• Title/Summary/Keyword: 기둥내진보강

Search Result 164, Processing Time 0.024 seconds

Seismic Retrofit of RC Exterior Beam-Column Joints Strengthened with CFRP (CFRP를 이용한 비내진 철근콘크리트 외부 보-기둥 접합부의 내진 보강)

  • Kim, Min;Lee, Ki-Hak;Lee, Jae-Hong;Woo, Sung-Woo;Lee, Jung-Weon
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.6 s.96
    • /
    • pp.729-736
    • /
    • 2006
  • It has been shown that many Reinforced Concrete(RC) structures designed without seismic details have experienced brittle shear failures in the beam-column joint area and resulted in large permanent deformations and structural collapse. In this study, experimental investigations into the performance of exterior reinforced concrete beam-column joints strengthened with the carbon fiber-reinforced polymer(CFRP) under cyclic loading were presented. The CFRP has been applied by choosing different combinations and locations to determine the effective way to improve structural performances of joints. Eight beam-column joints were tested to investigate behaviors of each specimen under cyclic load and to compare performances of seismic retrofit. According to the experimental study, the retrofit strengthened with the CFRP provides significant improvements of flexural capacity and ductility of beam-column joints originally built without seismic details.

Earthquake-Resistant Capacity of RC Columns Retrofitted by Fiber-Steel Composite Plate (복합판으로 보강된 철근콘크리트 기둥의 내진성능연구)

  • Park Tae-Man;Park Seong-Min;Hong Hyeok-Jun;Kang Gyeong-Soo;Yoon Jeong-Bae
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.1 s.85
    • /
    • pp.113-120
    • /
    • 2005
  • The purpose of this study is to investigate the strength and ductility improvement of columns retrofitted by steel-fiber composite plate. Test specimens strengthened by three different materials - steel plate(SP), carbon fiber sheet(CF) and fiber-steel composite plate(CP) - were tested under cyclic lateral load with a constant axial load equal to $20\%$ of the axial compression capacity. The structural capacity of composite plate was good or better than that of other retrofitting materials. Test results from all retrofitted specimens showed that considerably higher retrofitting amount was required for strength enhancement. The ductility of retrofitted columns by composite plate was fairly improved. Also, energy ductility ratio was more effective than displacement ductility ratio for ductility estimation of retrofitted column.

Static Experiment of Reinforced Concrete Frame Retrofitted with Steel Damper System (강재댐퍼시스템으로 내진보강된 철근콘크리트 골조의 정적가력실험)

  • Baek, Eun Rim;Lee, Sang Ho;Oh, Sang Hoon;Kim, Jae Bong
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.90-90
    • /
    • 2011
  • 최근 전 세계적으로 지진의 발생 빈도가 증가하며 그 규모도 점차 커지는 경향을 보이고 있다. 대형지진의 발생 시 저층 구조물의 붕괴로 인한 인명 및 사회, 경제적 피해가 두드러짐에 따라 기존 저층 구조물의 내진보강기법에 관한 연구가 활발히 진행 중인 추세이다. 우리나라의 경우 강도증가형 내진보강공법이 주를 이루고 있어 다양한 내진보강기법의 개발 및 적용이 필요한 실정이다. 따라서 본 연구에서는 지진입력하중 저감형 내진보강기법으로서 강재댐퍼시스템을 제안하여 구조적 성능을 파악하고, 이를 적용한 보강 실험체와 비보강 실험체를 제작하여 정적가력실험을 통하여 그 성능을 비교하였다. 제안된 강재댐퍼시스템은 입력에너지를 소산시키는 내부의 슬릿형 댐퍼와 이를 지지하는 기둥 및 외부 프레임으로 구성되며, 내부 댐퍼는 먼저 항복하여 에너지를 소산시키기 위하여 지지기둥 및 프레임에 사용된 강재보다 강성 및 강도가 적게 계획되었다. 강재댐퍼의 성능실험 결과, 비교적 안정적 거동을 하며, 강성과 강도 및 에너지 흡수능력이 우수하게 나타났다. 보강 및 비보강 실험체의 골조는 기존 학교 건축물의 표준도면을 기준으로 하여 골조의 일부를 대상으로 60% 축소율을 적용하여 계획하였으며, 보강 실험체는 미리 제작된 강재댐퍼시스템을 골조 내에 설치하여 에폭시 주입법으로 부착시공 하였다. 보강 및 비보강 골조 실험체의 정적가력 실험결과 비보강 실험체는 기둥의 휨 항복 후 변형의 증가에 따라 휨 및 전단 균열이 증가하면서 최종적으로 기둥이 전단파괴 되었으며, 보강 실험체는 비보강 실험체에 비하여 기둥 및 보의 균열이 적고, 골조에 골고루 분포되어 파괴 규모가 감소하였다. 최대 강도면에서 보강 실험체는 비보강 실험체에 비하여 약 3.4배 우수하였으며, 초기강성은 약 7배 가량 유리한 것으로 평가되어 제안된 강재댐퍼시스템이 강도면에서 우수한 성능을 나타냄을 알 수 있었다. 또한 두 실험체의 기둥 주근 및 띠철근의 변형률을 비교한 결과, 비보강 실험체는 대부분의 철근이 항복하여 큰 변형을 일으킨 반면, 보강실험체에서는 철근의 항복현상이 나타나지 않았고 댐퍼가 항복을 하면서 큰 변형을 일으켰다. 이를 통해 지진하중 입력 시 댐퍼에서 입력 에너지를 흡수하여 큰 하중을 부담하며, 기존의 구조부재에는 입력 에너지가 낮아 손상이 보다 적게 발생함을 확인하였다.

