• Title/Summary/Keyword: 김두현

Search Result 335, Processing Time 0.026 seconds

Development of Hardware and Monitoring Software for Stable Operation of Fire Pumps (소방펌프의 안정적 운영을 위한 하드웨어 및 모니터링 소프트웨어 개발)

  • Ku, Bonhyu;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.28-35
    • /
    • 2022
  • This study is aimed to develop a safety diagnosis system for fire pumps that detects normal and abnormal signals for the stable operation of the system. Hence, the following activities were carried out: first, a threshold value was identified for the normal operation and six abnormal operations (adherence of impeller, absence of water source, separation of pump and motor, run-stop operation, air inflow into the casing, and reverse-phase loss of the power line) reflecting changes in the current, flow and pressure of fire pumps; secondly, based on the identified signals, an algorithm capable of detecting three abnormal signals was developed and in terms of hardware, a current, pressure and flow sensor suitable for the analogue input values of NI-6009 was designed and installed. This combination of the hardware and software is applicable as a diagnosis system to ensure the stable operation of fire pumps.

Integrated System of Multiple Real-Time Mission Software for Small Unmanned Aerial Vehicles (소형 무인 항공기를 위한 다중 실시간 미션 소프트웨어 통합 시스템)

  • Jo, Hyun-Chul;Park, Keunyoung;Jeon, Dongwoon;Jin, Hyun-Wook;Kim, Doo-Hyun
    • Telecommunications review
    • /
    • v.24 no.4
    • /
    • pp.468-480
    • /
    • 2014
  • The current-generation avionics systems are based on a federated architecture, where an electronic device runs a single software module or application that collaborates with other devices through a network. This architecture makes the internal system architecture very complicate, and gives rise to issues of Size, Weight, and Power (SWaP). In this paper, we show that the partitioning defined by ARINC 653 can efficiently deal with the SWaP issues on small unmanned aerial vehicles, where the SWaP issues are extremely severe. We especially install the integrated mission system on real hexacopter and quadcopter and perform successful flight tests. The presented software technology for integrated mission system and software consolidation methodology can provide a valuable reference for other SWaP sensitive real-time systems.

Analysis of Installation Environment and Fire Risk of Induction Motors Installed in the Curing Process of a Rubber Product Manufacturing Plant (고무제품제조공장의 가류공정에 설치된 유도전동기의 설치환경 및 화재위험성 분석)

  • Jong-Chan Lee;Doo-Hyun Kim;Sung-Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.2
    • /
    • pp.23-29
    • /
    • 2023
  • This study analyzed the fire status of a rubber product manufacturing factory based on 19 years of fire data. Through the analysis of the current state of fire, electrical fires accounted for 58.19%, and among electrical fires, motor fires were the highest at 26.21%. For the motor fire occurrence process, the curing process accounted for the highest rate of 51.9%. Therefore, the installation environment was investigated for the motor in the curing process, and it was confirmed that the motor's maximum ambient temperature exceeded 40℃. In particular, in the case of the motor for curing operation, the motor was installed in a separate motor room, so the average indoor temperature was 48.10℃ and the motor frame's maximum temperature was 72.80℃. In this study, the risk of motor fire was confirmed through a field survey, and a safety management plan was derived by finding a process with high fire risk and conducting an experiment on the motor's installation environment and electrical characteristics in that process.

Proposal of a Black Ice Detection Method Using Vehicle Sensors to Reduce Traffic Accidents (교통사고 경감을 위한 차량 센서를 사용한 블랙아이스 탐지 방법 제안)

  • Kim, Hyung-gyun;Kim, Du-hyun;Baek, Seung-hyun;Jang, Min-seok;Lee, Yonsik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.524-526
    • /
    • 2021
  • As the invention of automobiles and construction of roads for vehicles began, the occurrence of traffic accidents began to increase. Accordingly, efforts were made to prevent traffic accidents by changing the road construction method and using signal systems such as traffic lights, but until now, numerous human and property damages have occurred every year due to traffic accidents caused by freezing of the road due to bad weather. In this paper, we propose a method of transmitting ice detection data detected using vehicle sensor data to vehicle navigation to reduce traffic accidents caused by road freezing.

  • PDF

Characteristics of Insulation Resistance of Cable according to Temperature Rise and Over-Current for Process of the Melting Furnace (용해로의 공정상 온도상승 및 과전류에 따른 케이블의 절연저항 특성)

  • Suk Bong Ko;Doo-Hyun Kim;Sung-Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.2
    • /
    • pp.22-27
    • /
    • 2024
  • The purpose of this study is to explore the trend in insulation resistance values according to temperature and overcurrent by conducting an investigation on the actual condition and experiments on the electrical wiring during the melting furnace process. In addition, the Arrhenius equation is used to determine whether temperatures in the furnace operating process can be applied to the actual field. In the investigation of the actual condition, the insulation resistance started to decrease seven years after replacement, even though cables in oil pump A were replaced in 2010. Both the experimental and theoretical values of the insulation resistance obtained using the Arrhenius equation decreased with an increase in temperature. Errors in insulation resistance (MΩ) values between tests and the Arrhenius equation ranged from ±2 to ±10, demonstrating a high similarity. Results revealed that when the insulation resistance cannot be measured in a manufacturing workplace (quarterly analysis), it can be estimated by partially applying the Arrhenius equation.

