• Title/Summary/Keyword: 금속인공물

Search Result 77, Processing Time 0.019 seconds

Comparison of Metal Artifact Reduction Algorithms in Patients with Hip Prostheses: Virtual Monoenergetic Images vs. Orthopedic Metal Artifact Reduction (고관절 인공치환술 환자에서 금속 인공물 감소 방법의 비교: 가상 단일에너지영상 대 금속 인공물 감소기법)

  • Hye Jin Yoo;Sung Hwan Hong;Ja-Young Choi;Hee Dong Chae
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1286-1297
    • /
    • 2022
  • Purpose To assess the usefulness of various metal artifact reduction (MAR) methods in patients with hip prostheses. Materials and Methods This retrospective study included 47 consecutive patients who underwent hip arthroplasty and dual-energy CT. Conventional polyenergetic image (CI), orthopedic-MAR (OMAR), and virtual monoenergetic image (VMI, 50-200 keV) were tested for MAR. Quantitative analysis was performed in seven regions around the prostheses. Qualitative assessments included evaluation of the degree of artifacts and the presence of secondary artifacts. Results The lowest amount of image noise was observed in the O-MAR, followed by the VMI. O-MAR also showed the lowest artifact index, followed by high-keV VMI in the range of 120-200 keV (soft tissue) or 200 keV (bone). O-MAR had the highest contrast-to-noise ratio (CNR) in regions with severe hypodense artifacts, while VMI had the highest CNR in other regions, including the periprosthetic bone. On assessment of the CI of pelvic soft tissues, VMI showed a higher structural similarity than O-MAR. Upon qualitative analysis, metal artifacts were significantly reduced in O-MAR, followed by that in VMI, while secondary artifacts were the most frequently found in the O-MAR (p < 0.001). Conclusion O-MAR is the best technique for severe MAR, but it can generate secondary artifacts. VMI at high keV can be advantageous for evaluating periprosthetic bone.

Clinical Apply of Dual Energy CT (kVp switching) : A Novel Approach for MAR(Metal Artifact Reduction) Method (듀얼에너지 CT(kvp switching)의 임상 적용: MAR(Metal Artifact Reduction) 알고리즘의 적용)

  • Kim, Myeong-Seong;Jeong, Jong-Seong;Kim, Myeong-Goo
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.2
    • /
    • pp.79-85
    • /
    • 2011
  • OThe purpose of this article was to measure and compare the value of the metal artifact reduction (MAR) algorithm by Dual energy(kVp switching) CT (Computed Tomography) for non using MAR and we introduced new variable Dual energy CT applications through a clinical scan. The used equipment was GE Discovery 750HD with Dual-Energy system(kVp switching). CT scan was performed on the neck and abdomen area subject for patients. Studies were from Dec 20 2010 to Feb 10 2011 and included 25 subject patients with prosthesis. We were measured the HU (Hounsfield Unit) and noise value at metal artifact appear(focal loss of signal and white streak artifact area) according to the using MAR algorithm. Statistical analyses were performed using the paired sample t-test. In patient subject case, the statistical difference of showing HU was p=0.01 and p=0.04 respectively. At maximum black hole artifact area and white streak artifact area according to the using MAR algorithm. However noise was p=0.05 and p=0.04 respectively; and not the affected black hole and white streak artifact area. Dual Energy CT with the MAR algorithm technique is useful reduce metal artifacts and could improve the diagnostic value in the diagnostic image evaluation of metallic implants area.

