• Title/Summary/Keyword: 김주용

Search Result 498, Processing Time 0.023 seconds

Fabrication of Ceramic Particles Deposited Nano-web using Electrospinning Process and Its Far-infrared Ray Emission Property (원적외선 방출 특성을 갖는 나노 웹의 제조 및 원적외선 방사 특성에 관한 연구)

  • Hong, So-Ya;Lee, Chang-Hwan;Kim, Joo-Yong
    • Textile Coloration and Finishing
    • /
    • v.22 no.2
    • /
    • pp.118-122
    • /
    • 2010
  • The interest in textile which has far-infrared ray emissive property has been increased in the field of biophysics and medicine. In this study, far-infrared ray emissive polyurethane nano-web was obtained using electrospinning of polyurethane(PU) solution mixed with ceramics powder and far-infrared ray emissive properties of nano-web were evaluated by measuring far-infrared ray emission power and emissivity(%). To investigate the influence of concentration of ceramics powder in PU solution and temperature for far-infrared ray emissive properties, far-infrared ray emissivity was measured at varied temperature using various nano-web including varied concentration of ceramics powder. Polyurethane nano-web was characterized by SEM to observe the deposition of ceramics powder on polyurethane nano-web surface. The far-infrared ray emissivity was increased with the concentration of ceramics powder in the nano-web. The far-infrared ray emission power was enhanced with increasing temperature of the samples; however, far-infrared ray emissivity was decreased with increasing temperature because the increase of emission power of ceramic containing nano-web was lower than the emission power of black body one.

Study on Abrasion Resistance of Mooring Ropes (해양용 로프의 내마모성에 관한 연구)

  • Lee, Eun-Joo;Lee, Chang-Hwan;Kim, Joo-Yong
    • Textile Coloration and Finishing
    • /
    • v.22 no.4
    • /
    • pp.373-379
    • /
    • 2010
  • The laboratory inspection and analysis of several types of ropes such as edge tensile test, D/d tensile test and abrasion test were carried out in order to investigate the abrasion degradation by external damage and to obtain the fundamental data for measurement against the abrasion. PET ropes were socketed and evaluated under tensile testing. A yarn-on-yarn abrasion test machine has been developed to study the damage and failure associated with rubbing between fiber surfaces. The abrasion test method consists of sliding a length of interwrapped yarn against itself in a reciprocating fashion, either dry or immersed in liquid. It has also been adapted to measure yarn-on-yarn friction. The influence of spin finish on yarn friction and abrasion was investigated extensively. This study indicates that finish has a major effect not only on yarn performance but also on rope performance under the marine environment.

Evaluation of Heavy Metal Contamination in Geochemical Environment around the Abandoned Coal Mine - With special reference to geochemical environment around the Imgok Creek in the Gangreung Coal Field - (폐석탄광 주변 지구화학적 환경의 중금속 오염 평가 - 강릉탄전 임곡천 일대를 중심으로 -)

  • Chon, Hyo-Taek;Kim, Ju-Yong;Choi, Si-Young
    • Economic and Environmental Geology
    • /
    • v.31 no.6
    • /
    • pp.499-508
    • /
    • 1998
  • The Imgok Creek is located in the Gangreung coal field, which has been known that sulfides are more abundant than other coal fields in Korea, and it has been severly contaminated by acid mine drainage (AMD) discharging from the abandoned coal mines, such as the Youngdong, the Dongduk and the Waryong coal mines. The purposes of this study are to synthetically assess the contamination of natural water, stream sediment and cultivated soils, and to provide the basic data for AMD treatment. Geochemical samples were collected in December, 1996 (dry season) and April, 1997 (after three day's rainfall). TDS of the Youngdong mine water was remarkably higher than those of other mine waters. In the Imgok Creek, concentrations of most elements, except Fe decreased with distance by dilution caused by the inflow of uncontaminated tributaries. From the results of NAMDI and $I_{geo}$ calculation, the Youngdong coal mine was the main contamination source of the study area. Groundwater pollution was not yet confirmed in this study and the paddy and farm land soils were also not yet contaminated by mining activity based on the pollution index ranging from 0.27 to 0.47.

  • PDF

New Uninterruptible Power Supply Using the Converter which is Secondary Auxiliary Soft Switching High Frequency Insulating PWM AC/DC (2차측 보조 소프트 스위칭 고주파 절연형 PWM AC/DC 컨버터를 이용한 새로운 무정전전원장치)

  • Suh, Ki-Young;Mun, Sang-Pil;Kim, Ju-Yong;Lee, Hyun-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.16-21
    • /
    • 2005
  • In paper, propose new partial resonance ZCS PWM controlled High frequency insulating Full-bridge DC/DC converter not using exciting current of high frequency transformer. It is compared with the existing principles in characteristics. It also realizes a widely stabilized ZVS operating using new ON-OFF control method at synchronized power rectification MOSFET of high frequency insulating transformer secondary. Besides, it is brought over 97[%] measurement efficiency by proposed DC-DC converts. It is proved effectiveness of new methods using DC UPS PWM rectifier as switching power supply.

