• 제목/요약/키워드: 기둥축소량

검색결과 45건 처리시간 0.025초

고층 콘크리트 건물의 기둥축소량 계측연구 (Measured and Predicted Column Shortening of a Tall Reinforced Concrete Building)

  • 김원상;조한욱;오정근;염경수
    • 콘크리트학회논문집
    • /
    • 제11권3호
    • /
    • pp.161-170
    • /
    • 1999
  • The KLCC Petronas Tower 2, one of the world tallest twin reinforced concrete towers constructed in Kuala Lumpur, Malysia, was instrumented during construction for the measurement of vertical time-dependent deformation of columns and corewall. Field measurements were made by means of vibrating wire strain gauges at the corewall, tower and bustle perimeter columns at selected floor levels of the building. Parallel to this observation, laboratory tests were performed on concrete cylinders made in the field in order to obtain the variations of concrete compressive strengths, elastic moduli, strains of creep and shrinkage with time. Monitored vertical deformations are in a good agreement with the prediction based on actual construction sequence and concrete properties from laboratory tests, as well as the analytical results reflected in actual column compensation of the building.

나선철근 간격에 따른 중공 원형 RC 기둥의 파괴거동 (Failure Behavior of Hollow Circular RC Column According to the Spacing of Spirals)

  • 고성현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권6호
    • /
    • pp.46-55
    • /
    • 2016
  • 형상비(M/VD, shear span-depth ratio)가 4.5인 축소모형의 원형기둥 실험체 3개를 제작하였다. 철근콘크리트 기둥 실험체의 단면은 원형이고 중공단면으로 제작되었다. 철근콘크리트 기둥 실험체의 단면 지름은 400 mm, 중공 지름은 200 mm이다. 일정한 축력 하에서 반복하중을 가력하는 준정적 실험을 수행하였다. 실험체의 주요변수는 횡방향철근비이다. 모든 실험체의 횡방향 나선철근 체적비는 소성힌지 구간에서 0.302~0.604%의 값을 갖는다. 이 값은 도로교설계기준에서 요구하는 최소 심부구속철근 요구량의 45.9~91.8%에 해당하며, 이는 내진설계가 되지 않은 기존 교각이나 내진설계개념으로 설계되는 교각을 나타낸다. 본 연구의 최종목적은 실험적 기초자료의 제공과 함께 성능단계별 균열, 철근의 항복, 파단 등 정량적 수치와 경향을 제공하기 위한 것이다. 본 논문에서는 실험결과를 통해 분석된 실험변수에 따른 교각의 파괴거동, 강도저감거동, 변위연성도에 대해 중점적으로 기술하였다.

잠실제2롯데월드용 고강도 콘크리트 크리프 및 건조수축 실험결과 및 예측결과 비교분석 (Creep and Shrinkage Strain and Comparative Analysis Between Concrete Test and Experimental Results of Lotte Super Tower)

  • 차한일;문형재;석원균;박순잔;이주호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.309-310
    • /
    • 2009
  • 본 연구는 잠실제2롯데월드 초고층 건축 프로젝트의 기둥축소량에 필요한 첫 번째 단계인 재료연구(일명 콘크리트 테스트 프로그램)의 일환으로 진행되고 있다. 현재까지 18개월간의 크리프 및 건조수축 측정결과가 확보되어 있으며 이에 대한 강도와 하중재령별로 분석을 실시하였고 추가적으로 회기분석을 실시하여 예측모델식에 따른 유도식을 제안하였다. 비교분석 시 사용된 예측 모델식은 ACI209R Model, Bazant-Baweja B3 Model, CEB MC99 Model, 및 GL2000 Model 등과 같이 네 가지 의 모델식을 활용하였다. 결과분석항목은 실무에서 활용되고 있는 전체 건조수축 변형과 단위 응력당 전체 크리프 변형(Compliance)에 대해서 실시하였다.

  • PDF

고강도 콘크리트의 섬유 혼입에 따른 크리프 특성 분석에 관한 연구 (An Analytic Study on the Creep Properties for Fibers Mixed of High Strength Concrete)

  • 박희곤;권해원;이보형;배연기;이재삼;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.81-85
    • /
    • 2009
  • In the recent years, the high strength concrete has increasingly been used according to extending market of tall buildings. However, Ministry of Land, transport and Maritime Affairs was established by law with an alternative plan after June 2008 because of the weakness of high strength concrete accompanied spalling phenomena in fire. The mix design of concrete has to properly meet standards which are the spalling resistance of concrete and limited temperature of steel reinforcement. The fire proof concrete mixed fiber has widely been used to meet spalling safety on the many construction sites, the most researches about the fire proof concrete mixed fiber had being carried out focused on fire resistance, compressive strength and cast in place of concrete. But the most important thing is column shortening used the fire proof concrete within the vertical members. In this paper, the fire proof concrete filled spalling safety standards was experimented by required material when the column shortening is revised between normal concrete and fire proof concrete mixed fiber and then the results have done a comparative analysis. Also, The paper aimed to indicate a basic data for revision of column shortening of fire proof concrete.

