• Title/Summary/Keyword: 급수계통

Search Result 67, Processing Time 0.036 seconds

Comparative Study on Disinfection Efficiency of Chlorine and Chloramine in the Distribution Systems (배·급수계통에서 유리염소와 클로라민의 소독효과에 관한 비교연구)

  • Choi, Yong-Il;Nam, Sang-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.2
    • /
    • pp.82-88
    • /
    • 1999
  • This study was to evaluate disinfection efficiency of chlorine and chloramine as secondary disinfectants in the distribution systems. Indicator organism, HPC in the suspended and attached were measured for copper, galvanized steel, PVC, and carbon steel pipes. For suspended microorganism, the PVC pipe was markedly dense among the assessed pipe materials. The attached microorganism was markedly equivalent roughness of pipe materials. In copper and galvanized pipes, chloramine was more effective that free chlorine to disinfect suspended microorganism in the contact time of 2 hours. The contact time for the 99% inactivation of suspended microorganism by chloramine was longer than that of free chlorine. Regardless of pipe materials, chloramine was effective on both disinfection efficiency and 99% inactivation time for attached microorganism. In conclusion, chloramine which is good disinfectant for long contact time was recommended as secondary disinfectant in distribution system.

  • PDF

Study on The Measurement of Corrosion Product Concentration in The Feed Water System of A Power Plant (발전소 급수계통 부식생성물 농도 측정에 관한 연구)

  • Moon, Jeon Soo;Lee, Jae Kun
    • Corrosion Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.151-155
    • /
    • 2011
  • The iron oxide particles could be resulted from the corrosion of the circulating water system of a power plant. Because it may be one of the trouble materials which affect the power generation efficiency due to the deposition on steam generator tube and turbine blade, the continuous observation of its concentration is very important. The laser induced break-down detection (LIBD) technology was applied to monitor continuously the concentration of corrosion products with the detection limit of ppb level. The measurement system consists of a Nd:YAG pulsed laser, a polarizing beam splitter, a flow-type sample cell, an acoustic emission sensor, a high speed data acquisition board, a personal computer, etc.. The performance test results confirmed that this technology can be effective to monitor the corrosion product concentration of the circulating water system of a power plant.

Study on the Need of Deaerator Installation in Nuclear Power Plant (급수계통 탈기기 필요성 검토)

  • Choi, Young-Boo;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.189-192
    • /
    • 1998
  • This paper presents the basis for the need of feed-water deaerator installation in nuclear power plant and has been conducting reviews to understand the mechanism of dissolved oxygen(DO) formation as well as removal. DO is produced by feedwater make-up, air inleakage in vacuum system and condensation in condenser, etc. and removed by mechanical method and chemical method. DO has an influence on S/G in the form of denting, pitting, fretting, etc. DO control by deaerator has an great effect on the integrity of S/G in nuclear power plant.

  • PDF

Effects of Deaerator in Feedwater System on Steam Generator in Nuclear Power Plant (원자력 발전소 급수계통 탈기기가 증기발생기에 미치는 영향)

  • Choi, Young-Boo;Kim, Si-Moon;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.403-405
    • /
    • 1999
  • Dissoved oxygen(DO) control by deaerator has a great effect on the integrity of S/G in nuclear power plant. The goal of this study based on the theoretical basis and the extensive surveys is to identify the effect of deaerator in feedwater system on steam generator to clear the need of installation of deaerator. In addition, this paper discusses the review to understand the mechanism of DO formation as well as removal. The conclusion is that the installation of deaerator improve the integrity of S/G and is contributed to the whole nuclear power plant safety.

  • PDF

Control Modelling for Control Optimization of Gas Stripper System (탈기기 계통의 제어최적화를 위한 제어 모델링)

  • Lee, Kwang-Dae;Oh, Eung-Se;Kim, Jong-Won;Jeon, Dang-Hee;Hur, Jung-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.04a
    • /
    • pp.189-190
    • /
    • 2008
  • 원자력발전소의 탈기기 계통(Gas Stripper System)은 약 $25^{\circ}C$의 순수를 1.2기압, $105^{\circ}C$ 상태를 거쳐서 가스가 없는 상태(탈기)로 만들어 주는 계통이다. 탈기 상태를 유지하면서 지속적으로 순수를 만들기 위해서 본 계통에는 수위와 압력 제어루프가 있다. 탈기 상태에서는 탈기기 탱크내의 유체 상태가 이상(Two Phase)이기 차가운 급수를 사용한 수위와 압력 제어가 어렵다. 본 논문에서는 모델 기반으로 제어 최적화를 하기 위하여 제어 구성 요소들에 대한 제어 모델링 및 검증 과정을 기술한다. 제어모델링은 일반적으로 Parameter Identification 기법을 적용하지만, 유체역학 수식 모델, 운전 데이터, 탱크와 배관의 설계 자료 등을 이용한 경험적 방법을 적용하였으며 운전 데이터를 사용하여 검증하였다.

  • PDF

A Study on Uncertainty and Sensitivity of Operational and Modelling Parameters for Feedwater Line Break Analysis (급수관 파열사고 해석에 대한 운전변수와 모형변수의 불확실성 및 민감도 연구)

  • Lee, Seung-Hyuk;Kim, Jin-Soo;Chang, Soon-Heung
    • Nuclear Engineering and Technology
    • /
    • v.19 no.1
    • /
    • pp.10-21
    • /
    • 1987
  • Uncertainty analysis of the FLB accident is performed for KNU-1 using the response surface methodology and Monte Carlo simulation. The FLB analyses using the RELAP4/Mod6 were performed a number of times to generate the data base for the uncertainty analysis, along with the EM calculation for comparison purpose. Two kinds of input sets are utilized for response surface method to investigate and compare the effects of the uncertainty of input variables on the RCS peak pressure following a FLB. The first set is composed of six major plant operational parameters and the second set is composed of five major modelling parameters. It is found through the analysis of results that the uncertainties of modelling parameters have more influence on the RCS peak pressure than the uncertainties of plant operational parameters and that the extra margin of 9% of peak pressure is gained. And one of the assumptions of EM calculation, which is usually accepted as conservative is found to be erroneous, that is, the initial core inlet temperature is found to act negatively on the RCS pressure following a FLB.

