• Title/Summary/Keyword: 기초모형실험

Search Result 679, Processing Time 0.029 seconds

Assessment of Response Spectrum by Dynamic Centrifuge Test for the Pile Foundation into the Sand (동적 원심모형실험에 의한 사질토에 근입된 말뚝지지 기초의 응답 스펙트럼 분석)

  • Park, Yong-Boo;Park, Jong-Bae;Kim, Sang-Yeon;Kim, Dong-Soo
    • Land and Housing Review
    • /
    • v.5 no.1
    • /
    • pp.35-40
    • /
    • 2014
  • Site coefficient and amplification factor of current domestic Seismic Design Code (KBC-2009) have no consideration for the domestic ground condition in which the base rock is normally placed within 30m form the surface. Accordingly, in this study dynamic centrifugal test and analysis for pile foundation into sand and upper structure were achieved. and the response spectrums of free surface and basement were compared with each other. Within the period 1 sec., the measured spectral acceleration of free surface and basement was bigger than the design spectral acceleration of SC and SD site. However the measured spectral acceleration of free surface and basement for the period over 1.5 sec. was smaller than the design spectral acceleration of SC site. There was no severe difference of spectral acceleration according to the upper structure, embedded depth of foundation and free surface conditions. Consequently, normal domestic apartment housing for the period range over 1.5sec. could be design more economically applying these test result.

Hydraulic model experiment for infiltration in riverbank and its foundation (하부 투수층을 가지는 제방침투 수리모형실험)

  • Kim, Ji-Hyun;Lee, Nam-Joo;Yu, Kwon-Kyu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.654-658
    • /
    • 2012
  • 국내에서 수행한 대부분의 제방 침투에 대한 수리모형실험 연구는 제체만을 대상으로 수행되었으며, 투수성 기초지반을 고려한 연구는 찾아보기 어려운 상황이다. 이 연구에서는 개정된 제방설계기준에 따른 1:3의 비탈경사와 투수성 기초지반을 가지는 제방의 침투실험을 수행하였으며, 향후 제방침투 수치모의에 필요한 검보정 자료를 확보할 목적으로 수행하였다. 부산광역시 강서구에 위치한 낙동강 제2하구둑 건설 현장에서 제체의 재료를 채취여 입도분석과 들밀도시험을 통해 제방의 건조단위중량과 다짐도 및 제방의 투수계수는 각각 $1.372g/cm^3$, 93%, 1.35 m/day이며 통일분류법의 SM에 속하는 것으로 확인하였다. 0.45 m, 0.50 m, 0.55 m, 0.60 m의 4가지 수위(각각 Case-1~4) 조건에 대하여 정상상태에 도달할 때까지 실험을 계속한 결과 각각의 실험조건별 침윤선은 대체로 동일한 양상을 보였지만 몇 지점에서 위압수두계 수위의 이상점이 발견되었다. 제방을 해체하면서 원인을 찾아본 결과 머드볼이 형성되어 있음을 확인하였으며, 침투 흐름에 상당한 영향을 미쳤을 것으로 생각된다.

  • PDF

Development of a Traffic Simulation Program for Uninterrupted Traffic Flow Facilities (연속류 도로의 한국형 모의실험 프로그램 개발)