Risk Priority Analysis for Preventing Electrical Fires in Food Manufacturing Electrical Facilities (식료품제조업 전기설비의 전기화재방지를 위한 위험우선순위 분석)

  • Seung Ku Lee;Doo Hyun Kim;Sung Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.1
    • /
    • pp.16-26
    • /
    • 2024
  • This study aims to introduce a method for risk assessment analysis aimed at preventing electrical fires within the manufacturing industry. Initially, we provided a functional block diagram illustrating the electrical equipment employed in various processes within a food manufacturing company in Chungcheongbuk-do. Subsequently, we categorized the components of each machine outlined in the functional block diagram and determined the priority of failure for each classified component. Upon implementing the model in the frying process of the food manufacturing company, specific components, including MC, motor, mixer heater, electric wiring, and terminal block, exhibit a risk priority number (RPN) of 40 or higher. This identified an electrical issue within the manufacturing process and environment. Consequently, we propose a methodology to identify latent failure modes that could escalate into fires or systemic issues if not promptly addressed. It is essential to note that while the FMEA presented in this study may not immediately impact food manufacturing, its applicability extends to various workplaces.

Analysis on the Voltage, Current and Temperature Signals for Free and Locked Operation of Three Speed Electric Fan (3단 스피드 선풍기 모터의 정상 및 고정 운전에 대한 전압, 전류 및 온도 신호 분석)

  • Kim, Yoon Bok;Kim, Doo Hyun
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.87-91
    • /
    • 2014
  • This paper is aimed to find electrical fire danger for analyzing the characteristics of temperature, current and voltage signals for motor on electric fan. In order to attain this purpose, detected were the temperature, current and voltage signals on electric wire with free (normal state) and locked (abnormal state) motor. For voltage and current signals, voltage signal is no big difference with normal and abnormal states and current signal is higher in abnormal state (highest 309 mA) than the normal state (highest 203 mA). In the case of Temperature signal, the temperature distribution of the motor as a whole is different. It is difference in the case of the normal state $4^{\circ}C$ and the abnormal state $18^{\circ}C$. In particular, most of the electric wiring to the motor of the fan is attached to the fixture of motor back. Considering at allowable temperature ($60^{\circ}C$) of the electric wire could be accelerated to insulation deterioration. The results of this study will be effectively used in analyzing for electric fire and developing the preventive devices of electric fan.

Prediction of Characteristics for the Air-side Particulate Fouling in Finned-Tube Heat Exchangers of Air Conditioners used in the Field (실공간 사용 공기조화기용 열교환기의 공기측 파울링 특성 예측)

  • Ahn, Young-Chull;Jung, Sung-Hak;Hwang, Yu-Jin;Lee, Chang-Gun;Kim, Doo-Hyun;Jung, Seong-Ir;Lee, Jae-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.8
    • /
    • pp.563-568
    • /
    • 2007
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performances of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. An empirical modeling equation has been derived from the experimental results using accelerated tests and it showed good predictions of the fouling characteristics of the slitted finned tube heat exchangers. However the modeling equation predicts only the fouling characteristics of new heat exchangers and it can not predicts fouling characteristics obtained from actual field data which contains the effect of hydrophilicity deterioration. Therefore an modified modeling equation is proposed and it shows good predictions of the actual fouling characteristics of finned-tube heat exchangers.

Allelopathic Effect against Seed Germination and Seedling Growth of Picea jezoensis of Leaf Aqueous Extracts from Competition Species (경쟁 수종들의 잎 추출 수용액이 가문비나무 종자발아 및 유묘생장에 미치는 타감효과)

  • Kim, Gil Nam;Han, Sim-Hee;Shin, Soo Jeong;Kim, Du-Hyun
    • Journal of Korean Society of Forest Science
    • /
    • v.105 no.1
    • /
    • pp.86-92
    • /
    • 2016
  • This study was conducted to evaluate the allelopathic effect against the regeneration of the seedling and to identify the presence of allelochemicals in Picea jezoensis natural population in Jirisan. Water-soluble extracts from leaves of different competition plants were collected to test their effects on seed germination and seedling growth of P. jezoensis. Phenolic compounds from leaves were quantified using GC/MS. The seed germination rate and seedling growth of P. jezoensis was reduced by extracts of all competition plants leaves. Monoterpenoids compound, which are generally well known in the allelochemicals has been detected in the leaf extracts. In conclusion, allelopathic chemicals of competition vegetation in P. jezoensis natural population could inhibit the seed germination and seedling growth of P. jezoensis, that is considered as a result of the lower seedling establishment.

A Fire Detection System Using Fuzzy Logic with Input Variables of Temperature and Smoke Density (열과 연기농도를 입력변수로 갖는 퍼지로직을 이용한 화재감지시스템)

  • Hong Sung-Ho;Kim Doo-Hyun;Kim Sang-Chul
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.42-51
    • /
    • 2004
  • This paper presents a study on the analysis of fire detection system using fuzzy logic with input variables of temperature and smoke density. The input variables for the fuzzy logic algorithm are measured by fire experiment of small scale with temperature detector and smoke detector. The antecedent part of fuzzy rules consists of temperature and smoke density, and the consequent part consists of fire possibility. Also the triangular fuzzy membership function is chosen for input variables and fuzzy rules to simplify computation. In order to calculate fuzzy values of such fuzzy system, a computer program is developed with Matlab based on graphics user interface. The experiment was conducted with paper and ethanol to simulate flaming fire and with plastic and sawdust to model smoldering fire. The results showed that the fire detection system presented here was able to diagnose fire very precisely. With the help of algorithms using fuzzy logic we could distinguish whether fire or not.