• Title/Summary/Keyword: 기공식

Search Result 250, Processing Time 0.026 seconds

A Study on the Relationship between Dental Technician's Working Environment and Job Stress (치과기공사의 작업환경과 직무스트레스 관련 연구)

  • Kwon, Eun-Ja;Lee, Gyu-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2471-2477
    • /
    • 2009
  • The purpose of this study was to analyze dental technician's job environment and job stress level and to examine its correlation. 180 dental technicians in Seoul, Incheon, and Chungnam area were selected. Survey was carried out from April 6, 2009 to May 20, 2009 by using self-administered questionnaire. The following are the analytical results in the collected data. 1. As a result of analyzing the research subjects' working environment level, there was significant difference in the item of health(P<0.05). The average in the working environment was indicated to be high with 1.53. 2. As a result of analyzing the research subjects' job-stress causing level, there was no significant item in all the variables. The average of job stress was indicated to be high with 3.44. 3. As for correlation between working environment and job stress, most of variables were indicated to have reverse correlation, thereby having been shown that the worse working environment leads to the more job stress.

A Study on the Evaluation Method of Lap Shear Strength for Induction Welding of Thermoplastic Composites using Tensile Test (인장 시험을 이용한 열가소성 복합재료 유도용접 전단강도 평가방법에 대한 고찰)

  • Baek, Inseok;Lee, Seoksoon
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.1
    • /
    • pp.12-16
    • /
    • 2022
  • Currently, Induction welding is attracting attention as a non-contact, clean and fast welding process. However, since thermoplastic resins are not affected by electromagnetic fields, induction welding requires a heating element called a susceptor. Researches are being conducted with the aim of achieving high-quality bonding, however, the factor of a heating element is an issue, hence the need to set a standard. Specimen fabrication and testing are conducted according to ASTM D5868. In this study, we propose that the evaluation criteria be judged on the basis of three factors; the condition of the welded joint surface, void content, and lap shear strength. Since the adhesive surface to be welded melts and solidifies as it cools, rapid temperature changes can generate pores. In addition, if the heating is not uniform, it is difficult to expect the desire performance. Using PA6 (CF 30%) thermoplastic, susceptor fabrication, induction welding and performance verification were conducted.

An Experimental Study on the Hydration and Mechanical Properties of High Strength Concrete with High Calcium Sulfate Cement (고황산염시멘트를 이용한 고강도콘크리트의 수화 및 역학적 특성에 관한 실험적 연구)

  • 박승범;임창덕
    • Magazine of the Korea Concrete Institute
    • /
    • v.5 no.1
    • /
    • pp.129-138
    • /
    • 1993
  • 프리텐션 방식 원심력 고강도 콘크리트 말뚝[KS F 4306]제조에 관한 실험적 연구로써 고황산염시멘트를 이용한 800kg/$ extrm{cm}^2$이상의 고강도콘크리트 제조시 수화 특성검토와 콘크르트 조직내의 기공율과 압축강도간의 상관식을 도출하여 고강도 발현기구를 규명하였으며 콘크리트 압축 및 휨강도간의 상관식 유도와 내구성 측면에서의 내동해성, 건조수축, 화학저항성등을 보통 포틀랜드 시멘트와 비교 고찰한 결과, 고황상염시멘트의 내구성이 우수함을 확인하였다.

NUMERICAL ANALYSIS OF ERGUN'S EQUATION FOR INTERIOR BALLISTIC ANALYSIS (강내탄도 해석에 사용되는 Ergun식에 관한 수치적 연구)

  • Bae, S.W.;Sung, H.G.;Roh, T.S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.473-478
    • /
    • 2010
  • In this study, the Ergun's equation has been verified in order to calculate pressure drop of the two phase flow. The equation had been used in the high Reynolds number region for interior ballistic analysis in spite of being verified in the low Reynolds number region. Therefore additional verification seems to be inevitable. Thus, the validity of the equation has been verified using CFD in the high Reynolds number cases of the diameter-particle ratio 10, 13 and 16.

  • PDF

금속-유기 구조체 기반 비효소식 글루코오스 센서

  • Kim, Gi-Jun;Bae, Yun-Sang;Kim, Hyeon-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.92.2-92.2
    • /
    • 2018
  • 빠르고 정확한 글루코오스 농도 측정은 의료, 식품, 환경 등 다양한 산업에서 매우 중요하다. 글루코오스 산화효소를 기반으로 하는 현재 글루코오스 센서는 높은 감도와 선택성을 갖지만 온도변화나 다른 화학물 등 환경에 취약하다는 단점이 있다. 따라서 최근 비효소식 글루코오스 센서에 대한 연구가 활발히 진행되고 있다. 금속-유기 구조체(MOFs)는 금속이온과 유기물 리간드로 구성된 결정성 다공체로, 큰 기공 크기와 비표면적, 안정성 등을 특징으로 갖는다. 대부분의 MOFs는 전기전도도가 낮지만 금속이온의 산화/환원, 리간드의 화학적 개질을 통해 전기화학분야에서도 다양하게 연구되고 있다. 본 연구에서는 글루코오스 농도 측정을 위한 전극촉매로 다양한 금속이온과 리간드로 이루어진 MOFs를 합성했다. 표면분석을 통해 MOFs의 전기화학적 처리 전후의 구조와 성질 변화를 관찰했고 전기화학적 분석을 통해 금속이온과 리간드의 종류가 감도, 선택성 등 글루코오스 검지 성능에 주는 영향을 분석했다. 그 결과 Ni, Co 기반의 MOFs가 글루코오스에 대해 높은 감도를 보였으며 이를 통해 MOFs의 글루코오스 센서로의 응용 가능성을 확인했다.

