• Title/Summary/Keyword: 급기속도

Search Result 22, Processing Time 0.024 seconds

Combustion Characteristics of Methane-Air Mixture in a Constant Volume Combustion Chamber(1): Homogeneous Charge (정적연소기에서의 메탄-공기 혼합기의 연소특성(1) : 균질급기)

  • 최승환;전충환;장연준
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.3
    • /
    • pp.48-57
    • /
    • 2003
  • A cylindrical constant volume combustion chamber was used to investigate the flow characteristics at spark plug and the combustion characteristics of homogeneous charge methane-air mixture under various initial pressure, excess air ratio and ignition times in quiescent mixture. The flow characteristics such as mean velocity and turbulence intensity was analyzed by hot wire anemometer. Combustion pressure development measured by piezoelectric pressure transducer and flame propagation acquired by ICCD camera were used to investigate the effect of initial pressure, excess air ratio and ignition times on pressure, combustion duration, flame speed and burning velocity. Mean velocity and turbulence intensity had the maximum value at 200 or 300ms and then decreased to near 0 value gradually after 3 seconds. Combustion duration, flame speed and burning velocity were observed to be promoted with excess air ratio of 1.1, lower initial pressure and ignition time of 300ms.

A Study on the Fire Door Performance Method of Pressurized Room for Special Evacuation Stairwells (특별 피난계단의 부속실 출입문 성능 방안에 관한 연구)

  • You, Woo-Jun;Nam, Jun-Seok;Ryou, Hong-Sun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.12-16
    • /
    • 2010
  • 본 연구에서는 건설현장의 특별 피난계단 출입문 크기와 구조의 다양성을 고려한 자동폐쇄장치의 설계방안을 제시하였다. 이를 위해서 급기가압실의 방연풍속, 누설량 그리고 송풍기의 용량이 일정한 경우 출입문이 폐쇄되기 위한 힘의 상관관계를 회전각도와 회전속도의 변화에 따라서 분석하였으며, 방화문의 폭이 1,100 mm, 1,300 mm 인 경우 각각에 대해서 개방력과 폐쇄력을 측정하였다. 그 결과 현장 조건을 만족할 수 있는 자동폐쇄장치에 의한 방화문의 폐쇄조건 및 회전각도와 회전속도의 변화를 고려한 개방력과 폐쇄력의 최적 설계범위가 존재함을 확인하였다.

  • PDF

The Analysis on the Effect of Supply Air Velocities by Location of Supply Air Damper on the Performance Efficiency of the Smoke Exhaust Systems (공기유입구 위치에 따른 유입공기의 풍속이 배연시스템 성능효율에 미치는 영향 연구)

  • Yeo, Yong-Ju;Lim, Chae-Hyun;Kim, Hak-Jung;Kim, Bum-Gyu;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.20-27
    • /
    • 2010
  • In smoke control systems the amount of air supply is almost the same as that of smoke exhaust. This study analyzed the effect of supply air velocity on the smoke exhaust behavior using FDS tool. The results showed that fire plume can be disheveled by the rapid air velocities developed when the air supply inlet is located near the fire plume. Disheveled smoke caused the rapid descent of smoke layer level and the reduced visibility. To increase the efficiency of smoke exhaust systems supply air inlet should be located sufficiently far from the location of the fire plume.

Reaction Rate Analysis of CO2 Gasification for Indonesian Coal Char at High Temperature and Elevated Pressure (고온, 고압조건에서의 인도네시아 석탄촤의 CO2 가스화 반응)

  • Lisandy, Kevin Yohanes;Kim, Ryang-Gyoon;Hwang, Chan-Won;Jeon, Chung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.9
    • /
    • pp.781-787
    • /
    • 2014
  • A pressurized wire mesh heating reactor (PWMR) can provide high pressure and temperature experimental conditions up to 50 atm and 1750 K, respectively. This equipment was developed to evaluate the intrinsic reaction kinetics of $CO_2$ gasification. A PWMR utilizes a platinum (Pt) wire mesh resistance to generate heat with a direct current (DC) electricity supply. This DC power supply can then be controlled by computer software to reach the exact expected terminal temperature and heating period. In this study, BERAU (sub-bituminous Indonesian coal) was pulverized then converted into char with a particle size of $90-150{\mu}m$. This was used in experiments with various pressures (1-40 atm) and temperatures (1373-1673 K) under atmospheric conditions. The internal and external effectiveness factor was analyzed to determine the effects of high pressure. The intrinsic reaction kinetics of BERAU char was obtained using $n^{th}$ order reaction rate equations. The value was determined to be 203.8kJ/mol.

