• 제목/요약/키워드: 기류제한

검색결과 28건 처리시간 0.025초

제한공간에 설치된 제트팬의 기류특성 예측 (Prediction of the Flow Characteristics of Jet Fan in a Confined Space)

  • 이재헌;환유준;김경환;임윤철;오명도;김종필
    • 설비공학논문집
    • /
    • 제14권3호
    • /
    • pp.206-213
    • /
    • 2002
  • In this paper, the flow characteristics of an axial fan spraying isothermal compact jet in a confined space were investigated by the experimental methods, the numerical method, and the free jet theory According to the results, the numerical result and the experimental result are agreed well qualitatively and different quantitatively within $\pm1.0%$ for the centerline velocity, the entrainment ratio, and the maximum throw. However, the free jet theory can reasonably predict the centerline velocity except the entrainment ratio and the maximum throw. In other words, the entrainment ratio and the maximum throw by 1.he free jet theory are hard to estimate the characteristics of jet because of restriction of c confined space.

공기청정기에 의한 실내기류 해석 (Analysis of Indoor Air-flow with Air Cleaners)

  • 김영생;모진용;이재권;한재오
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.57-62
    • /
    • 2005
  • 본 연구는 공기청정기의 성능에 영향을 미치는 인자로서 홉입구, 배기구의 위치 및 형상, 그리고 실내 공간상 배치 등에 대해 수치해석에 의한 모사를 통하여 평가하였다. 해석방법으로는 먼저 유동장을 해석한 후 고정된 유동장 내에서의 먼지 입자의 거동을 검토하였다. 배기구 위치에 의한 성능해석 결과는 배기구를 상면에 위치하게 할 경우 양 측면에 위치한 구조보다 우수한 성능을 나타내었으며, 설치위치에 대한 성능해석 결과는 제한적이나 현관 옆에 설치할 경우 해석된 두 가지 모델 모두 우수한 성능을 나타내었다.

  • PDF

부속실제연설비 급기댐퍼의 설치위치 적정성 연구 (A Study on the Adequacy of the Installation Location of the Air Supply Damper of the Attached Actual Smoke Facility)

  • 양성훈
    • 한국재난정보학회:학술대회논문집
    • /
    • 한국재난정보학회 2022년 정기학술대회 논문집
    • /
    • pp.193-194
    • /
    • 2022
  • 본 연구에서는 특별피난계단의 전실에 설치되는 부속실제연설비가 화재 시 발생한 연기가 부속실 내로 역류하지 않는 급기댐퍼의 적정한 설치위치를 알아보고자 하였으며, 이를 확인하기 위하여 FDS(Fire Dynamics Simulator)을 사용 하였다. 시뮬레이션 Case 총 15가지로 구분하고, 방연풍속은 총 64개의 지점에서 측정하는 시뮬레이션을 수행하였다. 시뮬레이션 결과 출입문 상부 및 하부에서 역 기류가 발행하는 Case가 있었으며, 대부분 출입문 하부에서의 연기 유입이 예상되는 경우가 많았다. 방연풍속은 측정 포인트 64점에서 관련기준에 단 한 곳도 미달하지 않고 만족하는 경우는 총 단 4가지 Case로서 매우 제한적인 것을 알 수 있었다. 그만큼 급기댐퍼의 위치 및 급기방향에 따라 부속실 제연설비의 성능이 다양하게 나타날 수 있다는 것이다. 본 연구를 바탕으로 앞으로 실물실험을 통하여 구체적인 자료가 입증되길 바라고, 더불어 부속실 제연설비의 성능을 개선하는 데 있어 도움이 되었으면 한다.

