• Title/Summary/Keyword: 금속 시편

Search Result 501, Processing Time 0.032 seconds

Fatigue Crack Growth Behavior of a Magnesium-Based Composite (마그네슘 금속복합재의 피로균열거동해석)

  • Kim, Doo Hwan;Park, Yong Gul;Kim, Sung Hoon;Han, Suk Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.4 s.33
    • /
    • pp.515-521
    • /
    • 1997
  • The effects of heat treatment and fiber orientation on tensile strength and fatigue behavior were studied in a continuously reinforced. magnesium-based composite Following an earlier TEM investigation, specimens were thermally aged to modified the interfacial zone between the alumina fibers and the magnesium alloy matrix. From the tensile experimental results, the ultimate tensile strength of the aged specimens were lower than that of the as-fabricated due to weak fiber-matrix interfacial strength with chemical reaction during the thermal processing. The fatigue crack growth experiments were conducted with specimens having the fiber orientation normal to the crack growth direction (longitudinal) and also specimens with the fibers oriented parallel to the crack growth direction(transverse). A comparison of the fatigue crack growth behavior indicates that aged longitudinal specimens are more resistant to fatigue crack growth the as-fabricated longitudinal specimens. Conversely, as-fabricated transverse specimens are more resistant to fatigue crack growth than aged transverse specimens.

  • PDF

Effect of universal primer on shear bond strength between resin cement and restorative materials (다용도 프라이머가 레진 시멘트와 수복재의 전단 결합 강도에 미치는 영향)

  • Kim, Na-Hong;Shim, June-Sung;Moon, Hong-Suk;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.112-118
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the difference in shear bonding strength between resin cements to dental materials when a universal primer (Monobond plus) was applied in place of a conventional primer. Materials and methods: Four groups of testing materials: gold alloy (Argedent Euro, n = 16), non precious metal (T-4, n = 20), zirconia (Cercon, n = 20) and glass ceramic (IPS e.max press, n = 20), were fabricated into discs, which were embedded in an acrylic resin matrix. The gold alloy specimens were airborne-particle abraded, 8 of the specimens were coated with Metal primer II, while the remaining 8 specimens were coated with Monobond plus. The non precious and zirconia specimen were airborne-particle abraded then, the control group received Alloy primer coating, while the other was coated with Monobond plus. Glass ceramic specimens were etched. 10 specimens were coated with Monobond-S and the remaining specimens were coated using Monobond plus. On top of the surface, Multilink N was polymerized in a disc shape. All of the specimens were thermal cycled before the shear bonding strength was measured. Statistical analysis was done with Two sample $t$-test or Mann-Whitney U test (${\alpha}$=.05). Results: There were no significant differences in bonding strength depending on the type of primer used in the gold alloy and glass ceramic groups ($P$>.05), however, the bonding strengths of resin cements to non precious metal and zirconia groups, were significantly higher when the alloy primer was used ($P$<.05). Conclusion: Within the limitations of this study, improvement of universal primers which can be applied to all types of restorations is recommended to precious metals and zirconia ceramics. But, the bond strengths of non precious metals and zirconia ceramics were significantly lower when compared to a 10-MDP primer. More research is needed to apply universal primers to all types of restorations.

Effects of Wood Materials on Metal Corrosion - Oddy test - (나무재료가 금속부식(金屬腐蝕)에 미치는 영향(影向) - Oddy test -)

  • Lee, Sungeun;Roh, Hyunsook;Yi, Yonghee
    • Conservation Science in Museum
    • /
    • v.5
    • /
    • pp.31-36
    • /
    • 2004
  • The purpose of this experiment was to check the effects on metal corrosion of the 6 types of tree (Ash tree, Japanese cedar, black walnut, western hemlock, paulownia coreana and maple) which are currently being used, or the use of which is under study, by the Museum. As a method of test, an Oddy Test was conducted where the materials to be tested and the metal test piece are exposed to a specified temperature and humidity for a long period of time and the effects of materials on the test piece are observed. The results of the Oddy Test conducted on all 6 types of tree showed slight difference in the form of metal corrosion, and except for the blank, corrosion occurred on the entire surface of most iron (Fe) and lead (Pb) test pieces. Minor level of discoloration was noted in all test pieces of copper (Cu) even though different levels.

