• Title/Summary/Keyword: 근거리 수평사위도

Search Result 18, Processing Time 0.016 seconds

A study on the distance and near horizontal phoria of the young people in Korea (한국 청년의 원거리와 근거리 수평사위에 관한 연구)

  • Kim, Hye-Dong;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.251-255
    • /
    • 2004
  • Our research is about the measurement of the distance & near horizontal phoria by the Von Graefe test. The inspection was processed about normal 60 subjects(120eyes) aged from 20 to 30) years old by the subjective method of refraction. Among 120 eyes, the myopia is 64eyes(53%) and the emmetropia is 56eyes(47%). In the measurement of the distance horizontal phoria, we could know that the exophoria is 40%(24 subjects), the esophoria is 40%(24 subjects), and the orthophoria is 20%(12 subjects). In case of the near horizontal phoria, we could know that the exophoria is 65%(39 subjects), the esophoria is 23.3%(14 subjects), and the orthophoria is 11.7%(7 subjects).

  • PDF

Research About Students' Horizontal Heterophoria in Near Distance with Maddox Rod (Maddox Rod를 사용한 대학생의 근거리 수평사위에 대한 고찰)

  • Choi, Kyong-Seo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.59-63
    • /
    • 2009
  • Purpose: To investigate the near horizontal heterophoria of the college students in their twenties on north Kyonggi Province. Methods: The all subjects had not experienced any ocular surgery and have no disease and their mean age is 22.9. As 122 subjects, they are 50 emmetropes and 72 ametropes. The ametropes are all myopia. After distance visual acuity correction with subjective and objective refraction test, evaluated their horizontal heterophoria with red maddox rod. Results: In maddox rod test, the subjects consist of orthophoria 4.9%, esophoria 9.8% and exophoria 85.3%. In the emmetropes orthophoria is 8%, esophoria is also 8% and exophoria is 84%. In the ametropes orthophoria is 2.8%, esophoria is 11.1% and exophoria is 86.1%. The mean size of horizontal heterophoria is esophoria 3.59PD (prism diopter), exophoria 7.04PD and in the emmetropes esophoria is 3.25PD, exophoria is 6.60PD. In the ametropes esophoria is 3.75PD and exophoria is 7.34PD. Conclusions: In the emmetropoes the orthophoria is more than in the ametropes and the esophoria and exophoria is more in the ametropes. But the differences between the heterophoria and emmetropia or ametropia were not significant (p>0.05). The mean size of heterophoria is higher in the ametropes than in the emmetropoes. The distribution range of heterophoria is wider in the male subjects than the female subjects.

  • PDF

Analysis of far & near distance of lateral phoria by various testing methods (검사 방법에 따른 원·근거리 수평사위의 분석)

  • Hong, Dong-Gyun;Jung, Han-Sub;Park, Sang-An
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.423-430
    • /
    • 2004
  • This Study on three different methods which are Von Graefe test, Maddox Rod test and Howell card test of measuring far and near lateral phoria investigated. It reviewed that 420 subjects aged from 15 to 35 years old. The result were as follows; 1. Using Von Graefe lateral phoria measurement, they were measured 6% for orthophoria, 62% for exophoria, 32% for esophoria at far distance. 2. Using Von Graefe lateral phoria measurement, they were measured 2% for orthophoria, 74% for exophoria, 24% for esophoria at near distance. 3. Using Maddox Rod lateral phoria measurement, they 59% for exophoria, 37% for esophoria at far distance. 4. Using Maddox Rod lateral phoria measurement, they 67% for exophoria, 30% for esophoria at near distance. 5. Using Howell card lateral phoria measurement, they 60% for exophoria, 32% for esophoria at far distance. 6. Using Howell card lateral phoria measurement, they 69% for exophoria, 27% for esophoria at near distance.

  • PDF

A Study About N.P.C, Heterophoria and Near Convergence and Divergence by Amount of the Refractive Errors (굴절이상도에 따른 폭주근점과 근거리 수평사위, 폭주 및 개산 여력의 연구)

  • Choi, Sun-Mi
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.53-57
    • /
    • 2009
  • Purpose: To study the relationship of N.P.C, heterophoria and near convergence and divergence by amount of the refractive error. Methods: All subjects have no ocular disease and their mean age is 22.7. All 39 subjects examined about refractive error, near point of convergence (NPC), heterophoria, near convergence and divergence. Results: Classified by low refractive state, middle refractive state, and high refractive state compared with the expected value of Morgan. NPC had been measured within low and middle refractive state eight all the 8cm. However, high refractive state measured 9.64 cm. Low and middle refractive state for the classification by near phoria. Near esophoria groups was smallest by near divergence and exophoria groups was smallest by near convergence. Conclusions: Near convergence were largest with esophoria while near divergence were largest with exophoria.

  • PDF

Head Posture-Induced Phoria Deviation (머리 위치에 따른 사위도의 변화)

  • Ha, Eun-Mi;Son, Jeong-Sik;Moon, Byeong-Yeon;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.155-160
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate how phoria variations would vary with head positions, as well as to review the need to differentiate prism placement over either eye in a relation to the imbalance of the extraocular muscle. Methods: This study was carried out with 44 males (88 eyes) and 16 females (32 eyes) aged between 20 and 30. For all subjects, testings were performed using cover test, subjective refraction, phoria and vergence test. To analyze phoria variations comparatively for the head tilt test and the face turn test, phoria deviation were measured using the von Graefe. Results: For the phoria variation related with head tilt and face turn, a significant difference was observed in the group judged to be abnormal on the horizontal phoria of Morgan' norm (p<0.05); especially in patients who needed near prescription of Sheard's criterion, a higher variation was observed (p<0.05). The abnormal group was composed of patients who needed distance prescription of Sheard's criterion and ones who did not need the prescription, all of whom showed phoria variations, but the mean value was less than the near. Conclusions: With regard to the head tilt and face turn related phoria level, the patients who needed near horizontal prism prescription of Sheard's criterion showed a remarkably higher variation. Altogether, it is deemed to check whether extraocular muscles are ill-balanced in both eyes previously to determine the prism power on phoria level to the end that each of prism powers may be accurately determined.

