• Title/Summary/Keyword: 기폭화약

Search Result 62, Processing Time 0.038 seconds

Development and Performance Evaluation of Shaped Charge for Controled Blasting (조절발파를 위한 성형폭약의 제작과 성능 평가)

  • Kim, Jung-Gyu;Yang, Hyung-Sik;Kim, Jong-Gwan
    • Explosives and Blasting
    • /
    • v.34 no.3
    • /
    • pp.1-9
    • /
    • 2016
  • The shaped charge were made for identifying the effect of controled blasting using relatively low VOD explosive for cutting rock mass with changing quality and thickness of metal liner. The metal liner was attached on both sides of a charge for directional cutting, when the shaped charge exploded in rock mass. Also, a efficiency of shaped charge was identified by concrete member experiment. And a center guide used for maintaining stand-off between shaped charge and hole wall. A case of Fe liner of thickness 0.8mm formed the deepest notch of experiments and the directional cutting of concrete member was identified.

Case Study on the Explosive Demolition of DCRE Incheon Plant (디씨알이 인천공장 발파해체 시공사례)

  • Kim, Sang-Min;Park, Keun-Sun;Kim, Ho-Jun;Kim, Hee-Do;Kim, Gab-Soo;An, Kyung-Ro
    • Explosives and Blasting
    • /
    • v.37 no.1
    • /
    • pp.34-47
    • /
    • 2019
  • This case study is concerned with the project of the explosive demolition for the DCRE Incheon plant located in Hakik district in Incheon city. The building was severely aging due to the high temperature and sea winds of hundreds of degrees emitted by chimney-shaped steel structures inside the building. Due to this, the concrete of the column and the beam fell off and rusted rebar were exposed, and some of the slabs were severely damaged, making it difficult for workers to access the structure. Therefore, it is not possible to apply a mechanical demolition method in which heavy equipment enters the interior of the building, and an explosive demolition method was applied to allow the building to be demolished without dismantling the internal facilities of the building. The order of blasting proceeded in the order of (1) building ${\rightarrow}$ (2) chimney 2 ${\rightarrow}$ (3) chimney 1. A total of 406 electronic detonators (Unitronic 600) was used to sequentially initiate the explosives installed at appropriate in building and chimneys.

An Analysis of Optimized Position of the Fiber Optic Sensor Istalled near the Bridge Wire of Electro-explosive Device (전기기폭장치의 발열선에 설치되는 광섬유 센서의 최적위치 분석)

  • 김응조;윤기은;최태인;윤태훈;김재창
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.7
    • /
    • pp.1111-1117
    • /
    • 1999
  • In order to measure the temperature of bridge wire, the explosive material is removed from EED and a fiber optic temperature sensor is installed near the bridge wire. Using the heat transfer theory, the optimum position of the fiber optic sensor in the EED is determined and the temperature-distance equation is derived from test result. The measuring technique can be utilized to the real electromagnetic radiation hazard test.

  • PDF

Hydrodynamic Analysis on Shock-induced Detonation in Pyrotechnic Initiator (파이로테크닉 착화기의 충격파 전달에 의한 폭굉 반응 해석)

  • Kim, Bohoon;Kang, Wonkyu;Jang, Seung-gyo;Yoh, Jai-ick
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.5
    • /
    • pp.19-30
    • /
    • 2016
  • We presented a hydrodynamic modeling necessary to accurately reproduce shock-induced detonation of pyrotechnic initiator. The methodology for such numerical prediction of shock propagation is quite straight forward if the models are properly implemented and solved in a well-formulated shock physics code. A series of SSGT(Small Scale Gap Test) and detailed hydrodynamic simulation are conducted to quantify the shock sensitivity of an acceptor that contains 97.5% RDX. A TBI(Through Bulkhead Initiator) system, consisting of a train configuration of Donor(HNS+HMX) - Bulkhead(STS) - Acceptor(RDX), were investigated to further validate the interaction between energetic and non-reactive materials for predicting the detonating response for successful operation of such small pyro device.

