A Study on Characteristics of Residue in Liquefied Petroleum Gas using Automotive Fuel (자동차용 액화석유가스(LPG) 잔류물질의 특성 연구)

  • Jang, Yoon-mi;Park, Tae-seong;Kang, Hyung-kyu;Yim, Eui Soon;Lee, Jung-min;Na, Byung-gi
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.816-825
    • /
    • 2018
  • Recently, it was emerged to need the necessity of LPG residues management due to the finding some substances such as rust. This study is performed to investigate the characteristics of LPG residues in the production and distribution stage of LPG. For the qualitative analysis of LPG residues, it was operated to be set up the analysis conditions(the flow rate, etc) of GC-MS and was performed to analyze the component of LPG residues. From the analysis result using GC-MS, it was shown that the component of LPG residues was turned out the plasticizer to be used in the rubber manufacturing process. The inorganic components of LPG residues were analyzed using ICP-OES. At the results of inorganic analysis, it was shown that the Si element was detected, which was presumably derived from defoamers used mainly in the LPG production. Also, the P and Zn element, which are estimated to be components of grease additives used for filling facilities, were also partially detected. No trace of rusting was detected in the LPG residues in the production and distribution stages analyzed in this study. But, as plasticizers and grease additives can affect to the LPG fuel system in vehicles, it will be necessary to use the proper quality of rubber and to expand the use of low boiling grease additives.

Fractional efficiency of Nanomaterials for the High efficiency respiratory filters (고효율 호흡보호구의 나노물질 입경별 제거 효율)

  • Lee, Gwang-Jae;Ji, Jun-Ho;Kim, Won-Geun;Yook, Se-Jin;Kim, Jong-Kyo;Kim, Jung-Ho
    • Particle and aerosol research
    • /
    • v.12 no.3
    • /
    • pp.95-102
    • /
    • 2016
  • Controlling exposures to occupational hazards is important for protecting workers. Certified facepiece respirators are recommended when engineering controls do not adequately prevent exposures to airborne nanomaterials. The objective of this study is to carry out the experimental performance test to investigate the fractional efficiencies of the filter media for two grades of facepiece respirators. Experimental performance evaluations were carried out for the test NaCl particles and silver nanoparticles. For media of respirator filter, the penetration of NaCl particles was less than 5% and the most penetrating particle size occurred at about 40 nm. For silver nanoparticles, the most penetrating particle size was about 20nm with higher efficiency than those of NaCl particles. Charge characteristics of airborne nanoparticles is important because the media of respirator filter is made by the electret filter media.

Analysis of Frequency Response Curve for Conduction-Cooled Power Capacitors (전도 냉각 파워 커패시터의 주파수 응답 곡선 분석)

  • An, Gyeong Moon;Kim, Hiesik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.10
    • /
    • pp.123-130
    • /
    • 2016
  • High-frequency induction heating equipment can heat the metal by applying a High-Frequency power to the resonant circuit. The resonance circuit is composed of the work coil and the conduction-cooled power capacitor, it influences the performance of the heat treatment equipment according to the characteristics of the capacitor. However, dependence on conduction-cooled power capacitor's import is high due to lack of core technology research and development. Minimizing the generation of internal heat transmitted inside during LC resonance, reduce the reactive power loss, there is a need for a capacitor within the voltage characteristic outstanding. To implement localization it is vital that prior study of the analysis on the frequency response characteristic for the finished capacitor advanced manufacturer be implemented. Studying the interpolation method to read the value at any point of the characteristic curve for a given log-log scale was applied to the analysis tool of the capacitor by my proposed algorithm. The simulation for reproducing frequency response curves was attempted by assuming a capacitor in a simplified series equivalent RC circuit to obtain the equivalent series resistance value. It was confirmed that the reproduction rate was the result value above 83% as compared to the simulation of the properties and characteristics on the actual reactive power for Peak value, and that the algorithm can be applicable when analyzing and predicting the characteristic curves of a simpled model capacitor.

