• Title/Summary/Keyword: 기체 유량

Search Result 301, Processing Time 0.022 seconds

An experimental study on the characteristics of spray pattern by the Airblast Atomizer (공기충돌형 연료분사장치의 분무특성에 관한 실험적 연구)

  • Kim, Hyun-Joong;Han, Jae-Seob;Kim, Yoo;Min, Seong-Ki
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.2 no.2
    • /
    • pp.24-29
    • /
    • 1998
  • An experimental study was carried out to investigate the characteristics of spray pattern such as discharge coefficient, spray angle, and mass distribution for two-fluid airblast swirl injector, within the range of fluid supply pressure 0~13kg/$\textrm{cm}^2$. In general atomization is promoted with increasing total gas mass flow and performance of the splay pattern was more stable when radial mass flow was greater than axial mass flow, radial swirler was better than Axial swirler for atomization. Equivalent spray angle did not change with water mass flow except for the condition of 3kg/$\textrm{cm}^2$ and showed the same for the gas mass flow. Mass distribution from the patternator shows that maximum value of the distribution were lowered but distributed larger area when gas flow rate increased. Center of mass position did not change with increasing water mass flow.

  • PDF

Flow Rate Control Characteristics of a Cavitating Venturi in a Liquid Rocket Propellant Feed System (액체로켓 추진제 공급계에서 캐비테이션 벤튜리의 유량 제어 특성)

  • Cho, Won-Kook;Moon, Yoon-Wan;Kwon, Oh-Sung;Cho, In-Hyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.6
    • /
    • pp.46-52
    • /
    • 2002
  • Characteristics of flow rate control has been studied for a cavitating venturi adopted in a liquid rocket propellant feed system. Both experiment and numerical simulation have been performed to give about 10% discrepancy of mass flow rate for cavitating flow regime. Mass flow rate is confirmed to be saturated for pressure difference higher than $3{\times}10^5$pa when the upstream pressure is fixed to $22.8{\times}10^5$pa and the downstream pressure is varied. The evaporation amount depends substantially to non-condensable gas concentration. However the mass flow rate characteristics is relatively insensitive to the mass fraction of non-condensable gas. So it reduces by only 2% when the non-condensable gas concentration is increased from 1.5PPM to 150PPM. From the previous comparison the expansion of the non-condensable gas and the evaporation of liquid are verified to gave same effect to the pressure recovery pattern.

Analytical Methods of Leakage Rate Estimation from a Containment tinder a LOCA (냉각수상실 사고시 격납용기로부터 누출되는 유체유량 추산을 위한 해석적 방법)

  • Moon-Hyun Chun
    • Nuclear Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.121-129
    • /
    • 1981
  • Three most outstanding maximum flow rate formulas are identified from many existing models. Outlines of the three limiting mass flow rate models are given along with computational procedures to estimate approximate amount of fission products released from a containment to environment for a given characteristic hole size for containment-isolation failure and containment pressure and temperature under a loss of coolant accident. Sample calculations are performed using the critical ideal gas flow rate model and the Moody's graphs for the maximum two-phase flow rates, and the results are compared with the values obtained from the mass leakage rate formula of CONTEMPT-LT code for converging nozzle and sonic flow. It is shown that the critical ideal gas flow rate formula gives almost comparable results as one can obtain from the Moody's model. It is also found that a more conservative approach to estimate leakage rate from a containment under a LOCA is to use the maximum ideal gas flow rate equation rather than tile mass leakage rate formula of CONTEMPT-LT.

  • PDF

Characteristics of Plasma Discharge according to the Gas-flow Rate in the Atmospheric Plasma Jets (대기압 플라즈마 제트의 기체 유량에 대한 방전 특성)

  • Lee, Won Young;Jin, Dong Jun;Kim, Yun Jung;Han, Gook Hee;Yu, Hong Keun;Kim, Hyun Chul;Jin, Se Whan;Koo, Je Huan;Kim, Do Young;Cho, Guangsup
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.3
    • /
    • pp.111-118
    • /
    • 2013
  • The influence of gas flow on the plasma generation in the atmospheric plasma jet is described with the theory of hydrodynamics. The plasma discharge is affected by the gas-flow streams with Reynolds number (Re) as well as the gas pressure with Bernoulli's theorem according to the gas flow rate inserted into the glass tube. The length of plasma column is varied with the flow types such as the laminar flow of Re<2,000 and the turbulent flow of Re>4,000 as it has been known in a general fluid experiments. In the laminar flow, the plasma column length is increased as the increase of flow rate. Since the pressure in the glass tube becomes low as the increase of flow velocity by the Bernoulli's theorem, the breakdown voltage of plasma discharge is reduced by the Paschen's law. Therefore, the plasma length is increased as the increasing flow rate with the fixed operation voltage. In the transition of laminar and turbulent flows, the plasma length is decreased. When the flow becomes turbulent as the flow rate is increasing, the plasma length becomes short and the discharge is shut down ultimately. In the discharge of laminar flow, the diameter of plasma beam exposed on the substrate surface is kept less than the glass diameter, since the gas flow is kept to the distinct distance from the nozzle of glass tube.

