• Title/Summary/Keyword: 기기

Search Result 18,163, Processing Time 0.052 seconds

A study on the implementation of Medical Telemetry systems using wireless public data network (무선공중망을 이용한 의료 정보 데이터 원격 모니터링 시스템에 관한 연구)

  • 이택규;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.278-283
    • /
    • 2000
  • As information communication technology developed we could check our blood pressure, pulsation electrocardiogram, SpO2 and blood test easily at home. To check our health at ordinary times is able though interlocking the house medical instrument with the wireless public data network This service will help the inconvenience to visit the hospital everytime and will save the individual's time and cost. In each house an organism data which is detected from the human body will be transmitted to the distance hospital and will be essentially applied through wireless public data network The medical information transmit system is utilized by wireless close range network It would transmit the obtained organism signal wirelessly from the personal device to the main center system in the hospital. Remote telemetry system is embodied by utilizing wireless media access protocol. The protocol is embodied by grafting CSMA/CA(Carrier Sense Multiple Access with Collision Avoidance) protocol falling mode which is standards from IEEE 802.11. Among the house care telemetry system which could measure blood pressure, pulsation, electrocardiogram, SpO2 the study embodies the ECC(electrocardiograph) measure part. It within the ECC function into the movable device and add 900㎒ band wireless public data interface. Then the aged, the patients even anyone in the house could obtain ECG and keep, record the data. It would be essential to control those who had a health-examination heart diseases or more complicated heart diseases and to observe the latent heart disease patient continuously. To embody the medical information transmit system which is based on wireless network. It would transmit the ECG data among the organism signal data which would be utilized by wireless network modem and NCL(Native Control Language) protocol to contact through wireless network Through the SCR(Standard Context Routing) protocol in the network it will be connected to the wired host computer. The computer will check the recorded individual information and the obtained ECC data then send the correspond examination to the movable device. The study suggests the medical transmit system model utilized by the wireless public data network.

  • PDF

A Study on effective directive technique of 3D animation in Virtual Reality -Focus on Interactive short using 3D Animation making of Unreal Engine- (가상현실에서 효과적인 3차원 영상 연출을 위한 연구 -언리얼 엔진의 영상 제작을 이용한 인터렉티브 쇼트 중심으로-)

  • Lee, Jun-soo
    • Cartoon and Animation Studies
    • /
    • s.47
    • /
    • pp.1-29
    • /
    • 2017
  • 360-degree virtual reality has been a technology that has been available for a long time and has been actively promoted worldwide in recent years due to development of devices such as HMD (Head Mounted Display) and development of hardware for controlling and executing images of virtual reality. The production of the 360 degree VR requires a different mode of production than the traditional video production, and the matters to be considered for the user have begun to appear. Since the virtual reality image is aimed at a platform that requires enthusiasm, presence and interaction, it is necessary to have a suitable cinematography. In VR, users can freely enjoy the world created by the director and have the advantage of being able to concentrate on his interests during playing the image. However, the director had to develope and install the device what the observer could concentrate on the narrative progression and images to be delivered. Among the various methods of transmitting images, the director can use the composition of the short. In this paper, we will study how to effectively apply the technique of directing through the composition of this shot to 360 degrees virtual reality. Currently, there are no killer contents that are still dominant in the world, including inside and outside the country. In this situation, the potential of virtual reality is recognized and various images are produced. So the way of production follows the traditional image production method, and the shot composition is the same. However, in the 360 degree virtual reality, the use of the long take or blocking technique of the conventional third person view point is used as the main production configuration, and the limit of the short configuration is felt. In addition, while the viewer can interactively view the 360-degree screen using the HMD tracking, the configuration of the shot and the connection of the shot are absolutely dependent on the director like the existing cinematography. In this study, I tried to study whether the viewer can freely change the cinematography such as the composition of the shot at a user's desired time using the feature of interaction of the VR image. To do this, 3D animation was created using a game tool called Unreal Engine to construct an interactive image. Using visual scripting of Unreal Engine called blueprint, we create a device that distinguishes the true and false condition of a condition with a trigger node, which makes a variety of shorts. Through this, various direction techniques are developed and related research is expected, and it is expected to help the development of 360 degree VR image.