하이브리드 SEM 시스템

  • Kim, Yong-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.109-110
    • /
    • 2014
  • 주사전자현미경(Scanning Electron Microscopy: SEM)은 고체상태에서 미세조직과 형상을 관찰하는 데에 가장 다양하게 쓰이는 분석기기로서 최근에 판매되고 있는 고분해능 SEM은 수 나노미터의 분해능을 가지고 있다. 그리고 SEM의 초점심도가 크기 때문에 3차원적인 영상의 관찰이 용이해서 곡면 혹은 울퉁불퉁한 표면의 영상을 육안으로 관찰하는 것처럼 보여준다. 활용도도 매우 다양해서 금속파면, 광물과 화석, 반도체 소자와 회로망의 품질검사, 고분자 및 유기물, 생체시료 nnnnnnnnn와 유가공 제품 등 모든 산업영역에 걸쳐 있다(Fig. 1). 입사된 전자빔이 시료의 원자와 탄성, 비탄성 충돌을 할 때 2차 전자(secondary electron)외에 후방산란전자(back scattered electron), X선, 음극형광 등이 발생하게 되는 이것을 통하여 topography (시료의 표면 형상), morphology(시료의 구성입자의 형상), composition(시료의 구성원소), crystallography (시료의 원자배열상태)등의 정보를 얻을 수 있다. SEM은 2차 전자를 이용하여 시료의 표면형상을 측정하고 그 외에는 SEM을 플랫폼으로 하여 EDS (Energy Dispersive X-ray Spectroscopy), WDS (Wave Dispersive X-ray Spectroscope), EPMA (Electron Probe X-ray Micro Analyzer), FIB (Focus Ion Beam), EBIC (Electron Beam Induced Current), EBSD (Electron Backscatter Diffraction), PBMS (Particle Beam Mass Spectrometer) 등의 많은 분석장치들이 SEM에 부가적으로 장착되어 다양한 시료의 측정이 이루어진다. 이 중 결정구조, 조성분석을 쉽고 효과적으로 할 수 있게 하는 X선 분석장치인 EDS를 SEM에 일체화시킨 장비와 EDS 및 PBMS를 SEM에 장착하여 반도체 공정 중 발생하는 나노입자의 형상, 성분, 크기분포를 측정하는 PCDS(Particle Characteristic Diagnosis System)에 대해 소개하고자 한다. - EDS와 통합된 SEM 시스템 기본적으로 SEM과 EDS는 상호보완적인 기능을 통하여 매우 밀접하게 사용되고 있으나 제조사와 기술적 근간의 차이로 인해 전혀 다른 방식으로 운영되고 있다. 일반적으로 SEM과 EDS는 별개의 시스템으로 스캔회로와 이미지 프로세싱 회로가 개별적으로 구현되어 있지만 로렌츠힘에 의해 발생하는 전자빔의 왜곡을 보정을 위해 EDS 시스템은 SEM 시스템과 연동되어 운영될 수 밖에 없다. 따라서, 각각의 시스템에서는 필요하지만 전체 시스템에서 보면 중복된 기능을 가지는 전자회로들이 존재하게 되고 이로 인해 SEM과 EDS에서 보는 시료의 이미지의 차이로 인한 측정오차가 발생한다(Fig. 2). EDS와 통합된 SEM 시스템은 중복된 기능인 스캔을 담당하는 scanning generation circuit과 이미지 프로세싱을 담당하는 FPGA circuit 및 응용프로그램을 SEM의 회로와 프로그램을 사용하게 함으로 SEM과 EDS가 보는 시료의 이미지가 정확히 일치함으로 이미지 캘리브레이션이 필요없고 측정오차가 제거된 EDS 측정이 가능하다. - PCDS 공정 중 발생하는 입자는 반도체 생산 수율에 가장 큰 영향을 끼치는 원인으로 파악되고 있으며, 생산수율을 저하시키는 원인 중 70% 가량이 이와 관련된 것으로 알려져 있다. 현재 반도체 공정 중이나 반도체 공정 장비에서 발생하는 입자는 제어가 되고 있지 않은 실정이며 대부분의 반도체 공정은 저압환경에서 이루어지기에 이 때 발생하는 입자를 제어하기 위해서는 저압환경에서 측정할 수 있는 측정시스템이 필요하다. 최근 국내에서는 CVD (Chemical Vapor Deposition) 시스템 내 파이프내벽에서의 오염입자 침착은 심각한 문제점으로 인식되고 있다(Fig. 3). PCDS (Particle Characteristic Diagnosis System)는 오염입자의 형상을 측정할 수 있는 SEM, 오염입자의 성분을 측정할 수 있는 EDS, 저압환경에서 기체에 포함된 입자를 빔 형태로 집속, 가속, 포화상태에 이르게 대전시켜 오염입자의 크기분포를 측정할 수 있는 PBMS가 일체화 되어 반도체 공정 중 발생하는 나노입자 대해 실시간으로 대처와 조치가 가능하게 한다.

