• Title/Summary/Keyword: 근피로도

Search Result 297, Processing Time 0.025 seconds

Real Time Implementittion of Time Varying Nonstationary Signal Identifier and Its Application to Muscle Fatigue Monitoring (비정상 시변 신호 인식기의 실시간 구현 및 근피로도 측정에의 응용)

  • Lee, Jin;Lee, Young-Seock;Kim, Sung-Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.317-324
    • /
    • 1995
  • A need exists for the accurate identification of time series models having time varying parameters, as is important in the case of real time identification of nonstationary EMG signal. Thls paper describes real time identification and muscle fatigue monitoring method of nonstationary EMG signal. The method is composed of the efficient identifier which estimates the autoregressive parameters of nonstationary EMG signal model, and its real time implementation by using T805 parallel processing computer. The method is verified through experiment with real EMG signals which are obtained from surface electrode. As a result, the proposed method provides a new approach for real time Implementation of muscle fatigue monitoring and the execution time is 0.894ms/sample for 1024Hz EMG signal.

  • PDF

Muscle Fatigue Nlonitoring Using a DSP Chip and PC (DSP칩과 PC를 이용한 근피로도 측정)

  • Cho, I. J.;Lee, J.;Choi, Y. H.;Kim, S. H.
    • Journal of Biomedical Engineering Research
    • /
    • v.9 no.2
    • /
    • pp.211-214
    • /
    • 1988
  • As a muscular contraction is sustained, the power spectrum of the myoelectric signal is compressed into lower frequencies. The median frequency appears to be the prefered parameters to monitor this compression. This paper describes a technique and a device which provide an estimate of the median frequency using a TMS32020 DSP chip and IBM PC for tracking of this parameter. Results obtained from myoelectric signal are presented and discussed.

  • PDF

Muscle fatigue monitoring using a DSP chip and PC (DSP칩과 PC를 이용한 근피로도 측정)

  • Cho, I. J.;Lee, J.;Choi, Y. H.;Kim, S. H.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.714-717
    • /
    • 1988
  • As a muscular contraction is sustained, the power spectrum of the myoelectric signal is compressed into lower frequencies. The median frequency appears to be the prefered parameters to monitor this compression. This paper describes a technique and a device which provide an estimate of the median frequency using a TMS32020 DSP chip and IBM PC for tracking of this parameter. Results obtained from myoelectric signal are presented and discussed.

  • PDF

Comparison of the Fatigue According to Activity Lower Extremity Muscle with Treadmill Gait on Type of Shoes Sole Form (트레드밀 운동 시 신발밑창에 따라 일부 하지근육의 활성도에 의한 근피로도 비교)

  • Jeong, Dong-jo;Kim, Keun-Jo;Lee, Cu-Rie
    • Journal of Korean Physical Therapy Science
    • /
    • v.24 no.2
    • /
    • pp.27-35
    • /
    • 2017
  • Purpose: This study aimed to investigate the effect of shoes sole form on fatigue of lower extremity during treadmill gait. Method: Thirty healthy young adults (15 males and 15 females) were recruited. They performed treadmill gait in two different conditions: double sole(DS) and flat sole(FS). Result: lower extremity fatigue were signficantly decreased in double sole condition(p<.05). Conclusion: These findings suggest that double sole contributes to reduction of lower extremity muscle fatigue.

Effect of Heat Stress of Extreme Heat Lever on Muscle functionand Muscle Injury Markers in Elderly Women (열 스트레스가 여성노인들의 근기능 및 근손상에 미치는 영향)

  • Park, Sok;Lee, Chone Ho;Back, Seung Ok;Shin, Yong Up;Kim, Jung Suk;Cho, Young Wung;Lee, Young Jun
    • 한국노년학
    • /
    • v.30 no.3
    • /
    • pp.793-802
    • /
    • 2010
  • The purpose of this study was to examine the influence of extreme heat on muscle function and muscle injury marker in elderly women. The subjects of this study were eight post-menopausal elderly women without any metabolic disease. All eight subjects were asked to perform the knee joint isokinetic exercise using isokinetic equipment (cybex) in the laboratory and experimental temperature within laboratory was adjusted to two conditions: extreme heat temperature(33±0.5℃) and normal temperature(20±0.5℃) maintained in 50±3% humidity conditions. Each experimental exercise was monitored and analyzed the change of HSP70, LDH and CK. Muscular functions (peak torque, total work, percentage of peak torque body weight, fatigue index, average power and total work) were significant differences at exercise between temperatural conditions (p<.05). In extreme heat temperature, muscular injury markers (HSP70, LDH and CK) were increased, threfore resulted in significantly higher than normal temperature(p<.05). These results show that extreme heat temperature can decrease muscle function in elderly women.

