• Title/Summary/Keyword: 기계적이음

Search Result 9,625, Processing Time 0.039 seconds

Design and fabrication of Smart Skin Antenna for Phased Array Applications (위상배열 응용을 위한 스마트 스킨 안테나 설계 및 제작)

  • Son, Seong-Ho;Hwang, Woon-Bong
    • Composites Research
    • /
    • v.20 no.3
    • /
    • pp.25-30
    • /
    • 2007
  • This paper describes the basic design and fabrication of smart skin antenna for phased array applications. The smart skin phased array antenna, of which radiation pattern can be electrically steerable without mechanical rotation, has to meet the both mechanical and electrical performance. The smart skin antenna is a honeycomb sandwich structure to enhance the mechanical performance such as strength, weight and so on. The example of smart skin antenna integrated with radome is designed with the resonant frequency of 5 GHz, circular polarization, 2 by 2 subarray, and a coaxial probe-fed excitation. In addition, the performance of raw microstrip patch antenna uncovered radome is investigate. The fabricated smart skin antenna shows a reasonable performance with gain of 12.2 dBi and frequency bandwidth of 6.4 %.

Surface and Chemical Properties of Surface-modified UHMWPE Powder and Mechanical Properties of Self Curing PMMA Bone Cement Containing UHMWPE Powder I. Effect of MMA/Xylene Contents on Surface Modification of UHMWPE (표면개질된 초고분자량 폴리에틸렌 분말의 표면과 화학적 특성 및 이를 함유하는 상온 경화용 폴리(메틸 메타크릴레이트) 뼈 시멘트의 기계적 특성 I. 메틸 메타크릴레이트/자일렌 함량에 따른 초고분자량 폴리에틸렌의 표면 개질 효과)

  • 양대혁;윤관희;김순희;이종문;강길선
    • Polymer(Korea)
    • /
    • v.28 no.1
    • /
    • pp.77-85
    • /
    • 2004
  • It has been widely used ultra high molecular weight polyethylene (UHMWPE) for the biomaterials due to its excellent mechanical properties and biocompatibility. In the case of blend of UHMPE with another polymeric biomaterials, however, UHMWPE might have low blend compatibility due to surface inertness. In this study, in order to improve the mechanical properties of poly(methyl methacrylate) (PMMA) bone cement by means of the impregnation of UHMWPE powder, we developed the novel surface modification method by the mixture of methyl methacrylate (MMA) and xylene. We investigated the variation of composition of MMA/xylene. It was confirmed by the analysis of Fourier transform infrared-attenuated total reflectance, scanning electron microscope, universal transverse mercator, and digital thermometer. The maximum mechanical strength of surface modified UHMWPE powder impregnated PMMA bone cement compound was observed the ratio of 1 : 1 (v/v%) MMA/xylene. Also its curing temperature decreased from 103 $^{\circ}C$ to 58 ∼ 73 $^{\circ}C$ The mechanism of surface modification of UHMWPE powder by the mixture of MMA/xylene has been proposed.

Enhancement of Au·Ag Leaching by Mechanochemical Activation and Thiourea-Thiocyanate Mixing Solution (기계적-화학적 활성화와 티오요소-티오시안산염 혼합용액에 의한 Au·Ag 용출 향상)

  • You, Don-Sang;Park, Cheon-Young
    • Journal of the Korean earth science society
    • /
    • v.35 no.6
    • /
    • pp.401-411
    • /
    • 2014
  • In order to enhance the Au Ag leach rate, a mechanochemical activation process and a mixed thiourea-thiocyanate solution has been applied to Au concentrate. To achieve mechanochemical activation, the Au concentrate was mechanically ground using a dry and a wet process. The results of a particle size distribution analysis and an XRD analysis, average particle size and crystallite size were much smaller in the dry-sample than in the concentrate sample. As well the size was smaller in the wet-sample than in the dry-sample. In SEM and XRD analysis, the amorphization effect was observed in the wet-sample due to mechanochemical activation. Au Ag leaching experiments were carried out with a thiourea solution, a thiocyanate solution and a mixed thiourea-thiocyanate solution. The Au Ag leach rate was much greater in the dry-ground-sample than in the concentrate sample, and the leach rate was greater in the wet-ground-sample than in the dry-sample. The Au Ag leach rate was much greater in the thiocyanate solution than in the thiourea solution, and the leaching rate was much greater in the mixed thiourea-thiocyanate solution than in the thiocyanate solution. Up to a 99% leach rate for Au Ag were only achieved in the wet-sample using the mixed thiourea-thiocyanate leaching solution.

