• Title/Summary/Keyword: 급수배관

Search Result 62, Processing Time 0.025 seconds

Examination on High Vibration of Recirculation System for Feed Water Piping in Combined Cycle Power Plant (복합 발전소 주급수 재순환 배관계의 고진동 현상 및 대책)

  • Kim, Yeon-Whan;Kim, Jae-Won;Park, Hyun-Gu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.648-654
    • /
    • 2011
  • The feed-water piping system constitutes a complex flow impedance network incorporating dynamic transfer characteristics which will amplify some pulsation frequencies. Understanding pressure pulsation waves for the feed-water recirculation piping system with cavitation problem of flow control valve is very important to prevent acoustic resonance. Feed water recirculation piping system is excited by potential sources of the shock pulse waves by cavitation of flow control valve. The pulsation becomes the source of structural vibration at the piping system. If it coincides with the natural frequency of the pipe system, excessive vibration results. High-level vibration due to the pressure pulsation affects the reliability of the plant piping system. This paper discusses the piping vibration due to the effect of shock pulsation by the cavitation of the flow control valves for the recirculation piping of feed-water pump system in combined cycle power plants.

  • PDF

Stress and Fatigue Evaluation of Distributor for Heat Recovery Steam Generator in Combined Cycle Power Plant (복합발전플랜트 배열회수보일러 분배기의 응력 및 피로 평가)

  • Lee, Boo-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.44-54
    • /
    • 2018
  • Stress and fatigue of the distributor, an equipment of the high-pressure evaporator for the HRSG, were evaluated according to ASME Boiler & Pressure Vessel Code Section VIII Division 2. First, from the results of the piping system analysis model, reaction forces of the tubes connected to the distributor were derived and used as the nozzle load applied to the detailed analysis model of the distributor afterward. Next, the detailed model to analyze the distributor was constructed, the distributor being statically analyzed for the design condition with the steam pressure and the nozzle load. As a result, the maximum stress occurred at the bore of the horizontal nozzle, and the primary membrane stress at the shell and nozzle was found to be less than the allowable. Next, for the transient operating conditions given for the distributor, thermal analysis was performed and the structural analysis was carried out with the steam pressure, nozzle load, and thermal load. Under the transient conditions, the maximum stress occurred at the vertical downcomer nozzle, and of which fatigue life was evaluated. As a result, the cumulative usage factor was less than the allowable and hence the distributor was found to be safe from fatigue failure.

A Review Study on Major Factors Influencing Chlorine Disappearances in Water Storage Tanks (저수조 내 잔류염소 감소에 미치는 주요 영향 인자에 관한 문헌연구)

  • Noh, Yoorae;Kim, Sang-Hyo;Choi, Sung-Uk;Park, Joonhong
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.63-75
    • /
    • 2016
  • For safe water supply, residual chlorine has to be maintained in tap-water above a certain level from drinking water treatment plants to the final tap-water end-point. However, according to the current literature, approximately 30-60% of residual chlorine is being lost during the whole water supply pathways. The losses of residual chlorine may have been attributed to the current tendency for water supply managers to reduce chlorine dosage in drinking water treatment plants, aqueous phase decomposition of residual chlorine in supply pipes, accelerated chlorine decomposition at a high temperature during summer, leakage or losses of residual chlorine from old water supply pipes, and disappearances of residual chlorine in water storage tanks. Because of these, it is difficult to rule out the possibility that residual chlorine concentrations become lower than a regulatory level. In addition, it is concerned that the regulatory satisfaction of residual chlorine in water storage tanks can not always be guaranteed by using the current design method in which only storage capacity and/or hydraulic retention time are simply used as design factors, without considering other physico-chemical processes involved in chlorine disappearances in water storage tank. To circumvent the limitations of the current design method, mathematical models for aqueous chlorine decomposition, sorption of chlorine into wall surface, and mass-transfer into air-phase via evaporation were selected from literature, and residual chlorine reduction behavior in water storage tanks was numerically simulated. The model simulation revealed that the major factors influencing residual chlorine disappearances in water storage tanks are the water quality (organic pollutant concentration) of tap-water entering into a storage tank, the hydraulic dispersion developed by inflow of tap-water into a water storage tank, and sorption capacity onto the wall of a water storage tank. The findings from his work provide useful information in developing novel design and technology for minimizing residual chlorine disappearances in water storage tanks.