The metal corrosion caused by museum indoor air pollutants (박물관 실내 대기오염물질에 의한 금속 부식 영향)

  • Kang, Dai-Ill
    • Journal of Conservation Science
    • /
    • v.22
    • /
    • pp.5-14
    • /
    • 2008
  • The effect of air pollutants coming from internal museum materials such as wood-based products and cements on metal corrosion have been investigated. The Oddy test and the Chamber test was employed as a corrosion test. The metal pieces after the Oddy test had different corrosion types caused by the internal museum materials. The most effective wood based product was 18T HS(E0) and 9mm plywood(F0,E0). Iron(Fe) and copper(Cu) also bronze of the Chamber test had corrosion caused by Formic acid, Acetic acid, and Acetaldehyde. The packing materials in high humidity had caused more corrosion on the surface of the metal pieces than in low humidity.

  • PDF

MICROSTRUCTURE OF COMBINATION CLASP JOINTS IN REMOVABLE PARTIAL DENTURE (가철성(可撤性) 국부의치(局部義齒)에서 연합(聯合) Clasp 연결부위(連結部位)의 미세구조(微細構造))

  • Son, Han-Kee;Kim, Tae-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.22 no.1
    • /
    • pp.123-132
    • /
    • 1984
  • To evaluate the microstructure of various combination clasp joint in removable partial denture, the auther selected framework alloys (Type IV gold alloy, Dentaurium, Ticonium 100) and wrought wires (gold alloy, Ticonium) for this study. Twelve series of combination joints were made by investment soldering technic and wrought wire embedded casting technic. All specimens were cut cross-sectionally and longitudinally, then examined with metallurgical microscope. The results were as follows; Some diffusion was observed in the properly constructed combination clasp joints. In soldered joints, empolying precious alloys were more favorable than non-precious alloys. In castion joints, assemblage of same alloy between framework and wrought wire was superior to other groups. Some impurities were observed in both joints by technical problems.

  • PDF

Evaluation of shear bond strength between metal core fabricated by 3D printing and dental porcelain (3D printing으로 제작된 금속 코어와 치과용 도재 간의 전단결합강도 평가)

  • Jung, Jae-Kwan;Lee, Su-Ok;Kim, Ki-Baek
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2585-2592
    • /
    • 2015
  • The purpose of this study was to evaluate the shear bond strength between metal core fabricated by 3D printing and dental porcelain. Thirty metal cores were fabricated(cast 15ea, 3D printing 15ea). The porcelain for each group was builded to the metal core. Sample was loaded to shear force(crosshead speed 1mm/min) in a universal material testing machine. The fracture samples were analyzed failure aspect. The means were statistical analyzed using by Mann-whitney test(${\alpha}=0.05$). The period of experimental(metal cores fabrication, dental porcelain build up, data analysis, statistical analysis, failure aspect analysis and others) for this study took six months. The $mean{\pm}SDs$ of shear bond strength was $50.14{\pm}1.60MPa$ for the cast group, and $54.36{\pm}3.18MPa$ for the 3D printing group(p=0.035). The failure aspect showed mixed failure. As a results, metal cores fabricated by 3D printing method were clinically acceptable range.

Damage Characteristics of Metal Materials According to the SO2 Concentration (이산화황 농도에 따른 금속시편의 손상 특성)

