• Title/Summary/Keyword: 기포식

Search Result 140, Processing Time 0.029 seconds

Level Set Method Applied on Pseudo-compressibility Method for the Analysis of Two-phase Flow (Pseudo-compressibility 방법에서 이상유동 해석을 위한 Level Set방법의 적용)

  • Ihm Seung-Won;Kim Chongam;Shim Jae-Seol;Lee Dong-Young
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.17 no.3
    • /
    • pp.158-165
    • /
    • 2005
  • In order to analyze incompressible two-phase flow, Level Set method was applied on pseudo-compressibility formulation. Level Set function is defined as a signed distance function from the phase interface, and gives the information of the each phase location and the geometric data to the flow. In this study, Level Set function transport equation was coupled with flow conservation equations, and owing to pseudo-compressibility technique we could solve the resultant vector equation iteratively. Two-phase flow analysis code was developed on general curvilinear coordinate, and numerical tests of bubble dynamics and surging wave problems demonstrate its capability successfully.

압전형 가속도계의 설계, 제작 및 보정 II - 개발 연구 사례를 중심으로 -

  • 이종원;구경회
    • Journal of the KSME
    • /
    • v.29 no.4
    • /
    • pp.414-425
    • /
    • 1989
  • 본 연구를 통하여 원하는 감도와 부착 공진 주파수가 주어질 때 실제로 이러한 성능을 갖는 압 축식 압전형의 가속도계를 이론적으로 설계하여 제작할 수 있었으며 보정 실험을 통하여 실험 가속도계는 실제 설계값에 가까운 성능을 나타내었다. 설계, 제작된 실험 가속도계의 특성 실 험을 통하여 다음과 같은 결론을 얻었다. (1) 가속도계의 감도는 압전 소자의 압전 상수가 일 정할 때 관성 질량에 따라서만 지배되는 것이 아니라 압전 소자의 크기에 따라서도 달라진다. (2) 높은 감도의 가속도계를 설계하기 위해서는 단일 압축식의 설계보다는 이중 압축식의 설계를 행하는 것이 바람직하며 감도가 큰 가속도계 일수록 0.1g 이하의 낮은 가진 레벨에서의 특성도 아주 좋다. (3) 높은 주파수에서의 특성이 좋은 가속도계를 설계하기 위하여서는 단일 압축식 으로 설계하는 것이 좋으며 압전 소자의 두께는 얇은 것이 좋다. (4) 압전 소자와 관성 질량의 접착시에 전도성 접착제를 사용하지 않아도 기포를 제거한 양호한 에폭시계통의 접착제를 사용 하여 접착층의 두께를 최대한 얇게 하면 설계값에 가까운 감도를 가진 가속도계를 제작할 수가 있다.

  • PDF

Continuous Xanthan Fermentations in a Three-Phase Fluidized Bed Bioreactor (삼상유동층 생물반응기에서의 연속식 Xanthan 발효)

  • 서일순;노희찬;허충회
    • KSBB Journal
    • /
    • v.17 no.1
    • /
    • pp.26-32
    • /
    • 2002
  • The aerobic bacterium Xanthomonas campestris was cultivated continuously in a three-phase fluidized bed bioreactor to produce extracellular polysaccharide xanthan, Fluidized particles of 8.0 mm glass beads were used for disintegrating the large air bubbles even at high viscosities to improve the gas-liquid oxygen transfer rate. Xanthin productivity [kg xanthan/kg cell dry mass·h] and molecular weight increased, with dilution rate in the continuous xanthan fermentations. The specific xanthan productivities were not limited by the oxygen transfer rate and were much higher in the continuous cultivations than those predicted by the results of the batch xanthan fermentations.