Research on the Decrease of Dud Ammunition Rate of 40mm Grenade(K200) Fuze through Quality Improvement (40mm 저속유탄(K200) 신관 품질개선을 통한 불발율 감소에 관한 연구)

  • Ju, Jin-Chun;Kim, Yong-Hwa;Ahn, Nam-Su;Kim, Sang-Min;Ha, Su-Ra
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.700-707
    • /
    • 2016
  • Recently, ammunition malfunctions of the 40mm grenade were reported during live fire training. When 72 40mm grenades were fired by the army, 11 duds were encountered. The dud ammunition rate was approximately 15%. Because ammunition is used a long time after its manufacture, it is necessary to ensure its performance after long-term storage. In this study, we attempted to decrease the dud ammunition rate of 40mm grenade (K200) fuzes through quality improvement. First, it was determined by the detonator performance test that abnormal explosions occurred due to the degradation of the detonator as a result of its aging characteristics. Second, we improved the fuze quality of the 40mm grenade. Third, we tested its shelf life to estimate its life expectancy. The shelf life of the 40mm grenade fuze obtained using the Arrhenius equation was 6.5 years for the existing grenade fuze and 45.5 years for the improved grenade fuze. This showed that the shelf life of the improved grenade was increased approximately 7 times. Therefore, the improved 40mm grenade fuze contributes to the quality improvement of the 40mm grenade by decreasing the dud ammunition rate during long term storage.

Collapse Simulations of High-Rise RC Building Using ELS Software and Application of Explosive Demolition Methods to Transition Process Analysis from Local Damage to Progressive Collapse (ELS를 이용한 고층 RC 빌딩의 붕괴해석 및 발파해체해석 기법의 국부손상-연쇄붕괴 전이과정 해석에 응용)

  • Kim, Hyon-Soo;Park, Hoon;Kim, Seung-Kon;Lee, Yeon-Gyu;Cho, Sang-Ho
    • Explosives and Blasting
    • /
    • v.29 no.2
    • /
    • pp.1-12
    • /
    • 2011
  • Progressive collapse analyses of high-rise buildings subjected to abnormal loading such as fires, impacts, earthquakes, typhoon, bomb blasts etc. are intended. However it is difficult to perform collapse experiments of the real scale building to determine the capacity of the structure under an extreme loading events. In this study, collapse behavior of a 15 story RC structure building loaded by external explosion pressures were simulated using Extreme Loading Structures (ELS) software. The standoff distance between the RC building and explosives of 1500 kg was 1, 2, 5, 10, and 15 meters. The explosive demolition analysis techniques based on removal of partial support structures following blast scenario was adapted to investigate the transition process of progressive collapse-local damage.

Numerical Study on Ground Vibration Reduction and Fragmentation in a Controlled Blasting Utilizing Directional U Shape Charge Holder (U형 장약홀더를 이용한 발파공법에서 지반진동 저감특성 및 파괴효율에 관한 수치해석적 연구)

  • Kim, Hyon-Soo;Baek, Beom-Hyun;Oh, Se-Wook;Han, Dong-Hun;Cho, Sang-Ho
    • Explosives and Blasting
    • /
    • v.34 no.1
    • /
    • pp.11-18
    • /
    • 2016
  • It is necessary to minimize ground vibration and noise due to blasting work in urban environment. The blast induced ground vibration and noise are generally generated by a portion of detonation energy, where most of the energy is utilized for rock breakage and movement of rock mass. Recently a blast method utilizing U-shaped steel charge holder was suggested to reduce the ground vibration without decreasing destructive power toward the free surface. In this study, single hole blasting utilizing U-shaped steel charge holder were simulated and the stress waves caused by the detonation of explosives were monitored using AUTODYN software. In order to examine the fragmentation efficiency of the U-shaped steel charge holder, one free face blasting models which adapt the blast induced stress waves were simulated by dynamic fracture process analysis (DFPA) code. In addition, the general blasting models were also simulated to investigate the fragmentation effectiveness of the U-shaped steel charge holder in rock blasting.