  • PDF

Evaluation of Residual Radioactivity and Dose Rate of a Target Assembly in an IBA Cyclotron (IBA 사이클로트론 표적집합체에서의 잔류 방사화 분석 및 선량률 평가)

  • Hwang, Seon Yong;Kim, Youngju;Lee, Seung Wook
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.643-649
    • /
    • 2016
  • When a cyclotron produces $^{18}F^-$, accelerated protons interact with metal parts of the cyclotron machine and induces radioactivity. Especially, the target window and chamber of the target assembly are the main parts where long-lived radionuclides are generated as they are incident by direct beams. It is of great importance to identify radionuclides induced in the target assembly for the safe operation and maintenance of a cyclotron facility. In this study, we analyzed major radionuclides generated in the target assembly by an operation of the Cyclotron 18/9 machine and measured dose rates after the operation to establish the radiation safety guideline for operators and maintenance personnel of the machine. Gamma spectroscopy with HPGe was performed on samples from the target chamber and Havar foil target window to identify the radionuclides generated during the operation for production of $^{18}F^-$- isotope and their specific activity. Also, the dose rates from the target were measured as a function of time after an operation. These data will help improve radiological safety of operating the cyclotron facilities.

Study of Characteristics for Red Adhesive in Traditional Gold Thread (전통 편금사에 사용된 붉은 접착제 특성 연구)

  • Kim, Ji Eun;Yu, Ji A;Han, Ye Bin;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • v.32 no.1
    • /
    • pp.43-49
    • /
    • 2016
  • Gold threads mean thread made by metal, it is composed various material to gold leaf, adhesive and media. The making technique and using materials of Gold threads are different from region, it can be used to distinguish country of origin. So this study finds characteristics and making techniques for flat gold threads of relics. Standard samples are made of animal glue, lacquer, red lacquer and etc. This materials are based on the scientific investigation of cultural gold threads properties. Then traditional techniques were estimated by comparison and analysis of actual cultural properties and standard samples. As a result of investigating cultural properties, it is similar to the standard sample which are mixed with red soil additives. After analysis of SEM-EDS, it is detected to Al, Si, Fe. So it is to the conclusion that traditional gold thread is made of adhesive mixed with red soil to improve gold color better. And this ways are similar with china that uses animal glue and red soil to adhesive and different from japan that uses lacquer to adhesive. Through this study, it will be used to data and reference for reappearance and making techniques of traditional gold threads.

Effects of Metalized Al-2%Zn Layer on the Corrosion Behavior of Al 5083 Alloy (Al 5083 합금의 부식거동에 미치는 Al-2%Zn 용사 코팅층의 영향)