  • PDF

광산 이직근로자의 만성폐쇄성폐질환 기류제한 중증도와 염증 및 산화스트레스 (Inflammation and Oxidative Stress as related to Airflow Limitation Severity in Retired Miners with Chronic Obstructive Pulmonary Disease)

  • 이종성;신재훈;백진이;정지영;최병순
    • 한국산업보건학회지
    • /
    • 제29권2호
    • /
    • pp.251-258
    • /
    • 2019
  • Objective: Chronic obstructive pulmonary disease(COPD) is characterized by persistent airflow limitations associated with chronic inflammatory response due to noxious particles or gases in the lung. Inflammation and oxidative stress are associated with COPD. The aim of this study was to evaluate the relationship among inflammation, oxidative stress, and airflow limitation severity in retired miners with COPD. Methods: The levels of serum high-sensitivity C-reactive protein(hsCRP) as a biomarker for inflammation, degree of reactive oxygen metabolites(dROMs) and biological antioxidants potential(BAP) in plasma as biomarkers for oxidative stress were measured in 211 male subjects with COPD. Degree of airflow limitation severity as determined by spirometry was divided into three grades grouped according to the classification of the Global Initiatives for Obstructive Lung Disease(GOLD)(1, mild; 2, moderate; $3{\leq}$, severe or more) using a fixed ratio, post- bronchodilator $FEV_1/FVC$ < 0.7. Results: Mean levels of dROMs significantly increased in relation to airflow limitation severity(GOLD 1, 317.8 U.CARR vs. GOLD 2, 320.3 U.CARR vs. GOLD $3{\leq}$, 350.9 U.CARR, p=0.047) and dROMs levels were correlated with serum hsCRP levels(r=0.514, p<0.001). Mean levels of hsCRP were higher in current smokers(non-smoker, 1.47 mg/L vs. smoker, 2.34 mg/L, p=0.006), and tended to increase with degree of airflow limitation severity(p=0.071). Mean levels of BAP were lower in current smokers(non-smoker, $1873{\mu}mol/L$ vs. smoker, $1754{\mu}mol/L$, p=0.006). Conclusions: These results suggest that inflammation and oxidative stress are related to airflow limitation severity in retired miners with COPD, and there was a correlation between inflammation and oxidative stress.

만성폐쇄성폐질환자에서 기류제한 및 COPD 복합지수와 말초산소포화도의 연관성 (Association of Airflow Limitation and COPD Composite Index with Peripheral Oxygen Saturation in Patients with Chronic Obstructive Pulmonary Disease)

  • 이종성;신재훈;백진이;손혜림;최병순
    • 한국산업보건학회지
    • /
    • 제34권1호
    • /
    • pp.57-66
    • /
    • 2024
  • Objective: Chronic obstructive pulmonary disease (COPD) is characterized by progressive airflow obstruction that is only partly reversible, inflammation in the airways, and systemic effects. This study aimed to investigate the association between low peripheral oxygen saturation levels (SpO2), and composite indices predicting death in male patients with (COPD). Method: A total of 140 participants with post-bronchodilator FEV1/FVC ratio less than 0.7 were included. Three composite indices (ADO, DOSE, BODEx) were calculated using six variables such as age (A), airflow obstruction (O), body mass index (B), dyspnea (D), exacerbation history (E or Ex), and smoking status (S). Severity of airflow limitation was classified according to Global Initiative for Obstructive Lung Disease (GOLD) guidelines. SpO2 was measured by pulse oximetry, and anemia and iron deficiency were assessed based on blood hemoglobin levels and serum markers such as ferritin, transferrin saturation, or soluble transferrin receptor. Results: Participants with low SpO2 (<95%) showed significantly lower levels of %FEV1 predicted (p=0.020) and %FEV1/FVC ratio (p=0.002) compared to those with normal SpO2 levels. The mMRC dyspnea scale (p<0.001) and GOLD grade (p=0.002) showed a significant increase in the low SpO2 group. Receiver Operating Characteristic analysis revealed higher area under the curve for %FEV1 (p=0.020), %FEV1/FVC(p=0.002), mMRC dyspnea scale (p=0.001), GOLD grade (p=0.010), ADO (p=0.004), DOSE (p=0.002), and BODEx (p=0.011) in the low SpO2 group. Conclusion: These results suggest that low SpO2 levels are related to increased airflow limitation and the composite indices of COPD.

