• Title/Summary/Keyword: 기준공기

Search Result 757, Processing Time 0.031 seconds

A Study on the Estimation for the Guaranteed Strength and Construction Quality of the Combined High Flowing Concrete in Slurry Wall (지하연속벽용 병용계 고유동 콘크리트의 시공 품질 및 보증강도 평가에 관한 연구)

  • Kwon, Yeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.6 s.96
    • /
    • pp.811-817
    • /
    • 2006
  • The primary purpose of this study is to estimate the guaranteed strength and construction quality of the combined high flowing concrete which is used in the slurry wall of underground LNG storage tank. The required compressive strength of this type of concrete become generally known as a non economical value because it is applied the high addition factor for variation coefficients and low reduction factor under water concrete. Therefore, after estimation of the construction quality and guaranteed strength in actual site work, this study is to propose a suitable equation to calculate the required compressive strength in order to improve its difference. Application results in actual site work are shown as followings. The optimum nix design proportion is selected that has water-cement ratio 51%, sand-aggregate ratio 48.8%, and replacement ratio 42.6% of lime stone powder by cement weight. Test results of slump flow as construction quality give average 616~634mm. 500mm flowing time and air content are satisfied with specifications in the rage of 6.3 seconds and 4.0% respectively. Results of strength test by standard curing mold show that average compressive strength is 49.9MPa, standard deviation and variation coefficients are low as 1.66MPa and 3.36%. Also test results by cored cylinder show that average compressive strength is 66.4MPa, standard deviation and variation coefficients are low as 3.64MPa and 5.48%. The guaranteed strength ratio between standard curing mold and cored cylinder show 1.23 and 1.32 in the flanks. It is shown that applied addition factor for variation coefficients and reduction factor under water concrete to calculate the required compressive strength is proved very conservative. Therefore, based on these results, it is proposed new equation having variation coefficients 7%, addition factor 1.13 and reduction factor 0.98 under water connote.

Calculation of Derived Investigation Levels for Uranium Intake (우라늄 섭취의 유도조사준위 산출)

  • Lee, Na-Rae;Han, Seung-Jae;Cho, Kun-Woo;Jeong, Kyu-Hwan;Lee, Dong-Myung
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.2
    • /
    • pp.68-77
    • /
    • 2013
  • Derived Investigation levels(DILs) were calculated to protect the workers from the effects of both radiological hazard and chemical toxicity by uranium intake. Investigation Levels(ILs) of committed effective dose of 2 mSv $y^{-1}-6$ mSv $y^{-1}$ and uranium concentration of 0.3 ${\mu}g$ $g^{-1}$ in kidney, based on Korean Nuclaer Safety Act, Korean Occupational Safety and Health Act and current scientific studies of uranium intake were assumed. DILs of radiological hazard and chemical toxicity were then calculated based on the concentration of uranium in air of workplace, the lung monitoring and urine analysis, respectively. As a result, in case of the nuclear fuel fabrication plant where 3.5% enriched uranium is handled, derived investigation level(DIL) for the control of the concentration of uranium in the air of workplace assumed with 15-min acute inhalation was 0.6 mg $m^{-3}$ for all types of uranium. DILs for the control of the average concentration of uranium in air of workplace, assuming an 8-hour workday, were 15.21 ${\mu}g$ $m^{-3}$ of Type F uranium, 0.41-1.23 Bq $m^{-3}$ and 0.13-0.39 Bq $m^{-3}$ for Type M and Type S uranium, respectively. DILs for the lung monitoring assumed with a period of 6-month interval were 0.37-1.11 Bq and 0.39-1.17 Bq in acute and chronic inhalation for Type M, respectively and 0.30- 0.91 Bq and 0.19-0.57 Bq in acute and chronic inhalation for Type S, respectively. Since a detection limit of typical germanium detector for the measurement of 235U activity is 4 Bq, DILs calculated for the lung monitoring were not appropriate. DILs for urine analysis, for which an interval was assumed to be 1 month, were 14.57 ${\mu}g$ $L^{-1}$ based on chemical toxicity after acute inhalation. In addition, acute and chronic inhalation of Type M were calculated 2.85-8.58 ${\mu}g$ $L^{-1}$ and 1.09-3.27 ${\mu}g$ $L^{-1}$ based on the radiological hazard, respectively.