경량 난연성 성형체의 특성에 관한 연구

  • 강영구;강정식;조명호
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1999.06a
    • /
    • pp.265-268
    • /
    • 1999
  • 경량 건축소재는 협소공간의 고도 이용과 건설 분야의 양적, 질적인 측면에서 급속한 성장으로 건축자재의 경량화, 고급화 및 다양화를 요구하고 있으며 이에 PE, PP, PS, PVC 등의 플리스틱 foam 및 저밀도 콘크리트 등의 경량 건축 소재에 대한 연구가 지속되고 있다. 경량 건축소재로 사용되는 플라스틱류는 대부분 난연화 및 강도유지를 위해 난연제, 섬유 및 무기충진제 등를 첨가하거나 고밀도화하여 사용하며 경량화를 위해 foaming agent를 사용하여 기포를 발생시켜 경량화하여 성형된다. (중략)

  • PDF

Effect of Chemical Conditioning on Flotation and Thickening Properties of Sludge using a Microbubble Generating Pump (화학적 개량이 미세기포 발생펌프를 이용한 슬러지 부상농축에 미치는 영향)

  • Lee, Chang-Han;Ahn, Kab-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.8
    • /
    • pp.641-648
    • /
    • 2009
  • The study presents sewage sludge flotation and thickening efficiencies which changes chemical conditioning and mixing conditions using a flotation thickening system with a microbubble generating pump. Flotation and thickening of sewage sludge are shown to significantly influence kinds of coagulants more than Gt values. It is found that the flotation and thickening efficiencies for kinds of coagulants follows the order: $Al_2(SO_4)_3$ < PSO-M < $Fe_2(SO_4)_3$. We shows that the flotation thickening system(1.6 $m^3$/d) could be continuously operated during two hours on operation conditions in the lab-scale experiments. Sludge thickening efficiency in the A/S ratio of 0.029 - 0.019 mL/mg was found to be very efficient, reaching to 300.0~335.7%.

CFD validation for subcooled boiling under low pressure (저압에서의 과냉각 비등 현상에 대한 CFD의 유효성 검토)

  • Choi, Yong-Seok;Kim, You-Taek;Lim, Tae-Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.275-281
    • /
    • 2016
  • Subcooled boiling under low pressure was numerically investigated using computational fluid dynamics(CFD). The wall boiling model was used for simulating the subcooled boiling; this model requires sub-models consisting of bubble departure diameter, nucleation site density and bubble departure frequency. The CFD code CFX provides the default models based on experimental data. Because these models are mostly developed under high pressure conditions, it would not be predicted well in low pressure conditions. Thus in this study, CFD validation for subcooled boiling under low pressure was analyzed. The numerical results were compared with experimental data from published paper. Simulations were performed with mass flux ranging from 250 to $750kg/m^2s$, heat flux ranging from 0.37 to $0.77MW/m^2$ and constant outlet pressure of 0.11 MPa. Employing the empirical correlation developed under low pressures could increase the accuracy of numerical analysis.

Feasibility Study the Assessment Factor of Quality Performance Index in Expressway Concrete Pavement (고속도로 콘크리트 포장에 대한 품질평가지수 평가인자의 적정성 검토)

  • Lee, Seung Woo;Kim, Gyung il;Ko, Dong Sig;Hong, Seung Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.133-141
    • /
    • 2017
  • Traffic volume increases according to highway expansion and industrial development which causes repetitive defect and durability degradation on pavement. The research of quality assurance system used abroad has introduced Korea. Korea Expressway Corporation (KEC) has developed a Quality Performance Index (QPI) that quantitatively assesses the level of quality of the final product, and practical applications. Assessment factor on concrete pavement consisted of pavement thickness, compressive strength, IRI and spacing factor. Assessment factor on concrete pavement is determined by empirical evaluation factor from abroad. In this study, analysis of evaluation factors of concrete pavement by using pavement life prediction simulation and measured data were evaluated with consideration of feasibility of the assessment factor. Pavement life, performance and durability are affected by pavement thickness, compressive strength, IRI and spacing factor in assessment factor on concrete pavement, QPI.

