• Title/Summary/Keyword: 기초공법

Search Result 704, Processing Time 0.021 seconds

Estimating of Optimal Allowed Distance for Reducing Vibration and Noise Problems by Pile Driving after Drilling Method in Deep Foundation Work (천공 후 말뚝타격공법의 진동 $\cdot$ 소음 문제 해소를 위한 적정 이격거리 산정 방안 연구)

  • Park Hong-Tae;Kang Lee-Seok
    • Korean Journal of Construction Engineering and Management
    • /
    • v.6 no.4 s.26
    • /
    • pp.152-163
    • /
    • 2005
  • Pile driving work causes a vibration problem in the construction site using pile foundation and often causes civil affairs by construction noise around the construction site. For the vibration and noise problems, the driving after drilling method rather than the direct driving method is being generalized for reducing vibration and noise. However, this method also causes civil affairs when the driving work is operated in adjacent area. This study suggests a criterion for evaluating an optimal allowed distance for pile driving work by the driving after drilling method. Actual surveys of vibration and noise for pile driving work in seven construction sites were used for developing regression analysis equations. The results can be a standard to estimate the allowed distance to avoid vibration and noise problems in pile driving work for deep foundation.

A Case Study on Explosive Demolition of a Industrial Plant Foundation (산업용 플랜트 기초의 발파해체 시공사례)

  • Noh, You-Song;Kim, Nae-Hoi;Jang, Seong-Ok;Suk, Chul-Gi;Park, Hoon
    • Explosives and Blasting
    • /
    • v.39 no.1
    • /
    • pp.22-35
    • /
    • 2021
  • The number of a industrial plant that must be demolished due to functional and structural deterioration has been increased. There is an increasing application of explosive demolition or explosive demolition combined with mechanical demolition to minimize temporal and spatial environmental hazardous factors created during the process of demolition. In this case study, to demolish the industrial plant foundation, which is a reinforced concrete structure, the explosive demolition technique was conducted. As a result of the explosive demolition, the overall crushing of plant foundation structure was satisfactory, and the explosive demolition was completed without causing any damage to surrounding facilities.

Development of a Height Adjustment Method of Prefabricated Individual Footing for the Leveling of Unit Modular Structural System (유닛모듈러 건축구조물의 수평 정밀도 확보를 위한 Pre-Fab 독립기초 높이조절 공법 개발)

  • Jun, Young-hun;Kim, Kyoon-Tai;Chae, Myung-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.6
    • /
    • pp.631-639
    • /
    • 2015
  • In the unit modular construction, the unit module prefabricated in a factory with a high level of accuracy does not fit completely onto the ground-joint junction due to the low accuracy of the ground work. This difference in the level of accuracy can cause diverse problems, such as twisting the upper unit modules and loosening the connection between the module and the footing. On this background, the aim of this study is to develop a technique for adjusting the height of the prefabricated individual footing. To accomplish the aim, a height adjustment method using bolts and nuts is proposed, and a shop drawing and the construction sequence are also presented in this study. The structural safety is verified through a structure simulation. In the future, research will be conducted on a mock-up test of the height adjustment method developed in this study, and an analysis of economic feasibility will be performed in order to verify its constructability and usability.

Design and Construction of Cellular Foundation Mattress as Foundations of Building Structures (건축구조물 기초로서 셀룰러 기초 매트리스의 설계 및 시공)

  • Jeong Young Lee;Jong Gon Ko;Nguyen Ngoc Son;Jae Hak Park;Doo Kie Kim
    • Journal of the Korean Geosynthetics Society
    • /
    • v.22 no.1
    • /
    • pp.25-37
    • /
    • 2023
  • Cellular Foundation Mattress made of new materials such as high density polyethylene, are not currently use for the foundation of small and medium-sized buildings in Korea. Therefore, they need to be developed and verified based on domestic ground and field conditions. This study presents the basic design and construction method of Cellular Foundation Mattress. Since the foundation reinforcement effect of Cellular Foundation Mattress should be evaluated and verified for soft ground, a performance comparison evaluation was conducted using the Soilbag method, which is commonly used for the foundation of small and medium-sized buildings in Korea. After the mattress reinforcement, the settlement amount decreased by 38.4% compared to the original ground and the bearing capacity increased by 159%, confirming the same ground reinforcement effect and ground stability as the Soilbag method.