Effect of Microbial Flora and Inoculation of Probiotics on Fermenting Characteristics of Naked Barley Grain (Hordeum Vulgare L.) (쌀보리 종실 내 미생물 분포와 생균제 접종이 발효특성에 미치는 영향)

  • Ahn, Hye-Jin;Kim, Ki Hyun;Jo, Eun Seok;Kim, Jo Eun;Kim, Kwang-Sik;Kim, Young Hwa;Song, Tae Hwa;Park, Jong Ho;Kang, Hwan Ku;Jang, Sun Sik;Oh, Young Kyoon;Cheon, Dong Won;Seol, Kuk-Hwan
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.35 no.4
    • /
    • pp.321-326
    • /
    • 2015
  • This study was performed to analyze the resident microbial flora and the effects of probiotic inoculation on the fermentation characteristics of whole grain naked barley (Hordeum Vulgare L.) with the goal of evaluating the possibility of utilization as fermented feedstuff. Naked barley grains were harvested 35 days after heading, and the microbial flora was analyzed using MALDI-TOF mass spectrometer. After inoculation of commercial microbes to the naked barley grain (BT), the pH and number of bacteria, such as aerobic bacteria, lactic acid bacteria, yeast and E. coli, were measured and compared with the non-inoculated control (BC). A total of 122 colonies was isolated from the naked barley grain and the most popular bacteria species was Staphylococcus xylosus (n = 30, 24.59%). The pH value decreased more rapidly in BT than in BC, and was significantly lower after 7 days of fermentation at $4.33{\pm}0.02$ and $4.83{\pm}0.01$, respectively. The number of aerobic bacteria, lactic acid bacteria and yeast showed an increasing trend within the first 7 days of fermentation, however, their numbers decreased at 28 and 42 days of fermentation. The population of lactic acid bacteria in BT was higher than in BC, but there was no significant different at 7 days of fermentation, with respective levels of $9.24{\pm}0.20$ and $9.01{\pm}0.10logCFU/g$ (p>0.05). The initial number of E. coli was very high in the naked barley grain but subsequently decreased significantly. After 7 days of fermentation, E. coli was not detected in either BT or BC samples. From these results, it appears that the fermentation of naked barley grain proceeded adequately after 7 days, and that fermentation contributes to the safety of naked barley grain during storage.

Retrospective Investigation of Canine Skin and Mammary Tumors in Korea (한국에서 개 유선종양과 피부종양의 발생현황)

  • Kim, Yeong-Hun;Ahn, Na-Kyoung;Roh, In-Soon;Yoon, Byung-Il;Han, Jeong-Hee
    • Journal of Veterinary Clinics
    • /
    • v.26 no.6
    • /
    • pp.556-562
    • /
    • 2009
  • Skin tumors and mammary gland tumors have been shown to be the most common neoplasia in most of the strains of dogs. The risk for tumor development increases significantly with age and the prevalence and distribution are various according to individual tumors. The aim of this study is to classify histopathologically the skin and mammary gland tumors for recent two years, 2005 and 2006. A total of 128 skin and 240 mammary gland samples of dogs were selected that were submitted to National Veterinary Research and Quarantine Service and Kangwon National University from January 1, 2005 to December 31, 2006. The excised tissue were fixed in 10 percent neutral buffered formalin and processed routinely to paraffin wax. Sections were cut at $3{\mu}m$, stained with haematoxylin and eosin. The slides were examined based on the morphological criteria of M. H. Goldschmidt and W. Misdorp under a light microscope. The age of the dogs ranged from 1 to 19 years with a median of 8.7 years. The mean age of the skin and mammary gland tumors was 7.4 and 9.3 years. 47 (12.8%) were males and 259 (70.4%) were female with a male to female ratio of 0.18. Yorkshire terrier and maltese were more susceptible breeds, accounting for 44.3% of skin and mammary gland tumors. In skin tumors, epithelial, adnexal, and mesenchymal origin tumors were 18 (14.1%), 53 (41.4%), and 57 cases (44.5%), repectively. Among the epithelial, adenexal, and mesenchymal origin tumors, basal cell tumor (8.6%), sebaceous adenoma (15.6%), and histiocytoma (25.0%) were predominant in the incidence rate, respectively. In case of mammary gland tumors, 201 (83.8%) were benign and 39 (16.3%) were malignant with a benign to malignant ratio of 5.15. The most frequent mammary gland tumor was benign mixed tumor (35.0%) followed by mammary adenoma-complex type (31.7%).