  • 최대순
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1997.04a
    • /
    • pp.45-60
    • /
    • 1997
  • 본연구의 목적은 1994년과 1995년의 연구 결과를 토대로 고속국도 교통류의 차량 추종, 차선 변경 특성을 현장 조사 자료를 통하여 분석·규명하고, 국내 고속도로의 교통류 특성을 반영할 수 있는 한국형 고속국도 모의실험 모형을 개발하는데 있다. 본 연구의 주요 결과는 다음과 같다. ▶ 국내 고속국도 교통류의 차두시간, 속도, 차량군의 크기, 차선 변 경, 중차량의 영향 등의 특성을 조사·분석하여 관련 매개변수와 모형식을 도출하였다. ▶ 차량 생성 모형은 개별 차량의 차두시간, 속도를 이용하여 구축하였으며, 중차량의 구성 비 율에 따른 속도 변화를 연구하여 그 결과를 모형 구축에 응용하였다. ▶ 차량 추종 모형은 1995년 연구에서 검증된 PITT-KLD 모형에 기반을 두었으며, 현장 실측 자료를 분석하여 차량 추종과 관련된 매개변수들을 설정하였다. ▶ 차선 변경 모형은 기본적으로 간격 수락 모형을 이용하였으며, 차선 변경시 임계 간격을 국내 운전자들의 유형에 따라 10가지로 설 정하였다. 차선 변경 확률은 현장 조사 자료를 기초로 한 경험적 모형을 구축하여 선정하였 으며, 마코프 연쇄 기법과도 비교·검토하였다. ▶ 개발된 모의실험 모형을 비교·평가하기 위 해 고속국도 합류부의 현장 조사 자료와 모의실험 모형을 비교·평가한 결과, 합류 이전 단 계에서는 실측치와 모형의 통계량이 어느 정도 유사한 양상을 보이지만 합류 이후 단계에서 는 차이를 나타내고 잇다.

  • PDF

Experimental Study on the Load Sharing Ratio of G개up Pile (무리말뚝의 하중분담률에 관한 실험적 연구)

  • Kwon Oh-Kyun;Oh Se-Bung;Kim Jin-Bok
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.5
    • /
    • pp.51-58
    • /
    • 2005
  • In this study, the large scale model tests were executed to estimate the Load Sharing Ratio (LSR) of raft in a piled footing under various conditions. The conditions such as the subsoil type, pile length, pile spacing, away type and pile installation method etc. were varied in the pile loading tests about the free-standing group piles and a piled footing. As a result of this study, it was found that there was no difference in the load-settlement curves, resulting from the pile installation method and subsoil type. The piles supported most of the external load until a yielding load of the piled footing, but the raft supported a considerable load after a yielding load. As the relative density of sands increased, the LSR decreased. As the pile spacing was wider and the pile length increased, there was a tendancy for the LSR to increase. But it was also found that the LSR was not affected by the pile installation method and the subsoil type.

Field Applicability Evaluation of Foundation Combine with Footing and Pile by Model Test (모형실험을 통한 복합기초의 현장 적용성 평가)

  • Kim, Hak-Moon;Jang, Kyung-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3729-3744
    • /
    • 2011
  • As the size of structures become larger by civil and architectural structures becoming large, deeply underground, and high-rise, the conditions of underground foundation vary according to the location that the lack of bearing capacity locally because of ununiform of foundation in some parts is frequent. Generally, when the foundation is not homogeneous, the acquisition of safety through applying the most conservative foundation method possible becomes the focus to secure the stability of the superstructures. It is considered as because of inability to verify the application and stability and application of construction of different foundations through an outlined review because of lack of study in case of different foundation of mixed use of direct foundation and pile foundation. Therefore, through measurement interpretation of the different foundation in which the direct foundation and pile foundation are mixed in use, the grounds in which the hypothetical bearing capacity changes dramatically was modeled to evaluate the applicability of different foundations. Also, based on the results of measurement interpretation, various foundations are created by using plaster, Joomunjin standard soil, and rubble to conduct an indoor model test to compare and analyze the movement of pile foundation and different foundations. Based on such research results, the stability and applicability of the different foundations which is more efficient and economical than the existing foundations in case of grounds in which the bearing capacity changes dramatically by comparing and analyzing the different foundations (direct foundation + pile foundation) with the conservative pile foundation and mat foundation. As a result, when the different foundation is applied, the overall settlement amount increased than the conservative pile foundation. However, the difference was very minute and it has been confirmed to be no issue as a result of assessment of stability of the differential settlement of structures through critical angle displacement.