  • PDF

Seismic Retrofit of School Facilities Using Rapping and Attaching Composite Material (부착 및 래핑형 복합소재를 이용한 학교시설의 내진보강)

  • Park, Choon-Wook;Kim, Dong-Hwi;Kwon, Min-Ho;Choi, Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.2
    • /
    • pp.135-142
    • /
    • 2014
  • In paper after the strong earthquake of recently the Korea neighborhood, the Korean government survey show that the 86% of school buildings in Korea are in potential damage risk and only 14% of them are designed as earthquake-resistance buildings. Earthquake Reinforcing projects of school have been a leading by the ministry of education, however their reinforcing methods done by not proved a engineering by experiment which results in uneconomical and uneffective rehabilitation for the future earthquake. An experimental and analytical study have been conducted for the shear reinforcing method of RC beam by axis and horizontal axis load using attaching composite beam. Based on the previous research, in this study, design examples are given to show the performance evaluation for the column reinforcing of old school buildings using nonlinear analysis is going to be conducted and strengthening method is going to be on the market after their performance is proved by the test.

Numerical Study on the Estimation of Surface Constrained Pressure for Ductile Behavior of RC Columns (RC 기둥의 연성거동을 위한 표면구속응력 산정에 관한 해석적 연구)

  • Kim, Kyeong-Min;Lee, Su-Young;Kim, Geon-Woo;Kwon, MinHo;Kim, JinSup
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.3
    • /
    • pp.48-56
    • /
    • 2021
  • Due to the recent earthquake that has occurred worldwide, interest in seismic reinforcement of structures is increasing. In order to improve the seismic performance of the structure, the seismic reinforcement of the column should be made. Various seismic retrofit methods are being developed to improve the seismic performance of columns. In this study, in order to improve the seismic performance of RC columns, an numerical study was conducted to evaluate the seismic performance of the columns by applying a surface constrained pressure. For the numerical study, the experimental study on the column was used, and the failure shape and behavior characteristics of the experimental results and the numerical results were compared. As a result of the numerical study, the ductile behavior of the RC columns occurred according to the strength of the surface constraining stress. In addition, ductile behavior occurred almost constant above a certain surface constrained pressure. Compared with the numerical results and the experimental results, he reinforcing effect of the used seismic reinforcement of the column in experimental study was compared with the value of the surface constrained pressure for the RC column, and the seismic reinforcing effect was examined as the surface constrained pressure value for the RC column. In conclusion, in this work, surface constrained stress and constrained strength for ductile behavior of RC columns are derived. Based on the results derived, it is believed that it can be used as basic data on the review of seismic design methods and seismic performance complementary effects using ductile behavior induction of RC columns.

Study on Seismic Performance of RC Column with Super-Flexibility Membrane (고연성재 보강 철근콘크리트 기둥의 내진성능 연구)

  • Lee, Weon-Cheol;Yhim, Sung-Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.1-12
    • /
    • 2013
  • This study presents the evaluations of seismic performance and displacement ductility for two types of RC columns: existing RC column without SFM (Super Flexibility Membrane) and CSF (RC columns strengthened with SFM). After they are analyzed by the experiment as well as FEM, crack patterns and load-displacement curve of CSF by the former are shown to similar to those of CSF by the latter. The flexural cracks are dominant in CSF, whereas shear cracks in CNF (existing RC column without SFM). Displacement ductility of CSF is shown significantly to increase as well as ultimate displacement, compared to those of CNF. Therefore CSF can be replaced to CNF in order to increase the seismic performance and displacement ductility.