A Study on the Demand for Equipent Development in Nursing (간호기기 개발수요 조사연구)

  • Chang, Soon-Book;Kim, Eui-Sook;Whang, Ae-Ran;Kang, Kyu-Sook;Suh, Mi-Hae
    • The Korean Nurse
    • /
    • v.35 no.2
    • /
    • pp.71-91
    • /
    • 1996
  • The objectives of thes study were to identify the need for equipment development in nursing, and to determine the priorities for that development. The study was descriptive study done between March 2 and May 30, 1995, in which the subjects, including 421 patients, 223 family members, and 198 nurses from neurosurgery, orthopedic, rehabilitation medicine, internal medicine and intensive care units of nine general hospitals in Seoul, completed a questionnarie developed by the research team. The questionnaire consisted of 35 open and closed questions. Data was analyzed using frequencies and percentages. The results ware summarized as follows: 1) The average age of the nurses was 27.9 years, 48% of the patients were between 20 and 40 years of age, and 17% were over 60. The average lingth of experience for the nurse subjects was four years five months with 36.9%. having over five years experience. The most frequent diagnoses of patients were spinal disc(35.9%), internal medicine disease(26.0%), cerebral vascular accident(16.6%) and spinal cord injury(10%) 2) Many of the nurses(96.4%) reported deficiencies with existing equipment and 96.5% of the nurses, but only 79.8% of the patients, nurses' time. Further, 82.3% of the nurses and 75.8% of the patients felt that the development of new equipment would lead to a decrease in the cost of nursing care. 3) Nurses felt that the greatest areas of inconvenience were patient feeding(71.7%), hygiene(71.2%), caring for a patient confined to bed(70.7%), patient clothing(67.2%), mobility transfers(63.5%) and urinary elimination(52.0%). However, patients and family members listed the following as being the most inconvenient: urinary elimination(58.7%), Hygiene(50.5), feeding(48.4%), mobility transfers(47.1%) and bed care(45.2%). 4) Generally the nurses listed more inconveniences and patients and family members listed more demands for the development of equipment. These included utensils with large handles, and regulators for tube feedings; mattresses that provide for automatic position change and massage, which have patient controlled levers and a place for bed pan insertion; automatic lifts or transfer from bed to wheelchair; equipment to facilitate washing and oral hygiene as well as equipment that will allow patients with spinal cord injuries easy access to showers; a bed pan/urinal for women that is comfortable and effective from which urine can be measured and disposed of easily; disposable dressing sets and tracheostomy care sets and a convenient way of measuring changes in wound size; a safe delivery system for oxygen, a variety of mask sizes and better control of humidity, tracheal material than at present, as well as a communication system for patients with tracheostomies; clothing that will allow access to various parts of the body for treament or assessment without patients having to remove all of their clothing; and finally a system that will allow the patient to control lighting, telephones and pagers. Priority areas for equipment development reported by the nurses were, urinary elimination(58. 7%), hygiene(50.5%), feeding(48.4%), mobility transfers(47..1%), bowel elimination(40.8%). Those reported by the patients family members were feeding(71.7%), hygiene(70.0%), bedcare(70.7%), clothing(67.2%), mobility transfers(63.6%), urinary elimination(52.9%) and bowel elimination(50.5%) Altogether, nurses, patients and family members listed the following as priorities; clothing (178), bed care(144), urinary elimination(92), environment(81), hygiene(70). Further, a health professional forum listed urinary elimination, oxygen delivery, medication delivery, mobility transfers, bed care and hygiene in that order as priority areas. From this study it can be concluded that the first need is to develop equipment that will address the problems of urinary elimination. To do (l)This nurses who are interested in equipment development should organize an equipment development team to provide a forum for discussion and production of equipment for nursing.

  • PDF

The Effect of addition of CuO to Fe2O3/ZrO2 Oxygen Carrier for Hydrogen Production by Chemical Looping (매체 순환식 수소제조공정에 적합한 Fe2O3/ZrO2 산소전달입자에 구리 산화물 첨가가 미치는 영향에 관한 연구)

