• Title/Summary/Keyword: 기기

Search Result 18,130, Processing Time 0.042 seconds

Effect of abutment superimposition process of dental model scanner on final virtual model (치과용 모형 스캐너의 지대치 중첩 과정이 최종 가상 모형에 미치는 영향)

  • Yu, Beom-Young;Son, Keunbada;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.203-210
    • /
    • 2019
  • Purpose: The purpose of this study was to verify the effect of the abutment superimposition process on the final virtual model in the scanning process of single and 3-units bridge model using a dental model scanner. Materials and methods: A gypsum model for single and 3-unit bridges was manufactured for evaluating. And working casts with removable dies were made using Pindex system. A dental model scanner (3Shape E1 scanner) was used to obtain CAD reference model (CRM) and CAD test model (CTM). The CRM was scanned without removing after dividing the abutments in the working cast. Then, CTM was scanned with separated from the divided abutments and superimposed on the CRM (n=20). Finally, three-dimensional analysis software (Geomagic control X) was used to analyze the root mean square (RMS) and Mann-Whitney U test was used for statistical analysis (${\alpha}=.05$). Results: The RMS mean abutment for single full crown preparation was $10.93{\mu}m$ and the RMS average abutment for 3 unit bridge preparation was $6.9{\mu}m$. The RMS mean of the two groups showed statistically significant differences (P<.001). In addition, errors of positive and negative of two groups averaged $9.83{\mu}m$, $-6.79{\mu}m$ and 3-units bridge abutment $6.22{\mu}m$, $-3.3{\mu}m$, respectively. The mean values of the errors of positive and negative of two groups were all statistically significantly lower in 3-unit bridge abutments (P<.001). Conclusion: Although the number of abutments increased during the scan process of the working cast with removable dies, the error due to the superimposition of abutments did not increase. There was also a significantly higher error in single abutments, but within the range of clinically acceptable scan accuracy.

Development of Analytical Method for Ergot Alkaloids in Foods Using Liquid Chromatoraphy-Tandem Mass Spectrometry (LC-MS/MS를 이용한 식품 중 맥각 알칼로이드 시험법 개발)

  • Chun, So Young;Chong, Euna;Lee, Bomnae;Kwon, Jin-Wook;Park, Hye Young;Kim, Sheenhee;Gang, Giljin
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.2
    • /
    • pp.158-169
    • /
    • 2019
  • Ergot alkaloids are mycotoxin produced by fungi of the Claviceps genus, mainly by Claviceps purpurea in EU. Recently obtained informations indicates necessity for control the ergot in imported grains. Recent occurrence data of ergot alkaloids from EU countries indicate the necessities of management and control these toxins from the imported grains like rye, wheat, oat etc. The aim of this study is to optimize the liquid chromatography-tandem mass spectrometry method for determination of ergot alkaloids (ergometrine, ergosine, ergotamine, ergocornine, ergocryptine, ergocristine and their epimers (-inines) from grain and grain-based food. The test method was optimized by extracting the sample with acetonitrile containing 2 mM ammonium carbonate, purification with Mycosep cartridge, and instrumental analysis by LC-MS/MS using Syncronis C18 column. The standard calibration curves showed linearity with correlation coefficents; $R^2$ >0.99. Mean recoveries ranged from 72.0 to 111.3% at three different fortified levels (20, 50, and $100{\mu}g/kg$). The correlation coefficient expressed as precision was within the range of 1.9-12.9%. The limit or quantifications (LOQ) ranged from 0.012 to $0.058{\mu}g/kg$. The developed analytical method met the criteria of AOAC Int. and CAC validation parameters like accuracy and sensitivity. As a result, it was confirmed that the test method developed in this study is suitable for the simultaneous analysis of six species of ergot alkaloid from grains and grain products.

