• Title/Summary/Keyword: 근전도 측정

Search Result 222, Processing Time 0.031 seconds

The Comparative Analysis of EMG Activities on the Lower Limb Muscles during Power Walking and Normal Walking (파워보행과 일반보행 시 하지근의 근전도 비교 분석)

  • Gi, Se-Joon;Chae, Woen-Sik;Kang, Nyeon-Ju;Jang, Jae-Ik;Yoon, Chang-Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.4
    • /
    • pp.125-133
    • /
    • 2008
  • The purpose of this study was to compare EMG activities on the lower limb muscles during power walking and mormal walking. Seventeen subjects who have no known musculoskeletal disorders performed walking exercise at a cadence of 140 beats/min. After surface electrodes were attached to rectus femoris, vastus medialis, vastus lateralis, biceps femoris, tibialis anterior, medial gastrocnemius, averageed IEMG and peak IEMG, were measured. The result showed that the power walking did influence the averaged IEMG and peak IEMG. The EMG activity of the quadriceps during power walking was significantly higher than the corresponding values in normal walking during most phases. The averaged IEMG and peak IEMG of gastrocnemius muscles at the end of the double limb stance increased significantly when going from normal walking to power walking. The results indicate that power walking had greater effect on EMG activities on the lower limb muscles and demonstrate that the wide range of benefits can be obtained from power walking in respect to health and fitness. This study suggests that power walking has the potential to improve aerobic fitness and assist in weight management.

EFFECTS OF ELECTROACUPUNCTURE AND NALOXONE ON MOUTH OPENING REFLEX (전기침과 Naloxone이 개구반사에 미치는 영향)

  • Park, Min-Gap;Seo, Young-Ah;Song, Hyung-Geun;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.467-475
    • /
    • 1998
  • 악안면 영역에 동통이 가하여지면 회피반사의 일종인 개구반사가 유발되며, 개구반사의 크기는 뇌간의 중추에 전달된 동통의 크기에 비례한다. 따라서 동통의 정도를 악이복근의 근전도를 이용하여 정량화 할 수 있고 동통의 지표로 이용할 수 있다. 본 실험은 악안면동통에 의하여 유발된 개구반사의 크기가 침점(족삼리) 전기자극으로 감소되는지와 이러한 전기침의 효과가 나타나는데 opioid 물질이 관여하는지에 대하여 연구하고자 하였다. 8주 이상, 150g이상의 Sprague-Dawley계 쥐 34 마리를 암수 구별없이 이용하여 실험하였다. 복강 내 Urethane용액(1.5g/kg)을 주입 전신마취하고 악이복근을 노출시켜 근전도 기록을 위한 한쌍의 선전극을 삽입하였다. 동통유발을 위하여 구강내 하악 이공주변에 0.1mm의 선전극을 한쌍 삽입하고 전기자극기에 연결하였다. 유해자극 조건은 duration $100{\mu}sec$, interval 5sec의 pulse로 정하고 자극의 크기는 개구반사를 일으키는 역치의 2배 크기로 하며 매 측정시마다 동일 자극을 10회식 가하여 평균하였다. 침점의 전기자극을 위하여 침점의 하나인 족삼리(Zusanli)에 표면전극(넓이 $0.4cm^2$ 정도)을 부착하고 자극부위가 약한 근수축을 일으키는 강도인 $100{\mu}sec$, 5V, 2Hz의 자극을 20분간 가하였다. 악이복근의 근전도는 교류증폭기 (Dam80, WPI, USA) 에서 1000배 증폭하여 유해자극이 가해진 순간 oscilloscope 에서 관찰하여 그 크기를 측정하였다. 침점의 전기자극으로 나타나는 진통효과가 opioid의 분비와 관련있는지 알아보기 위하여 opioid 의 길항제인 naloxone(0.2mg/kg)을 복강 내로 투여하였다. 실험군을 4군(group I - IV)으로 분류하였고 각 군에서 근전도를 측정한 단계는 다음과 같다. group I : control 침점에 전기자극 20 분간 가한후(EA), 20분후(EA20) group II : control 침점에 전기자극 20분간 가한후(EA), naloxone 투여 20분후(NX) group III : control naloxone 투여 5분후 침점에 전기자극 20분 가한후(NxEA20) group IV : control naloxone 투여 20분후(NX20) 구강내에 가해진 유해자극에 의하여 발생하는 악이복근 근전도는 족삼리 침점의 전기자극으로 그 크기가 감소하였고 이러한 침점자극의 효과는 naloxone의 투여로 인하여 억제되었다. 이와 같은 결과는 침점자극으로 진통작용이 나타나는데에 opioid 물질이 관여하고 있음을 시사한다.

