• 제목/요약/키워드: 나노버블

검색결과 21건 처리시간 0.026초

아질산칼슘과 탄산나노버블수를 사용한 모르타르의 성능 평가 (The Performance Evaluation of Mortar Using Calcium Nitrite and CO2 Nano-Bubble Water)

  • 김호진;김진성;최형길
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.145-146
    • /
    • 2020
  • This study investigated the performance evaluation of polymer cement mortar for repairing concrete structures using calcium nitrite(Ca(NO2)2) and CO2 nano-bubble mixing water to develop section-restoration methods for the repair and reinforcement of cracks. The evaluation items were strength and microstructure analysis at 28 days of age according to the change in the amount of calcium nitrite and the use of CO2 nano-bubble water. As a result of the experiment, it was confirmed that the performance of polymer cement mortar for repairing concrete structures was improved by the generation of nitrite-based hydration products when calcium nitrite and CO2 nano-bubble water were used.

  • PDF

탄소나노튜브 및 마이크로 글래스 버블 기반 열전 복합재 (Thermoelectric Composites Based on Carbon Nanotubes and Micro Glass Bubbles)

  • 강구혁;성광원;김명수;김인국;방인철;박형욱;박영빈
    • Composites Research
    • /
    • 제28권2호
    • /
    • pp.70-74
    • /
    • 2015
  • 본 논문에서는 탄소나노튜브(CNT)와 마이크로 글래스 버블(GB)을 포함한 폴리아마이드 6(PA6) 복합재의 열전 특성을 다뤘다. 복합재에 포함된 GB은 복합재 내에서 큰 공간을 차지하게 되는데, 이때 CNT는 GB가 없는 공간으로 밀려나면서 고밀도로 격리된(segregated) 네트워크를 형성한다. CNT의 분산을 위해, 소니케이션(Sonicatoin)으로 CNT를 분산시킨 PA6, 포름산 용액을 증류수를 이용하여 응고시킨 후 압축성형하여 복합재 판을 제조하였다. 복합재 판의 열전성능을 평가하기 위해서 열전도도, 전기전도도, 제벡계수(Seebeck coefficient) 등을 측정하였고, 최고 0.016의 성능지수를 얻었다.

산화 이리듐의 물의 산화반응에 대한 버블 과전압 현상과 촉매 특성 연구 (Study on Electrocatalytic Water Oxidation Reaction by Iridium Oxide and Its Bubble Overpotential Effect)

  • 김정중;최용수;권성중
    • 전기화학회지
    • /
    • 제16권2호
    • /
    • pp.70-73
    • /
    • 2013
  • 산화 이리듐은 물의 산화반응에 대해 좋은 전기촉매 물질로서 많은 연구가 이루어 지고 있다. 최근 전기화학적 증폭방법을 이용하여 산화 이리듐 나노입자의 개별적인 촉매특성을 연구한 결과를 보면 촉매반응에 의한 전류가 지속적으로 유지되지 않고 시간에 따라 감소하는 결과가 얻어 졌다. 이러한 촉매특성의 사라짐에 대한 원인을 규명하고자 사이즈가 큰 이리듐전극을 산화시킨 산화이리듐 전극에서 물의 산화반응을 진행시켰다. 그 결과 나노입자에서와 유사하게 전류가 감소하는 현상이 관찰되었다. 큰 전극에서의 실험에서는 발생하는 산소방울을 관찰 할 수 있었는데 산소방울의 발생 주기가 전류의 증감주기와 일치하는 것으로 보아 전류의 감소는 산소방울에 의한 버블 과전압 때문으로 생각된다.

나노초의 발진 기동 시간과 28 %의 튜닝 대역폭을 가지는 버블형 동작감지기용 광대역 콜피츠 전압제어발진기 (Wideband Colpitts Voltage Controlled Oscillator with Nanosecond Startup Time and 28 % Tuning Bandwidth for Bubble-Type Motion Detector)