  • Kim, Myoung Nam;Lim, Bo A;Shin, Eun Jeong;Lee, Sun Myung
    • Korean Journal of Heritage: History & Science
    • /
    • v.46 no.1
    • /
    • pp.176-187
    • /
    • 2013
  • A study has been carried out on metal materials in order to identify the quantitative relation between the concentration and damage characteristics after evaluation of the damage characteristics according to the $SO_2$ concentration. The prepared metal samples, which were categorized according to the material (silver, copper, iron, lead, brass) were exposed to 0.01, 0.12, 1, 10, 100, 1,000, and 5,000ppm of $SO_2$ for 24 hours and the optical, physical, chemical deterioration rates both before and after testing were evaluated. The results showed optical deterioration, a loss of gloss on silver specimen with $SO_2$ 100ppm, an increase of color difference on brass, iron, copper and lead specimens with $SO_2$ 5,000ppm, as well as physical changes such as an increase of thickness and corrosion rate on iron sample with $SO_2$ 5,000ppm. In the case of chemical changes such as an increase sulfate ion ($SO{_4}^{2-}$) concentration and decrease of pH on iron and brass specimens were identified. These results suggest that $SO_2$ 100ppm caused clear optical deterioration on some metals such as silver and physicochemical and optical deterioration were identified at $SO_2$ 5,000ppm regardless of metal type. Also, It was concluded that iron and brass are the most susceptible of the metal specimens to $SO_2$.

Characteristics of Metal Sensor using Variable Frequency (가변주파수형 금속감지 센서의 특성)

  • Choi, Kyoo-Nam
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.2
    • /
    • pp.161-166
    • /
    • 2014
  • This Electromagnetic metal piece detection sensor, having high sensitivity even under high humidity and dust density, using LVDT was investigated. Metal detection characteristics using phase detection method, for 3 frequencies covering ELF and LF band, were experimentally measured. It was found that the sensitivity for metal and animal food, in which metal piece was included, was exponentially increased as frequency increased. Reducing cutoff frequency of LPF after PD was found to be effective to proportionally increase sensitivity. Also the sensitivity of metal piece detection was enhanced by optimizing BPF bandwidth and SNR. Metal piece detection limit using available ferrous test samples was found to be 0.7mm diameter from the experiment using 50kHz, in ELF band, which was known to have better selectivity to animal food. is an example of ABSTRACT format.

Surface Characteristics of Metallic 3D Printed Dental Framework (금속 3D printing으로 제작한 치과보철물의 표면특성)

  • Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.21-21
    • /
    • 2018
  • 다양한 소재(금속, 세라믹, 고분자 소재 등)들이 3차원 형상기반 적층제조법에 적용되고 있는데, 금속 소재를 이용하여 3D 프린팅 법으로 치과용 수복물을 제조하는 연구가 많이 보고되고 있다. 하지만, 티타늄 또는 티타늄 합금 분말을 이용하여 3D 프린팅 법으로 제작한 치과용 보철물에 관한연구 보고는 많지 않다. Kanazawa 등 (2014)은 Ti-6Al-4V 합금분말을 이용하여 SLM법으로 총의치 용 framework를 제작하여 주조법으로 제작한 것과 비교 평가하였고, Mangano 등(2013)은 Ti-6Al-4V 합금분말로 지름이 작은 일체형 (1-piece narrow-diameter) 임플란트를 SLS법으로 제작하여 16명의 환자에게 식립한 다음, 2년간 관찰하였고, Mangano 등 (2014)은 cone-beam computed tomography (CBCT) data를 3D이미지로 변환시켜 DLMS법으로 치근 형상의 임플란트를 제작하여 15명의 환자에게 식립한 다음, 1년간 관찰하였다. 또한 서울대학교 및 연세대학교 치과생체재료과학교실 (2016)에서는 3D 프린팅 법으로 제작한 티타늄 시편과 기계 가공한 티타늄 시편의 물성을 비교하였다. 그러나 티타늄 합금 분말을 이용하여 3D 프린팅 법으로 제작한 치과용 보철물을 실제 임상에 적용하는 단계에서 기존 기계가공 방식으로 제작한 티타늄 보철물과 3D 프린팅 법으로 제작한 티타늄 보철물의 물성과 표면특성을 다양하게 비교 평가하는 것이 필요하여 본 연구에서는 3D 프린팅 법으로 제작한 티타늄 시편과 기계 가공한 티타늄 시편의 물성특성과 표면특성을 비교하여 조사하였다.