A Study of the CT MAR using Single-Source and Dual-Source Devices: Practical Comparison using Animal Phantom Fabrication (단일 선원 장치와 이중 선원 장치 비교를 이용한 전산화단층촬영 금속인공물 감소에 대한 연구: 동물팬텀 제작을 이용한 실측적인 비교)

  • Goo, EunHoe
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.1003-1011
    • /
    • 2020
  • This study aims to compare and evaluate the image differences between single and dual sources in applying a technique to reduce metal artifacts using dual energy CT. Discovery CT 256 (GE, USA) as a single source device and Somatom Definition Flash (Siemens Health Care, Forchheim, Germany) as a dual source device. The self-made phantom (pigs with medical titanium screws inserted) was quantitative and qualitatively evaluated under the same conditions by varying the dose under the same conditions using a dual energy CT. The evaluation method was compared by measuring SNR for metal artifacts (scattering, stripe) generated by metal inserts, divided around bones and around tissues. There was a difference in images in the method of reducing metal artifacts between single-source and dual-source devices. In a single source device, the linearized prosthesis by metal implantation showed a greater decrease than the image obtained from a double source device, and the surrounding tissue was well observed without interference from the artifact. In dual-source devices, scattering and stripe artifacts caused by metal inserts decreased more than on a single source device, and signals from adjacent tissues surrounding the metal implant were well observed without diminishing. If the examination is conducted separately between single source and dual source devices depending on whether the area to which the patient is intended to be viewed during the examination is adjacent to the metal insert or the total tissue surrounding the metal insert, it is believed that diagnostic helpful images can be obtained.

Consideration on Methods to Suppress Metal Artifacts Caused by Spinal Fusion during Spine MRI Study (척추 MRI 검사 시 척추 유합술로 인한 금속 인공물 억제 방법에 대한 고찰)

  • Se-Jong Yoo;Soon-Yong Kwon;Seong-Ho Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1123-1131
    • /
    • 2023
  • This study aimed to present a method to effectively suppress metal artifacts caused by spinal fusion surgery during spinal MRI study. For this purpose, a phantom made of spinal surgery screws was created to reproduce the metal artifact. Then, images were acquired with 1.5T and 3.0T MRI to evaluate changes in metal artifacts according to magnetic field strength. In addition, metal artifacts were evaluated by increasing the receive bandwidth to 200, 400 and 800 Hz/PX. As a result, metal artifacts occurring in images obtained from the 1.5T MRI decreased by approximately 52.2% compared to images obtained from the 3.0T MRI, showing a significant difference (p<0.05). In particular, the signal loss and signal pile up areas were reduced by approximately 52.81% and 42.71%, respectively, showing a significant effect in suppressing metal artifacts. On the other hand, when images were acquired while increasing the receive bandwidth from 200 to 800 Hz/PX, there was no significant effect, with a decrease of up to 8.93% for the 1.5T MRI and up to 10.98% for the 3.0T MRI (p>0.05). As a result of this study, increasing the receive bandwidth reduced signal loss and reduced some metal artifacts, but did not have a significant effect because it did not suppress signal pile up. However, when the magnetic field strength was reduced from 3.0T to 1.5T, signal loss and signal pile up were greatly reduced, effectively improving the metal artifact. Therefore, in order to suppress metal artifacts caused by spinal fusion surgery, study using a low magnetic field MRI can be said to be the most effective method.