  • 신임휴;김동욱
    • 한국전자파학회논문지
    • /
    • 제24권11호
    • /
    • pp.1104-1112
    • /
    • 2013
  • 본 논문에서는 감지기에서 특정 거리만큼 떨어진 곳에 버블 형태의 감지 영역을 형성하는 새로운 버블형 동작 감지기를 위해 나노초의 발진 기동 시간과 8.35 GHz의 중심주파수를 가지는 광대역 콜피츠 전압제어발진기를 설계 및 제작하였다. 전압제어발진기는 HEMT 소자 및 콜피츠 궤환 구조를 이용한 부성 저항부와 바랙터 다이오드 및 단락된 마이크로스트립 분기 선로를 이용한 공진부로 구성되었다. 패키지된 트랜지스터의 기생 인덕턴스로 인해 8.1 GHz에서 용량성 값에서 유도성 값으로 변하는 부성 저항부의 리액턴스 변화는 마이크로스트립 분기 선로와 직렬 캐패시터를 이용하여 보상하였다. 부성 저항 값을 결정하는 궤환 캐패시터들의 값을 조정함으로써 부성 저항 값 변화에 따른 발진 기동 시간 개선 여부와 부성 저항부의 입력 리액턴스 기울기 변화에 따른 대역폭 개선 여부도 조사되었다. 제작된 전압제어발진기는 2.3 GHz(28 %)의 튜닝 대역폭과 4.1~7.5 dBm의 출력 전력, 그리고 2 nsec 이하의 발진 기동 시간을 가지는 것으로 측정되었다.

제주 하수처리장 재이용사업 소개(판포) (Introduction of Wastewater Reuse Project in Jeju Island)

  • 이광야;김해도;조진훈;김영진;강수만
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2012년도 학술발표회
    • /
    • pp.469-469
    • /
    • 2012
  • 제주 지역은 대부분 지하수를 이용하고 있으며, 제주 서부지역의 경우, 지하수의 과다한 취수로 인해 지하수 하강은 물론 해수침투현상도 나타나고 있다.(제주미디어 2009.10) 제주지역의 지하수 적정 개발량은 약 97%에 이르고 있어 국지적으로는 지하수 개발이 한계에 이른 것으로 평가된다. 따라서, 농촌용수 공급을 위한 사업이 필요하며, 농업 환경 피해를 최소화할 수 있는 방안이 필요하다. 또한 농촌지역의 도시화에 따라 하수처리장의 농촌지역에도 늘어가고 있으며 이제는 농촌지역과 도시지역이 구분되지 않고 혼합되어 있는 형태로 발전하고 있기 때문에 과거의 농업활동도 변화되고 있으며, 하천에서 취수하는 용수중에서 농업용수로의 사용이 부적합한 용수가 취수되고 있다. 따라서 하수처리수의 농업용수 재이용시스템과 같이 수처리를 이용한 농업용수의 공급방안이 확대될 것으로 판단된다. 한국농어촌공사 농어촌연구원에서는 (주)필로스, (주)블루인바이로먼트엔텍과 함께 글로벌탑 환경기술개발사업의 과제를 수행하고 있으며, 본 연구를 통하여, 고내구성 고기능성의 복합막 기능이 부여된 UF/NF 분리막 소재 및 모듈을 개발하고 전기분해/오존조합에 의한 에너지 절약형 재이용수 공정기술을 개발하여, 판포하수처리장을 Test-bed로 선정하여 개발 기술을 적용하고자 한다. 제주도 한경면 판포리에 위치한 판포하수처리장은 하수재이용 사업을 통해 수처리 및 용수 공급 관로가 설치되어 있으며, 개발한 재이용수를 현지에서 공급 활용할 수 있어, 연구개발에 국한되지 않고 실증 플랜트에서 용수 사용자까지 연결이 가능하여 최적의 입지 연건을 가지고 있다. 개발될 시스템은, 유입조, ECR 반응조, AOPs, 나노버블을 이용한 막세정 시스템, UF/NF 시스템으로 공정이 설계되며, 제염처리는 물론 제주지역의 농업용수로써 안정적인 용수를 확보할 수 있는 시스템을 구축하고 있다. 본 연구개발을 통한 최종 목표는 하수처리장의 방류수 고도처리를 통해 도시, 농촌지역에 필요한 고품질 맞춤형 재이용수로 공급하고, 국내 외 하수 재이용시장으로 진출하는데 있다.

  • PDF

나노 버블과 메가소닉 초음파를 이용한 반도체 웨이퍼 세정장치 개발 (Development of Wafer Cleaning Equipment Using Nano Bubble and Megasonic Ultrasound)

  • 김노유;이상훈;윤상;정용래
    • 반도체디스플레이기술학회지
    • /
    • 제22권4호
    • /
    • pp.66-71
    • /
    • 2023
  • This paper describes a hybrid cleaning method of silicon wafer combining nano-bubble and ultrasound to remove sub-micron particles and contaminants with minimal damage to the wafer surface. In the megasonic cleaning process of semiconductor manufacturing, the cavitation induced by ultrasound can oscillate and collapse violently often with re-entrant jet formation leading to surface damage. The smaller size of cavitation bubbles leads to more stable oscillations with more thermal and viscous damping, thus to less erosive surface cleaning. In this study, ultrasonic energy was applied to the wafer surface in the DI water to excite nano-bubbles at resonance to remove contaminant particles from the surface. A patented nano-bubble generator was developed for the generation of nano-bubbles with concentration of 1×109 bubbles/ml and nominal nano-bubble diameter of 150 nm. Ultrasonic nano-bubble technology improved a contaminant removal efficiency more than 97% for artificial nano-sized particles of alumina and Latex with significant reduction in cleaning time without damage to the wafer surface.