Distribution and Characteristics of Heterotrophic Plate Count Bacteria in Water Samples from Drinking Water Dispensers (냉온수기에서 일반세균의 분포 및 분리한 세균의 특성)

  • Lee, Eun-Hwa;Koh, Ji-Yun;Kim, Jong-Seol
    • Korean Journal of Microbiology
    • /
    • v.44 no.3
    • /
    • pp.244-250
    • /
    • 2008
  • To evaluate bacteriological water quality, samples were taken from drinking water dispensers placed at S company (S-C) and U highschool (U-H) in Ulsan. The medians of heterotrophic plate counts (HPCs) were 53 CFU/ml for the 74 water samples of S-C and 80 CFU/ml for the 36 cold water samples of U-H, and 38% of the S-C and 42% of the U-H samples showed HPC bacterial concentrations higher than 100 CFU/ml. Coliform bacteria were detected from one sample of S-C. To determine the major source of bacterial contamination, water samples were taken daily for $6\sim8$ days from the bottled water containers as well as the faucets of an experimental water dispenser. While the average HPCs in the bottled water containers were 33 CFU/ml for the first and 132 CFU/ml for the 2nd analysis, the HPC concentration in the cold water samples was 1,022 CFU/ml for the 2nd analysis. These results suggest that the majority of bacteria detected in the cold water samples were originated from the biofilms on the surface of water passages within the water dispensers. There was no significant increase in HPC bacterial concentrations within the bottled water container after installation on the water dispenser. We could isolate and tentatively identify 3 genera 6 species of Gram-positive and 7 genera 7 species of Gram-negative bacteria from the plate count agar plates of U-H samples. Among the isolates, 72% were observed as Gram-positive, and Micrococcus spp. was the most abundant with 54% of the total, followed by Sphingomonas paucimobilis with 16%. It appears that most of the HPC bacteria detected in water dispensers originate from indoor airborne bacteria, which may play important roles in the formation of biofilms on the surface of water passages within the water dispensers.

Geochemical Results and Implication of the Organic Matter in the Holocene Sediments from the Hupo Basin (후포분지 홀로세 퇴적물의 유기물에 대한 지화학 분석 결과 및 의미)

  • Kim, Ji-Hoon;Park, Myong-Ho;Kong, Gee-Soo;Han, Hyun-Chul;Cheong, Tae-Jin;Choi, Ji-Young;Kim, Jin-Ho;Kang, Moo-Hee;Lee, Chi-Won;Oh, Jae-Ho
    • Economic and Environmental Geology
    • /
    • v.43 no.1
    • /
    • pp.1-12
    • /
    • 2010
  • Geochemical approaches on the two recovered piston cores were performed to understand the characteristics of organic matters and the influence of the sea level variation of the East Sea in the Hupo Basin since the Holocene. The analyzing results on organic components (TOC and TN), and isotopic compositions of organic matters showed the variation to core locations and sampling depths. In core 08HZP-01, their values were gradually changed with depth from 4 mbsf to seafloor. However, rapid variation was observed at the boundary of 4.71 mbsf (meter below seafloor) in core 08HZP-03. Based on TOC/TN, $\delta^{13}C_{org}$ and $\delta^{15}N_{org}$, the origin of organic matters in the Hupo Basin can be divided into three groups; 1) predominant marine algae, 2) $C_3$ land plant, and 3) mixture of $C_3$ land plant and marine/freshwater algae. It is likely that the vertical and spatial variations of organic and isotopic compositions reflect the shifts in sedimentary environment (including sediment transportation) by ocean currents and sea-level changes and others during the Holocene period.