  • PDF

철근콘크리트조 초고층건물의 3차원 시공단계 해석 및 시공중 변형 계측 (Three Dimensional Construction Stage Analysis and Deformation Monitoring of a Reinforced Concrete Highrise Building)

  • 정대계;유은종;하태훈;이성호
    • 한국전산구조공학회논문집
    • /
    • 제27권6호
    • /
    • pp.573-580
    • /
    • 2014
  • 본 논문에서는 현재 시공중인 58층의 철근콘크리트조 고층건물에서 진동현식게이지를 통해 계측된 기둥의 축방향 변형률과 레이져 스캐닝을 통해 구한 횡변위를 3차원 시공단계해석에 의한 예측치와 비교하였다. 예측치는 ACI 209와 PCA의 재료모델식, PCA report의 축소량 산정알고리즘을 3차원 구조해석 프로그램으로 개발한 ASAP을 사용하여 구하였다. 비교결과 평면의 중앙부 기둥의 축방향 변형율 계측치는 시공단계 해석치와 거의 유사한 결과를 나타내었으나 각 모서리에 두 개씩 배치된 기둥의 경우 비교적 큰 오차를 나타내었다. 레이져 스캐닝에 의한 횡변위 계측결과는 해석결과와 유사한 경향을 보였으나 층당 계측치가 큰 변동을 나타내므로 향후 이를 해결하기 위한 계측 및 데이터 처리기법이 요구된다.

고층건물 기둥의 부등축소량 예측 및 시공오차 보정에 관한 연구 (Prediction and Compensation of Differential Column Shortening in High-Rise Building Structures)

  • 조창휘;송진규;이현호;조석희
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.258-266
    • /
    • 1996
  • The purpose of this study is to make a reasonable correction in construction stage through exact prediction of long-time differential column shortening that occurs in the high-rise RC building. For this, a self-developed program adopted PCA code is used to predict differential column shortening with sequential loading process. Using this program, the amount of the different column shortening of Amatapura Apartment in Indonesia is predicted and the effect is analyzed. From the result, the major factor affecting the shortening amount in columns is elastic strain and the effect of shrinkage is very small rather than creep. And maximun differential column shortening is appeared near the middle of the building.

  • PDF

52층 아마타푸라 아파트의 기둥 부등축소량 예측 및 보정에 관한 연구 (Prediction and Compensation of Differential Column Shortening in 52 story Amatapura Apartment Building)

  • 조석희;송진규;정하선;이상순;이태규;김진근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회 논문집(I)
    • /
    • pp.397-402
    • /
    • 1998
  • The objectives of this paper are to estimate differential column Shortening and to determine appropreate compensation amount in 52 story Amatapura Apartment in Indonesia. for this, a computer program based on PCA and CEB-FIP code is developed. The results show that Elastic and Creep strain are the main factors of column shortening and the maximum differential shortening is appeared near the middle of the building height. The results between field survey and estimation have some difference, the most influential factor of the difference can be lateral restraints provided by horizontal members, which cannot be handled in this developed program. Hence introducing the modification factors from various field survey, this program can be used properly in design and construction procedures.

  • PDF

재령보정유효탄성계수법에 의한 합성기둥 축소량 해석 (Column Shortening Analysis of Composite Columns by Age-adjusted Effective Modulus Method)

  • 김한수;김재건;김도균
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.490-495
    • /
    • 2006
  • The analysis method proposed by PCA is widely used in calculating the column shortening of reinforced and composite columns of a tall building. However, residual creep factor which relates creep strain of reinforced concrete to creep strain of plain concrete is based on Rate of Creep Method (RCM) which has theoretical defects and is considered obsolete. In this paper, a new equation for the residual creep factor based on Age-adjusted Effective Modulus Method (AEMM) which is considered exact and better than RCM is proposed. The residual creep factor by RCM is found to be higher than one by AEMM, which means current PCA method overestimates the shortening of a reinforced concrete column. By using the residual creep factor by AEMM, more exact column shortening of a tall building can be obtainable with a simple modification to PCA method.

  • PDF

고층건물 기둥 부등축소량의 최적보정기법 정식화 (Formulation of an Optimal Compensation Method for Differential Column Shortening in Highrise Buildings)

  • 김기봉;박효선
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.370-377
    • /
    • 1999
  • Differential shortenings of columns in a highrise building must be considered in the design process to avoid unexpected damages in structural and nonstructural elements. While research activity has been reported in the literature on the development of estimation algorithms or prediction procedures of elastic and inelastic column shortenings, no algorithms or methods for compensation of differential shortenings. In this paper a compensation method for differential column shortenings in a high-rise is formulated as an optimization problem The simulated annealing algorithm is used to find optimal solutions. The performance of the proposed method is presented by using the well known examples developed by PCA.

  • PDF

Creep과 Shrinkage를 고려한 초고층구조물 비선형 시공단계 해석 (Analysis of the Nonlinear Staged Construction in Tall Buildings Considering the Creep and Shrinkage)

  • 박태준;박학길
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2010년도 정기 학술대회
    • /
    • pp.742-745
    • /
    • 2010
  • 본 논문은 초고층구조물의 해석방법으로 탄성변형과 아울러 시간의존성을 가진 크리프와 건조수축에 의한 비탄성변형을 고려한 비선형 시공단계 해석법을 제시한다. 기존의 초고층구조물 해석에서 주로 행하는 기둥 축소량 해석은 실무자의 경험과 프로그램을 통한 간략화에 맞추어져 있다. 이는 실제 시공 시 발생하는 구조해석 요소들을 충분히 반영하지 못하여 계산 값과 실제 값 사이에 오차가 발생된다. 비선형 시공단계 해석은 실제 시공 때 발생되는 해석변수들을 고려한 단계별 해석의 수행이 가능하며, 시간의 의존성을 가진 creep과 shrinkage의 효과를 함께 고려하여 일괄해석의 문제점을 구조해석 단계에서 실제상황에 가까운 해석을 가능하게 할 수 있다. 이를 위해 시공단계해석이 가능한 범용 프로그램을 이용한 50층 규모의 3차원 골조 프레임 모델 예제 해석을 통하여 기존 해석법들과의 비교, 분석으로 시간의 의존성을 고려한 시공단계해석의 필요성을 제시한다. 본 논문에는 범용프로그램인 SAP2000(ver.14)와 CEB-FIP모델 코드를 사용 하였다.

  • PDF