Machining Tolerance of Various Implant Systems and their Components (치과용 임플란트 시스템의 기계적 가공오차에 관한 연구)

  • Kim, Hyeong-Seob;Kwon, Kung-Rock;Han, Jung-Suk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.1
    • /
    • pp.57-65
    • /
    • 2008
  • Purpose: Misfit of implant components was very important in terms of prosthodontics. they has been linked to prosthetic complications such as screw loosening and fracture. Although there are many results about rotational freedom or machining tolerance between fixture and abutments, the data about domestic implant systems are lacking. The aim of this in vitro study was to evaluate the rotational freedom of domestic external and internal connection implant systems between their fixtures/anlaogs and abutments comparing imported systems. Materials and Methods: Rotational freedom between abutments and fixtures/analogs was investigated by using digitalized rotational angle measuring device. (1) 1 domestic external connection system(Neobiotec) and 2 imported external connection systems(Nobel Biocare, Anthorgyr), (2) 1 domestic internal connection system(Dentium) and 4 imported external connection systems(Nobel Biocare, Anthorgyr, Straumann, Frident Dentsply), and (3) 1 domestic zirconia external connection abutment(ZirAce) were evaluated. Each group has 3 samples. Mean values for each group were analyzed. Results: The differences relative to rotational freedom between domestic and imported implant systems were observed but domestic external connection implant system showed about 2.67 degrees(in case of fixture) and internal connection system showed about 4.3 degrees(in case of fixture). Domestic zirconia abutment showed less than 3 degrees of rotational freedom in a situation where the abutment was connected to an implant fixture egardless of domestic or imported systems. Conclusion: Newly developed digitalized rotational angle measuring device has high measuring resolution. The rotational freedom of domestic implant systems were similar to imported implant systems.

Short-term Mechanical Circulatory Support with Centrifugal Pump in Cardiac Arrest or Cardiogenic Shock - Report of 5 cases- (심정지 혹은 심인성 쇼크에서 원심성 펌프를 이용한 단기목표의 기계적 순환 보조)

  • 양희철;성기익;뱍계현;전태국;박표원;양지혁;이영탁
    • Journal of Chest Surgery
    • /
    • v.37 no.12
    • /
    • pp.1003-1009
    • /
    • 2004
  • Mechanical circulatory support (MCS) has been used for myocardium failure, but moreover, it may be essential for the life support in cardiac arrest or cardiogenic shock. Many commercial devices can be used effectively for the long-term support. However, there are some limitations in the aspects of the cost and technical support by production company. Short-term support with centrifugal type has been reported numerously with the purpose of bridging to heart transplantation or recovery. We successfully treated 5 patitents who were in the status of cardiogenic shock (n=3) or arrest (n=2) with the technique of extracorporeal life support system (ECLS) or left ventricular assist device (LVAD) using the centrifugal type pump. The MCS were performed emergently (n=2) under cardiac arrest caused by ischemic heart disease, and urgently (n=3) under cardiogenic shock with ischemic heart disease (n=1) or acute fulminant viral myocarditis (n=2). All patients were weaned from MCS. Complications related to the use of MCS were bleeding and acute renal failure, but there were no major complications related to femoral cannulations. Mechanical circulatory support may be essential for the life support and rescue in cardiac arrest or cardiogenic shock.

Effects of Mechanical Horseback Riding Training on Trunk Control and Balance function in Stroke patients (뇌졸중 환자의 체간조절, 균형능력에 기계적 승마치료가 미치는 영향)

  • Song, Myung-Soo;Kang, Tae-Woo;Kim, Su-Mi;Noh, Hyeon-Jeong
    • Journal of Digital Convergence
    • /
    • v.11 no.12
    • /
    • pp.487-494
    • /
    • 2013
  • The purpose of this study was to determine the effect of mechanical horseback riding training on trunk control, balance function in stroke patients. 15 stroke patients were recruited for this study. The subjects were randomly assigned to two groups: experimental(n=7) and control(n=8). All subjects received a routine physical therapy. The mechanical horseback riding training was for 30 min in the case of the EG subjects. This study was carried out approximately 8 weeks from March 4 to May 3. The assessment tools of this study involved the trunk control test, postural assessment scale for stroke, Berg balance scale and timed up and go test. The measurements were recorded before the intervention and after the intervention. In the cases of the EG subjects and CG subjects, the variables measured after the intervention significantly differed from trunk control test, postural assessment scale for stroke, Berg balance scale and timed up and go test before the intervention (p<.05). Also, there were significant differences in trunk control test, postural assessment scale for stroke, Berg balance scale and timed up and go test at post test between the 2 groups (p<.05). The findings indicate that mechanical horseback riding training exerts a positive effect on trunk control, balance function in stroke patients. Further studies are required to generalize the result of this study.

Connection Resistance of Mechanical Joint using Connection plate for Improvement of Connectivity between PHC piles (PHC파일간 연결 시공성 개선 이음판형 기계적 연결부의 연결저항)

  • Ahn, Jin-Hee;Moon, Hong-duk;Ha, Min-Gyun;Cho, Kwang-Il
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.25-32
    • /
    • 2019
  • Welded joints and mechanical joints using bolt connection have been used as a pile-to-pile connecting method for PHC piles. These PHC pile joint methods may have difficulty in securing connecting quality and connecting performance in PHC pile joining process. Therefore, this study proposes a non-welded connection plate type mechanical PHC pile joint to improve the disadvantages of existing PHC pile connection methods and to secure the connection performance of PHC pile joint. Its connection performance was evaluated from nonlinear FE analysis and loading tests for actual PHC piles with suggested pile joints. From nonlinear FE analysis for the proposed PHC pile joint, it was evaluated to have sufficient connection performance under flexural, compressive, tensile, shear, and eccentric compressive load condition. PHC piles connected by the suggested connection plate type mechanical PHC pile joint show that they show stable linear behaviors for the crack moment and the flexural moment level of the PHC pile. Therefore, the proposed a non-welded connection plate type mechanical PHC pile joint can secure sufficient connection performance in PHC pile.