The Effect of Air Chamber Placed in Water Supply Piping System (급수배관계에서 에어 챔버의 설치효과에 관한 연구)

  • 이용화;최국광
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1047-1055
    • /
    • 2002
  • The present study is to investigate the pressure wave characteristics and the absorption of the maximum and minimum pressure generated by instantaneous valve closure and opening at the end of the straightening copper Piping system with and without an air chamber. Also, life of air chamber is investigated. Experiments were conducted under the following conditions: initial pressure of 1~5 bar, flow velocity of 0.5~3.0 m/s, water temperature of$20^{\circ}C$ and air chamber volume of 45.1~449.5$cm^3$ The results of the study can be used in sizing air chamber and selecting the water hammer absorbtion apparatus.

A Study on the Leading/Unloading Time Prediction of the Ballast Tank (밸러스트 탱크의 급수/배수 시간 예측에 관한 연구)

  • Kim H. I.;Kim M. U.;Choi D. H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.33-36
    • /
    • 2004
  • The ballast tank of a ship is a system that realizes the required shipping condition and controls the draft of a ship. The loading/unloading of the ballast tank is frequently operated during navigation and the accurate prediction of the loading/unloading time is very important. A numerical algorithm that predicts the loading/unloading time of the ballast tank has been developed and applied to the prediction of the loading/unloading time of the ballast tank with various piping systems. This algorithm can be useful in optimizing the ballast tank system in early design stage.

  • PDF

Examination on Shock Vibration of Feed-Water Recirculation piping in Power Site (발전소 대형 수배관계의 충격성 이상 과도진동의 특성 고찰 사례)

  • Kim, Yeon-Whan;Yang, Gyeong-Hyeon;Bae, Si-Yeon;Yu, Jae-Myeong;Jo, Jong-Hyeon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.475-479
    • /
    • 2011
  • Leak problem with large pressure drop occurrs non-periodic shock pulsation due to the deterioration of a isolation valve in feed-water recirculation piping system. This paper discusses on the shock vibration and noise occurred due to the effect of acoustical shock pulsations by degradation of the isolation valve in a power site.

  • PDF

Experimental Study of SBLOCA Simulation of Safety-Injection Line Break with Single Train Passive Safety System of SMART-ITL (SMART-ITL 1 계열 피동안전계통을 이용한 안전주입배관 파단 소형냉각재상실사고 모의에 대한 실험적 연구)

  • Ryu, Sung Uk;Bae, Hwang;Ryu, Hyo Bong;Byun, Sun Joon;Kim, Woo Shik;Shin, Yong-Cheol;Yi, Sung-Jae;Park, Hyun-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.3
    • /
    • pp.165-172
    • /
    • 2016
  • An experimental study of the thermal-hydraulic characteristics of passive safety systems (PSSs) was conducted using a system-integrated modular advanced reactor-integral test loop (SMART-ITL). The present passive safety injection system for the SMART-ITL consists of one train with the core makeup tank (CMT), the safety injection tank, and the automatic depressurization system. The objective of this study is to investigate the injection effect of the PSS on the small-break loss-of-coolant accident (SBLOCA) scenario for a 0.4 inch line break in the safety-injection system (SIS). The steady-state condition was maintained for 746 seconds before the break. When the major parameters of the target value and test results were compared, most of the thermal-hydraulic parameters agreed closely with each other. The water level of the reactor pressure vessel (RPV) was maintained higher than that of the fuel assembly plate during the transient, for the present CMT and safety injection tank (SIT) flow rate conditions. It can be seen that the capability of an emergency core cooling system is sufficient during the transient with SMART passive SISs.