Reduction of Artifacts in Magnetic Resonance Imaging with Diamagnetic Substance (반자성 물질을 이용한 자기공명영상검사에서의 인공물 감소)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.581-588
    • /
    • 2019
  • MRI is superior when contrasted to help the organization generate artifacts resolution, but also affect the diagnosis and create a image that can not be read. Metal is inserted into the tooth, it is necessary to often be inhibited in imaging by causing the geometric distortion due to the majority and if the difference between the magnetic susceptibility of a ferromagnetic material or paramagnetic reducing them. The purpose of this study is to conduct a metal artefact in accordance with the analysis using a diamagnetic material. The magnetic material include a wire for the orthodontic bracket and a stainless steel was used as a diamagnetic material was used copper, zinc, bismuth. Testing equipment is sequenced using 1.5T, 3T was used was measured using a SE, TSE, GE, EPI. A self-produced phantom material was used for agarose gel (10%) to a uniform signal artifacts causing materials are stainless steel were tested by placing in the center of the phantom and cover inspection of the positive cube diamagnetic material of 10mm each length.After a measurement artefact artifact zone settings area was calculated using the Wand tool After setting the Low Threshold value of 10 in the image obtained by subtracting images, including magnetic material from a pure tool phantom images using Image J. Metal artifacts occur in stainless steel metal artifact reduction was greatest in the image with the bismuth diamagnetic materials of copper and zinc is slightly reduced, but the difference in degree will not greater. The reason for this is thought to be due to hayeotgi offset most of the susceptibility in bismuth diamagnetic susceptibility of most small ferromagnetic. Most came with less artifacts in image of bismuth in both 1.5T and 3T. Sequence-specific artifact reduction was most reduced artifacts from the TSE 1.5T 3T was reduced in the most artifacts from SE. Signal-to-noise ratio was the lowest SNR is low, appears in the implant, the 1.5T was the Implant + Bi Cu and Zn showed similar results to each other. Therefore, the results of artifacts variation of diamagnetic material, magnetic susceptibility (${\chi}$) is the most this shows the reduced aspect lower than the implant artificial metal artifacts criteria in the video using low bismuth susceptibility to low material the more metal artifacts It was found that the decrease. Therefore, based on the study on the increase, the metal artifacts reduction for the whole, as well as dental prosthesis future orthodontic materials in a way that can even reduce the artifact does not appear which has been pointed out as a disadvantage of the solutions of conventional metal artifact It is considered to be material.

Standards for Applying Reasonable Receive Bandwidth to Suppress Metal Artifacts in MRI (MRI 검사 시 금속 인공물 억제를 위한 합리적인 수신대역폭 적용 기준)

  • Se-Jong Yoo;Min-Cheol Jeon;Nam-Yong An;Soon-Yong Kwon;Seong-Ho Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1115-1122
    • /
    • 2023
  • This study aimed to present reasonable reception bandwidth application standards for the purpose of suppressing metal objects during MRI examinations. For this purpose, T2 contrast images were acquired using high-speed spin echo technology on a phantom made of screws for spinal surgery, and metal objects were detected. In addition, images were obtained by increasing the reception bandwidth from 100 Hz/PX to 800 Hz/PX by 100 Hz/PX. The metal artifacts were determined as the sum of the areas of the signal attenuation area and the signal accumulation area. In addition, Pearson correlation analysis was performed to analyze the pattern of metal artifacts according to imaging variables. As a result, the signal accumulation area did not change significantly as the reception bandwidth increased (p>0.05), but the signal loss area and the area of metal artifacts decreased as the reception bandwidth increased (p<0.05). Interestingly, the area of metal objects decreased to a maximum in the section where the reception bandwidth was increased from 100 Hz/PX to 200 Hz/PX, consistent with the section where the echo spacing was reduced to a maximum due to the increase in reception bandwidth. In addition, the correlation analysis results also showed that the eco spacing was more related to the signal attenuation area and the area of metal objects than to the reception bandwidth. Therefore, if the reception bandwidth is increased for the purpose of reducing metal objects, it is reasonable to set it based on a value that minimizes the echo spacing in consideration of image quality factors.

Convergence Comparison of Metal Artifact Reduction Rate for Pacemaker Insertion of CT Imaging Phantoms in the Raw Data with MAR Algorithm (심박조율기 삽입 팬텀의 CT영상 원시데이터에 금속인공물감소 알고리즘 적용 시 금속인공물 감소율의 융합적 비교)

  • Kim, Hyeon-ju;Yoon, Joon
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.1
    • /
    • pp.43-49
    • /
    • 2017
  • In the analyzed cardiac CT algorithm applied when comparing the MAR self-made metal artifact reduction in pacemaker inserted phantom degree. Result of comparing the energy value by CT showed a decrease in the CT value in the case of BKG 40 KeV in WSA maximum decreased to 663.2% in the case of 140 KeV BHA were increased a maximum of 56.2%. In addition, the maximum was decreased by approximately 145% based on a 70 KeV artifacts in CT value comparison by type WSA, BHA was to increase up to approximately 46.38%. MAR Algorithm is believed to provide a more quality cardiac CT image if the energy changes, or have the effect that by type and irrespective of reduced metal artifacts occurrence of artifacts applied to the pacemaker when tracking a heart CT scan after inserting MAR algorithm.

