• Title/Summary/Keyword: 기압

Search Result 885, Processing Time 0.033 seconds

Experimental Models of Schizophrenia (정신분열병의 실험적 모델)

  • Cheon, Jin-Sook
    • Korean Journal of Biological Psychiatry
    • /
    • v.6 no.2
    • /
    • pp.153-160
    • /
    • 1999
  • Animal models can provide a useful tool for the study of some aspects of psychiatric disorders and their treatment. The four criteria for the evaluation of animal models of psychiatric disorders are as following : 1) similarity of inducing conditions 2) similarity of behavioral state 3) common underlying neurobiological mechanisms 4) reversal by clinically effective treatment techniques. Several animal models have been proposed for schizophrenia : phenylethylamine model, L-dopa model, hallucinogen model, cocaine model, amphetamine model, phencyclidine model, noradrenergic reward system lesion model, reticular stimulation model, social isolation model, conditioned avoidance reaction, catalepsy test, paw test, self-stimulation paradigms, latent inhibition paradigms, blocking paradigms, prepulse inhibition of the startle reflex, rodent interaction, social behavior in monkeys, hippocampal damage, high ambient pressure, and models using selective breeding. Among them, animals with bilateral lesion of the hippocampus may provide an adequate animal model for several symptoms of schizophrenia, and ketamine model can reproduce negative symptoms and cognitive deficits as well as positive symptoms of schizophrenia. In conclusion, no model of schizophrenia is entirely representative of the disease, and findings gleaned from model systems must be cautiously interpreted. Furthermore, the process of developing and validating animal models must work in concert with the process to identify reliable measures of human phenomenology.

  • PDF

Development of Theme-Based Integrated Unit in the Middle School Science and Analysis of it's Effects (중학교 과학수업을 위한 주제중심 통합단원의 개발 및 효과 분석)

  • Park, Soo-Kyong;Kim, Sang-Dal;Ju, Gook-Yong;Nam, Youn-Kyong
    • Journal of the Korean earth science society
    • /
    • v.22 no.5
    • /
    • pp.350-359
    • /
    • 2001
  • The purpose of this study is to develop theme-based integrated science unit by the interdisciplinary approach and to analyze it's effects on the science achievement and the attitude towards science learning. 'Interaction' and 'Stability' were selected as the integrated themes, and the main concept and subconcept in relation to the themes were extracted from the four areas of science, and the learning contents were constructed in the integrated ways. While the main concept have relevance to subconcept in the interaction, the main concept have little relevance to subconcept in the stability. Therefore, the stability was to fit with middle school integrated science theme, but the interaction was not. The theme-based integrated science units developed was implemented in middle school, and the results are follows. First, the science achievement of group of theme-based integrated science teaching is significantly higher than those of group of traditional teaching. Second, the scores of the test of attitude toward science learning of the group of theme-based integrated science teaching is significantly higher than those of group of traditional teaching. Third, the students' perception of theme-based integrated science teaching was positive. The students have participation, interest, motivation in theme-based integrated science teaching, and students have difficulty in learning theme-based integrated science teaching.

  • PDF

Petrology of Host Body of Feldspar Deposits in Jechon Ganites (장석광상 모암인 제천반상화강암의 암석학적 특성)