Control Modelling for Control Optimization of Gas Stripper System (탈기기 계통의 제어최적화를 위한 제어 모델링)

  • Lee, Kwang-Dae;Oh, Eung-Se;Kim, Jong-Won;Jeon, Dang-Hee;Hur, Jung-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.04a
    • /
    • pp.189-190
    • /
    • 2008
  • 원자력발전소의 탈기기 계통(Gas Stripper System)은 약 $25^{\circ}C$의 순수를 1.2기압, $105^{\circ}C$ 상태를 거쳐서 가스가 없는 상태(탈기)로 만들어 주는 계통이다. 탈기 상태를 유지하면서 지속적으로 순수를 만들기 위해서 본 계통에는 수위와 압력 제어루프가 있다. 탈기 상태에서는 탈기기 탱크내의 유체 상태가 이상(Two Phase)이기 차가운 급수를 사용한 수위와 압력 제어가 어렵다. 본 논문에서는 모델 기반으로 제어 최적화를 하기 위하여 제어 구성 요소들에 대한 제어 모델링 및 검증 과정을 기술한다. 제어모델링은 일반적으로 Parameter Identification 기법을 적용하지만, 유체역학 수식 모델, 운전 데이터, 탱크와 배관의 설계 자료 등을 이용한 경험적 방법을 적용하였으며 운전 데이터를 사용하여 검증하였다.

  • PDF

Inch-Worm Robot with Automatic Pipe Tracking Capability for the Feeder Pipe Inspection of a PHWR (중수형 원자로 급수 배관 검사용 자율 주행형 자벌레 로봇)

  • Choi, Chang-Hwan;Park, Byung-Suk;Jung, Hyun-Kyu;Jung, Seung-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.2
    • /
    • pp.125-132
    • /
    • 2008
  • This paper describes a mobile inspection robot with an automatic pipe tracking system for a feeder pipe inspection in a PHWR. The robot is composed of two inch worm mechanisms. One is for a longitudinal motion along a pipe, and the other is for a rotational motion in a circumferential direction to access all of the outer surfaces of a pipe. The proposed mechanism has a stable gripping capability and is easy to install. An automatic pipe tracking system is proposed based on machine vision techniques to make the mobile robot follow an exact outer circumference of a curved feeder pipe as closely as possible, which is one of the requirements of a thickness measurement system for a feeder pipe. The proposed sensing technique is analyzed to attain its feasibility and to develop a calibration method for an accurate measurement. A mobile robot and control system are developed, and the automatic pipe tracking system is tested in a mockup of a feeder pipe.

Case Study of Pipe Leak Detection Using Artificial Intelligence (인공지능(AI) 기반 상수도 누수탐사 사례 분석)

  • Tae Nam Moon;Chang Gun Shin;Bo Hyang Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.496-496
    • /
    • 2023
  • 상수도관의 노후화 등으로 발생하는 누수는 안정적인 급수운영을 저해하고 경제적 손실을 발생시킬 뿐만 아니라 지반 침하 등 2차 피해가 발생할 수 있다. 상수도관 누수는 배관 내·외부 부식으로 발생하는 핀홀(Pin Hole)로 인한 관통누수, 강관 용접 시 발생하는 시공불량, 볼트 및 고무패킹 등 부자재의 노후화, 굴착 등 작업에서 발생하는 물리적 충격 등 여러 원인으로 발생할 수 있다. 상수도관에서 누수가 발생할 경우, 관 내부수가 관 밖으로 유출되어 발생하는 파열음, 유출수와 지반과의 마찰로 인한 진동 및 소음 등이 발생할 수 있다. 청음식, 상관식 누수탐사와 같은 기존 누수탐사 방식은 전문가의 경험에 대한 의존도가 매우 높으며, 기존 장비의 특성상 비금속관 및 대구경관 등 특정 환경에서는 적용이 어려우며, 효율적인 탐사가 쉽지 않은 실정이다. 이에 대한 해결책으로 본 논문에서는 상수도 누수가 의심되는 구간을 대상으로 실시간 누수음 데이터 수집 및 인공지능(Artificial Intelligence) 분석을 실시하여 기존 조사방법보다 효율적이고 신뢰성 있는 누수탐사를 수행한 사례를 분석하고자 한다.

  • PDF