  • 김용철;김영근;이성민;고영태
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.05a
    • /
    • pp.2-2
    • /
    • 1999
  • 금속재료의 표면 특성을 높이기 위해서 여러 표면처리 방법들이 사용되어져 오고 있다. 그 중 용사법에 의한 코팅방법이 최근의 현저한 기술적인 진보와 새로운 용사재료의 개발 등에 의해 여러 분야에 널리 응흉되고 있다. 일반적으로 이 용사법에 의한 코팅층은 다리, 선박 등의 대형 구조물에 대한 내식성 향상뿐만 아니라 자동차 및 항공기 부품, 핵 반응기 등의 코팅부에 널리 이용되고 였다. 특히 해수분위기에서 주로 사용되는 설비의 내식성을 향상시킬 목적으로 사용되 는 알루마늄 및 아연 합금의 용사 코팅층은 대부분의 경우 건조한 분위기보다는 수분이 많은 수용액 환경 하에서 사용되므로, 사용 환경 중에서 용사피막의 내식성을 조사하는 연구가 요구되고 있다. 사용되는 환경하에서의 침지시험에 의한 방법도 중요하지만, 가속화된 전기화학측정에 의한 방법 또한 이용된다. 열용사법에 의한 코팅층의 전기화학적 특성을 알아보기 위해서 3.5 % NaCI 수용액 내에서 AI 5 5083 모재와 Al-2%Zn 합금의 용사 코팅층 각각에 대한, 그리고 AI 5083 모재 위 AI-2%Zn 용사층이 코팅된 경우에 대한 분극거동과 침지시간에 따른 부식전위 및 분극저항성의 특성변화, 표면의 임피던스특성 변화 등을 측정하였다. 이 결과 모재에 대한 코팅층의 희생양극성올 판단할 수 있고, 모재/코팅 사스템의 분극거동은 혼성전위이론(mixed-potential theory)에 의해 결정되었다. 용사 코팅층이 박리되어 모재가 일부 드러난 경우를 모사한 시험편올 제작하고, 시험편 표면의 각 위치에 따라 부식전위 분포를 측정하였다. 그리고 측정 데이터를 기초로 표면의 상태변화를 모사하여 용사코팅에 의한 표면에서의 방식전위분포를 시율레이션하였다. 이와 같은 표면에서의 방식전위분포 해석을 통하여, 코팅층의 희생양극성에 의한 모재의 방식범위를 판단할 수 있다.의 비저 항을 갖는 철 박막에서도 99.9% 순도의 철을 타켓으로 하여 증착된 막은 일반 저탄소 강을 타켓으로 하여 증착된 막보다 훨씬 낮은 부식속도를 보였다.TEX>$He/O_2/Ar/N_2$의 gas를 사용 한 atmospheric pressure plasma cleaning 과 $Ar/O_2$의 gas를 사용한 ICP cleaning에서 이 차전자방출계수(SEEC)가 약 1.5~2.5배 증가된 것을 알 수 있었다. 저지능 등을 평가하여 각 실험결과를 비교분석하여 보았다. 수록 민감하여 304 의 IGSCC 와 매우 유사한 거동을 보인다. 본 강연에서는 304 와 600 의 고온 물에서 일어나는 IGSCC 민감도에 미치는 환경, 예민화처리, 합금원소의 영향을 고찰하고 이에 대한 최근의 연구 동향과 방식 방법을 다룬다.다.의 목적과 지식)보다 미학적 경험에 주는 영향이 큰 것으로 나타났으며, 모든 사람들에게 비슷한 미학적 경험을 발생시키는 것 이 밝혀졌다. 다시 말하면 모든 사람들은 그들의 문화적인 국적과 사회적 인 직업의 차이, 목적의 차이, 또한 환경의 의미의 차이에 상관없이 아름다 운 경관(High-beauty landscape)을 주거지나 나들이 장소로서 선호했으며, 아름답다고 평가했다. 반면에, 사람들이 갖고 있는 문화의 차이, 직업의 차 이, 목적의 차이, 그리고 환경의 의미의 차이에 따라 경관의 미학적 평가가 달라진 것으로 나타났다.corner$적 의도에 의한 경관구성의 일면을 확인할수 있지만 엄밀히 생각하여 보면 이러한 예의 경우도 최락의 총체적인 외형은 마찬가지로 $\ulcorner$순응$\lrcorner$의 범위를 벗어나지 않는다. 그렇기 때문에도 $\ulcorner$순응$\lrcorne

  • PDF

Study on Temperature Dependence of Molecular Structure in Stearic Acid LB Films Using FTIR-RAS (FTIR-RA 분광법을 이용한 스테아르산 단분자막에서 분자구조의 온도의존성 고찰)