  • Lee, Han-Yeang;Kim, Dai-Oap;Park, Joong-Kwon
    • Journal of the Korean earth science society
    • /
    • v.22 no.5
    • /
    • pp.405-414
    • /
    • 2001
  • Jecheon granite can be divided into two types; porphyritic granite (K-feldspar megacryst bearing) and medium-grained biotite granite. Porphyritic granite, host body of feldspar deposits, is 8${\sim}$11 km in diameter and about 80 $km^{2}$ in area. It mainly contains K-feldspar, plagioclase, biotite and quartz, and magnetite, zircon, sphene and apatite are accessary minerals. Enclosed minerals in K-feldspar megacryst with 3${\sim}$10 cm in diameter are hornblende, plagioclase, quartz, magnetite, apatite, sphene and zircon. Mafic enclaves mainly consisting of hornblende, plagioclase and quartz are frequently observed in porphrytic granite. Medium-grained biotite granite consists of K-feldspar, plagioclase, biotite and hornblende as main, and hematite, muscovite, apatite and zircon as accessary minerals. Core and rim An contents of plagioclase from porphyritic granite, medium biotite granite, K-feldspar megacryst, and mafic enclave are 36 and 21, 40 and 32, 37 and 32, and 43 and 36, respectively. $X_{Fe}$ values of hornblende are 0.57 at biotite granite, 0.51 at K-feldspar mehacryst and 0.45 at mafic enclave. $X_{Fe}$ values of biotite and hornblende are homogeneous without chemical zonation. K-feldspar megacryst shows end member of pure composition with exsolved thin lamellar pure albites. Characteristics of mineral compositions and petrography indicate porphyritic granite is igneous origin and medium-grained biotite granite comes from the same source of magma; biotite granite is initiated to solidly and from residual melt porphyritic granite can be formed. Possibly K-feldspar megacrysts are formde under H$_{2}$O undersaturation condition and near K-feldspar solidus curve temperature; growth rate is faster than nucleation rate. Mafic enclaves are thought to be mingled mafic magma in felsic magma, which is formed from compositional stratigraphy. Estimated equilibrium temperature and pressure for medium-grained biotite granite are about $800^{\circ}C$ and 4.83${\sim}$5.27 Kb, respectively.

  • PDF

Cloud-cell Tracking Analysis using Satellite Image of Extreme Heavy Snowfall in the Yeongdong Region (영동지역의 극한 대설에 대한 위성관측으로부터 구름 추적)

  • Cho, Young-Jun;Kwon, Tae-Yong
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.1
    • /
    • pp.83-107
    • /
    • 2014
  • This study presents spatial characteristics of cloud using satellite image in the extreme heavy snowfall of the Yeongdong region. 3 extreme heavy snowfall events in the Yeongdong region during the recent 12 years (2001 ~ 2012) are selected for which the fresh snow cover exceed 50 cm/day. Spatial characteristics (minimum brightness temperature; Tmin, cloud size, center of cloud-cell) of cloud are analyzed by tracking main cloud-cell related with these events. These characteristics are compared with radar precipitation in the Yeongdong region to investigate relationship between cloud and precipitation. The results are summarized as follows, selected extreme heavy snowfall events are associated with the isolated, well-developed, and small-scale convective cloud which is developing over the Yeongdong region or moving from over East Korea Bay to the Yeongdong region. During the period of main precipitation, cloud-cell Tmin is low ($-40{\sim}-50^{\circ}C$) and cloud area is small (17,000 ~ 40,000 $km^2$). Precipitation area (${\geq}$ 0.5 mm/hr) from radar also shows small and isolated shape (4,000 ~ 8,000 $km^2$). The locations of the cloud and precipitation are similar, but in there centers are located closely to the coast of the Yeongdong region. In all events the extreme heavy snowfall occur in the period a developed cloud-cell was moving into the coastal waters of the Yeongdong. However, it was found that developing stage of cloud and precipitation are not well matched each other in one of 3 events. Water vapor image shows that cloud-cell is developed on the northern edge of the dry(dark) region. Therefore, at the result analyzed from cloud and precipitation, selected extreme heavy snowfall events are associated with small-scale secondary cyclone or vortex, not explosive polar low. Detection and tracking small-scale cloud-cell in the real-time forecasting of the Yeongdong extreme heavy snowfall is important.