Implementation of a Photovoltaic System Simulator for Interconnecting with Bipolar ±750V DC distribution Grid (바이폴 ±750 직류 배전망 연계용 태양광 발전 시뮬레이터 구현)

  • Kim, Tae-Hoon;Kim, Seok-Woong;Cho, Jin-Tae;Kim, Ju-Yong;Jung, Jae-Seung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.11
    • /
    • pp.1800-1805
    • /
    • 2016
  • The micro-grid designed as bipolar ${\pm}750V$ low-voltage DC power distribution system demonstrated by KEPRI, demands interconnection of a number of small decentralized power source including variable renewable generator. Therefore, variable researches for the influence of interconnection with the bipolar typed DC grid and these variable power sources are required for superior quality of power distribution. Renewable power generation simulators for the bipolar ${\pm}750V$ low-voltage DC power distribution system are necessary for such researches. In this paper, we carry out a research on the photovoltaic simulator that be actually able to interconnect with a bipolar ${\pm}750V$ low-voltage micro-grid. Simulator for this research is not only able to simulate photovoltaic generation according to weather informations and PV modules characteristics, but also contribute to stabilization of bipolar ${\pm}750V$ low-voltage of the system. Therefore, the simulator was designed to develop a system that can situationally respond to variable control algorithms such as the MPPT control, droop control, EMS power control, etc.

A Feasibility Study on DC Microgrids Considering Energy Efficiency (에너지 효율분석을 통한 DC 마이크로그리드의 타당성 검토)

  • Yu, Cheol-Hee;Chung, Il-Yop;Hong, Sung-Soo;Chae, Woo-Kyu;Kim, Ju-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.9
    • /
    • pp.1674-1683
    • /
    • 2011
  • More than 80% of electric loads need DC electricity rather than AC at the moment. If DC power could be supplied directly to the terminal loads, power conversion stages including rectifiers, converters, and power adapters can be reduced or simplified. Therefore, DC microgrids may be able to improve energy efficiency of power distribution systems. In addition, DC microgrids can increase the penetration level of renewable energy resources because many renewable energy resources such as solar photovoltaic(PV) generators, fuel cells, and batteries generate electric power in the form of DC power. The integration of the DC generators to AC electric power systems requires the power conversion circuits that may cause additional energy loss. This paper discusses the capability and feasibility of DC microgrids with regard to energy efficiency analysis through detailed dynamic simulation of DC and AC microgrids. The dynamic simulation models of DC and AC microgrids based on the Microgrid Test System in KEPCO Research Institute are described in detail. Through simulation studies on various conditions, this paper compares the energy efficiency and advantages of DC and AC microgrids.

Topology of the Novel High Frequency Insulated Soft Switching PWM DC-DC Converter (새로운 고주파 절전형 소프트 스위칭 PWM DC-DC 컨버터의 토폴로지)

  • Kwon, Soon-Kurl;Suh, Ki-Young;Kim, Ju-Yong;Lee, Su-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.119-124
    • /
    • 2006
  • A novel high frequency insulated soft switching PWM DC-DC converter circuit is proposed and then it is achieved the high-efficiency. This converter does not use the o(citing current of a high frequency transformer but use inductance. Then it realizes a widely stable zero voltage switching operation with the use of a novel ON-OFF control method at synchronized rectification power MOSEFETs of the high frequency insulated transformer secondary. Therefore, it is brought over 97[%] measurement efficiency by proposed DC-DC converter.

Development of High Efficiency DC-DC Converter Circuit Topology for Renewable Energy Application (신재생에너지 연계용 고효율 승압형 DC-DC Converter 회로 토폴로지 개발)

  • Jung, Tae-Uk;Kim, Ju-Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.105-111
    • /
    • 2010
  • This article studies the design of DC-DC Converter to convert low-voltage energy sources generated from renewable power like battery power, photovoltaic power, or fuel cells into high-voltage ones. The circuit topology of H-bridge Converter to convert input voltage, 24[V], into out voltage, 400[V], was realized through applying phase shift angle control so as to manage electric power and voltage in the output side. The advantages of the converter system suggested are the low cost as well as current stress reduction, high efficiency, reliability, and simplified maintenance. It is also found that the system is highly useful to produce residential electric power.

The Use and Findings of Ultrasound in the Wrist Joint (완관절의 초음파 소견 및 이용)

  • Kim, Jung-Han;Kim, Joo-Yong;Kwon, Yong-Uk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.2
    • /
    • pp.132-137
    • /
    • 2014
  • We can test for small structures located at the surface layer as high resolution ultrasonic techniques and small probes were developed. Accordingly ultrasound became a useful tool in the diagnosis and treatment of wrist diseases. It is important to understand the anatomical structures and apply clinical features as well as these technical aspects when using ultrasound. The purpose of this article is to evaluate the usefulness and approach of ultrasound about typical diseases according to the area of the wrist pain.

  • PDF

Development of Longtime Reliability Assessment Method of Polymer Housed Distribution Surge Arresters using Accelerated Aging Test (가속열화시험을 이용한 배전용 폴리머피뢰기의 장기신뢰성 평가기법 개발)

  • Kim, Ju-Yong;Song, Il-Keun;Moon, Jae-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.141-150
    • /
    • 2006
  • In this study we developed accelerated aging test cycle and equipment which can simulate domestic weather condition. And we proposed long term reliability assessment method for polymer housed distribution surge arresters. We carried out electrical and chemical analysis of the arresters which are used for accelerated aging test and outdoor exposure test. Through the analysis we verified the capability of the proposed method and we presented characteristic data for maintenance of domestic arresters.