Cure Kinetics and Mechanical Interfacial Characteristics of Zeolite/DGEBA Composites (제올라이트/DGEBA 복합재료의 경화 동력학과 기계적 계면특성)

  • Soo-Jin Park;Young-Mi Kim;Jae-Sup Shin
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.5
    • /
    • pp.472-478
    • /
    • 2003
  • In this work, the zeolite/diglycidylether of bisphenol A(DGEBA) systems were investigated in terms of the cure kinetics and mechanical interfacial properties of the composites. The 4, 4-diamino diphenyl methane(DDM) was used as a curing agent for epoxy. Two types of zeolite(PZ) were prepared with 15 and 35 wt% KOH treatments(15-BZ and 35-BZ, respectively) for 24 h, and their surface characteristics were studied by X-ray photoelectron spectroscopy (XPS) and X-ray diffraction(XRD). Cure kinetics of the composites were examined in the context of differential scanning calorimetry(DSC), and mechanical interfacial properties were investigated in critical stress intensity factor($K_{IC}$) and critical strain energy release rate($G_{IC}$). In the results of XPS and XRD, sodium ion(Na) of zeolite was exchanged for potassium ion(K), resulting from the treatment of KOH. Also, $Si_{2p}/Al{2p}$ composition ratios of the treated zeolite were increased, which could be attributed to the weakening of Al-O bond in framework. Cure activation energy($E_a$) of 15-BZ composites was decreased, whereas KIC and $G_{IC}$ were increased, compared with those of the pure zeolite/DGEBA composites. It was probably accounted that the acidity of zeolite was increased by surface treatments and the cure reaction between zeolite and epoxy was influenced on the increased acidity of zeolite.

ASSESSMENT OF THE CHEMOMECHANICAL CARIES REMOVING EFFICACY - MICROTOMOGRAPHIC STUDY - (화학.기계적 우식제거 효능의 평가에 대한 미세전산화 단층 촬영을 이용한 연구)

  • Hahn, Soo-Kyoung;Kim, Jung-Wook;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.406-414
    • /
    • 2003
  • Chemomechanical approach to caries removal was introduced in order to preserve the maximum amount of sound tooth structure. The efficacy of chemomechanical caries removal was assessed using microcomputed tomography which offers 3 dimensional data without destroying the tooth, and the V works program. In group 1, the density values of the sound dentin, carious dentin, and remaining dentin after chemomechanical treatment were analyzed. In group 2, the density values of the sound dentin, cavity wall prepared using high speed bur, and the remaining dentin after additional $Carisolv^{TM}$ gel application on the same cavity were analyzed. The results were as follows; 1. The density value of the remaining dentin after the $Carisolv^{TM}$ treatment was 81.8% of the sound dentin(p < 0.001). 2. The density value of the remaining dentin after the conventional rotary instrument showed no statistically significant difference from that of the sound dentin(p = 0.234).

  • PDF

A Comparative Study on Assessment of Speed Enforcement by Unmanned Camera and Policeman (기계적 단속 및 인력단속에 의한 과속단속 효과 분석)

  • Gang, Su-Cheol;Kim, Man-Bae;Gang, Dong-Geun;Jang, Sun-Hui
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.6
    • /
    • pp.17-24
    • /
    • 2010
  • As various social problems occur due to increasing traffic accidents, the government has setup and executed strong safety policies. As a result, the number of traffic accidents and the death toll have been decreasing in recent years. However, the setup and execution of the various policies for reducing traffic accidents cost much, so it is necessary to evaluate the cost-effectiveness of each policy. In the present study, enforcement by means of an unmanned over-speed enforcement system, the enforcement effect of which was proven good compared to the cost required for traffic enforcement, is compared with enforcement by policemen. As a result of the comparison, the average speed was 82.66 km/h before the use of unmanned systems and policemen; the average speed with manned enforcement was 70.57 km/h; and the average speed with unmanned systems was 67.85 km/h. The speed limit violation rate was 65% before the use of unmanned systems and policemen; 32% with manned enforcement; and 15% with unmanned systems. Considering the kinds of vehicles, the average speed and violation rate were highest among private cars, then vans, and then trucks.. Considering lanes. The accident rate was estimated based on the above results, and the input cost-to-advantage was estimated. The annual cost-to-advantage was estimated by comparing the above estimated values with the conditions before the unmanned over-speed enforcement system. Subsequently, the enforcement by policemen showed a negative advantage of 76,130,590 won, and the enforcement by the unmanned system showed a positive advantage of 38,577,670 won.