  • PDF

A Study on Muscle Fatigue Changes using AR Model-based Median Frequency in EMG (AR모델을 이용한 중앙주파수의 근피로 변화에 관한 연구)

  • Cho, EunSeuk;Cha, Sam;Lee, Sangsik;Lee, Kiyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.1
    • /
    • pp.17-22
    • /
    • 2009
  • In this paper, we extract well-known parameters such as zero crossing rate(ZCR), low band energy(Band) and median frequency(MDF) from surface electromyogram (EMG), and compare to evaluate themselves as measures for fatigue. In experiments, 3 males and 3 females volunteered to participate in surface EMG recordings placed on the biceps brachii and each recording experiment continued until exhaustion.

  • PDF

A Study of Gait Imbalance Determination System based on Encoder, Accelerometer and EMG sensors (인코더, 가속도, 근전도 센서 기반의 보행불균형 판단 시스템 연구)

  • Park, Yong-Deok;Kim, Sang-Kyun;Kwon, Jang-Woo;Lee, Sang-Min
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.2
    • /
    • pp.155-162
    • /
    • 2016
  • The purpose of this study was to determine the walking imbalance using the EMG(electromyogram). To confirm the effectiveness of the proposed encoder and acceleration, EMG sensor based gait imbalance determination system. This experiment was carried out to evaluation with a healthy adult male to 10 people. The Encoder device is attached to the hip and knee joint in order to measure the gait signal. The Accelerometer sensors are attached on the ankle. The EMG sensors are attached on the vastus lateralis and anterior tibialis. SI(Symmetry Index) was used as an index for determining the gait imbalance. To confirm if the judgment has been made correctly, the heel, regarded as the cause of unbalanced ambulation, was adjusted from 0 cm to 6 cm with intervals of 1.5 cm. In the cases of the encoder and the EMG, the difference of 0 cm and 1.5 cm is determined into normal walk but the other difference is distinguished into gait imbalance. In the case of the accelerometer, the difference of 0 cm, 1.5 cm and 3 cm is determined into normal walk but the other difference is distinguished into gait imbalance.

IT based EMG biofeedback training on the effects of upper extremity function in chronic stroke patients (IT 기반 근전도 바이오피드백 훈련이 만성 뇌졸중 환자의 상지기능에 미치는 효과)

  • Kim, Ju-Hong;Oh, Myung-Hwa
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.1
    • /
    • pp.41-50
    • /
    • 2014
  • The subjects of this study were 30 hemiplegia patients whose disease duration was over 6 months, and they were divided at random into a control group (n=15) receiving traditional rehabilitation therapy and an experimental group (n=15) receiving both traditional rehabilitation therapy and training using IT based EMG biofeedback. The program was applied for a total of 4 weeks. In order to examine the subjects' functional recovery, we measured their upper limb function using FMA and MFT, and activities of daily living using FIM before and after the training. Comparison between experimental groups in the study of upper extremity function improved after training in all tests was higher compared to the control group significantly (p<.05), but activities of daily living were not significantly different in. The results of this study were as follows. we concluded that stroke patients receving intensive IT based EMG biofeedback showed upper extremity functional recovery.

A convergence study of the effect of movement control exercise of hip joint using visual EMG biofeedback on hip rotators (근전도 바이오피드백을 적용한 엉덩관절 움직임 조절 운동이 엉덩관절 돌림근에 미치는 영향에 대한 융합적 연구)

  • Jung, Ju-Hyeon;Kang, Tae-Wook
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.12
    • /
    • pp.183-189
    • /
    • 2019
  • The aim of this study was to determine the effects of movement control exercise of hip joint using visual EMG biofeedback on hip joint muscles in healthy adults. This study was nonequivalent one group Pre-post test design. Twenty-one healthy adults were participated in the study. all subjects conducted movemnet control exercise(MCE) using electromyography(EMG) biofeedback of hip joint durng 20 min. The outcome measures included surface eletromyography. Surface electromyography data were collected from the Gluteus medius (Gmed), Gluteus maximus (Gmax),and Tensor fasciae latae(TFL), rectus femoris(RF) during small knee bending (SKB) test. There was a significant difference in Gluteus maximus muscle activity between the pre-test and the post-test (p < 0.05). The findings suggest that Movement control exercise using EMG biofeedback for limiting hip internal rotation is effective in activating the hip external rotator muscles. in addition, this study showed that rehabilitation exercise combined with ICT convergence technology could be an effective intervention in clinical practice.