기류 제한에 영향을 미치는 허탈성 기도의 분석 (The detection of collapsible airways contributing to airflow limitation)

  • 김윤성;박병규;이경인;손석만;이효진;이민기;손춘희;박순규
    • Tuberculosis and Respiratory Diseases
    • /
    • 제43권4호
    • /
    • pp.558-570
    • /
    • 1996
  • 연구배경 : 허탈성 기도의 분석은 만성 기도 질환 및 기관지 천식의 치료에 있어서 중요성을 가지고 있다. 순수한 허탈성 기도 질환과 기관지 천식에 의한 허탈성 기도 질환의 감별은, 전자는 pursed lip breathing이나 nasal positive pressure ventilation으로 치료하며, 후자는 약물요법이 사용된다는 점에서 중요하다. 기관지 천식이나 폐기종의 요인으로 고려되는 허탈성 기도는 비가역적인 기류 제한의 한 형태이며, 그것은 폐활량 측정법에 의해 측정되는 용적과 체적 기록법에 의해 측정되는 가스 압박에 의한 용적과의 차이를 비교함으로써 접근할 수 있다. 방법 : 폐활량 측정법을 이용하여 폐활량과 노력성 폐활량(SVC-FVC) 사이의 용적 차이를 측정함으로써, 기도 허탈의 지표로 유용한지를 조사하기 위해, 1995년 1월부터 7월까지, 본원 폐기능 검사실에 내원한 기류 폐쇄가 있는 환자 20명(만성폐쇄성폐질환 12명, 안정시의 기관지천식 7명, 만성폐쇄성폐질환과 기관지천식이 병합된 1명)과, 기류 폐쇄의 소견이 보이지 않는 정상인 20명을 대상으로 폐활량 측정법과 체적 기록법을 이용하여, 기관지 확장제 투여 전후의 폐활량 측정법 검사지표들의 변화를 측정하였다. 결과 : 1) 기류 폐쇄가 있는 환자의 평균 연령은 $58.3{\pm}7.24$(세), 신장은 $166{\pm}8.0$(cm), 체중은 $59.0{\pm}9.9$(kg)였으며, 정상인의 평균 연령은 $56.3{\pm}12.47$(세), 신장은 $165.9{\pm}6.9$(cm), 체중은 $64.4{\pm}0.4$(kg)으로 유의한 차이는 없었으며(p>0.05), 남녀비는 각각 14:6이었다. 2) 환자군의 SVC-FVC는 $395{\pm}317ml$, 정상군의 SVC-FVC는 $154{\pm}176ml$로 유의한 차이가 있었으며(p<0.05), 두 군의 분별치를 208ml로 했을때 민감도와 특이도가 가장 높았다. 3) 기관지 확장제 투여후, 폐활량 측정법이나 체적 기록법으로 가역성 기도 폐쇄를 보인 경우는 환자군에서 16명, 대조군에서는 7명이었으며(p<0.05), 기관지 확장제 반응군 및 비반응군의 SVC-FVC는 각각 $300.4{\pm}306ml$, $144.7{\pm}180ml$로 유의 한 차이가 있었다(p<0.05). 4) 기관지 확장제 투여전의 SVC-FVC는, 기도 저항(Raw)과 연관이 있었으며(r=0.307 p=0.05), 기관지 확장제 투여후의 SVC-FVC는, 기관지 확장제 투여전의 SVC-FVG(r=0.559 p=0.0002), TGV(r=0.488 p=0.002)및 기관지 확장제 투여후의 기도 저항(r=0.583 p=0.0001), TGV(r=0.375 p=0.0170)와 연관이 있었다. 5) 전체 실험군에서 흡연자(28명)와 비흡연자(12명)의 SVC-FVC는 각각 $267.5{\pm}303ml$, $277.5{\pm}276ml$이었으며, 통계적 유의성은 없었다(p>0.05). 결론 : 폐활량계에 의한 SVC-FVC측정이 허탈성 기도를 분석하고, 치료방침을 결절하는데 도움을 줄 수 있을 것으로 기대된다.