Studies on the Landscape Conservation Measures of the Radial Roadsides in Seoul Area (조경녹화사방(造景綠化砂防)에 관(關)한 연구(硏究))

  • Woo, Bo-Myeong
    • Journal of Korean Society of Forest Science
    • /
    • v.28 no.1
    • /
    • pp.67-96
    • /
    • 1975
  • The serious consequences of the roadside erosion and its impact on sedimentation and deterioration of roadside landscape continue to be documented in Koreas. An analysis on the landscape conservation treatments was made through the field survey for the 8 radial roadsides around Seoul area. This was performed to identify and evaluate the present restoration measures, and to establish the practical standard measures for the landscape conservation treatments on the cut-and banking roadside slopes.

  • PDF

콘크리트 구조물의 해체공법에 대한 연구동향

  • 민윤기;유승규
    • Computational Structural Engineering
    • /
    • v.2 no.3
    • /
    • pp.37-39
    • /
    • 1989
  • 본 고에서는 선진 각국의 해체공법에 대한 연구동향을 고찰하기 위한 일환으로 1988.11.7-11 일본 동경에서 개최된 콘크리트와 조적조의 해체 또는 폐재의 재이용에 관한 제2회 심포지움에서 발표된 논문을 기초로 해체공법에 관한 연구동향을 살피고자 한다. 해체공법에 대하여 발표된 논문을 주제별로 살펴보았다.

  • PDF

Shaking Table Tests for Evaluation of Seismic Performance of Quay Walls (안벽 구조물의 내진성 평가를 위한 진동대 시험)

  • 김성렬;박영호;권오순;김명모
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.5
    • /
    • pp.75-81
    • /
    • 2000
  • 본 연구에서는 진동대 시험을 실시하여 지진동에 대한 일반 안벽 구조물과 내진 보강된 안벽 구조물의 동적거동을 분석하고 내진보강기법의 성능을 평가하였다. 진동대 시험은 기초지반이 조밀한 경우와 느슨한 경우, 자갈 뒤채움재를 설치한 경우 그리고 내진대책공법으로 경량재 치환공법과 모래다짐말뚝 공법을 적용한 경우 등 총 5가지 시험단면에 대하여 실시하였다. 과잉간극수압, 가속도 반응 그리고 지반의 변형양상을 분석한 결과, 기초지반과 뒤채움 지반의 연약화가 안벽 구조물의 동적거동에 큰 영향을 미치며, 경량재 치환공법과 모래다짐말뚝공법이 안벽 구조물의 내진성능을 향상시키는에 효과적인 것으로 나타났다.

  • PDF

Basic Study for Development of NATM Composite Lining Method (NATM Composite 라이닝 공법 개발을 위한 기초 연구)

  • Ma, Sang-Joon;Kang, Eun-Gu;Kim, Dong-Min;Shin, Joo-Yul
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.12
    • /
    • pp.53-68
    • /
    • 2011
  • This paper presents the fundamental parameters for designing the NATM Composite Lining to be used in NATM tunnel construction. Firstly, the concept of NATM Composite Lining behaviour is introduced and reviewed in construction-performance. For the fundamental study, the optimal mix ratio tests and backfill material property tests to develop high-quality composite lining (PC panel lining) are fundamentally carried out. And the light-weight foamed mortar which is used for backfill material is developed. Full-scale loading tests to verify a performance of the NATM Composite Lining is also performed. From this research, it is clearly found that the NATM Composite Lining is very applicable method to considerably increase the stability and constructability of tunnel structure.