  • Lee, Jun Kyu;Kim, Cho Gyun;Bae, Ki Kwang;Park, Chu Sik;Kang, Kyoung Soo;Jeong, Seong Uk;Kim, Young Ho;Joo, Jong Hoon;Cho, Won Chul
    • Korean Chemical Engineering Research
    • /
    • v.54 no.3
    • /
    • pp.394-403
    • /
    • 2016
  • $H_2$ production by chemical looping is an efficient method to convert hydrocarbon fuel into hydrogen with the simultaneous capture of concentrated $CO_2$. This process involves the use of an iron based oxygen carrier that transfers pure oxygen from oxidizing gases to fuels by alternating reduction and oxidation (redox) reactions. The enhanced reactivities of copper oxide doped iron-based oxygen carrier were reported, however, the fundamental understandings on the interaction between $Fe_2O_3$ and CuO are still lacking. In this study, we studied the effect of dopant of CuO to $Fe_2O_3/ZrO_2$ particle on the morphological changes and the associated reactivity using various methods such as SEM/EDX, XRD, BET, TPR, XPS, and TGA. It was found that copper oxide acted as a chemical promoter that change chemical environment in the iron based oxygen carrier as well as a structural promoter which inhibit the agglomeration. The enhanced reduction reactivity was mainly ascribed to the increase in concentration of $Fe^{2+}$ on the surface, resulting in formation of charge imbalance and oxygen vacancies. The CuO doped $Fe_2O_3/ZrO_2$ particle also showed the improved reactivity in the steam oxidation compared to $Fe_2O_3/ZrO_2$ particle probably due to acting as a structural promoter inhibiting the agglomeration of iron species.

Analysis of $^1H$ MR Spectroscopy of parietal white matter material Phantom (두정부 백질 물질을 이용한 수소 자기 공명 분광 분석)

  • Lee, Jae-Yeong;Lim, Cheong-Hwan;Kim, Myeong-Soo
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.57-61
    • /
    • 2003
  • The purpose of this study is to compare both 1.5T and 4.7T in Praietal White matter material Phantom using the same methodology at both field strengths. Data at both field strengths are compared in terms of $T_2$ relaxation times, line widths and SNRs MR imaging and $^1H$ MR spectroscopy were performed on GE 1.5T SIGNA system and Broker Biospec 4.7T/30 MRI/MRS system. After phantom axial scan $^1H$ MRS was obtained from T2 weighted image by 3-dimensional localization technique(PRESS : Point RE solved spectroscopy Sequence) this phantom is composed of an aqueous solution 36.7 mmol/L of NAA, 25.0 mmol/L of Cr, 6.3 mmol/L of choline chloride, 30.0 mmol/L or Glu, and 22.5 mmol/L of MI(adjusted to a pH of 7,15 in a phosphate buffet). Data processed using software developed inhouse. At 1.5T, T2 relaxation times for Cho, Cr, and NAA were $0.41{\pm}0.07,\;0.26{\pm}0.04,\;0.46{\pm}0.07$ while at 4.7T they were $0.17{\pm}0.03,\;0.14{\pm}0.05,\;0.20{\pm}0.03$ respectively. At 1.5T, line widths for water, Cho, Cr and NAA were $2.9{\pm}0.7,\;1.6{\pm}0.7,\;1.7{\pm}0.8,\;2.2{\pm}0.02Hz$ while at 4.7T they were $5.2{\pm}1.1,\;4.6{\pm}1.9,\;4.01{\pm}1.8,\;4.8{\pm}1.9Hz$ respectively. It can be seen that $T_2$ relaxation times were significantly shorter at 4.7 compared to 1.5T and that the line widths were also broader. The average SNRs for NAA for subjects at short and long TEs were $23.5{\pm}11.3$ at TE=20 msec ; $15.4{\pm}7.7$ at TE=272 msec at 1.5T and $40{\pm}8.3$ and $17{\pm}3.5$ respectively at 4.7T higher field strength is superior because of improved sensitivity and chemical shift dispersion. However these improvements are partially offset by increased line widths and decrease $T_2$ relaxation times, which act to reduce both sensitivity and resolution. In our experiments with the equipment available to us, 4.7T proton spectra at short TEs exhibit moderately improved sensitivity compared to 1.5T.

  • PDF

Clinical Usefulness of Chest Wall Ultrasonography for Detecting Fractures of Costal Cartilage due to Minor Blunt Chest Trauma (경미한 둔상에 의하여 야기되는 늑연골 골절 진단에 있어서 흉벽 초음파 검사의 임상적 유용성)