  • PDF

석탄가스화 기술 소개 및 개발 동향

  • 이진욱;윤용승;이승종
    • NICE (News & Information for Chemical Engineers)
    • /
    • 제31권1호
    • /
    • pp.48-57
    • /
    • 2013
  • 석탄가스화 기술은 석탄의 에너지원으로서의 중요성에 더하여 고효율 고청정 에너지화 기술이라는 측면에서 많은 기술선진국에서 시장 선점을 위하여 다양한 석탄가스화 기술을 개발하고 있다. 초기에는 미국과 유럽을 중심으로 기술개발이 이루어졌으나 최근에는 일본과 중국에서도 상업화 기술을 보유하는 수준에 이르렀다. 특히 중국은 우리나라보다 뒤늦게 기술개발을 시작하여 2000년 이전에만 하여도 석탄가스화 기술의 후진국이었으나 최근에는 ECUST와 TPRI 등이 주도적으로 기술개발을 진행하고 집중적인 연구개발 지원에 힘입어 이제 2,000톤/일급 이상의 가스화기 개발을 완료하고 수십기의 상업용 실적을 보유하는 등으로 비약적인 발전을 이루었다. 반면에 우리나라는 중국보다 이른 시점인 1990년대 초반부터 가스화 기술개발을 시작하여 많은 기술축적을 이루어 미분탄 기류 수송, 슬러리 제조, 탈황 기술 등의 일부 요소기술에서는 세계 수준급의 기술을 확보하고 있으나 연구비의 제한적인 투자로 인하여 규모의 측면에서는 아직 수톤~수십톤/일급 가스화기의 운전 또는 설계 진행 수준에 머무르고 있다. 우리나라의 경우 에너지의 대부분을 수입한다는 측면을 고려할 때에 저가의 에너지원 확보 및 에너지원의 다양성 확보 측면에서 석탄에너지 활용은 필수적이므로 석탄 활용 기술, 특히 석탄가스화 기술 개발에 많은 관심을 기울일 필요성이 아주 강하다고 판단된다.

수치해석을 통한 반밀폐공간 내 수소가스 누출 시 농도변화에 관한 연구 (Numerical analysis study on the concentration change at hydrogen gas release in semi-closed space)

  • 백두산;김효규;박진욱;유용호
    • 한국터널지하공간학회 논문집
    • /
    • 제23권1호
    • /
    • pp.25-36
    • /
    • 2021
  • 온실가스 배출량을 줄이기 위해 내연기관 자동차에 대한 제한을 두고, 친환경자동차 보급 확대 정책을 내놓고 있다. 수소 전기자동차의 수소는 가연 범위 및 폭발 범위가 넓고, 폭발화염 전파속도가 매우 빠른 가연성 가스이기 때문에, 제조, 수송, 저장 시 누출, 확산, 점화 및 폭발 등의 위험성을 가지고 있다. 수소전기자동차의 연료탱크에는 폭발 등 위험성을 감소시키기 위해 온도감응식 압력방출장치(Thermally activate Pressure Relief Device, TPRD)가 있어, 사고가 발생했을 경우 폭발, 화재 등이 발생하기 전에 탱크 내부의 수소를 밖으로 방출한다. 그러나 지하주차장이나 터널과 같은 반밀폐공간에서 사고가 발생할 경우 공간 내 기류의 유동이 개방된 공간보다 미미하기 때문에 TPRD로부터 방출된 수소가스의 농도가 폭발하한계 이상으로 누적될 수 있는 등 문제가 발생할 수 있다. 따라서 본 연구에서는 TPRD의 노즐의 직경에 따라 시간에 따른 수소의 누출 유량을 분석하고, 반밀폐공간에서 수소가 누출될 경우 수소 농도변화를 수치해석으로 검토하였다. 노즐의 직경은 1 mm, 2.5 mm, 5 mm로 검토를 하였으며, 노즐 직경에 따라 지하주차장 내의 수소농도는 노즐의 직경이 클수록 빠른 시간에 농도가 높아지며, 최대값 또한 노즐 직경이 클수록 큰 것으로 분석되었다. 기류가 정체된 지하주차장에서는 노즐 주변에서 폭발하한계 이상의 수소 농도가 분포하는 것으로 분석되었으며, 폭발상한계를 넘지는 않는 것으로 분석되었다.

