, 중량은 약 100 kg으로 제작되었다.

  • PDF