Standard Neutron Irradiation Facility for Calibration of Radiation Protection Instruments by Radioactive Neutron Sources (방사성 중성자선원에 의한 방사선방어측정기의 교정을 위한 표준 중성자 조사장치 연구)

  • Choi, Kil-Oung;Lee, Kyung-Ju;Hwang, Sun-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.1
    • /
    • pp.66-70
    • /
    • 1989
  • In routine testing, the radioactive neutron sources are particularly suitable for producing standard. neutron fields. The ISO TC-85 has proposed neutron reference radiation for the calibration of neutron measuring devices used for radiation protection purposes. Radiation laboratory of KSRI has installed a standard irradiation facility using $^{252}Cf$ and $^{241}Am-Be$ sources for calibrating personal dosimeters according to the recommendations given in ISO TC-85. In this study, correction factors for calibration related to neutron scattering and anisotropy are obtained by experiments with commercial rem meter for demonstration purposes.

  • PDF

옥수수 전분 추출공정 및 물성개선을 위한 방사선의 이용연구

  • 강일준;이수정
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 1994.07a
    • /
    • pp.15-16
    • /
    • 1994
  • 옥수수 전분의 추출공정 개선 연구의 일환으로 메 밀 찰옥수수에 0-10 kGy범위의 감마선을 조사한 후 전분 추출시험과 추출전분의 이화학적 특성을 펴가하였다. 적정선량 범위의 감마선조사는 전분추출을 위한 침지시간을 기존 50시간에서 40시간으로 단축 시킬 수 있었으며, 환경기준 물질인 옥수수침지액(아황산용액)의 농도를 기존 0.8-1.2% 에서 0.2%로 크게 감소시킬 수 있었다. 또한 옥수수전분 추출액에 있어서 감마선 조사된 메옥수수와 찰옥수수는 비조사군에 비해 10-30% 이상의 추출율 증대효과를 나타내었다. 추 전분의 이화학적 특성시험에있어서는 두 시료 모두 감마선조사에 의해 alkaili number와 광투과도가 크게 증가 하였으며, 물 결합능력 및 swelling power는 다소 감소하는 경향이었다.전분의 색도는 조사군과 비조사군 사이에 유의적인 차이가 없었다. 효소반응 시험에서는 감마선 조사량이 증가함에 따라 효소반응 생성물인 포도당과 환원당 함량이 크게 증가하였다. Amylograph에 의한 물성시험에서는 감마선조사에 의해 전분호화액의 점도는 감소되었고, 그 경향은 메옥수수보다 찰옥수수에서 더욱 현저하였다. 또한 감마선의 이용은 옥수수 전분의 breakdown ratio 및 setback ratio를 향상시킬 수 있어 식품가공에서 전분의 고존도 사입 가능성을 시사하였다. 시사하였다.

  • PDF

Determination of Derived Release Limits for a CANDU Nuclear Power Plant (CANDU형 원전에서의 유도방출한도 결정)

  • Kim, Kyo-Youn;Hwang, Hae-Ryong;Kim, Jong-Kyung
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.1
    • /
    • pp.23-35
    • /
    • 1994
  • A computer code DRL was developed to calculate the derived release limits at CANDU type nuclear power plants. The derived release limits resulting from DRL code is to set guidelines for the release of radionuclides in airborne and water-borne effuents during normal operations of a CANDU type nuclear power plant. The DRL code generally follows the methodology Prescribed in the CSA standard N288.1-M87 and uses the Parameter values recommended in the same standards. The DRL code was used to calculate a set of preliminary derived release limits for the Wolsong NPP.

