• Title/Summary/Keyword: 기능성 근시

Search Result 9, Processing Time 0.026 seconds

Improvement effect of Functional Myopia by Using of Vision Training Device(OTUS) (Vision Training Device(OTUS)적용에 따른 기능성 근시의 개선 효과)

  • Park, Sung-Yong;Yoon, Yeong-Dae;Kim, Deok-Hun;Lee, Dong-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.2
    • /
    • pp.147-154
    • /
    • 2020
  • This study is about the development of ICT-based wearable devices for vision recovery that can cause functional myopia improvement through accommodation training. Vision Training Device(OTUS) is a head mount type wearable device, which naturally stimulates the contraction and relaxation of the ciliary muscles of eye. Users can conduct customized vision training based on personal vision information stored through the device. In the experiment, the effects of improvement of the symptoms by the accommodation training were compared and analysed for the two groups (16 comparative group and 16 accommodation training group) after causing functional myopia. The result showed the functional myopia improved average 0.44D±0.35 (p<0.05) at the accommodation training group compared to the comparative group. This study proved the effectiveness of vision training device(OTUS) on functional myopia, but further clinical trials are judged necessary to prove the possibility of long-term control of the functional myopia.

The Accommodative Lag and Refractive Error in Early Adults (초년 성인의 굴절이상과 조절래그 분포의 연관성)

  • Baarg, Saang-Bai;Jeong, Youn Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.59-65
    • /
    • 2012
  • Purpose: The purpose of this study was to determine the distribution and correlation of accommodative lag with refractive error. Method: We had tested the clinical refraction and the accommodative lag in clinically normal 49 young adults (total 98 eyes) aged 18 to 25 years without abnormal binocular function. Monocular and binocular accommodative lag were tested with 0.50 D cross-cylinder lens and near vision test chart which had cross-hairs after full correction of LogMAR visual acuity over 0.05. Results: There was no statistical differences in monocular accommodative lag between right ($0.64{\pm}0.64$ D) and left eye ($0.63{\pm}0.64$)(p=0.858). The accommodative lag of male was higher than female and the range of the value was broader than female in binocular accommodative lag (p=0.015). The wider the inter-pupillary distance was, the higher the accommodative lag was (p=0.003). However, there were no differences with age (p=0.800) and dominant eye (p=0.402). The ranges of accommodative lag of low, middle, and high myopia were 0.75 ~ -0.25 D, 1.25 ~ -0.50 D, and 1.50 ~ -0.75 D, respectively, and the regression was 'y = -0.03953x+0.09205'. Conclusions: These data suggest that clinically normal young adults with high amounts of refractive error have more variable accommodative lag and increased spherical equivalent refraction.

An Analysis on Conceptual Sequence and Representations of Eye Vision in Korean Science Textbooks and a Suggestion of Contents Construct Considering Conceptual Sequence in the Eye Vision (초 . 중등학교 과학 교과서에서의 시각(eye vision) 개념의 연계성과 표현 방식 분석 및 연계성을 고려한 시각 개념 구성의 한 가지 제안)

  • Kim, Young-Min
    • Journal of The Korean Association For Science Education
    • /
    • v.27 no.5
    • /
    • pp.456-464
    • /
    • 2007
  • The aims of this research are to analyze the representations and conceptual sequence of eye vision in Korean science textbooks and to suggest a contents construct about eye vision where the conceptual sequence is considered. Research method was literature review, and the literatures that were used for analysis were the 7th Korean science curriculum which was revised in 1997, and the science and physics textbooks developed based on the 7th Korean science curriculum. The research results are as follows: 1) Although the science curriculum seems to have no problem on sequence in the eye vision concepts, the science and physics textbooks based on the curriculum reveal problems on the sequence in the eye vision concepts; 2) Some Korean science textbooks explain retinal image formation according to the Alhazen's idea, except in inverse image; 3) Some Korean science textbooks explain about the reasons of near- and far-sightedness without consistency between the textbooks for 7th and 8th grade students; 4) A few Korean science textbooks give an inappropriate explanation about the principle of eye sight correction by eye glasses; 5) According to the analysis result, the concepts related to eye vision should be presented in the order of explanation about light refraction phenomena, image formation process by convex lens, structure of human eye and retinal image formation process, correction of eye sight using lens.