A Geographically Weighted Regression on the Effect of Regulation of Space Use on the Residential Land Price - Evidence from Jangyu New Town - (공간사용 규제가 택지가격에 미치는 영향에 대한 공간가중회귀분석 - 장유 신도시지역을 대상으로-)

  • Kang, Sun-Duk;Park, Sae-Woon;Jeong, Tae-Yun
    • Management & Information Systems Review
    • /
    • v.37 no.3
    • /
    • pp.27-47
    • /
    • 2018
  • In this study, we examine how land use zoning affects the land price controlling other variables such as road-facing condition of the land, land form, land age after its development and land size. We employ geographically weighted regression analysis which reflects spatial dependency as methodology with a data sample of land transaction price data of Jangyu, a new town, in Korea. The results of our empirical analysis show that the respective coefficients of traditional regression and geographically weighted regression are not significantly different. However, after calculating Moran's Index with residuals of both OLS and GWR models, we find that Moran's Index of GWR decreases around 26% compared to that of OLS model, thus improving the problem of spatial autoregression of residuals considerably. Unlike our expectation, though, in both traditional regression and geographically weighted regression where residential exclusive area is used as a reference variable, the dummy variable of the residential land for both housing and shops shows a negative sign. This may be because the residential land for both housing and shops is usually located in the level area while the residential exclusive area is located at the foot of a mountain or on a gentle hill where the residents can have good quality air and scenery. Although the utility of the residential land for both housing and shops is higher than its counterpart's since it has higher floor area ratio, amenity which can be explained as high quality of air and scenery in this study seems to have higher impact in purchase of land for housing. On the other hand, land for neighbourhood living facility seems to be valued higher than any other land zonings used in this research since it has much higher floor area ratio than the two land zonings above and can have a building with up to 5 stories constructed on it. With regard to road-facing condition, land buyers seem to prefer land which faces a medium-width road as expected. Land facing a wide-width road may have some disadvantage in that it can be exposed to noise and exhaust gas from cars and that entrance may not be easy due to the high speed traffic of the road. In contrast, land facing a narrow road can be free of noise or fume from cars and have privacy protected while it has some inconvenience in that entrance may be blocked by cars parked in both sides of the narrow road. Finally, land age variable shows a negative sign, which means that the price of land declines over time. This may be because decline of the land price of Jangyu was bigger than that of other regions in Gimhae where Jangyu, a new town, also belong, during the global financial crisis of 2008.

Actual State of Structures and Environmental Control Facilities for Tomato Greenhouses in Chungnam Region (충남지역 토마토 재배온실의 구조와 환경조절설비 실태분석)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Korean Journal of Agricultural Science
    • /
    • v.36 no.1
    • /
    • pp.73-85
    • /
    • 2009
  • An investigation was conducted to get the basic data for establishing structural safety and environmental management of tomato greenhouses in Chungnam region. The contents of the investigation consisted of actual state of greenhouse structures and environmental control facilities. Most of greenhouses were arch type single-span plastic houses and they had too low height for growing tomatoes. Frameworks of multi-span greenhouses were suitable, but those of single-span were mostly insufficient. Every greenhouse had thermal curtain movable or covering fixed inside the greenhouse for energy saving, and heating facilities were mostly warm air heater. Irrigation facilities were mostly drip tube and controlled by manual operation or timer. Almost all of the greenhouses didn't install high level of environmental control facilities such as ventilator, air circulation fan, $CO_2$ fertilizer, insect screen, supplemental light, and cooling device.