  • PDF

Improved drop impact reliability of Sn-Ag-Cu solder joint using Cu-Zn solder wetting layer (Cu-Zn 합금 젖음층을 이용한 Sn-Ag-Cu 솔더 접합부의 낙하 충격 신뢰성 향상 연구)

  • Kim, Yeong-Min;Kim, Yeong-Ho
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.35.2-35.2
    • /
    • 2009
  • 최근 본 연구실에서 무연 솔더를 위한 새로운 Cu-Zn 합금 젖음층을 개발하였다. 전해도금을 통하여 Cu-Zn 합금층을 형성한 뒤 그 위에 Sn-4.0wt% Ag-0.5wt% Cu (SAC 405) 솔더를 리플로 솔더링을 통해 솔더접합부를 형성하였으며 계면에서 생성된 금속간 화합물의 형성 및 성장 거동을 연구하였다. SAC/Cu 시스템의 경우, $150^{\circ}C$에서 시효 처리를 실시하는 동안 솔더와 도금된 Cu 계면에서 $Cu_6Sn_5$ 상과 미세한 공공이 형성된 $Cu_3Sn$ 상이 발견되었다. 반면에 SAC/Cu-Zn 시스템에서는 계면에서 $Cu_6Sn_5$ 상만이 형성되었다. 또한 큰 판상형의 $Ag_3Sn$ 상이 SAC/Cu 시스템에 비해 현저하게 억제되었다. SAC/Cu-Zn 계면에서의 금속간 화합물의 성장 속도가 SAC/Cu 계면에서 형성된 금속간 화합물의 성장 속도보다 느리게 나타났다. Cu-Zn 젖음층의 Zn가 솔더와 Cu-Zn 층 사이에서 Cu와 Sn 원자의 상호 확산을 방해하기 때문이다. 본 연구에서는 Cu와 Cu-Zn 층을 이용한 솔더 접합부의 낙하 충격 신뢰성을 연구하였다. 낙하 충격 시험 시편은 두 개의 인쇄 회로 기판을 SAC 405 솔더볼을 이용하여 리플로를 통해 상호연결 하여 제조되었다. 이 때, 각각의 인쇄 회로 기판의 패드에는 Cu 층과 Cu-Zn층을 전해도금을 통하여 각각 $10{\mu}m$두께의 젖음층을 형성하였다. 낙하 시험 시편을 제조한 뒤, 시효 처리에 대한 낙하 저항 신뢰성의 특성을 연구하기 위해 250, 500 시간동안 시효처리를 한 후 각 조건에서 계면에 형성된 금속간 화합물의 성장 거동을 관찰하였으며, 낙하 충격 시험을 실시하였다. 낙하 시험은 daisy chain으로 연결된 시편의 저항이 100 Ohm 이상 측정되었을 때 중단되도록 하였다. Cu-Zn/SAC/Cu-Zn 시편의 경우 초기 리플로를 하였을 때 불량이 발생하는 평균 낙하 수는 350이며, Cu/SAC/Cu 시편의 평균 낙하수는 200 미만으로 나타났다. Cu/SAC/Cu 시편의 경우, 시효처리 시간이 증가함에 따라 평균 낙하수는 큰 폭으로 감소하였지만, Cu-Zn/SAC/Cu-Zn 시편은 불량이 발생하는 평균 낙하수의 감소폭이 보다 완만하게 나타났다. Cu 층에 Zn를 첨가함으로써 솔더와 젖음층 사이에서 형성된 금속간 화합물의 성장 및 미세 공공의 형성이 억제되었고, 솔더 접합부의 과냉을 감소시킴으로써 큰 판상형의 $Ag_3Sn$ 상의 형성을 억제함으로써 Cu-Zn/SAC/Cu-Zn 솔더 접합부에서 Cu/SAC/Cu 솔더 접합부보다 낙하 충격에 대한 저항성 및 신뢰성이 향상되었다. 이는 무연 솔더에 Zn를 첨가하여 낙하 충격 신뢰성을 향상시킨 것과 동일한 효과를 나타냈음을 확인하였다. 본 연구는 한국 과학 기술 재단의 전자패키지 재료 연구 센터(CEPM)와 지식 경제부의 부품 소재 기술 개발 사업의 지원을 받아 수행되었습니다.

  • PDF