  • PDF

방사선치료빔 실시간 측정장치 개발

  • Kim, Jae-Hong;Swanepoe, M.W.;deKock, E.A.;Park, Yeon-Su;Yang, Tae-Geon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.288-288
    • /
    • 2010
  • 현대사회의 급속한 고령화로 암 환자의 수는 2002년 기준 약 10만 명에서 매년 7~10 %씩 증가되어 2012년에는 20만 명이 될 것으로 추정되어지고 있다. 수술, 방사선 치료, 약물요법 등이 주요 치료방법이며, 암 환자의 30-50 %가 전리 방사선치료를 받고 있다. 방사선치료는 19세기 말에 발견된 미지의 X-선이 희망의 방사선으로 변화하여 암의 진단 및 치료에 활용되고 있으며, 인간 삶의 질 향상에 핵심적인 역할을 담당하고 있다. 기존의 X-선이나 감마선의 단점을 극복 할 수 있는 입자 빔을 1970년대 미국의 캘리포니아 대학 Berkely National Laboratory에서 처음으로 암 치료에 적용하였다. 현재는 일본과 독일에서 활발하게 활용되고 있으며 국내에서도 입자 치료시설을 구축 또는 개발계획 중에 있다. 방사선치료의 완치율을 높이기 위해서는 정확한 선량을 암세포에 전달해야 한다. 환자에 전달되는 입자빔을 실시간으로 측정하는 기술이 연구되어지고 있다. 지금까지는 빔의 특성을 측정하기 위해 간섭적인 방법을 사용하였으나, 투과형 검출기를 개발하여 실시간으로 치료와 빔 특성을 동시에 수행하는 기술개발연구가 보고되고 있다. 본 연구에서는 Multileaf Faraday Cup (MLPC) 검출기 설계구조와 데이터 측정방법에 관한 연구를 수행하고자 한다. 빔의 전송 방향으로 3개층의 $4{\times}4$ 배열의 구조로 48 channel의 전류값을 측정하여 입자빔의 분포를 실시간으로 관측하고, 측정된 전류는 ADC를 거쳐 치료계획에 의해 선택된 영역의 SOBP를 유지하도록 range modulation propeller를 조절하는 feed-back system을 갖춘 방사선치료빔 실시간 측정장치 개발에 관한 결과를 보고하고자 한다.

  • PDF

Study of the seroma volume changes in the patients who underwent Accelerated Partial Breast Irradiation (부분유방방사선치료(Accelerated Partial Breast Irradiation) 환자의 장액종(Seroma) 체적 변화에 대한 연구)

  • Kim, Dae Ho;Son, Sang Jun;Mun, Jun Ki;Seo, Seok Jin;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.65-75
    • /
    • 2016
  • Purpose : By analyzing seroma volume changes in the patients who underwent Partial breast radiation therapy after breast conserving surgery, we try to contribute to the improvement of radiotherapy effect. Materials and Methods : Enrolled 20 patients who underwent partial breast radiation therapy by ViewRay MRIdian System were subject. After seeking for the size of the removed sample in the patients during surgery and obtained seroma volume changes on a weekly basis. On the Basis of acquired volume, it was compared with age, term from start of the first treatment after surgery, BMI (body mass index) and the extracted sample size during surgery. And using the ViewRay MRIdian RTP System, the figure was analyzed by PTV(=seroma volume + margin) to obtain a specific volume of the Partial breast radiation therapy. Results : The changes of seroma volume from MR simulation to the first treatment (a week) is 0~5% in 8, 5~10% in 3, 10 to 15% in 2, and 20% or more in 5 people. Two patients(A, B patient) among subjects showed the biggest change. The A patient's 100% of the prescribed dose volume is 213.08 cc, PTV is 181.93 cc, seroma volume is 15.3 cc in initial plan. However, while seroma volume decreased 65.36% to 5.3 cc, 100% of the prescribed dose volume was reduced to 3.4% to 102.43 cc and PTV also did 43.6% to 102.54 cc. In the case of the B patient, seroma volume decreased 42.57% from 20.2 cc to 11.6 cc. Because of that, 100% of the prescribed dose volume decreased 8.1% and PTV also did to 40%. Conclusion : As the period between the first therapy and surgery is shorter, the patient is elder and the size of sample is smaller than 100 cc, the change grow bigger. It is desirable to establish an adaptive plan according to each patient's changes of seroma volume through continuous observation. Because partial breast patients is more sensitive than WBRT patients about dose conformity in accordance with the volume change.