Pulmonary Thromboendarterectomy for Pulmonary Hypertension Caused by Chronic Pulmonary Thromboembolism (만성폐색전중으로 인한 폐동맥고혈압 환자에서 시행한 폐동맥내막절제술)

  • Song Seung-Hwan;Jun Tae-Gook;Lee Young-Tak;Sung Ki-Ick;Yang Ji-Hyuk;Choi Jin-Ho;Kim Jin-Sun;Kim Ho-Joong;Park Pyo-Won
    • Journal of Chest Surgery
    • /
    • v.39 no.8 s.265
    • /
    • pp.626-632
    • /
    • 2006
  • Background: Pulmonary hypertension caused by chronic pulmonary embolism is underrecognized and carries a poor prognosis. Medical therapy is generally unsatisfactory and palliative. With the improvement of operative technique and postoperative management, pulmonary endarterectomy has been the treatment of choice for this condition. Material and Method: Between January 2001 and December 2005, eleven patients were received pulmonary endarterectomy. All patients had chronic dyspnea and exercise intolerance. Diagnosis was made with cardiac echocardiography, lung perfusion scan and computed tomography. Before the operation, Greenfield vena cava filter were placed in all patient except one. Deep hypothermic circulatory arrest was used for the distal-most portion of the endarterectomy procedure. More than moderate degree of tricuspid reguirgitation was repaired during operation. Result: There was no early and late death. Right ventricular systolic pressure was reduced significantly after operation from $91{\pm}21$ mmHg to $40{\pm}17$ mmHg on echocardiography (p=0.001). NYHA class and tricuspid reguirgitaion were improved postoperatively. Although mild reperfusion injury in three case and postoperative delirium in one case were observed, all of them recovered without complication. Conclusion: Pulmonary thromboendarterctomy offers to patient an acceptable morbidity rate and anticipation of clinical improvement. This method is safe and effective operation for pulmonary hypertension caused by chronic pulmonary thromboembolism.

Clinical Results alter Pulmonary Endarterectomy as a Curative Surgical Method in Chronic Thromboembolic Pulmonary Hypertension: an Approach to Operative Classification of Thromboembolic Disease (만성 폐동맥 색전증의 치료로서 내막제거술의 임상적 결과: 색전증 분류에 따른 접근)

  • Lim, Ju-Yong;Lee, Jae-Won;Kim, Jeong-Won;Jung, Sung-Ho;Je, Hyoung-Gon;Song, Hyun;Chung, Cheol-Hyun;Choo, Suk-Jung
    • Journal of Chest Surgery
    • /
    • v.41 no.5
    • /
    • pp.591-597
    • /
    • 2008
  • Background: Pulmonary endarterectomy is widely accepted as a treatment for chronic thromboembolic pulmonary hypertension. Based on our experiences, we sought to find ways to reduce perioperative complications and to improve surgical outcomes in patients undergoing pulmonary endarterectomy. Material and Method: This study was designed as a retrospective analysis of 20 patients with pulmonary hypertension who underwent pulmonary endarterectomy between January 1998 and March 2008. All patients presented with chronic dyspnea. Deep vein thrombosis (DVT) was the major cause of chronic pulmonary thromboembolism (55%). Seventeen patients (85%) underwent inferior vena cava (IVC) filter placement. Thirteen patients underwent surgery under total circulatory arrest, while the others underwent surgery while on low flow cardiopulmonary bypass. Concomitant tricuspid annuloplasty was done in 6 patients (66%) whose tricuspid regurgitation was as severe as grade IV/IV. The mean follow-up duration was $45{\pm}32$ months. Result: Using of University of California, San Diego (UCSD), thromboembolism classification, 4 patients (20%) were type 1, 8 patients (40%) were type II, and 8 patients (40%) were type III. Right ventricular systolic pressure was reduced significantly from $77{\pm}29$ mmHg to $37{\pm}19$ mmHg after pulmonary endarterectomy (p<0.001). The degree of tricuspid regurgitation and the NYHA functional class were all improved postoperatively. Reperfusion edema occurred in 7 cases (35%). The incidence of reperfusion edema was higher in the UCSD type III group than in the other group (25% vs 50%, p=0.25) and the length of postoperative intensive care unit stay was longer in type III group ($5{\pm}2$ days vs $9{\pm}7$ days, p=0.07). The early mortality rate was 10%, and the late mortality rate was 15% (n=3); one death was due to progression of underlying non-Hodgkin's lymphoma, and the other deaths were related to recurrent thromboembolism and persistent pulmonary hypertension, respectively. Conclusion: Pulmonary endarterectomy, as a curative surgical method for treating chronic thromboernbolic pulmonary hypertension, should be performed aggressively in patients diagnosed with chronic thromboembolic pulmonary hypertension, and an effort should be made to reduce the frequency of perioperative complications and to improve surgical outcomes.