  • PDF

Design of Multivariable 2-DOF PID for Electrical Power of Flow System by Neural Network Tuning Method (신경망 튜우닝에 의한 유량계통 동력 제어용 다변수 2-자유도 PID의 제어기 설계)

  • 김동화
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.78-84
    • /
    • 1998
  • The fluid system such as, the quantity control of raw water, chemicals control in the purification, the waste water system as well as in the feed water or circulation system of the power plant and the ventilation system is controlled with the valve and moter pump. The system's performance and the energy saving of the fluid systems depend on control of method and delicacy. Until, PI controller use in these system but it cannot control delicately because of the coupling in the system loop. In this paper we configure a single flow system to the multi variable system and suggest the application of 2-DOF PID controller and the tuning methods by the neural network to the electrical power of the flow control system. the 2-DOF controller follows to a setpoint has a robustness against the disturbance in the results of simulation. Keywords Title, Intelligent control, Neuro control, Flow control, 2 - DOF control., 2 - DOF control.

  • PDF

Construction of integrated DB for domestic water-cycle system and short-term prediction model (생활용수 물순환 계통 통합 DB 및 단기예측모형 구축)

  • Seungyeon Lee;Sangeun Lee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.362-362
    • /
    • 2023
  • 한정된 수자원의 이용 및 관리로 매년 물 부족과 물 배분 의사결정 문제가 발생하고 있다. 50년간(1965~2014년) 수자원의 총량은 약 1.2배 증가한 반면 인구수 약 1.8배, 생·공·농업용수의 수요는 약 5배가 증가(국회입법조사처, 2018) 했을 뿐 아니라, 기후변화의 영향으로 인한 강수량의 변화와 지역별 편차가 커져 지속가능한 물관리 필요성이 증대되고 있다. 따라서 효율적인 물관리를 위해서는 관리부처가 분절되어 있는 물순환 계통의 데이터를 통합하는 것이 우선시되어야 하고 이를 통해 물순환 모니터링/평가/예측 기술을 개발할 수 있다. 본 연구에서는 생활용수 물순환 계통 통합 DB를 정의 및 구축하였다. 도시의 관점에서 물순환 시스템을 순차적으로 물 유입(수원~취수장)/전달(정수장~급수지역)/유출(하(폐)수처리장~방류구)의 개념으로 설정하고 DB정의서를 마련하였다. 연구대상지는 가뭄이 장기화가 되고 있는 전라남도중 물순환 계통이 비교적 단순한 네트워크로 형성되어 있는 함평군 도시지역으로 선정하였다. 연구 기간은 총 5년(2017년 1월 1일~2021년 12월 31일)이고 일 단위 실계측자료 위주의 원자료를 구축하였다. 이를 이상치 탐지, 제거, 대체의 과정을 거쳐 품질 보정하고 정제된 시계열 자료에 대한 특성 분석을 하였다. 그 결과, 물순환 계통 내 주요 지점 간의 상관관계 및 지연시간을 통한 물흐름의 시계열적 특성을 파악할 수 있었으며 모형의 적합도를 판단하는 데 활용되는 통계량과 유의미하지 않은 잔차의 자기상관성을 볼 때 물 유입-전달-유출의 단기 예측을 위한 ARIMA(Auto-regressive Integrated Moving Average) 모형의 구축도 가능할 것으로 판단되었다. 다만 여름철 발생하는 방류량의 첨두값을 설명하기 위해서는 강우에 의한 불명수 발생으로 증가하는 방류량을 묘사할 수있어야 하므로 향후에는 물순환계통 외 해당 지역의 불명수(강우 효과)도 하수 방류량의 주요 입력 요인으로 추가 검토할 필요가 있다.

  • PDF

A Study of Thermal Power Plant Feedwater System with Modeling and L.Q.Controller (화력발전소 보일러 급수제어 계통의 모델링과 L.Q. 제어기 적용에 관한 연구)

  • 서진헌;황재호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.12
    • /
    • pp.1281-1287
    • /
    • 1990
  • A new thermal power plant feed-water system model, which is based on Astrom, is presented. Astrom's model has some difficulties in applying to practical systems because it is not able to measure the heat and energy transfer loss. Hence, in order to make up for these difficulties, the Gas State Equation is added to the model. Computer simulations are performed to show the validity of the new model at thermal power plant with practical boiler operating data and to verify the L.Q. controller effect on boiler drum level system.

촉매수지식 용존산소 제거설비 - 개발경위와 앞으로의 활용전망

  • 이창소
    • Nuclear industry
    • /
    • v.16 no.2 s.156
    • /
    • pp.47-55
    • /
    • 1996
  • 원자력발전소 2차 계통수중의 용존산소는 증기발생기 뿐만 아니라 터빈 급수가열기와 응축기 등 주요설비 부식의 직접적인 원인으로서, 원자력발전의 경제성 저하 및 원전설비의 안전성에 심각한 문제를 야기시키고 있다. 한국정수공업(주)는 최근 $\ulcorner$촉매수지식 용존산소 제거설비$\lrcorner$를 한국원자력연구소의 기술지원 아래 연구$\cdot$개발하여 고리원자력 1호기에 설치$\cdot$운용중에 있다. 그 개발경위와 활용전망 등을 알아본다.

  • PDF