  • Lee, Woo-Surng;Kim, Yo-Han;Chee, Hyun-Keun;Hwang, Jae-Joon;Lee, Song-Am;Jung, Ho-Sung;Shin, Hyun-Joon;Choi, Young-Chill
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.502-508
    • /
    • 2009
  • Background: Rib fractures are the most common injuries that are caused by blunt chest trauma. However, fractures of the costal cartilage generally go unnoticed on chest X-rays unless they involve a calcified cartilage. For this reason, the sensitivity of conventional radiography for detecting rib fractures is low, and especially those involving the cartilaginous part of the rib. Thus, we have evaluated the usefulness of ultrasonography for detecting fractures of the costal cartilage that were overlooked on the conventional radiographs of patients who suffered minor blunt chest traumas. Material and Method: A total of 45 patients who suffered minor blunt chest trauma and who had no evidence of rib fractures or other major fractures on conventional radiographs were admitted for ultrasonography between April 2008 and March 2009. There were 24 women and 21 men, and the mean age of the patients was 50.4$\pm$15.91 years (range: 17$\sim$76 years). They were examined for the detection of fractures of the costal cartilage by performing ultrasonography with a 7.5-MHz linear transducer. Result: A total of 30 patients (67%) had fractures of the costal cartilage, whereas 15 patients (33%) had no evidence of chondral rib fractures. The mean number of fracture sites of the fractured costal cartilage was 1.6$\pm$0.81 (range: 1$\sim$4 sites) in 30 patients. Periosteal hematoma was the most common finding associated with fractures of the costal cartilage (n=7, 17%), followed by sternum fracture (n=5, 12%). However, periosteal hematoma was noticed in 1 patient (2%) who was without fracture of the costal cartilage, and sternum fracture was noticed in 1 patient (2%) who was without fractures of the costal cartilage. Conclusion: The results of this study suggest that ultrasonography may be a useful imaging modality for detecting fractures of the costal cartilage that are overlooked on the conventional radiographs of patients who suffer minor blunt chest trauma.

Development of High-performance Microwave Water Surface Current Meter for General Use to Extend the Applicable Velocity Range of Microwave Water Surface Current Meter on River Discharge Measurements (전자파표면유속계를 이용한 하천유량측정의 적용범위 확장을 위한 고성능 범용 전자파표면유속계의 개발)

  • Kim, Youngsung;Won, Nam-Il;Noh, Joonwoo;Park, Won-Cheol
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.8
    • /
    • pp.613-623
    • /
    • 2015
  • To overcome the difficulties of discharge measurements during flood season, MWSCM(micowave water surface current meter) which measures river surface velocities without contacting water has been applied in field work since its development. The existing version of MWSCM is for floods so that its applicability is low due to the short periods of floods. Therefore the renovative redesign of MWSCM to increase the applicability was conducted so that it can be applied to the discharge measurements during normal flows as well as flood ones by extending the measurable range of velocity. A newly developed high-performance MWSCM for general use can measure the velocity range of 0.03-20.0 m/s from flood flows to normal flows, whereas MWSCM for floods can measure the velocity range of 0.5-10.0 m/s. The improvement of antenna isolation between transmitter and receiver to block the inflow of transmitted singals to receiver and the improvement of phase noise of oscillator are necessary for detecting low velocity with MWSCM technology. Separate type antenna of transmitting and receiving signals is developed for isolation enhancement and phase locked loop synthesizer as an oscillator is applied to high-performance MWSCM for general use. Microwave frequency of 24 GHz is applied to the new MWSCM rather than 10 GHz to make the new MWSCM small and light for convenient use of it at fields. Improvement requests on MWSCM for floods-stable velocity measurement, self test, low power consumtion, and waterproof and dampproof-from the users of it has been reflected on the development of the new version of MWSCM.

Genesis and Characteristics of the Soil Clay Minerals Derived from Major Parent Rocks in Korea -I. Rock-forming Minerals and Mineralogical Characteristics of the Parent Rocks (한국(韓國)의 주요(主要) 모암(母岩)에서 발달(發達)된 토양점토(土壤粘土) 광물(鑛物)의 특성(特性)과 생성학적(生成學的) -I. 조암광물(造岩鑛物)과 광물학적(鑛物學的) 특성(特性))

  • Um, Myung-Ho;Lim, Hyung-Sik;Kim, Young-Ho;Um, Ki-Tae
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.24 no.1
    • /
    • pp.1-9
    • /
    • 1991
  • A study was carried out to investigate the composition of rock-forming minerals and mineralogical characteristics of the five major parent rocks in Korea. The identification was done through the analyses of chemical. X-ray diffraction, thermal(DTA, TG), infrared spectroscopic, and microscopic methods. Among these methods, X-ray diffraction was considered to be the most rapid and effective way to identify minerals in the parent rocks. The main rock-forming minerals of the parent rocks were feldspars, quartz, and micas in granite and granite-gneiss, calcite and dolomite in limestone, quartz and calcite in shale, plagioclase and augite in basalt. A small amount of sesquioxides was identified as a accessory mineral by means of DTA from the parent rocks of Weoljeong series(granite) and Cheongsan series(granite-gneiss). The abrasion pH affecting the soil formation ranged from 7.5 to 8.4 in the parent rocks containing ferromagnesian minerals and carbonates. In the granite and granite-gneiss of which the main rock-forming minerals were feldspars and quartz with low content of biotite, the abrasion pH ranged from 6.2 to 6.4. In chemical composition of the parent rocks, Si, AI, and K oxides tented to increase with higher contents of quartz, feldspars, and muscovite, while Fe and Mg oxides with higher content of biotite, chlorite, amphiboles, and augite. Higher ignition loss in limestone and shale resulted in the release of $CO_2$ from calcite and/or dolomite.