Evaluation of cardiac function by tissue Doppler imaging in children with cancer (Tissue Doppler imaging을 이용한 소아 종양 환자에서의 심기능 평가)

  • Kim, Yeo Hyang
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.4
    • /
    • pp.417-423
    • /
    • 2006
  • Purpose : The objectives of this study were to assess ventricular function by tissue Doppler imaging in children who were receiving chemotherapy or who had received chemotherapy, and to apply repeated tissue Doppler imaging to make an early assessment in cardiac toxicity studies. Methods : This study was conducted on 23 oncology patients on-treatment or off-treatment from April 2005 to July 2005 at Dongsan Medical Center, Keimyung University. All patients(group 1) were divided into two groups, fractional shortening(FS) over 29 percent(group 2) and FS under 28 percent (group 3) in the first category. These same patients were also divided into the following groups : group treated with anthracyclin(group 4) and group treated without anthracyclin(group 5). Deceleration time(DT), isovolumic relaxation time(IVRT), FS, peak early diastolic(E), and peak late diastolic (A) velocity of transmitral flow were measured by M-mode and pulsed wave Doppler. Systolic(Sm), peak early diastolic(Em), and peak late diastolic(Am) velocity in apical 4-chamber and 2-chamber views were measured by tissue Doppler imaging. The author calculated a modified Tei index, E/A, E/Em ratio by using measured values. Results : Twenty three patients were enrolled : 12 boys and 11 girls. The average age of patients was 8 years and 4 months. Thirteen out of 23 patients were in the group treated with anthracyclin (group 4) and 6 had FS under 28 percent(group 3). E/Em ratio showed a significant difference between group 1 and control group($6.46{\pm}1.85$ vs $7.06{\pm}1.64$, P<0.05). Other parameters had no difference statistically. Conclusion : This study showed that the change of cardiac function developed earlier in diastolic function than in systolic function, as E/Em ratio reflecting the mean LV diastolic pressure showed a significant difference between the control group and chemotherapy groups. Echocardiography using tissue Doppler imaging is a non-invasive, comfortable and reliable method for post-chemotherapy follow up.

Remediation of Sediments using Micro-bubble (미세기포를 이용한 퇴적물 정화)

  • Kang, Sang Yul;Kim, Hyoung Jun;Kim, Tschung Il;Park, Hyun Ju;Na, Choon Ki;Han, Moo Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.8
    • /
    • pp.420-427
    • /
    • 2016
  • This study was conducted on the sediment remediation using micro-bubble to remove fine particles. For this study, characteristics of contamination and release in sediment were analyzed. And then, the characteristics of bubbles on removal efficiency was investigated at various operation conditions. In particle size distribution of the sediment used for the study, the proportion of clay and silt (<0.075 mm) was about 7.7%, sand (0.075~4.75 mm) was about 67.8%, and gravel (${\geq}4.75$) was 24.5%. Total nitrogen (TN) and total phosphorus (TP) of the sediment were 2,790~3,260, 261~311 mg/kg respectively. Ignition loss and water content were 4.1~9.6, 32.9~53.2% respectively. In analysis of removal efficiency according to operation conditions of micro-bubble, it was the highest when operation condition is pressure 6 atm, pressurized water ratio 30%, and coagulant dosage 15 ppm. At the time, the sediment's removal efficiency was 19.9%. Accordingly removal efficiency of TN and TP were 21.4, 22.6% respectively. Finally a research was found that fine particles in sediment were almost removed by micro-bubble, which led to decrease nutrients' release at about 20.1~64.3% in comparison to sediment including lots of fine particles.