An Experimental Study of Seismic Retrofit on the Viaduct Bridge of Rail Transit (철도 고가교 기둥의 내진성능에 관한 실험적 연구)

  • Kim, Jinho;Shin, Hongyoung;Park, Yeonjun;Hur, Jinho
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.6
    • /
    • pp.616-622
    • /
    • 2012
  • Earthquake damage of viaduct bridge of railroad may give rise to social loss due to transport restrictions greater than cost of structural recovery. Therefore, viaduct bridge of railroad should have ensure adequate seismic performance. But, results of seismic performance evaluation, many of seismic retrofit was required. In this study, five scale models of columns were made and four of them were reinforced by HT-A(HyperTex & perforate Aluminum) which is improved than existing method. Testing the columns by constant axial load and cyclic lateral displacements, seismic performance of columns has been verified from the result of evaluating the stiffness, ductility and energy dissipation capacity.

Improvement and Evaluation of Seismic Performance for Reinforced Concrete Beam-Column Joints Using High Performance Embedded FRP (고성능 FRP를 활용한 철근콘크리트 보-기둥 접합부의 내진 성능 평가 및 개선)

  • Ha, Gee-Joo;Shin, Jong-Hack;Kang, Hyun-Wook
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.3
    • /
    • pp.385-392
    • /
    • 2011
  • In this study, experimental research was carried out to evaluate and improve the seismic performance of reinforced concrete beam-column joint regions using strengthening materials (steel plate, carbon fiber sheet, and embedded carbon fiber rod) in existing reinforced concrete buildings. Six specimens of retrofitted beam-column joints are constructed using various retrofitting materials and tested for their retrofit performances. Specimens designed by retrofitting the beam-column joint regions (LBCJ series) of existing reinforced concrete building showed a stable mode of failure and an increase in load-carrying capacity due to the effect of crack control at the time of initial loading and confinement from retrofitting materials during testing. Specimens of LBCJ series, designed by the retrofitting of FRP in reinforecd beam-column joint regions increased its maximum load carrying capacity by 26~50% and its energy dissipation capacity by 13.0~14.4% when compared to standard specimen of LBCJC with a displacement ductility of 4.

Evaluation of Lateral Strength and Ductility of Velcro Reinforced RC Columns with Finite Element Analysis (유한요소해석을 통한 벨크로로 보강된 RC 기둥의 횡방향 강도 및 연성 능력 평가)

  • Kim, Sang-Woo;Kim, Kyeong-Min;Kim, Geon-Woo;Lee, Su-Young;Kim, Jin-Sup
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.4
    • /
    • pp.12-19
    • /
    • 2021
  • Recently, with frequent earthquakes around the world, research on seismic design and seismic reinforcement of reinforced concrete facilities has been actively conducted from earthquakes. In particular, columns, which are compressed members of reinforced concrete structures, are vulnerable to lateral forces caused by earthquakes, so an appropriate seismic reinforcement method is required. Therefore, this study intended to develop Velcro seismic reinforcement method that is quick and easy to construct. For the development of Velcro seismic reinforcement, the adhesion and tensile strength of the existing industrial velcro was improved. A direct tensile test was also conducted to compare the tensile performance of the newly-developed velcro seismic reinforcement to industrial one. In addition, numerical analysis was performed to predict the seismic performance of RC columns reinforced by industrial and newly-developed velcro. Based on the analysis results, the strength and ductility of the non-seismic and velcro-reinforced RC column were reviewed. The analysis confirmed that both the strength and ductility of non-seismic RC columns reinforced by industrial and newly-developed velcro increased, but the seismic performance of the newly-developed Velcro reinforcement is better than that of industrial velcro.

Numerical Study for Seismic Strengthening of RC columns Using Fiber Reinforced Plastic Composite (기둥의 내진성능 향상을 위한 섬유보강 복합체의 적용성에 대한 해석적 연구)

  • Chang, Chun Ho;Kwon, Min Ho;Kim, Jin Sup;Joo, Chi Hong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.3
    • /
    • pp.117-127
    • /
    • 2012
  • As increasing number of large-size earthquake around Korean peninsula, many interests have been focused to the earthquake strengthening of existing structures. Fiber reinforced plastic composite material is one of strengthening material widely used to increase seismic performance of structures. It should have high stiffness as well as large ductility to provide best strengthening result. Thus selection of stiffener and fiber in composite is of important. In this study, the optimal combination of fiber and stiffener is selected with variety of tensile tests. In order to investigate performance of chosen composite material, several finite element analyses are performed with proposed FRP composite material for existing RC columns. It is discussed that the seismic performance of strengthened columns through the load-displacement relationship. It is shown that the proposed composite material can increase the strength as well as ductility of exiting RC columns.