Distortion of Magnetic Resonance Imaging for Different Types of Orthodontic Material (치과 교정 물질에 따른 자기공명영상의 왜곡)

  • Song, Hyun-Og;Lim, Cheong-Hwan;Lee, Sang-Ho;Yang, Oh-Nam;Baek, Chang-Moo;Jung, Hong-Ryang
    • Journal of Digital Convergence
    • /
    • v.12 no.2
    • /
    • pp.439-446
    • /
    • 2014
  • To evaluate the effects of an artifact by metal material for orthodontics in Magnetic Resonance Image (MRI) examination, wires and brackets used in orthodontics were selected and compared. Using a head coil, a $T_2$-weighted image, $T_1$-weighted image and FLAIR image were obtained. With obtained images, the sizes of the artifacts were measured and compared using Image J Program. In the research, the material with the biggest artifact in the wires and brackets for orthodontics was stainless steel wire. In the future, selecting and developing metal for correction should be considered also in other fields along with the purpose of orthodontics.

Usefulness Evaluation of Application of Metallic Algorithm Reducing for Beam Hardening Artifact Occur in Typical Brain CT Image (머리 CT영상에서 흔히 발생하는 선속경화인공물 감소를 위한 금속인공물감소 알고리즘 적용의 유용성 평가)

  • Kim, Hyeon ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.389-395
    • /
    • 2018
  • The study attempted to use computed tomography images to determine the usefulness of the reduction in the axial reduction algorithm in the event of a metallic artifacts reduction in the image of the beam-hardening effect, which is known as the most effective method of reducing metallic artifact reduction in the image and the reduction of the metal produced in this study. As a result, the result is increased to 140 kVp to reduce the value of the CT value by 0.02 to 0.05 %, resulting in decreased axial effect (P > 0.05). The CT value decreased from 12.4 to 26.9 % when applied to the reduction of the metallic. 12.4 to 26.9 % (p<0.05). In addition, in the qualitative assessment by the clinical trial evaluation, it was assessed as 1.8 points after applying the MAR algorithm, In the resolution of resolution and contrast evaluations, the estimation of the decrease in metallic artifact effects was assessed as the metal was assessed to be scored 7.2 points after the MAR algorithm was evaluated. Therefore, in case of artifacts due to irreversible beam hardening effect, it is useful to reduce artifacts caused by beam hardening effect by using various methods derived from existing researches and scanning by applying the metal artifact reduction algorithm proposed in this experiment.

Evaluation of Effect of Decrease in Metallic Artifacts using the Synthetic MR Technique (Synthetic MR 기법을 이용한 금속 인공물 감소 효과 평가)

  • Soon-Yong, Kwon;Nam-Yong, Ahn;Jeong-Eun, Oh;Seong-Ho, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.835-842
    • /
    • 2022
  • This study is aimed to evaluate the effects of a synthetic MR technique in reducing metal artifacts. In the experiment, the in-plane and through-plane images were acquired by applying a synthetic MR technique and a high-speed spin echo technique to a phantom manufactured with screw for spinal surgery. The area of the metal artifact was compared. The metal artifacts were measured by dividing the signal-loss and the signal pile-up areas, and the area of the final artifact was calculated through the sum of the two. As a result, the metal artifacts were relatively reduced when the synthetic MR techniques were applied to both in-plane and through-plane. Comparing by sequence, the in-plane T1 images decreased by 23.45%, T2 images by 20.85%, PD images by 19.67%, and FLAIR images by 22.12%. Also, in the case of the through-plane, the T1 image decreased by 62.95%, the T2 image decreased by 73.93%, the PD image decreased by 74.68%, and the FLAIR image decreased by 66.43%. The cause of this result is that when the synthetic MR technique is applied, the distortion is due to the signal pile-up and does not occur and the size of the entire metal artifact is reduced. Therefore, synthetic MR technique can very effectively reduce metal artifacts, which can help to increase the diagnostic value of images.