Experimental Study on the Extinguishing Characteristics of Twin-fluid Nozzle using a Small-scale Hexane Pool Fire (소규모 헥산 풀화재를 이용한 2유체노즐의 소화 특성에 대한 실험적 연구)

  • Jeong, Chan Seok;Lee, Chi Young
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.35-41
    • /
    • 2018
  • Experiments were performed on 140 ml hexane pool fire extinguishment using a twin-fluid nozzle. For this pool fire, the area of the fire source (round shape of 80 mm in diameter) was $0.005027m^2$ and the measured heat release rate was 2.81 kW. The flow rates of water and gas (air and nitrogen) supplied to the twin-fluid nozzle were 156-483 g/min (~0.156-0.483 l/min) and 30-70 l/min, respectively. In the present experimental ranges, the high gas flow rate conditions led to the successful extinguishing of the pool fire. Under the low gas flow rate conditions in the extinguishment regime, the extinguishment time was long and the estimated water consumption was high. Under high gas flow rate conditions, however, the water flow rate conditions did not appear to have a great impact on the extinguishment time and estimated water consumption. On the other hand, in the present experimental ranges, the types of supply gas did not appear to affect the extinguishable flow rate condition, extinguishment time, and estimated water consumption. Finally, using the present experimental results with previous ones using a single-fluid nozzle, the water consumption of twin-fluid and single-fluid nozzles for extinguishing a 140 ml hexane pool fire were preliminarily compared and discussed.

Room Temperature Fabrication of Silicon Oxide Thin Films by ECR PECVD (ECR PECVD 에 의한 상온 실리콘 산화막 형성)

  • 이호영;전유찬;주승기
    • Journal of the Korean Vacuum Society
    • /
    • v.2 no.4
    • /
    • pp.462-467
    • /
    • 1993
  • ECR PECVD(Electron Cyclotron Resonance Plasma Enhanced Chemical Vapor Deposition )장치를 이용하여 (100) 실리콘 기판 위에 실리콘 산화막을 상온에서 증착하였다. 기체 유량비(SiH4/O2)가 막의 성질에 미치는 영향을 고찰하여 최적의 증착 조건을 도출하였다. 기체 유량비가 0.071일 때 비가역 파괴 전장은 9~10MV/cm 이었고, 4~5MV/cmm의 전장하에서 누설 전류는 ~10-11 A/$ extrm{cm}^2$이었다. 이러한 수치들은 액정 표시 소자용 박막 트랜지스터와 같이 저온의 제조공정이 요구되는 소자를 만들기에 충분하다.

  • PDF

Development of system for flow meter performance automatic revision by auto tuning membership function (멤버쉽함수 조정에 의한 유량계 성능 자동보정 시스템 개발)

  • 이오걸;이실환
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2002.12a
    • /
    • pp.149-152
    • /
    • 2002
  • 본 연구에서는 밸브의 입출력 류량 검출 센싱 장치 및 류량 성능 특성 곡선을 측정하는 소프트웨어를 개발하였다. 본 개발품은 기체 또는 액체의 양을 조절하는 밸브의 정밀한 제품을 생산할 수 있는 시스템이다. 멤버쉽함수의 최적한 폭을 자기동조에 의해 선정할 수 있었으며, 이를 이용하여 밸브의 압력 제어 성능을 보다 정밀하게 보정 할 수 있었다. 기체 또는 액체의 유량을 조절하는 감압 자동 조절밸브의 성능을 온라인으로 시험 할 수 있는 소프트웨어를 국산화하였다. 본 제품의 개발 결과 우수한 성능을 가진 감압 밸브 성능자동 보정 시험 검사용 소프트웨어임을 확인하였다.

Development of PSA Process for Medical Oxygen Generator (의료용 산소발생기 제작을 위한 PSA 공정의 개발)

  • Choi, Jae-Wook;Na, Byung-Ki
    • Clean Technology
    • /
    • v.15 no.2
    • /
    • pp.75-80
    • /
    • 2009
  • In order to separate oxygen from air, the effects of feed gas flow rate and rinse gas flow rate on the product purity and flow were examined using 2 bed PSA with 4 step cycle. The addition of product pressurization step increased the product purity and flow rate. The addition of pressure equalization increased the product flow rate. The test product was manufactured and the purity and flow rate of product oxygen was examined. The results were compared with the commercial medical oxygen generator of 5 ${\ell}/min$ and 90% oxygen purity.

Effect of boron doping on the chemical and physical properties of hydrogenated amorphous silicon carbide thin films prepared by PECVD (플라즈마 화학증착법으로 제조된 수소화된 비정질 탄화실리콘 박막의 물성에 대한 붕소의 도핑효과)

  • 김현철;이재신
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.1
    • /
    • pp.104-111
    • /
    • 2001
  • B-doped hydrogenated amorphous silicon carbide (a-SiC:H) thin films were prepared by plasma-enhanced chemical-vapor deposition in a gas mixture of $SiH_4, CH_4,\;and\; B_2H_6$. Physical and chemical properties of a-SiC:H films grown with varing the ratio of $B_2H_6/(SiH_4+CH_4)$ were characterized with various analysis methods including scanning electron microscopy (SEM), X-ray diffractometry (XRD), Raman spectroscopy, Fourier-transform infrared (FTIR) spectroscopy, secondary ion mass spectroscopy (SIMS), UV absorption CH_4spectroscopy and electrical conductivity measurements. With the B-doping concentration, the doping efficiency and the micro-crystallinity were decreased and the film became amorphous when $B_2H_6/(SiH_4{plus}CH_4)$ was over $5{\times}10^{-3}$. The addition of $B_2H_6$ gas during deposition decreased the H content in the film by lowering the quantity of Si-C-H bonds. Consequently, the optical band gap and the activation energy of a-SiC:H films were decreased with increasing the B-doping level.

  • PDF