건설 중장비 구조물의 신뢰성 평가

  • 고정;조용근
    • Journal of the KSME
    • /
    • v.43 no.6
    • /
    • pp.58-61
    • /
    • 2003
  • 이 글에서는 굴착기의 용접구조물에 대한 필드 하자데이터의 분석과, 용접조인트의 피로이론을 적용한 수명예측, 및 가속수명시험 결과들 사이에 상관관계 분석을 통한 신뢰도 높은 구조물 수명예측 및 검증 프로세스에 관해 소개하고자 한다.

  • PDF

Control of FES Cycling Considering Muscle Fatigue (근피로를 고려한 FES 싸이클링의 제어)

  • Kim Chul-seung;Hase Kazunori;Kang Gon;Eom Gwang-moon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.6 s.171
    • /
    • pp.207-212
    • /
    • 2005
  • The purpose of this work is to develop the FES controller that can cope with the muscle fatigue which is one of the most important problems of current FES (Functional Electrical Stimulation). The feasibility of the proposed FES controller was evaluated by simulation. We used a fitness function to describe the effect of muscle fatigue and recovery process. The FES control system was developed based on the biological neuronal system. Specifically, we used PD (Proportional and Derivative) and GC (Gravity Compensation) control, which was described by the neuronal feedback structure. It was possible to control of multiple joints and muscles by using the phase-based PD and GC control method and the static optimization. As a result, the proposed FES control system could maintain the cycling motion in spite of the muscle fatigue. It is expected that the proposed FES controller will play an important role in the rehabilitation of SCI patient.

Evaluation of Muscle Activity, Muscle Fatigue and Balance in Male High School Taekwondo Athlete with Deformity of Medial Longitudinal Arch (안쪽세로활 변형을 가진 고교 남자 태권도 선수의 근활성도, 근피로도 및 균형의 평가)

  • Won, Seong-Hwan;Yoo, Kyung-Tae;Lee, Ho-Seong
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.16 no.4
    • /
    • pp.85-93
    • /
    • 2021
  • PURPOSE: This study aimed to examine the evaluation of muscle activity, muscle fatigue and balance in male high school Taekwondo athlete with a deformity of the medial longitudinal arch. METHODS: The 20 male high school Taekwondo athletes participated in the study they have been measured radiographic a medial longitudinal arch and divided into a medial longitudinal arch group (higher than 18.8°; MLA group, n = 12) and control group (lower than 18.8°; CON group, n = 8). All subjects were measured muscle activity (TA, PT, PL and PB), muscle fatigue (TA, PT, PL and PB) and balance (A-, AL-, L-, PL-, P-, PM-, M-, AM-direction and composite score; CS). RESULTS: The muscle activity of TP was significantly higher in MLA group compared to CON group (p = 031) and the muscle fatigue of TA was significantly lower in MLA group compared to CON group (p = .043). However, balance did not show significant differences between the groups. CONCLUSION: These results confirmed that male high school Taekwondo athlete with a deformity of medial longitudinal arch increase TP and decrease TA, but there was no difference on balance.

A Study on the Structural Behavior of LB-DECK Panel Considering Rebar-Arrangement in Site (현장 배근이 LB-DECK 패널의 구조거동에 미치는 영향)

  • Lho, Byeong-Cheol;Cho, Gyu-Dae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.3
    • /
    • pp.167-174
    • /
    • 2008
  • The objective of this study is to verify whether the composite action is sufficiently strong to withstand at the interface and the structural behavior of LB-DECK panel with field concrete slab strengthened with main reinforcing bars. Static and fatigue tests are performed for LB-DECK panels with varied shapes and amounts of rebars, and the results are compared with those of field concrete panel(FCP). The test results indicate that the LB-DECK panel with 1.5 times of more rebars inside significantly increase the overall stiffness. LB-DECK penel usually shows on average 52.1 percent of improved stiffness compared with the FCP. The fatigue test results also show that the LB-DECK panel can withstand two-million cycles of repeated loads without any damage.