Proposal of mobile application for rounded shoulder improvement in connection with EMG sensor (근전도 센서를 연동한 둥근 어깨 개선 모바일 어플리케이션 제안)

  • Park, So-Mi;Kay, Yoonshin;Im, Hee-Su;Park, Su-E
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.5
    • /
    • pp.667-676
    • /
    • 2021
  • Recently, adolescents in Korea are exposed to the risk of postural imbalance due to overuse of smartphones and lack of physical activity due to the amount of learning. In addition, the need for effective non-face-to-face exercise services is increasing due to Corona 19. With this in mind, this study proposes an exercise service using an EMG sensor to overcome the limitations of non-face-to-face services while providing the effect of improving round shoulders for adolescents. An exercise program that can improve round shoulders was constructed, and an application in conjunction with an EMG sensor was implemented to exercise effectively. The exercise program was configured to alternately exercise the target muscle area for 4 weeks, and the function to provide feedback was added by measuring the EMG values that change accordingly. Through this study, we intend to provide the basis for exercise-based posture correction digital service, and improve the unbalanced body through this, thereby promoting the possibility of health promotion.

Recognition of hand gestures with different prior postures using EMG signals (사전 자세에 따른 근전도 기반 손 제스처 인식)

  • Hyun-Tae Choi;Deok-Hwa Kim;Won-Du Chang
    • Journal of Internet of Things and Convergence
    • /
    • v.9 no.6
    • /
    • pp.51-56
    • /
    • 2023
  • Hand gesture recognition is an essential technology for the people who have difficulties using spoken language to communicate. Electromyogram (EMG), which is often utilized for hand gesture recognition, is expected to have difficulties in hand gesture recognition because its people's movements varies depending on prior postures, but the study on this subject is rare. In this study, we conducted tests to confirm if the prior postures affect on the accuracy of gesture recognition. Data were recorded from 20 subjects with different prior postures. We achieved average accuracies of 89.6% and 52.65% when the prior states between the training and test data were unique and different, respectively. The accuracy was increased when both prior states were considered, which confirmed the need to consider a variety of prior states in hand gesture recognition with EMG.

Automatic Nerve Activity to Physiologic Response in Adult With Psychiatric Disorder: A Systemic Review (성인 정신장애의 청각자극에 따른 생리학적 반응 측정에 대한 체계적 고찰)

  • Jung, Hye-Rim;Kim, Kyeong-Mi
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.9 no.1
    • /
    • pp.45-52
    • /
    • 2011
  • Objective : The aim of this study was to provide the method to measure physiologic response using equipments and auditory stimulation, and the physiologic response features of adult psychiatric disorders through a systemic review. Methods : The systemic review was executed using PubMed. The key words for search were "auditory stimulation, auditory startle, electromyograph, skin conductance, heart rate, psychiatric disorder, anxiety disorder, schizophrenia, depression". 8 studies were used for data analysis, and all of levels of evidence were level II. The substances of the review were subject(population), auditory stimulation, measure equipments and physiologic response features of psychiatric disorder. Results : 1. The subjects for the studies were anxiety disorder(4) and schizophrenia(4). 2. Auditory stimulation was used in 8 studies and visual stimulation with auditory stimulation was used in 2 studies to induce physiologic response. 3. Every study used electromyograph, and skin conductance was used in 2 studies and heart rate was used in 2 studies with electromyograph to measure physiologic response. 4. The subjects for the studies, schizophrenia and anxiety disorder(PTSD, OCD) have different physiologic response features with the normal control group. Conclusion : All studies used simple tones as an auditory stimulation and electromyograph to measure physiologic response. Psychiatric disorders indicated larger response, shorter and delayed habituation. The objective and systematic study using physiologic measure to investigate the sensory feature of psychologic disorders.

  • PDF