Numerical simulation of turbulent air-flow in a closed engine room with heat source in a ship (열원이 있는 밀폐된 선박 기관실에서의 난류기류에 관한 수치적 연구)

  • 박찬수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.100-107
    • /
    • 1998
  • Ventilation of the marine engine room is very important for the health of the workers as well as the nomal operation of machines. To find proper ventilation conditions of this engine room, numerical simulation with standard k-.epsilon. model was carried out. In the present study, the marine engine room is considered as a closed space with a heat source and forced ventilation ducts. The injection angle of air supply is found to be important. Injection with downword angle depresses recirculation flow, causing a strong steam in the wider space of the room. Ventilation and removal of the released heat are promoted with this pattern. There is a possibility of local extreme heating at the upper surface of engine when supply and exhaust ports of air are in bilateral symmetry. The effect of the increase of exhaust port area on ventilation decreases as the number of supply port increases.

  • PDF

Characteristices of Temperature Distribution in a Closed Space with Heat Source and Porous Horizontal Partition (유공성 수평격판을 가진 열원이 있는 밀폐공간내의 온도분포 특성)

  • Park, Chan-Su;Cho, Dae-Hwan;Jeon, Cheol-Kyun
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.3B
    • /
    • pp.29-37
    • /
    • 1999
  • Ventilation of the marine engine room is very important for the health of the workers as well as the normal operation of machines. To find proper ventilation conditions of this engine room, numerical simulation with standard k-${\epsilon}$ model was carried out. In the present study, the marine engine room is separated to two floors with porus horizontal partition and considered as a closed space with a heat source and forced ventilation ducts. The porosity of horizontal partition is found to be important. For the engine room with 2 supply ports & 2 exhaust ports, the increasing of the porosity of horizontal partition is effective to reduce the recirculation flow zone in the second floor. When the engine room is ventilated with three supply air ports & one exhaust port, the increasing of the porosity of horizontal partition is effective to reduce the recirculating flow zone in the exhaust air area, but there is a possibility of local extreme heating at the lower side of engine near bottom.

  • PDF

Stack Effect Mitigation Methods in Exit Route of High-rise Building (고층 건축물 피난경로의 연돌효과 저감 방안)

  • Kim, Jin-Soo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.284-288
    • /
    • 2010
  • Length of staircase get longer and evacuation load get heavier in proportion to the building height. Therefore evacuation time could be considered proportional to square of building height. While smoke spreads vertically so rapidly, evacuation speed is too slow, therefore the reasonable measure for the safe of egress route is urgent. Existing pressurizing smoke control system of vertical exit route is seriously limited in function under the stack effect in winter. Stack effect in winter could be overcome with the methods of opening the staircase outward or letting airflow be free between staircase and outside.

  • PDF

Analysis of Productivity in Rice Plant -IV. Sink-filling rate and sink-source relation (벼의 생산력 분석(分析) -IV. 수기(受器)의 충전속도(充塡速度)와 수기(受器)-급기(給器) 관계(關係))