The effects of out of hospital ACLS simulation training on the paramedic's duty ability (구급대원의 전문심장소생술 시뮬레이션훈련이 직무수행융합능력에 미치는 영향)

  • Park, Yoo-Na;Cho, Byung-Jun;Kim, Gyoung-Young
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.4
    • /
    • pp.99-106
    • /
    • 2019
  • The purpose of this study is to analyze the effects of the simulation-based professional cardiac resuscitation training on the performance of professional cardiac resuscitation performed by paramedics in the pre-hospital stage and to provide basic data for effective cardiac resuscitation. This study is an experimental study of the design before and after the control of non-equality. The subjects of this study were 16 newly recruited paramedics from K firefighting school. The simulation training program and evaluation papers used as the evaluation tool were reviewed and commented by 6 ACLS simulation experts (2 emergency medical doctor, 2 emergency medical professors, 2 KALS instructors)Respectively. The training consisted of 30 minutes of theory and 150 minutes of practical training. The lecturer first demonstrated for 5 minutes, and after training by individual debriefing after individual training, individual and team education was conducted The evaluation scale was given a 5 - point Likert scale. The SPSS 22.0 program for Windows was used. The general characteristics of the subjects were analyzed for frequency, the examination of homogeneity between the experimental group and the control group wasfulfilled by t test, and the difference test between the groups of the two groups was performed using the paired t-test. The homogeneity test was able to confirm the homogeneity between experimental group and control group. In the evaluation of six ACLS techniques, it was proven that the experimental group that received the simulation training had better performance in all aspects than the non - training control group. The following are the technical items to be performed. 1. Electrocardiogram 2. Specialized instrument 3. Treatment of fluid 4. Leadership and teamwork 5. Medical guidance 6. Evaluation during transfer. It was proved that paramedics who received simulation training were improved on their job performance ability than general lecture and training group. Therefore, if simulation training and education are applied to a student in the synthetic course or an emergency resident who is engaged in clinical practice, he / she will be able to perform his / her duties more proficiently. It is expected that emergency services provided to patients with cardiac arrest will be improved.

Comparison of the accuracy of intraoral scanner by three-dimensional analysis in single and 3-unit bridge abutment model: In vitro study (단일 수복물과 3본 고정성 수복물 지대치 모델에서 삼차원 분석을 통한 구강 스캐너의 정확도 비교)

  • Huang, Mei-Yang;Son, Keunbada;Lee, Wan-Sun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.102-109
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the accuracy of three types of intraoral scanners and the accuracy of the single abutment and bridge abutment model. Materials and methods: In this study, a single abutment, and a bridge abutment with missing first molar was fabricated and set as the reference model. The reference model was scanned with an industrial three-dimensional scanner and set as reference scan data. The reference model was scanned five times using the three intraoral scanners (CS3600, CS3500, and EZIS PO). This was set as the evaluation scan data. In the three-dimensional analysis (Geomagic control X), the divided abutment region was selected and analyzed to verify the scan accuracy of the abutment. Statistical analysis was performed using SPSS software (${\alpha}=.05$). The accuracy of intraoral scanners was compared using the Kruskal-Wallis test and post-test was performed using the Pairwise test. The accuracy difference between the single abutment model and the bridge abutment model was analyzed by the Mann-Whitney U test. Results: The accuracy according to the intraoral scanner was significantly different (P < .05). The trueness of the single abutment model and the bridge abutment model showed a statistically significant difference and showed better trueness in the single abutment (P < .05). There was no significant difference in the precision (P = .616). Conclusion: As a result of comparing the accuracy of single and bridge abutments, the error of abutment scan increased with increasing scan area, and the accuracy of bridge abutment model was clinically acceptable in three types of intraoral scanners.