  • PDF

Properties of the interfacial oxide and high-k dielectrics in $HfO_2/Si$ system ($HfO_2/Si$시스템의 계면산화막 및 고유전박막의 특성연구)

  • 남서은;남석우;유정호;고대홍
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.45-47
    • /
    • 2002
  • 반도체 소자의 고집적화 및 고속화가 요구됨에 따라 MOSFET 구조의 게이트 절연막으로 사용되고 있는 SiO₂ 박막의 두께를 감소시키려는 노력이 이루어지고 있다. 0.1㎛ 이하의 소자를 위해서는 15Å 이하의 두께를 갖는 SiO₂가 요구된다. 하지만 두께감소는 절연체의 두께와 지수적인 관계가 있는 누설전류를 증가시킨다[1-3]. 따라서 같은 게이트 개패시턴스를 유지하면서 누설전류를 감소시키기 위해서는 높은 유전상수를 갖는 두꺼운 박막이 요구되는 것이다. 그러므로 약 25정도의 높은 유전상수를 갖고 5.2~7.8 eV 정도의 비교적 높은 bandgap을 갖으며, 실리콘과 열역학적으로 안정한 물질로 알려진 HfO2[4-5]가 최근 큰 관심을 끌고 있다. 본 연구에서는 HfO₂ 박막을 실제 소자에 적용하기 위하여 전극 및 열처리에 따른 HfO₂ 박막의 미세구조 및 전기적 특성에 관한 연구를 수행하였다. 이를 위해, HfO₂ 박막을 reactive DC magnetron sputtering 방법으로 증착하고, XRD, TEM, XPS를 사용하여 ZrO₂ 박막의 미세구조를 관찰하였으며, MOS 캐패시터 구조의 C-V 및 I-V 특성을 측정하여 HfO₂ 박막의 전기적 특성을 관찰하였다. HfO₂ 타겟을 스퍼터링하면 Ar 스퍼터링에 의해 에너지를 가진 산소가 기판에 스퍼터링되어 Si 기판과 반응하기 때문에 HfO₂ 박막 형성과 더불어 Si 기판이 산화된다[6]. 그래서 HfO₂같은 금속 산화물 타겟 대신에 순수 금속인 Hf 타겟을 사용하고 반응성 기체로 O₂를 유입시켜 타겟이나 시편위에서 high-k 산화물을 만들면 SiO/sub X/ 계면층을 제어할 수 있다. 이때 저유전율을 갖는 계면층은 증착과 열처리 과정에서 형성되고 특히 500℃ 이상에서 high-k/Si를 열처리하면 계면 SiO₂층은 증가하는 데, 이것은 산소가 HfO₂의 high-k 박막층을 뚫고 확산하여 Si 기판을 급속히 산화시키기 때문이다. 본 방법은 증착에 앞서 Si 표면을 희석된 HF를 이용해 자연 산화막과 오염원을 제거한 후 Hf 금속층과 HfO₂ 박막을 직류 스퍼터링으로 증착하였다. 우선 Hf 긍속층이 Ar 가스 만의 분위기에서 증착되고 난 후 공기중에 노출되지 않고 연속으로 Ar/O₂ 가스 혼합 분위기에서 반응 스퍼터링 방법으로 HfO₂를 형성하였다. 일반적으로 Si 기판의 표면 위에 자연적으로 생기는 비정질 자연 산화막의 두께는 10~15Å이다. 그러나 Hf을 증착한 후 단면 TEM으로 HfO₂/Si 계면을 관찰하면 자연 산화막이 Hf 환원으로 제거되기 때문에 비정질 SiO₂ 층은 관찰되지 않았다. 본 실험에서는 HfO2의 두께를 고정하고 Hf층의 두께를 변수로 한 게이트 stack의 물리적 특성을 살펴보았다. 선증착되는 Hf 금속층을 0, 10, 25Å의 두께 (TEM 기준으로 한 실제 물리적 두께) 로 증착시키고 미세구조를 관찰하였다. Fig. 1(a)에서 볼 수 있듯이 Hf 금속층의 두께가 0Å일때 13Å의 HfO₂를 반응성 스퍼터링 방법으로 증착하면 HfO₂와 Si 기판 사이에는 25Å의 계면층이 생기며, 이것은 Ar/O₂의 혼합 분위기에서의 스퍼터링으로 인한 Si-rich 산화막 또는 SiO₂ 박막일 것이다. Hf 금속층의 두께를 증가시키면 계면층의 성장은 억제되는데 25Å의 Hf 금속을 증착시키면 HfO₂ 계면층은 10Å미만으로 관찰된다. 그러므로 Hf 금속층이 충분히 얇으면 플라즈마내 산소 라디칼, 이온, 그리고 분자가 HfO₂ 층을 뚫고 Si 기판으로 확산되어 SiO₂의 계면층을 성장시키고 Hf 금속층이 두꺼우면 SiO/sub X/ 계면층을 환원시키면서 Si 기판으로의 산소의 확산은 막기 때문에 계면층의 성장은 억제된다. 따라서 HfO₂/Hf(Variable)/Si 계에서 HfO₂ 박막이 Si 기판위에 직접 증착되면, 순수 HfO₂ 박막의 두께보다 높은 CET값을 보이고 Hf 금속층의 두께를 증가시키면 CET는 급격하게 감소한다. 그러므로 HfO₂/Hf 박막의 유효 유전율은 단순 반응성 스퍼터링에 의해 형성된 HfO₂ 박막의 유전율보다 크다. Fig. 2에서 볼 수 있듯이 Hf 금속층이 너무 얇으면 계면층의 두께가 두꺼워 지고 Hf 금속층이 두꺼우면 HfO₂층의 물리적 두께가 두꺼워지므로 CET나 EOT 곡선은 U자 형태를 그린다. Fig. 3에서 Hf 10초 (THf=25Å) 에서 정전 용량이 최대가 되고 CET가 20Å 이상일 때는 high-k 두께를 제어해야 하지만 20Å 미만의 두께를 유지하려면 계면층의 두께를 제어해야 한다.