Analysis of Flow and Pressure Downstream of a Weir using Image Technique (영상기법을 활용한 보 하류의 흐름 및 압력특성 분석)

  • Ryu, Young-Uk;Park, Moonhyung;Kim, Hyung Suk;Choi, Seo Hye
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.511-511
    • /
    • 2017
  • 하천에서 홍수 예방 및 가뭄재해 방지를 목적으로 최근 4대강 살리기 사업이 수행되었다. 특히, 안정적인 용수공급 및 다양한 수재해 피해를 최소화하기위해 다기능보가 설치되었다. 설치된 보는 고정보와 가동보로 구분되며 평상시에는 고정보를 넘어가는 월류흐름이 발생하며 홍수 시에는 추가적으로 가동보를 개방하여 오리피스 흐름이 발생한다. 최근 기후변화로 인해 집중호우가 빈번히 발생하며 이는 보 주변에서 빠르고 복잡한 흐름을 유발하게 된다. 이러한 흐름특성은 보하류의 세굴문제뿐만 아니라 물받이와 바닥보호공의 안전성에 영향을 미칠 수 있다. 본 연구에서는 영상기법을 활용하여 도수가 발생하는 조건에서 고정보 하류의 물받이공 및 바닥보호공에 난류흐름특성 및 압력분포를 분석하였다. 길이 8.0 m, 폭 0.3 m를 갖는 개수로에서 실험을 수행하였으며 0.2 m 높이의 고정보는 상류경계로부터 3.0 m지점에 위치하였다. 보 하류부에서 유속성분은 비접촉식 유속측정 기법인 입자영상유속계(Particle Image velocimetry, PIV)와 기포흐름을 측정할 수 있는 기포영상유속계(Bubble Image velocimetry, BIV)를 적용하였다. 그러므로 기포 존재유무와 관계없이 보 하류부 구간에 대한 유속장 성분을 취득하였다. 도수흐름은 물받이공 및 바닥보호공 영역의 바닥면을 따라 빠른 유속을 갖는 제트류가 발생하고 수면과 바닥으로 강한 진동이 발생하여 불안정한 흐름이 야기된다. 바닥면에 작용하는 압력을 측정하기 위해 흐름방향을 따라 피에조미터를 설치하였고 압력수두 분포를 초고속카메라로 촬영하여 그 특성을 분석하였다. 실험을 결과를 통해 보 하류부에 영향을 미치는 인자를 도출하였으며 향후 보 설계기준에 반영할 수 있을 것으로 기대된다.

  • PDF

A Theoretical Analysis of the Weak Shock Waves Propagating through a Bubbly Flow (기액 이상류를 전파하는 약한 충격파에 관한 이론해석적 연구)

  • Jun, Gu-Sik;Baek, Seung-Cheol;Kim, Heuy-Dong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1617-1622
    • /
    • 2004
  • Two-phase flow of liquid and gas through pipe lines are frequently encountered in nuclear power plant or industrial facility. Pressure waves which can be generated by a valve operation or any other cause in pipe lines propagate through the two-phase flow, often leading to severe noise and vibration problems or fatigue failure of pipe line system. It is of practical importance to predict the propagation characteristics of the pressure waves for the safety design for the pipe line. In the present study, a theoretical analysis is performed to understand the propagation characteristics of a weak shock wave in a bubbly flow. A wave equation is developed using a small perturbation method to analyze the weak shock wave through a bubbly flow with comparably low void fractions. It is known that the elasticity of pipe and void fraction significantly affect the propagation speed of shock wave, but the frequency of relaxation oscillation which is generated behind the shock wave is not strongly influenced by the elasticity of pipe. The present analytical results are in close agreement with existing experimental data.

  • PDF

Approximate Probability Density for the Controlled Responses of Randomly Excited Saturated Oscillator (불규칙 가진을 받는 포화 진동계의 응답제어에 관한 확률밀도 추정)

  • 박지훈;김홍진;민경원
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.16 no.3
    • /
    • pp.301-309
    • /
    • 2003
  • The non linear control algorithm with actuator saturation for a randomly excited oscillator has been widely explored and has shown promising results, but the probabilistic analysis of the algorithm has been rarely made due to its non-linear nature and the fact that the analytical solution of probability density function (PDF) for controlled responses does not exist. In this paper, a method for the probabilistic analysis on the non linear control algorithm with actuator saturation is proposed based on the equivalent non linear system method. Numerical examples are given to verify the approximation solution of PDF comparing to a statistically obtained PDF using a Gaussian white noise and a Kanai - Tagimi filtered Gaussian white noise.