An Empirical Study on Classification, Business Type, Organizational Culture on Performance of Korean IT SMEs·Venture (중소·벤처기업의 업종, 영업형태, 조직문화가 기업성과에 미치는 영향에 관한 연구: 삼원분산분석(3-way ANOVA)을 중심으로)

  • Roh, Doo-Hwan;Hwang, Kyung-Ho
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.14 no.2
    • /
    • pp.221-233
    • /
    • 2019
  • In Korea, small and medium sized domestic enterprises(SMEs) play an pivotal role in the national economy, accounting for 99.9% of all enterprises, 87.9% of total employment, and 48.3% of production. and SMEs was driving a real force of the development of national economy in many respects such as innovation, job creation, industrial diversity, balanced regional development. Despite their crucial role in the national development, most of SMEs suffer from a lack of R&D capabilities and equipments as well as funding capacity. Public R&D institutes can provide SMEs with valuable supplementary technological knowledge and help them build technological capacity. so, In order to effectively support SMEs, government and public R&D institutes must be a priority to know about the factors influencing the performance related to technology transfer and technological collaborations. In particular, SMEs are not only taking up a large portion of the national economy, but also their influence in politics and economy so strong that raising the competitiveness of small and medium-sized companies is a national policy goal that must be achieved in order to achieve sustained economic growth. For this reason, it is necessary to look specifically at the relationship between concepts such as the environment, strategy, and organizational culture surrounding the enterprise to enhance the competitiveness of SMEs. The paper analyzes 665 companies to find out which organizational culture affects their performance by classification and type of business of SMEs. This study demonstrated that when SMEs seek consistency in their external environment, strategies, and organizational structure to maintain their continued competitiveness. According to three-way analysis of variance (3-way ANOVA) indicates that classification of industries in SMEs has statistically significant main effects, but the type of business and organizational culture do not have significant effects. However, the company's organizational performance (operating profit) of SMES were found to differ significantly in comparison between groups according to classification standards of industries, and therefore adopted some parts. In addition, an analysis of the effect of interaction between the three independent variables of small and medium-sized enterprises has shown that there are statistically significant interaction effects among classification, types of business, and organizational cultures. The results shows that there is an organizational culture suitable for each industry classification and type of business of an entity, and is expected to be used as a basis for establishing promotion policies related to the incubation and commerciality of small and medium-sized venture companies in the future.

Suggested Protocol for Efficient Medical Image Information Exchange in Korea: Breast MRI (효율적 의료영상정보교류를 위한 프로토콜 제안: 유방자기공명영상)

  • Park, Ji Hee;Choi, Seon-Hyeong;Kim, Sungjun;Yong, Hwan Seok;Woo, Hyunsik;Jin, Kwang Nam;Jeong, Woo Kyoung;Shin, Na-Young;Choi, Moon Hyung;Jung, Seung Eun
    • Journal of the Korean Society of Radiology
    • /
    • v.79 no.5
    • /
    • pp.254-258
    • /
    • 2018
  • Purpose: Establishment of an appropriate protocol for breast magnetic resonance imaging (MRI) in the study of image quality standards to enhance the effectiveness of medical image information exchange, which is part of the construction and activation of clinical information exchange for healthcare informatization. Materials and Methods: The recommended protocols of breast and MRI scans were reviewed and the questionnaire was prepared by a responsible researcher. Then, a panel of 9 breast dedicated radiologists was set up in Korea. The expert panel conducted a total of three Delphi agreements to draw up a consensus on the breast MRI protocol. Results: The agreed breast MRI recommendation protocol is a 1.5 Tesla or higher device that acquires images with prone position using a breast dedicated coil and includes T2-weighted and pre-contrast T1-weighted images. Contrast enhancement images are acquired at least two times, and include 60-120 seconds between images and after 4 minutes. The contrast enhancement T1-weighted image should be less than 3 mm in thickness, less than 120 seconds in temporal resolution, and less than $1.5mm^2$ in-plane pixel resolution. Conclusion: The Delphi agreement of the domestic breast imaging specialist group has established the recommendation protocol of the effective breast MRI.