Time-dependent Changes of Visual Acuity After Alcohol Ingestion (음주 후 시간경과에 따른 시력의 변화)

  • Kim, Sang-Yoeb;Lee, Sun Haeng;Moon, Byeong-Yeon;Yu, Dong-Sik;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.59-62
    • /
    • 2008
  • Purpose: This study was designed to investigate the time-dependent changes of visual acuity after alcohol ingestion. Methods: Both the subjective and objective refraction, distant contrast sensitivity, and three needle tests were carried out at 1 and 3 hours after alcohol ingestion. Results: It was found that the degree of myoptization increased as the blood alcohol level increased in the range of average -0.25D ~ -0.35D when tested 1 and 3 hours after alcohol ingestion. Under the same test conditions the increase in blood alcohol resulted in the reduction in the function of dynamic stereopsis. However, the variation in contrast sensitivity was found to be insignificant for all spatial frequencies. Conclusions: The optician has to be well aware of the fact that alcohol could affect the visual acuity and functional tests, therefore inquiring of the alcohol ingestion prior to visual test can be necessary.

  • PDF

Design and Implementation of the Quantity Surveying and Shop Drawing System for Structures (BIM 기반 골조 물량산출 및 도면생성 모듈의 설계와 구현)

  • Lee, Byung-Kwon;Kim, Chee-Kyeong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.132-135
    • /
    • 2011
  • 최근 설계 단계에서 설계품질 향상과 시공 단계에서 비용 절감을 효과를 기대하며 3차원 BIM 관련 기술에 대한 관심이 높아가고 있으며, 또한 부분적으로 기술 도입 효과가 나타나고 있다. BIM 기술은 크게 BIM 도구를 활용하여 설계정보를 디지털화하는 모델링 단계 기술과 BIM 모델로부터 설계 정보를 추출하여 업무 진행에 필요한 형태로 가공, 변환하는 정보 활용 기술로 구분하여 생각할 수 있다. BIM 기술에 대한 근자의 높은 관심에도 불구하고 실제 현장에 적용되어 가시적인 성과를 내는 데에 한계를 보이고 있는 이유 중 하나로 후자의 정보 추출 및 활용 기술의 범위와 완성도의 한계를 들 수 있다. 즉 많은 노력을 통하여 BIM 모델을 구축하더라도 이를 기반으로 물량산출, 도면 생성 등 가장 기본적인 업무조차도 현장에서 바로 사용할 수 있는 수준의 기능이 제공되고 있지 않다. 본 연구에서는 건축 골조를 대상으로 3차원 골조 모델을 이용하여 골조 물량, 특히 정확한 물량산출이 상대적으로 어려운 철근에 대하여 철근의 이음, 정착 등이 고려된 실행물량을 산출할 수 있는 시스템을 설계하고 구현하였다. 또한 3차원 모델을 기반으로 철근 배근시공도와 가공일람표를 관련 기준에 따라 정확히 자동 작성함으로써 골조공사가 효율적으로 수행되고, 특히 정확한 이음 및 정착과 가공 계획을 통하여 철근 손실율을 최소화함이 기대된다. 본 논문에서는 이러한 BIM 기반 골조 물량산출 및 도면생성 시스템과 관련하여 주요 시스템 설계 내용과 구현 결과에 대하여 기술한다.

  • PDF

Speed Optimization Design of 3D Medical Image Reconstruction System Based on PC (PC 기반의 3차원 의료영상 재구성 시스템의 고속화 설계)

  • Bae, Su-Hyeon;Kim, Seon-Ho;Yu, Seon-Guk
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.189-198
    • /
    • 1998
  • 3D medical image reconstruction techniques are useful to figure out complex 3D structures from the set of 2D sections. In the paper, 3D medical image reconstruction system is constructed under PC environment and programmed based on modular programming by using Visual C++ 4.2. The whole procedures are composed of data preparation, gradient estimation, classification, shading, transformation and ray-casting & compositing. Three speed optimization techniques are used for accelerating 3D medical image reconstruction technique. One is to reduce the rays when cast rays to reconstruct 3D medical image, another is to reduce the voxels to be calculated and the other is to apply early ray termination. To implement 3D medical image reconstruction system based on PC, speed optimization techniques are experimented and applied.