Comparison of Radiation Dose in the Measurement of MDCT Radiation Dose according to Correction of Temperatures and Pressure, and Calibration of Ionization Chamber (MDCT 선량측정에서 온도와 압력에 따른 보정과 Ionization Chamber의 Calibration 전후 선량의 비교평가)

  • Lee, Chang-Lae;Kim, Hee-Joung;Jeon, Seong-Su;Cho, Hyo-Min;Nam, So-Ra;Jung, Ji-Young;Lee, Young-Jin;Lee, Seung-Jae;Dong, Kyung-Rae
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2008
  • This study aims to conduct the comparative analysis of the radiation dose according to before and after the calibration of the ionization chamber used for measuring radiation dose in the MDCT, as well as of $CTDI_w$ according to temperature and pressure correction factors in the CT room. A comparative analysis was conducted based on the measured MDCT (GE light speed plus 4 slice, USA) data using head and body CT dosimetric phantom, and Model 2026C electrometer (RADICAL 2026C, USA) calibrated on March 21, 2007. As a result, the $CTDI_w$ value which reflected calibration factors, as well as correction factors of temperature and pressure, was found to be the range of $0.479{\sim}3.162mGy$ in effective radiation dose than the uncorrected values. Also, under the routine abdomen routine CT image acquisition conditions used in reference hospitals, patient effective dose was measured to indicate the difference of the maximum of 0.7 mSv between before and after the application of such factors. These results imply that the calibration of the ion chamber, and the correction of temperature and pressure of the CT room are crucial in measuring and calculating patient effective dose. Thus, to measure patient radiation dose accurately, the detailed information should be made available regarding not only the temperature and pressure of the CT room, but also the humidity and recombination factor, characteristics of X-ray beam quality, exposure conditions, scan region, and so forth.

  • PDF

GIS-based Disaster Management System for a Private Insurance Company in Case of Typhoons(I) (지리정보기반의 재해 관리시스템 구축(I) -민간 보험사의 사례, 태풍의 경우-)

  • Chang Eun-Mi
    • Journal of the Korean Geographical Society
    • /
    • v.41 no.1 s.112
    • /
    • pp.106-120
    • /
    • 2006
  • Natural or man-made disaster has been expected to be one of the potential themes that can integrate human geography and physical geography. Typhoons like Rusa and Maemi caused great loss to insurance companies as well as public sectors. We have implemented a natural disaster management system for a private insurance company to produce better estimation of hazards from high wind as well as calculate vulnerability of damage. Climatic gauge sites and addresses of contract's objects were geo-coded and the pressure values along all the typhoon tracks were vectorized into line objects. National GIS topog raphic maps with scale of 1: 5,000 were updated into base maps and digital elevation model with 30 meter space and land cover maps were used for reflecting roughness of land to wind velocity. All the data are converted to grid coverage with $1km{\times}1km$. Vulnerability curve of Munich Re was ad opted, and preprocessor and postprocessor of wind velocity model was implemented. Overlapping the location of contracts on the grid value coverage can show the relative risk, with given scenario. The wind velocities calculated by the model were compared with observed value (average $R^2=0.68$). The calibration of wind speed models was done by dropping two climatic gauge data, which enhanced $R^2$ values. The comparison of calculated loss with actual historical loss of the insurance company showed both underestimation and overestimation. This system enables the company to have quantitative data for optimizing the re-insurance ratio, to have a plan to allocate enterprise resources and to upgrade the international creditability of the company. A flood model, storm surge model and flash flood model are being added, at last, combined disaster vulnerability will be calculated for a total disaster management system.