  • PDF

Quality Assurance of Volumetric Modulated Arc Therapy for Elekta Synergy (Elekta Synergy 선형가속기를 이용한 입체적세기조절회전방사선치료(VMAT) 정도관리)

  • Shim, Su-Jung;Shim, Jang-Bo;Lee, Sang-Hoon;Min, Chul-Kee;Cho, Kwang-Hwan;Shin, Dong-Oh;Choi, Jin-Ho;Park, Sung-Ill;Cho, Sam-Ju
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.33-41
    • /
    • 2012
  • For applying the quality assurance (QA) of volumetric modulated arc therapy (VMAT) introduced in Eulji Hospital, we classify it into three different QA steps, treatment planning QA, pretreatment delivering QA, and treatment verifying QA. These steps are based on the existing intensity modulated radiation therapy (IMRT) QA that is currently used in our hospital. In each QA step, the evaluated items that are from QA program are configured and documented. In this study, QA program is not only applied to actual patient treatment, but also evaluated to establish a reference of clinical acceptance in pretreatment delivering QA. As a result, the confidence limits (CLs) in the measurements for the high-dose and low-dose regions are similar to the conventional IMRT level, and the clinical acceptance references in our hospital are determined to be 3 to 5% for the high-dose and the low-dose regions, respectively. Due to the characteristics of VMAT, evaluation of the intensity map was carried out using an ArcCheck device that was able to measure the intensity map in all directions, $360^{\circ}$. With a couple of dosimetric devices, the gamma index was evaluated and analyzed. The results were similar to the result of individual intensity maps in IMRT. Mapcheck, which is a 2-dimensional (2D) array device, was used to display the isodose distributions and gave very excellent local CL results. Thus, in our hospital, the acceptance references used in practical clinical application for the intensity maps of $360^{\circ}$ directions and the coronal isodose distributions were determined to be 93% and 95%, respectively. To reduce arbitrary uncertainties and system errors, we had to evaluate the local CLs by using a phantom and to cooperate with multiple organizations to participate in this evaluation. In addition, we had to evaluate the local CLs by dividing them into different sections about the patient treatment points in practical clinics.

Usefulness of Non-Invasive Measurement Tool on Performance Evaluation of Inverter Type X-ray Unit (인버터식 X선장치의 성능평가 시 비접속형 측정기의 유용성)

  • Kang, Se-Sik;Kim, Chang-Soo;Ko, Sung-Jin
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.123-127
    • /
    • 2008
  • Purpose: As the demand of a simple and precise method increases to evaluate the performance of the inverter type x-ray unit, we evaluated the usefulness of the recently-introduced X-ray Multi-Function Test Device (moldel : Xi (unfors)-prestige). Method: We compared the performance of X-ray Multi-Function Test Device (XMFTD) which is non-inveasive type device with the performance of Dynalyzer III that has been most widely used inveasive type measure device. Result: X-ray output dose was increased a little in the XMFTD, but both devices were below the performance evaluation standard, 0.002 in the output reproducibility. Linearity of XMFTD were below 0.1 which means that Dynalyzer III showed more excellency in linearity. As the the accuracy of exposure factor, 1.8 and 2 tube voltage, 2.01 and 2.3 tube current were measured. The exposure time was also measured by 0.01 sec ${\pm}10%$. Both devices were within the acceptance of performance evaluatioin standard. Conclusion: We proved the usefulness of X-ray Multi-Function Test Device (model: Xi (unfors)-prestige) to evaluated the performance on reproductibility and linearity of X-ray output and accuracy of exposure factor of inverter type unit.

  • PDF

Study on the Jurisdiction of the National Technical Qualification (국가기술자격 관할영역에 관한 연구)