  • PDF

Effect of Temperature on the Growth of Korean Valerian (Valeriana fauriei var. dasycarpa HARA) (온도가 한국산 쥐오줌풀의 생육에 미치는 영향)

  • Lee, Jong-Chul
    • Korean Journal of Medicinal Crop Science
    • /
    • v.3 no.2
    • /
    • pp.77-80
    • /
    • 1995
  • This study was carried out to know the effect of air temperature on photosynthesis and growth of Korean Valerian (valeriana fauriei var. dasycarpa HARA). The results are as follows; 1. Photosynthesis of V fauriei had highly significant relation to temperature in a quadratic regression mo­del, from which the optimum temperature for the plant growth were estimated to be $17.7^{\circ}C$. During the day­time in the field condition, the photosynthesis rate was highest at 9 a.m, then reduced to minimum at 2 p.m., and increased again thereafter. 2. Number of stomata was about $25/mm^2$ on the upper side and $85/mm^2$ on the lower side of the leaf, and the size was $21{\sim}30/{\mu}m$ in diameter. 3. A highly significant quadratic regression was noted between temperature and leaf width or root weight of V. fauriei. It was estimated from the regression equation that the optimum temperature for root growth was $20.3^{\circ}C$.

  • PDF

Study on Curriculum of Denture clinician (의치사의 교육과정에 관한 연구)

  • Park, Myung-Ho;Bae, Bong-Jin;Lee, Hwa-Sik;Lee, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.32 no.1
    • /
    • pp.47-56
    • /
    • 2010
  • As Korea is entering an aging society, the number of elderly people who need new denture or who have problems with their existing denture or adjacent tissue is increasing and it will double in 2018. Therefore, denture clinician system will lessen patients financial burden and introduce market economy to the dental prosthesis field. Therefore, Korea needs to adopt denture clinician system as soon as possible as USA or Canada to increase people s accessibility in quality and quantity. Denture clinician will determine the size and shape of denture after performing oral examination, make impression using various materials, fabricate denture, deliver and adjust completed denture to the patient, repair denture, and carry out financial management in the denture fabricating company or manage human resources. Considering denture clinicians services, American and European education system seems to be close to our system. Therefore, in this study, basic curriculums of several countries in Europe and America were reviewed and curriculum that meets Korean situation was suggested.

Heat Transfer and Flow Characteristics in an Annulus Filled with Aluminum Foam (발포 알루미늄이 삽입된 환형관에서의 열전달 및 유동특성)

  • Noh Joo-Suk;Han Young-Hee;Lee Kye-Bock;Lee Chung-Gu
    • Journal of Energy Engineering
    • /
    • v.15 no.1 s.45
    • /
    • pp.60-66
    • /
    • 2006
  • An experimental investigation on the flow and convective heat transfer characteristics has been carried out far aluminum foam heat sink inserted into the annulus to examine the feasibility as a heat sink. Two aluminum foams or different permeability were selected to provide the friction factor and heat transfer correlations as function of Darcy, Reynolds and Prandtl number. Experimental results show that the friction factor is higher than clear annulus without aluminum foam, while $6\sim10$ times augmentation in Nusselt number is obtained. This technique can be used for the compactness of the heat exchanger.

A study of introduction for using Laser in dental prosthesis (치과보철영역에 레이저 이용을 위한 이론적 고찰)

  • Park, Myoung-Ho;Bae, Bong-Jin;Lee, Hwa-Sik
    • Journal of Technologic Dentistry
    • /
    • v.30 no.1
    • /
    • pp.131-139
    • /
    • 2008
  • It's very important to find the most appropriate adhesion technique available, taking into consideration factors such as biocompatibility, non-corrosiveness, mechanical stability, etc. Laser welding is the best choice you can make because from a mechanical viewpoint, a laser welded surface has better particle structure than does a casted particle structure. Furthermore, it requires no additional material and the same metal alloy which is used when casting can be used. Therefore, the resulting mixture will consist of a single alloy, instead of utilizing different alloy combinations. Another benefit is the low economic cost. The most beneficial aspects of laser welding is that it is biologicallly friendlly, doesn't require soldering, can fuse different metal alloys together, and can weld on heat-sensitive spots(E.g. around resin or ceramic). A consistent strong pulse is possible. This technique is capable of welding on master models and creates accurate welds. It is capable of due to its stronger, non-corrosive microscope, which allows 25times magnification during the soldering process. This is possible because of its high stability from the tiny particle structure.

  • PDF

An Experiment on How the Length and the Diameter of the sprue Effects the Size of the porosity, that is Created During the Moduling Process (주조 시 발생되는 porosity가 sprue의 길이와 굵기에 따라 주조체에 미치는 영향에 관한 실험적 연구)

  • Hwang, Seung-Sig
    • Journal of Technologic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.13-20
    • /
    • 2000
  • This experiment was done to find out how the length and the diameter of the sprue effects the porosity created during the moduling process, which is caused by the metal's shrinking and stretching action. the experiment was done in two groups(A and B), using experimental gold, and made 10 copings for both groups. 1. In group A, The length of the sprues were given the same, but the diameter of the sprue were 6, 8, 10, 12, 18 gauge. As a result, the porosity came out big with 12 and 18 gauge and for 10, 8, 6 gauge, the porosity was hardly seen or none was noticeable. 2. In group B, the diameter was given the sam for the sprues, but the length of the sprues were 5, 10, 15, 20, 25mm. As a result, the porosity came out big with 25, 20, 15mm the porosity was hardly seen or none was noticeable. 3. The diameter needs to be big and the length, short. 4. The appropriate sized sprue must be chosen for each individual tooth, according to it's shape and size.

  • PDF