  • PDF

유방암 동물모델에서의 저강도 집속초음파를 이용한 마이크로버블 및 마이크로버블-나노물질 복합체 기반 항암제 전달 효율 검증 (Effects of Anticancer Drug Delivery based on Microbubble and Microbubble-Nanoparticle Complex using Low-Intensity Focused Ultrasound in Breast Cancer Animal Model)

  • 백희규;하신우;허형규;정병진;한문;문형원;김상균;이학종;박주영
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권2호
    • /
    • pp.39-47
    • /
    • 2019
  • Ultrasound sonication along with microbubble (MB) could enhance drug delivery to promote the absorption of anticancer drugs into cancers in a noninvasive and targeted manners. In this study, we verify the acute drug delivery enhancement (within an hour) of two representative focused ultrasound driven drug delivery enhancement methods (MB and Doxorubicin-coated Nanoparticle complex (MB-NP) based). Experiments were conducted using in vivo mouse model with MDA-MB-231 breast cancer cell line. Ultrasound generated by single-element 1 MHz focused ultrasound transducer was delivered in pulsed sonication consisted of 0.125 msec bursts at a pulse repetition frequency of 2 Hz for 20 seconds without a significant increase in local temperature (less than $0.1^{\circ}C$) or hemorrhage. Doxorubicin concentrations in tumors were improved by 1.97 times in the case of MB-NP, and 1.98 times by using Doxorubicin and MB separately. These results indicate anticancer drug delivery based on MB and MB-NP can significantly improve the effect of anticancer drugs delivered to tumors in a short time period by using low-intensity focused ultrasound.

선박용 디젤엔진 SCR 시스템 요소 기술에 관한 기초 연구 (Preliminary Study on Factor Technology of Selective Catalytic Reduction System in Marine Diesel Engine)

  • 박윤용;송하철;안기주;심천식
    • 한국항해항만학회지
    • /
    • 제40권4호
    • /
    • pp.173-181
    • /
    • 2016
  • 2016년부터 배출통제지역(ECA : Emission Control Atea)을 운항하는 선박에 대하여 배출되는 NOx(질소산화물) 및 SOx(황산화물)의 배기량 감소규제가 강화되었다. 상기의 규제 물질 중 NOx를 제거하는 탈질장비 중 선택적 촉매 환원(SCR : Selectivity Catalytic Reduction) 시스템은 효율이 높고 상업적으로 많이 활용되고 있으나, 높은 온도에서 요소수가 활성화되는 단점이 있다. 이에 초미세기포를 이용하여 낮은 온도에서도 반응할 수 있는 요소수 및 요소수 활성화 기기를 개발하여 상기의 문제점들을 최소화 할 수 있도록 하였다. 또한 SCR 시스템의 효율성을 향상시키는 방안을 마련하기 위하여, ANSYS-CFX package를 이용한 전산유체역학(CFD : Computational fluid dynamics)기법을 사용하였다. Navier-Stokes 방정식을 해석의 지배방정식으로 적용하여 SCR 시스템의 점성유동해석 시뮬레이션을 수행하였다. SCR 시스템의 형상은 CATIA V5를 사용하여 3D 모델링을 하였고, SCR 시스템의 효율성을 비교하기 위해 요소수 분사 노즐의 위치를 요소수 분사 노즐은 배기관의 입구로부터 1/3, 1/2, 2/3로 변경하며 확인하였다. 또한, 노즐의 분사구 수가 SCR 시스템의 효율에 미치는 영향을 확인하기 위하여 분사구 수가 4, 6, 8개일 경우를 시뮬레이션 하여 비교 분석하였다. 시뮬레이션 결과 배기관 입구에 가까울수록, 분사구 수가 많을수록 효율이 향상됨을 확인하였다.

