• Title/Summary/Keyword: 글레어 광원

Search Result 11, Processing Time 0.021 seconds

An Experiment of Discomfort Glare from Non-uniform Glare Source (불균일한 휘도를 갖는 창면의 불쾌글레어 평가실험)

  • Shin, Ju-Young;Kim, Jeong-Tai;Kim, Won-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.1-9
    • /
    • 2009
  • Impact of daylighting on the visual environment can improve occupant's well-being by providing visual comfort. Also, daylighting can save energy. However, glare from window can be a direct hazard to vision and can cause serious discomfort. Selecting glare source on a window plane is very important for evaluating discomfort glare from windows. But former glare indices can not identify the range of the glare source properly. In this study, difference in glare sensation with uniform and non-uniform glare sources are evaluated to identify the range of the glare source. The glare source was assumed as $120{\times}120[cm]$ window model. The window was divided into three parts with different luminance values. The experiment was conducted under 1[m], 1.5[m], 3[m] distance from the glare source. Two results were obtained from the experiments. First, the degree of discomfort glare increased as average window luminance increased. Second, the middle and lower part of the window plane can affect evaluation of discomfort glare as well as the upper part of the window plan. These results can be used for selecting the glare source in a window with non-uniform luminance.

Subjective Appraisals of Discomfort Glare for Luminaire with non-uniform luminance -Effect of luminaire used White LED Light source (불균일한 휘도를 갖는 조명기구에 대한 불쾌글레어 주관평가 실험 -백색 LED 광원을 이용환 조명기구의 영향)

  • Lee, Chang-Mo;Jung, Seung-Gyun;Seok, Dae-Il;Cho, Yong-Ick;Kim, Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.11-14
    • /
    • 2007
  • 현재, 새로운 조명광원으로서 백색 LED가 기대되고 있으며, 이를 이용하는 조명이 확대되어 실용화 될 것으로 예상된다. LED 광원을 이용하여 조명기구를 제작하고 이것을 실내조명으로 사용할 때 조명기구에 의한 글레어가 편안함을 주는지 불편함을 주는지에 대한 평가가 요구된다. 실내 조명환경에 대한 불쾌글레어를 평가하기 위해 UGR(Unified Glare Rating)을 추천하고 있다. 그러나 균일한 글레어 광원의 평균휘도를 이용하여 계산된 종래의 불쾌글레어 평가법들은 불균일한 휘도를 갖는 LED 조명기구에 대해서는 적용하기 어렵게 될 것으로 판단된다. 그래서 UGR를 이용하였을 경우, 균일한 휘도를 갖는 조명기구와 불균일한 휘도를 갖는 조명기구에 대해서 어떠한 차이가 있는지 다음의 불쾌글레어의 주관평가 실험을 수행하였다. 평균휘도가 같고 최대 휘도와 최소 휘도가 다른 조명기구(균일한 휘도를 갖는 조명기구 1종과 불균일한 휘도를 갖는 조명기구 2종)를 글레어 광원으로 사용하였다. 입체각(${\omega}$)과 위치지수(Position Index)를 고정시키고 배경휘도($L_b$)와 광원휘도($L_s$)를 임의로 변화시켰다. 주어진 환경에서 피험자로 하여금 얼마나 편안하진 또는 불편한지에 대한 느낌을 값으로 평가하도록 하였다. 우선, UGR과 주관평가 사이에 차이가 나타났으며, 이는 동 서양에 따른 문화적 및 생리적 차이에 기인한다고 생각된다. 다음으로 균일한 휘도를 갖는 조명기구보다 불균일한 휘도를 갖는 LED 조명기구가 더 높은 값을 할당 받아 LED 조명기구가 불쾌감을 더 유발시키는 것으로 나타났다. 또한 LED 소자 간격에 따른 영향은 글레어 광원의 휘도가 높아질수록 크게 나타났으며, 배경휘도에 대해서도 광원의 휘도가 높아질수록 LED 소자 간격의 차이에 의한 영향이 나타났다. 따라서 UGR식은 균일한 휘도를 갖는 조명기구에 적용하기에는 적합하지만, 불균일한 휘도를 갖는 조명기구에 적용하기에는 부적합하다고 판단된다.