  • Park, Hoon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.6 no.2
    • /
    • pp.95-105
    • /
    • 1973
  • Sink (grain)-filling rates of IR667 line (Suwon 213 and 214) and local leading varieties (Jinheung and Paldal) were investigated in relation to sink-source ratio, sink-source distance, forms of photosynthates, and weather factors. The results are as follows. 1. IR667 line have higher maximum filling rate (g. grain/day. ear) and shorter duration to reach maximum filling rate than local varieties. The curve pattern of sink-filling rate was high and steep type in IR667 line and low and broad type in local varieties. 2. Weather factors seem to give little effect on the curve pattern of sink-filling rate. 3. The functional sink-source distance (actual sink-source distance multiplied by the contribution rate of leaf for grain production) was shorter in upper leaves (flag and 2nd leaf) for IR667 line, the upper leaf-dependent type in grain production, and was longer in lower leaves (3rd and 4th) for local varieties, the lower leaf-dependent type. Specially short first internode from top may contribute to the upper leaf depencency of IR667 line. 4. According to free sugar-starch ratio (sugar/starch) in the culm and leaf sheath IR667 line could be classified as the high sugar type and the local varieties as the high starch type. The ratio of transportable form (sugar) to non transportable photosynthate (starch) seems to relate with sink-filling rate. And high sugar type is expected to have higher efficiency for grain production in view of energy balance. 5. A hypothesis that the higher in the uniformity within the series of productive structure the more efficient in grain production is proposed and discussed in relation to productivity. 6. According to the pattern of percent nutrient retention of each leaf blade IR667 showed the central retention type and Jinheung showed the apical retention type and each retention type appears to be a cause of each canopy conservation pattern. 7. From the content and percent distribution of nutrient in various organ IR667 could be classified as the leaf sheath dominant type and Jinheung as the leaf blade dominant type. 8. The fact that the greater the percent translocation of nutrient into grain the greater the percent nutrient retention in leaf blade was held between nitrogen and phosphorus within a variety and between varieties within a nutrient (N, P or K).

  • PDF

Study of Smoke Behavior and Differential Pressure in the Refuge Safety Area According to Damper Capacity of Smoke Control (제연댐퍼 송풍량에 따른 피난 안전 구역 차압 및 연기 거동 특성 연구)

  • Lee, Jae-Bin;Moon, Joo-Hyun;Lee, Seong-Hyuk;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.103-109
    • /
    • 2011
  • In this study, we calculated the smoke movement at the fire area of the refuge floor which has the refuge safety area in case of fire in the high rise building by using a computational fluid dynamics (CFD) code of FLUENT (ver. 13.0). The buoyancy plume was applied using the temperature and flow velocity which represent 10 MW heat release rate in order to describe the fire, and the smoke movement was predicted using a species conservation equation. The pressurization system of smoke control was adopted with smoke control damper in refuge safety area, at the result, it is confirmed that the damper capacity was enough to smoke control in which the flow rate of supply was applied 25 $m^3/s$ in the case of the door at fire area opened only, and 50 $m^3/s$ in the doors at the fire area and lobby both opened case. They were satisfied in NFSC 501-A. Even though the door of fire area closed, there were smoke leakages at the gap between the door and wall. In addition, the refugee could be isolated in the fire area when the door of fire area closed during smoke control in the case of using the high damper flow rate of supply, 50 $m^3/s$. Therefore the proper damper flow rate of supply are needed in order to prevent the damage of refugee and this study proposes the suitable condition of damper capacity according to refuge scenario.

A Study on the Determination of the Seasonal Heat Transfer Coefficient in KURT Under Forced Convection (강제대류시 계절에 따른 KURT 내 열전달계수 결정에 관한 연구)

  • Yoon, Chan-Hoon;Kwon, Sang-Ki;Hwang, In-Phil;Kim, Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.3
    • /
    • pp.189-199
    • /
    • 2010
  • In a high-level waste (HLW) repository, heat is generated by the radioactive decay of the waste. This can affect the safety of the repository because the surrounding environment can be changed by the heat transfer through the rock. Thus, it is important to determine the heat transfer coefficient of the atmosphere in the underground repository. In this study, the heat transfer coefficient was estimated by measuring the indoor environmental factors in the Korea Atomic Energy Research Institute Underground Research Tunnel (KURT) under forced convection. For the experiment, a heater of 5 kw capacity, 2 meters long, was inserted through the tunnel wall in the heating section of KURT in order to heat up the inside of the rock to $90^{\circ}C$, and fresh air was provided by an air supply fan connected to the outside of the tunnel. The results showed that the average air velocity in the heating section after the provision of the air from outside of the tunnel was 0.81 m/s with the Reynolds number of 310,000~340,000. The seasonal heat transfer coefficient in the heating section under forced convection was $7.68\;W/m^2{\cdot}K$ in the summer and $7.24\;W/m^2{\cdot}K$ in the winter.