전자매뉴얼을 활용한 도시재생사업의 법.행정절차 제공 시스템의 개념적 모형 (A Conceptual Model for an Administrative and Legal Process Provider of Urban Regeneration using Construction Interactive Electronic Technical Manual)

  • 박문서;정진욱;이현수
    • 한국건설관리학회논문집
    • /
    • 제11권3호
    • /
    • pp.33-42
    • /
    • 2010
  • 최근 건설 산업은 IT기술의 발전과 함께 새로운 기류를 맞고 있다. 컴퓨터를 이용한 다양하고 신속한 정보 및 지식관리가 이루어지고 있으며 사용자간 의사소통도 활발하게 이루어지고 있다. 이미 시공단계의 정보들을 처리해 주는 PMIS와 사용자들의 업무 노하우를 공유하는 수단인 KMS와 같은 시스템이 현장에 적용 되어 활용되고 있고, 최근에는 전자매뉴얼(IETM)로 대변되어지는 생애주기 전반의 법, 행정 절차제공자에 관한 연구로 범위가 확장되고 있다. 그러나 도시재생사업과 같은 대규모 건설사업의 경우 사용주체와 용도에 따라 주요 기능이 역동적으로 변화되는데 이 역동성은 전자매뉴얼 고유의 역할을 제한하기도 하고 기존의 시스템들과 경계를 모호하게 하기도 한다. 이에 본 연구에서는 경력 실무자들을 대상으로한 설문과 인터뷰, 건설프로젝트의 특성 분석을 통하여 건설분야 전자매뉴얼이 갖추어야 할 요소들과 설계 전략을 규정하고 이를 토대로 도시재생사업의 적용예를 통해 법과 행정절차 제공자라는 개발취지에 적합한 전자매뉴얼 개념 모델을 제시한다.

한반도 괭이갈매기의 개체군 유전 구조와 희귀 CO1 유전자형의 지리적 파편화 (Population genetic structure and regional fragmentation of rare CO1 haplotypes of Black-tailed Gulls (Larus crassirostris: Laridae) in Korean Peninsula)

  • 정길상;황보연;권영수;진선덕;최성훈;김미란;최한수;박진영
    • 한국조류학회지
    • /
    • 제25권2호
    • /
    • pp.106-111
    • /
    • 2018
  • 괭이갈매기는 동북아시아에서 가장 흔한 갈매기류 중 하나이며, IUCN에 의하면 LC(Least Concern)로 분류되어 있다. 인간의 활동이 해양환경에 영향을 미친 이래 괭이갈매기는 해양 환경오염과 서식지 교란의 중요한 지표종이 되었다. 본 연구에서 괭이갈매기가 6개의 미토콘드리아 CO1 하플로타입(haplotype)이 있고, 이중 일부 희귀 haplotype은 지리적으로 제한되어 나타난다는 사실을 확인하였으며, 이러한 현상은 본 종이 멀리 분산하지 않음을 암시한다. 본 논문은 한국에서 괭이갈매기를 대상으로 한 첫번째 개체군 유전적 연구결과이며, 환경지표종으로서 모니터링과 유전학적 연구의 기초자료가 될 것이다.