  • Park, Jong-Sung;Kim, Hyun-Soo;Kim, Deog-Ki;Lee, Young-Ran
    • Journal of Engineering Education Research
    • /
    • v.12 no.2
    • /
    • pp.24-35
    • /
    • 2009
  • This study was conducted to establish a principle on the fields of National Technical Qualification(NTQ), and aimed at developing criteria on requirements of the qualification that will be managed as the national technical qualification. In order to achieve the objective of the study, we examined the directions of setting the Jurisdiction of national technical qualification through role assignment between the state and private sectors. Also, we reviewed related documents, conducted Delphi survey, consulted the expert group and had an interview session for this study. There are five criteria of the jurisdiction of NTQ presented as follows. First is the field which disturbs social orders or has possibility of harming the good public morals; second, the field that requires high standards of ethics or is directly linked to life, health and safety of the public; third, the field which requires national attention for training of manpower as it is an area that is difficult for private sector to approach or it requires national management; fourth, the field which requires repair or maintenance of resources of traditional culture but is difficult for the private sector to have an access to and fifth, the field where it needs to protect the interest of the nation in the inter-nation relationships. The concrete and detailed standard on the five criteria is also presented in the study.

Evaluation of the reconstruction of image acquired from CT simulator to reduce metal artifact (Metal artifact 감소를 위한 CT simulator 영상 재구성의 유용성 평가)

  • Choi, Ji Hun;Park, Jin Hong;Choi, Byung Don;Won, Hui Su;Chang, Nam Jun;Goo, Jang Hyun;Hong, Joo Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.191-197
    • /
    • 2014
  • Purpose : This study presents the usefulness assessment of metal artifact reduction for orthopedic implants(O-MAR) to decrease metal artifacts from materials with high density when acquired CT images. Materials and Methods : By CT simulator, original CT images were acquired from Gammex and Rando phantom and those phantoms inserted with high density materials were scanned for other CT images with metal artifacts and then O-MAR was applied to those images, respectively. To evaluate CT images using Gammex phantom, 5 regions of interest(ROIs) were placed at 5 organs and 3 ROIs were set up at points affected by artifacts. The averages of standard deviation(SD) and CT numbers were compared with a plan using original image. For assessment of variations in dose of tissue around materials with high density, the volume of a cylindrical shape was designed at 3 places in images acquired from Rando phantom by Eclipse. With 6 MV, 7-fields, $15{\time}15cm2$ and 100 cGy per fraction, treatment planning was created and the mean dose were compared with a plan using original image. Results : In the test with the Gammex phantom, CT numbers had a few difference at established points and especially 3 points affected by artifacts had most of the same figures. In the case of O-MAR image, the more reduction in SD appeared at all of 8 points than non O-MAR image. In the test using the Rando Phantom, the variations in dose of tissue around high density materials had a few difference between original CT image and CT image with O-MAR. Conclusion : The CT images using O-MAR were acquired clearly at the boundary of tissue around high density materials and applying O-MAR was useful for correcting CT numbers.

Hospice and Palliative Care for the Terminal Patients with Colorectal Cancer (말기 대장직장암 환자의 호스피스 완화의료)

  • Hong, Young-Hwa;Lee, Choon-Sub;Lee, Ju-Ri;Lee, Jung-Ho;Kim, You-Jin;Lee, Tae-Kgyu;Moon, Do-Ho
    • Journal of Hospice and Palliative Care
    • /
    • v.10 no.1
    • /
    • pp.35-42
    • /
    • 2007
  • Purpose: Colorectal ranter is the 4th leading cause of cancer death in Korea and the prevalence is increasing continuously. This study was aimed to figure out the problems through the clinical consideration about terminal colorectal ranter patients who had died in hospice unit. Methods: We retrospectively reviewed the medical records in 78 patients with colorectal ranter who had admitted, received palliative care, and died in a hospice unit between April 2003 and November 2006. Results: The median age of patients was 59.6 years with 45 men (58%) and 24 women (42%). The median survival in hospice and palliative care was 36 days. The median hospitalization was 22 days. The most prevalent reason for admission was pain (38 patients, 49%), and the most common symptom was also pain (70 patients, 90%). Forty eight patients (62%) took analgesics before hospice referral. Twenty seven patients (65%) of 45 patients with intestinal obstruction have been performed palliative procedures. Median survival of patients with palliative procedure was higher than that of no palliative procedure group (47 days vs 19 days, P-value=0.005). Conclusion: The duration of hospice and palliative care was not enough to care the terminal colorectal cancer. Therefore, we suggest that proper education and information should be provided to physician, patients and their family members for effective hospice and palliative care.

  • PDF