  • Kim, Dong Won;Park, Sang Rae;Umemura Junjo;Takeda Satoshi;Hasegawa Takeshi;Takenaka Tohru;Lee Hai Won
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.6
    • /
    • pp.570-576
    • /
    • 1993
  • 1-, 3-, 9-, and 21-Monolayer Langmuir-Blodgett(LB) films of stearic acid were deposited on silver-coated glass slides at the surface pressure of 30 mN/m. Fourier transform infrared(FTIR) reflection-absorption spectra (RAS) of these LB films were recorded at various temperatures from 31 to $72^{\circ}C.$ The spectra at $31^{\circ}C$ exhibited characteristic features of highly perpendicular orientation of the hydrocarbon chain. In the 1-monolayer LB film, the C=O stretching band was not observed, presumably due to the image dipole effect on the silver surface. In the 1-and 3-monolayer LB films, the trans isomer of stearic acid was prominent, but the cis isomer was dominant in the 21-monolayer LB film. FTIR-RAS measurements at an elevated temperature indicated that the chain melting temperature increases and approached to the bulk melting point with increasing the number of monolayer, except for the 1-monolayer LB film which has a higher melting temperature than the 3-monolayer film due to the strong interaction with the silver substrate.

  • PDF

Accuracy comparison of buccal bite scans by five intra-oral scanners (구강스캐너 5종의 협측 악간관계 스캔 정확성 비교 연구)

  • Park, Ji-Man;Jeon, Jin;Heo, Seong-Joo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.17-31
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the accuracy of the interocclusal relationship between upper and lower teeth according to the buccal interocclusal record scan using various intraoral scanner systems. Materials and Methods: The upper and lower full arch Models with normal occlusion were scanned with 5 intraoral scanners (Cerec Omnicam, CS3500, iTero, Trios, True Definition). Buccal interocclusal record scan was taken only at the left side while occlusion was intentionally raised by 1 mm, 2 mm, 3 mm, and 4 mm with metal cylinder core embedded within polyvinylsiloxane bite registration material at the right molar region. The superimposition analysis was done to evaluate overall three-dimensional deviation and cross-section analysis was done to evaluate the degree and the direction of deviation of interocclusal relationship. Results: From the superimposition study, Cerec Omnicam showed the least deviation ($165.5{\mu}m$) and CS3500 ($369.0{\mu}m$) showed the largest (P < 0.01). And the deviation was greater in 3, 4, 2 mm group than 1 mm (P < 0.01). From the cross-section study, Cerec Omnicam showed the farthest deviation ($-242.8{\mu}m$) and CS3500 showed the closest deviation ($312.5{\mu}m$) and a significantly high value was shown in 3 mm group. Conclusion: Every intraoral scanner has different accuracy in reproducing interocclusal relationship.

Development of Advanced Manufacturing Process of Light Interference Pearl Pigment (광 간섭 펄 안료의 신규 제조 공정 개발)

  • Son, Hong Ha;Yu, Jae Won;Kim, Kyung Seob
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.41 no.2
    • /
    • pp.121-126
    • /
    • 2015
  • In general, the pearlescent pigment is a pigment which was used for optical characteristics like pearl, rainbow and metallic luster. Titanium dioxide coated mica plate developed by DuPont in 1965 is currently being used as a main part of pearlescent pigment for cosmetics. Although the smooth and clear surface substrate laminated with 2 ~ 3 ingredients is thicker than a previous monolayer coated substrate, it has been applied for cosmetics as the optical interference powder to realize stronger shine and brighter interference color than monolayer one. In this study, we developed a new optical interference powder with thinner and higher chroma than a current pearlescent pigment for the strong luster and bright interference color. It was prepared from the manufacturing process, in which the coated titanium dioxide precursor was changed and crystallized by coating and heat treatment process with a half of dividing the coated amount of titanium dioxide. We confirmed the dense coating of titanium dioxide grain with Scanning Electron Microscope and measured superior crystallization degree compared with a monolayer coated pearlescent pigment by X-ray Diffraction. It is concluded that our new pearlescent pigment had higher reflectivity of light and stronger interference color than previous products.