Comparative Study on the Characteristics of Ground Vibrations Produced from Borehole Blast Tests Using Electronic and Electric Detonators (전자뇌관과 전기뇌관을 사용한 시추공 발파시험에서의 지반진동 특성에 관한 비교 연구)

  • Choi, Hyung-Bin;Won, Yeon-Ho
    • Explosives and Blasting
    • /
    • v.28 no.2
    • /
    • pp.37-49
    • /
    • 2010
  • Ground vibration caused by blasting in the urban area close to structures can give some indirect damage to human body and may lead to structural damage to buildings. At the stage of design or when complaints were filed by residents, the test blasting in borehole, which is most practical for expressing simple vibration wave form quantitatively, is usually chosen for assessing the degree of damage to structures. In this paper, some lessons gained from the application of electronic detonator triggering system in borehole test blasting are presented. The difference in delay time of detonator when borehole is blasted by electronic detonator and electric detonator are discussed. The peak particle velocities measured at the structure embedded in the similar rock layer to main line of tunnel at test site and measured at the road surface just above the tunnel having different overburden layers were analysed to draw their relationship. By comparing the results with those appearing in some published literatures, the usefulness of the borehole test blasting and the importance of delay time of detonator are addressed.

Development of Linear Shaped Charges for Explosive Jet Cutting and Application Plan (폭발절단용 성형폭약의 국산화 개발 현황 및 활용화 방안)

  • 신용길;이병일;조영곤;이익주
    • Explosives and Blasting
    • /
    • v.20 no.3
    • /
    • pp.15-23
    • /
    • 2002
  • 철골구조물은 일반 철근 콘크리트 구조와는 달리 단순히 천공을 하고 폭약을 장약하여 기폭시키는 방법으로는 해체 또는 절단이 어렵다. 국내의 경우 최근 철골 구조로 건축되는 강교와 건축물 등이 증가하는 추세이며, 내구연한이 다하거나 구조적 결함으로 인하여 해체 대상으로 지목되는 철골구조물에 대해서는 특수한 형태의 해체 기술을 필요로 한다. 1997년 이후 국내에 철골구조물의 발파해체를 위하여 성형폭약에 의한 폭발절단기술에 관한 연구가 소개된 이후로 폭발절단력에 미치는 성형폭약의 라이너(Liner), 폭약의 종류, 형상 및 이격거리(Stand-off distance) 등에 대한 연구가 활발히 이루어졌으며, 또한 국산화를 위한 기초적인 설계변수에 관한 연구 등이 보고 된 바 있다. 현재 성형폭약의 사용범위가 철골구조물의 절단해체 뿐만 아니라 긴급구조를 필요로 하는 특수한 용도나 군사폭약의 해체, 항공산업 등 그 적용범위가 확대되고 있는 실정이다. 그러나, 성형폭약의 성능 향상 및 품질 보증을 위한 체계적인 설계 변수의 검토 설정에 관한 연구와 산업f'의 적용을 위한 구체적인 결과는 보고 된 바 없는 실정이다. 그래서, 보다 체계적인 현장 적용 시험 등에 대한 연구가 효율적으로 진행될 경우 국내 고유 기술에 의한 철구조물의 절단 및 해체공법에 획기적인 변화를 가져올 수 있을 것으로 기대된다. 따라서, 본 연구에서는 국산화되어 현장에 적용되고 있는 성형폭약 HAKO 제품을 기준으로 이미 국내에 알려진 성형폭약과 비교 분석하였다. 또한 보다 효율적인 산업계의 적용을 위한 각종 시험 결과 및 국산화 현황과 향후 활용 방안 등에 대하여 소개하고자 한다.

Dead Pressure and its measures of Emulsion Explosives at Small Sectional Tunnel (소단면 터널에서 에멀젼폭약의 사압현상과 대책)

  • Min, Hyung-Dong;Jeong, Min-Su;Jin, Yeon-Ho;Park, Yun-Suk
    • Explosives and Blasting
    • /
    • v.26 no.2
    • /
    • pp.29-37
    • /
    • 2008
  • In general, the size of tunnel cross section in construction site is $50{\sim}200m^2$. But, electric cable tunnel, telecommunication cable tunnel, mine tunnel. Waterproof tunnel have small cross section less than $20m^2$. There are so many problem at small sectional tunnel: restriction of equipment, dead pressure by precompression, loss of efficiency, increase of work time. Especially, explosives remainder by precompression of previous detonation is serious problem. To find its measures of dead pressure (explosives remainder), the following series of progress have been conducted: (1) survey of previous study (2) investigate causes of dead pressure (3) set up of its measures (4) application and appraisal at tunnel site. The measures, change of cut pattern, hole space over 40cm, adjustment of delay time, are proved by experimental results.