The Stability of Strip Footing above Underground Cavity (지하공동에 인접한 연속기초의 안정성)

  • Oh, Se-Wook;Lee, Bong-Jik;Bae, Woo-Seok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.3
    • /
    • pp.69-76
    • /
    • 2006
  • In this study, an experimental study in sand ground that was prepared by raining method was performed for modeling the bearing capacity behavior of strip footing above a cavity. The critical range of bearing capacity of the strip footing affected by underground cavity was investigated by comparing results between experiment and theory. The size of the critical region depends on several factors such as footing shape, soil property, cavity size and cavity shape. The ultimate bearing capacity was more influenced by the depth of the underground cavity than the eccentricity of the underground. In addition, an underground cavity influences on not only the decrease of the bearing capacity, but also the differential settlement of a strip footing.

  • PDF

A fundamental study on drag force of shield TBM cutter bit by scaled model test (축소모형실험을 통한 쉴드 TBM 커터비트의 절삭력 평가를 위한 기초 연구)

  • Kim, Sang-Hwan;Jang, In-Suk;Kim, Ji-Tae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.3
    • /
    • pp.277-292
    • /
    • 2012
  • This paper presents the fundamental study on drag force of shield TBM cutter bit by scaled model test. Several theoretical analyses of the drag force of cutter bit have been studied. However, there are still some difference between the theoretical approaches and actual drag bit capacity. In order to study the drag forces of shield TBM cutter bit, the scaled model tests are carried out and analyzed. The results obtained from scaled model tests are compared with the existing theoretical equations. It is highly expected that the results of this study will be very essentially useful to design and develope the TBM cutterhead.

Shaking Table Tests of a 1/4-Scaled Steel Frame with Base Isolators (1/4축소 철골구조물을 이용한 건물 기초분리장치의 진동대실험)

  • 송영훈;김진구
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.2
    • /
    • pp.39-48
    • /
    • 1997
  • New form of base isolators made of steel spring coated with both natural and artficial rubber were manufactured and tested for material properties. Shaking table experiments were performed using a model structure attached with the bearings. The model structure used in the test is a 1/4 scaled steel structure, and earthquake records were used to check the lateral and vertical stability and effectiveness of the isolators. According to the results all three types of isolators turned out to be effective in reducing the acceleration induced by the earthquake vibration.

  • PDF

Failure Characteristics of Foundation System Reinforced with Stone Columns (쇄석말뚝으로 보강된 기초시스템의 파괴 거동)

  • Shin, Bang Woong;Bae, Woo Seok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.2 no.3
    • /
    • pp.71-80
    • /
    • 2001
  • The quantitative analysis of bearing capacity with stone column-mat is not ease because the bearing capacity of stone column is affected by so many parameters. The bearing capacity of stone column is mainly governed by horizontal resistance along the interface with soil. Also, this foundation system is affected by geometric factors such as column spacing, embedment ratio and failure surface inclination. Therefore, in this study, critical length and the effect of failure surface inclination was studied with single and group end bearing stone columns by loading tests. Results of model tests are compared to the present theoretical methods and are examined with FEM analysis.

  • PDF

Bearing Capacity of Shallow Foundation on Geogrid-Reinforced Clay (지오그리드로 보강된 점성토사의 얕은 기초의 지지력)

  • Shin, Bang Woong;Das, Braja M.;Shin, Eun Chul;Chung, Kee Taek
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.6
    • /
    • pp.1439-1444
    • /
    • 1994
  • Laboratory model test results for the ultimate bearing capacity and allowable bearing capacity at various settlement levels conducted on a strip foundation supported by geogrid-reinforced clay soil have been presented. For mobilization of the maximum possible load-carrying capacity, the optimum width and depth of the reinforcement layers, and the location of the first layer of reinforcement with respect to the bottom of the foundation have been determined.

  • PDF