Characterization of Repeated Deactivation and Subsequent Re-activation of Photocatalyst Used in Two Alternatively-operating UV/photocatalytic Reactors of Waste-air Treating System (교대로 운전되는 두 개의 UV/광촉매반응기로 구성된 폐가스 처리시스템에서의 광촉매의 비활성화 및 재생 특성)

  • Lee, Eun Ju;Chung, Chan Hong;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.59 no.4
    • /
    • pp.584-595
    • /
    • 2021
  • In this study, the correlation between operating stages of waste air-treating system composed of two alternatively-operating UV/photocatalytic reactors, and the deactivation of photocatalyst used in each operating stage, was investigated by instrumental analysis thereon. The repeated deactivation and subsequent re-generation of photocatalyst used in the waste air treating system of previous investigation performed by Lee and Lim (Korean Chem. Eng. Research, 59(4), 574-583(2021)), were characterized on virgin photocatalyst-carrying porous SiO2 media (A4), used photocatalyst-carrying porous SiO2 media (A1, A2 and A3) collected from the corresponding photocatalytic reactor upon 1st, 2nd, and 3rd run, respectively, regenerated photocatalyst-carrying porous SiO2 media upon 1 time-run (AD1) and 3 times regenerated photocatalyst-carrying porous SiO2 media upon 3 time-runs (AD3) by instrumental analysis including BET analysis, SEM, XPS, SEM-EDS and FT-IR. As a result, the proper regeneration-temperature for deactivated photocatalyst to be regenerated several times (more than 3 times), was suggested below 200 ℃. Such temperature of deactivated photocatalyst-regeneration was almost consistent to the one, according to BET analysis, at which tiny nano-pores blocked by adsorbed ethanol-oxidative and degraded intermediates (AEODI), were regenerated to be reopened through almost complete mineralization of AEODI. In particular, the results of XPS analysis indicated an incurrence of insignificant deactivation of photocatalysis upon 1st run of UV/photocatalytic reactor (A or C) of the previous investigation. In addition, the results of XPS analysis were consistent with the experimental results of the previous investigation in that 1) deactivation of photocatalyst incurred during 2nd run of the UV/photocatalytic reactor (A or C) resulted in decreased removal efficiency, by ca. 5% and 5%, of ethanol and hydrogen sulfide, respectively, compared with its 1st run; 2) there was insignificant difference between the removal efficiencies of its 2nd run and 3rd run. Furthermore, the removal efficiencies of ethanol and hydrogen sulfide for hypothetical 4th run of photocatalytic reactor in the previous investigation, using AD3, were expected to decrease, compared with its 3rd run, by much more than those for 2nd run in the previous investigation did, compared with its 1st run.

Application of Automated Microscopy Equipment for Rock Analog Material Experiments: Static Grain Growth and Simple Shear Deformation Experiments Using Norcamphor (유사물질 실험을 위한 자동화 현미경 실험 기기의 적용과 노캠퍼를 이용한 입자 성장 및 단순 전단 변형 실험의 예)

  • Ha, Changsu;Kim, Sungshil
    • Economic and Environmental Geology
    • /
    • v.54 no.2
    • /
    • pp.233-245
    • /
    • 2021
  • Many studies on the microstructures in rocks have been conducted using experimental methods with various equipment as well as natural rock studies to see the development of microstructures and understand their mechanisms. Grain boundary migration of mineral aggregates in rocks could cause grain growth or grain size changes during metamorphism or deformation as one of the main recrystallization mechanisms. This study suggests improved ways regarding the analog material experiments with reformed equipment to see sequential observations of these grain boundary migration. It can be more efficient than the existing techniques and carry out an appropriate microstructure analysis. This reformed equipment was implemented to enable optical manipulation by mounting polarizing plates capable of rotating operation on a stereoscopic microscope and a deformation rig capable of experimenting with analog materials. The equipment can automatically control the temperature and strain rate of the deformation rig by microcontrollers and programming and can take digital photomicrographs with constant time intervals during the experiment to observe any microstructure changes. The composite images synthesized using images by rotated polarizing plates enable us to see more accurate grain boundaries. As a rock analog material, norcamphor(C7H10O) was used, which has similar birefringence to quartz. Static grain growth and simple shear deformation experiments were performed using the norcamphor to verify the effectiveness of the equipment. The static grain growth experiments showed the characteristics of typical grain growth behavior. The number of grains decreases and the average grain size increases over time. These case experiments also showed a clear difference between the growth curves with three temperature conditions. The result of the simple shear deformation experiment under the medium temperature-low strain rate showed no significant change in the average grain size but presented the increased elongation of grain shapes in the direction of about 53° regarding the direction perpendicular to the shearing direction as the shear strain increases over time. These microstructures are interpreted as both the plastic deformation and the internal recovery process in grains are balanced by the deformation under the given experimental conditions. These experiments using the reformed equipment represent the ability to sequentially observe changing the microstructure during experiments as desired in the tests with the analog material during the entire process.