  • PDF

Analysis and Improvement Measures on the Status of the Installation and Operation of Facilities for Recycling Food Waste into Compost (음식물쓰레기 퇴비화시설의 설치 및 운영 현황분석 및 개선방안)

  • Ryu, Ji-Young;Kong, Kyu-Sik;Shin, Dae-Yewn;Phae, Chae-Gun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.3
    • /
    • pp.95-111
    • /
    • 2004
  • This research sought to determine the status of the installation and operation of composting facilities of domestic public resource-making facilities and come up with corresponding improvement measures. The composting facilities were the most extensively installed of related facilities with over a 0.5 ton treated volume per day. The monthly and yearly carry-in volume of food waste were found to stand at 1,101.7 tons per day and 930.9 tons per day, thus falling short of the average planned volume of 1,270.9 tons. Many composting facilities, which were installed in areas for which factory registration were not approved, did not get approvals. Composting facilities underwent operation stoppage mainly due to faulty fermentation and crushing equipment. Mainly metals contained in food waste caused faults to the crushing equipment, thus requiring a facility designing against faults and corrosion. The initial water content was found to stand at 50-60%, thus complying with the requirement. However, since the composting food waste had an appropriate mixture of sawdust, food waste, and returned compost, it should meet the initial conditions. For fermentation facilities, the duration time for fermentation was 15 days, and post-fermentation tanks required 21 days of duration time, thus establishing the minimum criteria. However, some facilities did not meet the requirements, taking more time in decomposition, thus suggesting a need to determine the duration time according to facilities. In composting food waste, microorganism-based thermal oxidizer-operated fermentation tanks should be used to ensure an economic operation. On the contrary, 14 out of 25 survey targets heated fermentation tanks in any form. These thermal facilities contain the growth of bacteria, lowering chemical reaction in composting; thus composting facilities should be basically designed to use microorganism-based thermal oxidizers in drying water. An average daily volume of food waste and supplementary materials that was injected in producing compost was 22.8 tons. This volume produced 7.3 tons of compost per day, decreasing 68%. Properties of produced compost were analyzed by its color, absence or presence of remaining decomposition heat, and smell, to assess the quality. As a result, the composting process was not properly installed nor operated in about 50% of composting facilities. Compost should be produced to be soil-friendly.

  • PDF

A Study on Driving Safety Evaluation Criteria of Personal Mobility (퍼스널 모빌리티(Personal Mobility)의 주행안전성 평가지표 연구)

  • Park, Bumjin;Roh, Chang-gyun;Kim, Jisoo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.17 no.5
    • /
    • pp.1-13
    • /
    • 2018
  • Divers types of Personal Mobility(PM) are appeared on the market after the Segway is introduced. PMs have propagated very rapidly with their ease of use, and accidents related with PM show a sudden increase. Many studies on the PM are performed as its trend, but dring safety of passengers are excluded. In this study, criteria which can be adopted for PM's driving safety evaluation are reviewed. Also result of driving safety evaluation on 3 types of PM(wheel chair, kickboard, scooter(seating/standing) and walking using deducted criteria is given. COG(Center of the gravity) and SM(Stability Metric) are finally selected two criteria among many of them used in other fields. COG indicates how the center of mass deviates from the direction of the gravity. SM is a normalized value of generated force when PM moves as internal force, angular momentum, and ground reaction force. 0 means stop, and negative value means rollover, so it can be used for safety evaluation of PM. Average and standard deviation of measurement are standard of safety on the COG analysis. Wheel chair is the most safe and kickboard is the most unstable on the COG analysis. Wheel chair is also ranked as top safe on the SM analysis. Among two riding types(seating and standing) on the scooter, seating type is evaluated more safer than standing type. It is proposed that more various type of PMs are need to get safety evaluation for drivers and devices themselves together.