  • PDF

A Development of on Instrument for Measuring Glare Sensation in the Visual Field (시야내의 글레어감각 측정용 기기의 개발)

  • Park, Sung-Ryul;Kim, Jeong-Tai;Kim, Won-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.9-17
    • /
    • 2009
  • Discomfort Glare from the artificial light sources is an important issue in assessment of lighting quality for healthy buildings. Glare, as a factor of the characteristics of brightness, which has been defined as the sensation produced by contrast and luminance within an entire field view, unfavorably influences the occupants who performs visual tasks. It may cause annoyance and discomfort by interruption of visibility. In the whole visual field, glare can be determined by effects of the position, the luminance and the size of the light source and brightness of the surroundings. Therefore, experimental equipment is required to maintain a constant visual lighting environment. Recent studies have been developed and used the instrument for glare sensation evaluation but the instruments showed some difficulties to verify the correlation of glare indicators. The instrument have been developed with reference to former studies. It is called the Glare Tester. This is consist of 2[m]-diameter vertical dome screen painted with white flat paint, and light sources installed inside the screen. These light sources can provide various range of brightness at any inner surface of the screen. 2 Glare light sources can provide the value of luminance within the range of $0{\sim}150,000[cd/m^2]$. Moreover, 12 light sources are used for background luminance and it can perform the value of luminance within the range of $0{\sim}350[cd/m^2]$. Several experiments have been conducted using this Glare Tester to evaluate the range of the visibility, the values of BCD and the glare sensation in lower and upper visual field.

An Assessment of disability glare's impact by road lighting luminaire installed at the guardrail (난간에 설치되는 도로조명기구에 의한 불능글레어의 영향 평가)

  • Seok, Dae-Il;Yoon, Jae-Jung;Lee, Mi-Ae;Kim, Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.141-144
    • /
    • 2008
  • 도로의 난간에 설치되는 조명기구에 의한 불능글레어의 영향을 가로등 조명방식과 비교, 평가하고 글레어 규제를 위한 적정 휘도 범위를 알아내기 위한 시험을 수행하였다. 실내에 시험실을 구축하고, 글레어 유무 시 휘도대비식별역의 변화를 평가하였다. 글레어 광원에 의한 망막조도가 증가하고, 좁은 시야 각 내에 글레어 광원이 존재하면 휘도대비식별역이 증가하였다. 그리고 낮은 위치에 설치되더라도 시야에서 벗어나 있다면 가로등 조명방식에 비해 불능글레어의 영향이 적은 것으로 나타났다.

  • PDF

Study on Sensitivity of Variables of the Experiment to Evaluate Discomfort Glare of Interior Artificial Illumination (건축실내 인공조명의 불쾌글레어 평가실험에 적용된 실험변수의 민감도 분석에 관한 연구)

  • Lee, Jin-Sook;Kim, Won-Do;Kim, Chang-Soon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.24-32
    • /
    • 2008
  • The ultimate purpose of the study is to develop a discomfort glare forecasting formula that can be practically used in Korea in order to effectively forecast discomfort glare considering the optical characteristics of the Koreans. The study was to examine the relations between discomfort glare and the variables such as luminance, background luminance, solid angle, luminous area and louver. To this end, experiments were conducted in a mock-up office that emulates the lighting environment of an ordinary office. The study was conducted by four steps as follow. First, previous studies on discomfort glare rating to define and rate discomfort glare were analyzed and modified to be applied to the experiments of this study. Second, experiment variables, variable scope, evaluation objects and evaluation points were determined after review on existing discomfort glare evaluation experimental formulas. Third, experiments were conducted in a mock-up office to be able to control variables. Finally, sensitivity of experiment variables were analyzed through examination of the relation between discomfort glare and the variables such as luminance, solid angle, louver, luminous area and subject's position. The result showed that the most influential variables on discomfort glare of an artificial light source is luminance and louver, luminous area and subject's position(solid angle) followed.

The Fundamental Research for Discomfort Glare Evaluation of Building Interior Artificial Illumination (건축실내 인공조명의 불쾌글레어 평가를 위한 기초적 연구)

  • Lee, Jin-Sook;Kim, Won-Do;Kim, Byoung-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.27-33
    • /
    • 2006
  • Evaluating comfort of illumination environment of building interior is recognizing the degree of glare causing discomfort. Currently, to use the experimental formula for discomfort glare studied abroad it would be not appropriate because each races feel about the degree of glare differently. Therefore, this study aim to make up prediction formula for evaluating discomfort glare reasonably from Koreans' vision and it proceeded with 4 stages as follows: First, after reviewing the existing discomfort glare evaluation formula, I selected experimental variables. Second, I made a mock-up that I can control experimental variables and conditions according to the purpose of this study. Third, 1 conducted discomfort glare evaluation experiment. Finally, compared with UGR evaluation method suggested for Westerner in prior studies. In conclusion, 1) it's proved that discomfort glare is influenced highly by a light source luminance, background luminance and location of testee and the line of vision. 2) In interior discomfort glare experiment whether the glare light source is placed within range of vision or not has more significant influence than the distance between the light source and testee. 3) I compared and analyzed with UGR, the most representative discomfort glare evaluation system and I found there is a little difference in the results. This shows discomfort glare of Koreans and Westerners are different.