  • PDF

Asbestos Exposure and Health Risk Assessment for the Residents Near the Abandoned Mining Area in Chungbuk, Korea (충북지역 폐석면광산 인근주민의 석면노출과 건강위해도 평가)

  • Shin, Jin-Ho;Oh, Seok-Ryul;Hwang, Soon-Yong;Chung, Sook-Nye;Kim, Ji-Hui;Nam, Eun-Jung;Lee, Jin-Hyo;Choi, Hee-Jin;Eom, Seok-Won;Chae, Young-Zoo;Park, Chul-Hwi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.5
    • /
    • pp.345-350
    • /
    • 2012
  • To investigate the exposure and health risk assessment for the residents near the D-asbestos mine in Chungbuk, Korea. We analyzed asbestos in the 20 ambient air and 23 activity based samples near the mine. The airborne sample results are showed that 8 of 20 samples ranged between 0.0025 to 0.0029 f/cc (fiber per cubic centimeter) and the others were below the detection limit by phase contrast microscopy (PCM). In addition, asbestos fibers were under the detection limit or not being by transmission electron microscopy (TEM). Based on interview and survey targeting the local residents, we made the activity based sampling (ABS) scenarios fit to the conditions of field. At the same time, we calculated the excess lifetime cancer risk (ELCR) of these ABS scenarios according to the ELCR average value and 95% upper confidence limit (UCL). At the case of weed whacking, soil digging and sweeping yard scenario, 95% UCL of ELCR exceeded the $1{\times}10^{-4}$, acceptable risk range for exposure. Based on our study results, it is necessary safety measures such as risk communication, abatement or management of naturally occurring asbestos (NOA).