  • PDF

Graphic Method of Visual Analysis and Norms Determination for the Far Distance Phoria (원거리사위별 그래프 분석과 표준값 결정)

  • Joo, Seok-Hee;Park, Seong-Jong;Sim, Hyun-Seog
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.193-200
    • /
    • 2006
  • We investigated the visual analysis of the far distance phoria for 83 subjects who have emmetropia or myopia eyes, using the graphic method, and determined new norms. We got the following results from these experiments. 1. The measured norm of far distance phoria is $1.12{\Delta}$, exophoria, the that of near distance phoria is $0.50{\Delta}$, exophoria, the that of negative relative convergence at far distance(N.R.C.) is ${\times}$/11/5, the that of positive relative convergence at far distance(P.R.C.) is 10/20/8, the that negative relative convergence at near distance(N.R.C.) is 11/21/5, the that of positive relative convergence at near(P.R.C.) is 10/20/8, the that of negative relative accommodation(N.R.A.) is +2.54D, and the that of positive relative accommodation(P.R.A.) is -2.60D, respectively. We know from theses results that the measured norms of far distancet phoria is higher than Morgan's norms, while those of near distance phoria are lower than Morgan's norms. 2. We also know from these experiments that Morgan's norms are closely related to A, B, and C groups and Morgan's criterion can more usefully apply to the visual analysis. 3. In Sheard's criterion and Percival's criterion, the prism prescription is occurred when the exophoria of the far-point phoria is over $7{\sim}9{\Delta}$, and the esophoria of that is over $4{\sim}6{\Delta}$.

  • PDF

Cause Analysis in Decrease of Body Stability According to The Induced Astigmatic Blur (유발된 난시성 흐림에 의한 신체 안정성 감소의 원인분석)

  • Kim, Sang-Yeob;Yu, Dong-Sik;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.259-264
    • /
    • 2016
  • Purpose: To establish the cause of decrease in body stability and to analyze the effects on sensory organs maintaining static balance according to the induced astigmatic blur. Methods: Twenty subjects (10 males, 10 females; mean age, $23.40{\pm}2.70years$) were participated in this study. To induce myopic simple astigmatism, the axis directions of cylindrical lenses were placed $180^{\circ}$ on both eyes (with-the-rule), $90^{\circ}$ on both eyes (against-the-rule), and $45^{\circ}$ on both eyes (oblique). Cylindrical lenses of +0.50, +1.00, +1.50, +2.00, +3.00, +4.00, and +5.00 D were used to increase astigmatic blur in each astigmatism types. General stability (ST) and sway power (SP) in frequencies by each sensory organs were analyzed using the TETRAX biofeedback system. Results: ST in the all astigmatism types were raised with increase of astigmatic blur compared to full corrected condition, but a significant difference only showed in the induced oblique astigmatism. According to the results of correlation analysis between ST and SP in the each frequencies with increase of astigmatic blur, the causes of increased ST in the induced oblique astigmatism showed to have a high correlation in order of somatosensory system (high-medium frequency), central nervous system (high frequency), peripheral vestibular system (low-medium frequency), and visual system (low frequency). Conclusions: The visual information by uncorrected oblique astigmatism may disturb the normal functions of all sensory organs maintaining body balance, consequently, the body stability can be reduced. Therefore, optimal correction of astigmatism can play an important role for reducing the instability of body balance.

A Study on the Relationship Between the Off-Axis Cylinder and Corrected Vision of Astigmatism (난시안의 교정축 이탈과 교정시력과의 관계 연구)

  • Kim, Jung Hee;Kang, Sue Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.83-87
    • /
    • 2007
  • This study was classified and compared astigmatism's refractional abnormal degrees with visual acuity state of full correction which turned on axises of only 5 degree, 10 degree, and 15 degree. Subjects of this study were 57 college students (114 eyes) who had neither eye diseases nor binocular abnormality, were from their twenties to fifties, with myopia. It appeared that 30.8% of subjects who had astigmatism wore glasses with wrong axis of astigmatism. After accurate correction of the visual acuity and degrees of astigmatism, when we moved to corrected axises at 5 degree, 10 degree, 15 degree, failure of visual acuity with one line or more were 56.1%, 84.2%, 93.8%, respectively. When we comapre the completely-corrected visual acuity with the visual acuity with dricted axes, the bigger the width of visual acuity's weakness was the bigger the drifted angle. The change of normal visual acuity according to drifting angle of corrected axises of astigmatism, when we compared with full correction, appeared 0.94 in 5 degree, 0.87 in 10 degree, and 0.79 in 15 degree. Drift of 5 degree from fully corrected axis, corresponded to difference of visual acuity about one line, drift of 10 degree to 1.8 line difference of visual acuity, and drift of 15 degree about to 2.6 line difference. Through this study, we were sure that, in the case of drifting away from the right axis of astigmatism, it lead to visual weakness and asthenopia. Therefore we darely advise that optometrists should make mistake of axis least by confirming accucacy of corrected axis after despensing of spectacles of astigmatism.

  • PDF