Production of the laboratory that is respected a revision UGR for non-uniform luminance source (불균일 휘도 광원의 UGR 보정을 위한 실험실 구성)

  • Jung, Seung-Gyun;Cho, Yong-Ik;Oh, Suk-Sik;Kim, Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.172-174
    • /
    • 2008
  • 대표적인 신광으로 일컬어지는 LED는 기존 광원과는 달리 다수의 LED 소자가 모여 하나의 광원을 구성하여 조명기구를 이루는 형태를 가지고 있으며 이에 따라 높은 휘도와 낮은 휘도가 반복되는 발광 형태를 가지게 된다. 이러한 불균일한 휘도를 가지는 광원의 경우 일반적인 균일 휘도 광원에 사용되던 UGR의 평가치가 그대로 적용되는 것은 적절하지 못한 글레어의 평가가 이루어질 수 있다. 따라서 이에 대한 보정이 실행되어야 한다. 본 논문에서는 이러한 불균일한 휘도를 가지는 광원에 대해 UGR 글레어 평가식을 보정하기 위한 실험을 수행할 수 있는 실험실을 구성하고 이에 대한 과정을 서술하였다.

  • PDF

Effect of Luminance Difference on Discomfort Glare from a Large Glare Source with Non-uniform Luminance (대광원의 상하부 휘도차가 불쾌글레어 평가에 미치는 영향)

  • Kim, Wonwoo;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.29-34
    • /
    • 2007
  • Discomfort glare from windows is an important issue in window and daylighting design. This study aims to investigate the effect of luminance difference between the lower and the upper part of a large glare source. Experiments were conducted using a luminous body divided into two parts, the upper part and the lower part. The degree of discomfort glare from the luminous body was examined. The result shows that the part with lower luminance is perceived as a glare source when the part has higher luminance then the background luminance. The degree of discomfort glare was estimated for the experimental conditions, and compared to the observations. The estimation was made using two methods: one summed the glare sensation for each section, and the other used the average luminance of the whole luminous body. The result of the comparison shows that the method using the average luminance has approximate values to the observations. Consequently, the use of the average luminance was proposed for evaluation of discomfort glare from non-uniform large glare sources.

Perception of Glare Source According to the Luminance Difference on a Window Plane (창면의 상하부 휘도차에 따른 글레어 광원의 인식변화)

  • Kim, Wonwoo;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.17-22
    • /
    • 2007
  • The existing discomfort glare models are based on research that was conducted exclusively with uniform luminance sources. It is impossible to apply the models to windows of non-uniform luminance. For evaluating discomfort glare from windows, the method selecting glare source on a window plane is necessary. This study was carried outto propose a practical method to choose glare source from anon-uniform window plane. In the experiment, the perception of glare source according to the luminance difference is examined using a simulated windowof non-uniform luminance. The surface of the window is divided into two or three parts, and different luminance is setting on each surface. The observers were asked to decide whether the lower part of the window can be perceived as a glare source or not. The result shows that the lower part is perceived as a glare source when the lower part has over 37% of the luminance of the upper part of the window divided into two parts, and when it has over 51% of the luminance of the upper part of the window divided into three parts. the results may be applicable to select the glare source in awindow.

A Study for assessment of color difference by LED lighting (LED 조명에 의한 색채 변이량 평가)

  • Jung, Seung-Gyun;Kim, Hyun-Ji;Kim, Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.117-120
    • /
    • 2009
  • LED 광원이 일반 조명용으로서 실내조명의 적용도가 증가하면서, LED에 대한 환경적합성 평가의 필요성이 점차 증가하고 있다. 이러한 평가는 LED 조명에서 일반적으로 거론되어지는 광량이나 글레어 발생문제 외에도 조명의 분광분포 특성에 의해 발생하는 색의 보임 차이나 분위기의 변화 등 여러 가지 측면에서 또한 이루어져야 한다. 본 논문에서는 기존광원과 LED 광원간의 색보임의 차이를 위한 실험실을 구축하고 기존 조명과 LED간의 색차를 평가, 분석하였다.

  • PDF