마이크로-나노버블 반응조를 이용한 미생물성장 동력학 계수의 추정에 관한 연구 (Estimation of Kinetic Parameters for Biomass Growth Using Micro-nano Bubbles Reactor)

  • 한영립;정병길;정유진;조도현;성낙창
    • 한국환경과학회지
    • /
    • 제19권5호
    • /
    • pp.647-653
    • /
    • 2010
  • The objectives of this research are to evaluate and compare the oxygen transfer coefficients($K_{La}$) in both a general bubbles reactor and a micro-nano bubbles reactor for effective operation in sewage treatment plants, and to understand the effect on microbial kinetic parameters of biomass growth for optimal biological treatment in sewage treatment plants when the micro-nano bubbles reactor is applied. Oxygen transfer coefficients($K_{La}$) of tap water and effluent of primary clarifier were determined. The oxygen transfer coefficients of the tap water for the general bubbles reactor and micro-nano bubbles reactor were found to be 0.28 $hr^{-1}$ and 2.50 $hr^{-1}$, respectively. The oxygen transfer coefficients of the effluent of the primary clarifier for the general bubbles reactor and micro-nano bubbles reactor were found be to 0.15 $hr^{-1}$ and 0.91 $hr^{-1}$, respectively. In order to figure out kinetic parameters of biomass growth for the general bubbles reactor and micro-nano bubbles reactor, oxygen uptake rates(OURs) in the saturated effluent of the primary clarifier were measured with the general bubbles reactor and micro-nano bubbles reactor. The OURs of in the saturated effluent of the primary clarifier with the general bubbles reactor and micro-nano bubbles reactor were 0.0294 mg $O_2/L{\cdot}hr$ and 0.0465 mg $O_2/L{\cdot}hr$, respectively. The higher micro-nano bubbles reactor's oxygen transfer coefficient increases the OURs. In addition, the maximum readily biodegradable substrate utilization rates($K_{ms}$) for the general bubbles reactor and micro-nano bubbles reactor were 3.41 mg COD utilized/mg active VSS day and 7.07 mg COD utilized/mg active VSS day, respectively. The maximum specific biomass growth rates for heterotrophic biomass(${\mu}_{max}$) were calculated by both values of yield for heterotrophic biomass($Y_H$) and the maximum readily biodegradable substrate utilization rates($K_{ms}$). The values of ${\mu}_{max}$ for the general bubbles reactor and micro-nano bubbles reactor were 1.62 $day^{-1}$ and 3.36 $day^{-1}$, respectively. The reported results show that the micro-nano bubbles reactor increased air-liquid contact area. This method could remove dissolved organic matters and nutrients efficiently and effectively.

유류오염토양 처리를 위한 마이크로나노버블 토양세척에 관한 연구 (A Study on the Treatment of Oil Contaminated Soils with Micro-nano Bubbles Soil Washing System)

  • 최호은;정진희;한영립;김대용;정병길;최영익
    • 한국환경과학회지
    • /
    • 제20권10호
    • /
    • pp.1329-1336
    • /
    • 2011
  • The objectives of this study are to examine the processing of oils contamination soil by means of using a micronano-bubble soil washing system, to investigate the various factors such as washing periods, the amount of micro-nano bubbles generated depending on the quantity of acid injection and quantity of air injection, to examine the features involved in the elimination of total petroleum hydrocarbons (TPHs) contained in the soil, and thus to evaluate the possibility of practical application on the field for the economic feasibility. The oils contaminated soil used in this study was collected from the 0~15 cm surface layer of an automobile junkyard located in U City. The collected soil was air-dried for 24 hours, and then the large particles and other substances contained in the soil were eliminated and filtered through sieve No.10 (2 mm) to secure consistency in the samples. The TPH concentration of the contaminated soil was found to be 4,914~5,998 mg/kg. The micronano-bubble soil washing system consists of the reactor, the flow equalization tank, the micronano- bubble generator, the pump and the strainer, and was manufactured with stainless material for withstanding acidic phase. When the injected air flow rate was fixed at 2 L/min, for each hydrogen peroxide concentrations (5, 10, 15%) the removal percents for TPH within the contaminated soil with retention times of 30 minutes were respectively identified as 4,931 mg/kg (18.9%), 4,678 mg/kg (18.9%) and, 4,513 mg/kg (17.7%). And when the injected air flow rate was fixed at 2 L/min, for each hydrogen peroxide concentrations (5, 10, 15%) the removal percents for TPH within the contaminated soil with retention times of 120 minutes were respectively identified as4,256 mg/kg (22.3%), 4,621 mg/kg (19.7%) and 4,268 mg/kg (25.9%).