Development of A Material Flow Model for Predicting Nano-TiO2 Particles Removal Efficiency in a WWTP (하수처리장 내 나노 TiO2 입자 제거효율 예측을 위한 물질흐름모델 개발)

  • Ban, Min Jeong;Lee, Dong Hoon;Shin, Sangwook;Lee, Byung-Tae;Hwang, Yu Sik;Kim, Keugtae;Kang, Joo-Hyon
    • Journal of Wetlands Research
    • /
    • v.24 no.4
    • /
    • pp.345-353
    • /
    • 2022
  • A wastewater treatment plant (WWTP) is a major gateway for the engineered nano-particles (ENPs) entering the water bodies. However existing studies have reported that many WWTPs exceed the No Observed Effective Concentration (NOEC) for ENPs in the effluent and thus they need to be designed or operated to more effectively control ENPs. Understanding and predicting ENPs behaviors in the unit and \the whole process of a WWTP should be the key first step to develop strategies for controlling ENPs using a WWTP. This study aims to provide a modeling tool for predicting behaviors and removal efficiencies of ENPs in a WWTP associated with process characteristics and major operating conditions. In the developed model, four unit processes for water treatment (primary clarifier, bioreactor, secondary clarifier, and tertiary treatment unit) were considered. Additionally the model simulates the sludge treatment system as a single process that integrates multiple unit processes including thickeners, digesters, and dewatering units. The simulated ENP was nano-sized TiO2, (nano-TiO2) assuming that its behavior in a WWTP is dominated by the attachment with suspendid solids (SS), while dissolution and transformation are insignificant. The attachment mechanism of nano-TiO2 to SS was incorporated into the model equations using the apparent solid-liquid partition coefficient (Kd) under the equilibrium assumption between solid and liquid phase, and a steady state condition of nano-TiO2 was assumed. Furthermore, an MS Excel-based user interface was developed to provide user-friendly environment for the nano-TiO2 removal efficiency calculations. Using the developed model, a preliminary simulation was conducted to examine how the solid retention time (SRT), a major operating variable affects the removal efficiency of nano-TiO2 particles in a WWTP.

Factors affecting the formation of bound 3-monochloropropane-1,2-diol in a fried snack model (유탕 과자 모델에서 결합형 3-monochloropropane-1,2-diol 생성에 영향을 미치는 요인)

  • Kang, Jun-Hyuk;Joung, Woo-Young;Rho, Hoi-Jin;Baek, Hyung-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.52 no.6
    • /
    • pp.565-572
    • /
    • 2020
  • The 3-monochloropropane-1,2-diol (3-MCPD) is a contaminant that occurs in foodstuffs in its free form as well as in its bound form. The objective of this study was to evaluate the effects of emulsifier, frying temperature, and the amounts of salt and oil on the formation of bound 3-MCPD in a fried snack model. Emulsifier affected the formation of bound 3-MCPD; furthermore, it was observed that the largest amount of bound 3-MCPD was detected in the fried snack model when glycerin esters of fatty acids were used as emulsifiers. Frying temperature also affected the formation of bound 3-MCPD, which increased significantly as the frying temperature increased from 145 to 190℃. In addition, salt affected the formation of bound 3-MCPD. As the amount of salt increased, the amount of bound 3-MCPD also increased significantly. Moreover, it was observed that the amount of oil did not affect the formation of bound 3-MCPD. These results will aid in the reduction of bound 3-MCPD in fried snacks.