Comparisons of Phoria Test Among Prism Settings of Von Graefe Technique (Von Graefe법의 프리즘 세팅에 따른 사위검사의 비교)

  • Yu, Dong-Sik;Ha, Eun-Mi
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.211-218
    • /
    • 2015
  • Purpose: The aim of this study was to compare the differences among prism settings of the von Graefe technique for phoria measurement. Methods: Thirty eight healthy subjects (mean age $22.35{\pm}2.72years$) were tested with eye examination by interview, cover test, and refraction. Phorias were measured in a random order using four prism settings for the von Graefe method: base-in (BI) and base-up (BU), BI and base-down (BD), BU and BI, and BD and BI over the right and left eye, respectively. Results: Among the four prism settings in measurements of lateral and vertical phoria, there were not significant differences at distance, whereas there were significant at near. The reliability of near lateral phoria (ICC: 0.95) was good, but that of near vertical phoria was less reliable (ICC: 0.83). In comparisons of the paired t-test, the 95% limits of agreement, and mean difference between prism settings, BU had more useful than other prism settings at near phoria. Conclusions: Results from this study suggest that the von Graefe test with BU or BU including other setting prisms have useful methods, especially for near phoria measurements.

A Study on The Measurement and Tendency of Horizontal Heterophoria Using Von Graefe Method (Von graefe법을 이용한 사위의 측정과 경향에 관한 연구)

  • Lee, Ki-Seok;Jung, Mi-Boon;Kim, Tae-Hun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.2
    • /
    • pp.151-157
    • /
    • 2006
  • We researched distant & near horizontal heterophoria of myope using von graefe method on full correction condition for young people 49 subjects(98eyes) with myopia after testing the objective refraction. Among the whole subjects, we got the results as Orthophoria 51.00%, Exophoria 38.75%, Esophoria 10.25% and Heterophoria 49.00% at a long distant. At a short distant, they showed Orthophoria 22.45%, Exophoria 67.35, Esophoria 10.20%, and Heterophoria 77.55%, Orthophoria 22.45. At a long distant they showed Orthophoria 4.08%, Exophoria 8.16%, Esophoria 0% on high myopia, Orthophoria 18.37%, Exophoria 12.25%, Esophoria 0% on middle myopia and Orthophoria 28.57%, Exophoria 18.37%, Esophoria 10.20% on low myopia.

  • PDF

The Change in Far Distance and Near Distance of Exophoria Patients (외사위 환자의 원거리와 근거리 때의 변화)

  • Seong, Jeong-Sub;Hong, Soo-Hak
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.143-147
    • /
    • 2002
  • A36 patients of a total of 60 persons show $2{\Delta}$ and less, and the rest of 24 patients show $6{\Delta}$ and less. The patient, who increase more in near distance than far distance in exophoria amount are 27 persons. The unchanging patients are 13 persons, and the patients who phoria amount decreasing are 20 persons. Like this, the patients who phoria amount unchange and decrease show more than the half. That is why convergence increases in near distance. The expected value of horizontal phoria in near distance is $3exo{\pm}3$. Only 13 patients get rid of its value, 47 satisfy its value. In AC/A value, 35 persons show under 3(1ow), 21 persons show 3~5(normal), and 4 persons show more than 5(high). By Percival's theory, 36 patients don't feel a slight asthenopia without correcting phoria. Finally, in near point of convergence 27 patients show 10cm and less, 24 patients show 11~15cm, 3 patients show 15~20cm, and 6 patients show 21~25cm. Most of them show high accommodation.

  • PDF

The Effects of Visual Training on Binocular Anomalies (양안시 기능 이상의 시훈련(Visual Training)의 효과)

  • Kim, In-Suk;Hong, Dong-Gyun;Kim, Jung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.1
    • /
    • pp.53-61
    • /
    • 2005
  • In this study, we measured Near Point of Convergence(N.P.C) tests, Phoria tests using Von Grafe method and relative convergence tests on 138 men and 162 women, so a total of 300 subjects aged between 8~45 to examine the improvement of the fusion vergence through visual training and obtained as follows. 1. According to the results, the near point of convergence of 57 (19%) subjects were shorter than 7cm, and 243 (81%) were 7cm or longer, having a problem in convergence. After visual training, the number of subjects have the value shorter than 7 cm increased from 57 to 111 (37%), and the number of those have the value 7cm or longer decreased significantly form 243 to 189 (63%). 2. The results of the measure of lateral Phoria at far distance by Von Grafe method showed orthophoria 18 (6%), exophoria 198 (66%), esophoria 84 (28%). After phoria test, we examined the N.R.C and P.R.C test. The results showed that the hope finger was improved after V.T using B.l, B.O card. 3. The results of the measure of lateral Phoria at near distance by Von Grafe method showed orthophoria 6 (2%), exophoria 222 (74%), esophoria 72 (24%). After phoria test, we examine the N.R.C and P.R.C test. The results showed that the hope finger was improved after V.T using B.I, B.O card.

  • PDF

Comparison between Stimulus and Response AC/A Ratios for Each Phoria with Additional Spherical Power (사위별 가입렌즈에 따른 자극 AC/A비와 반응 AC/A비의 비교)

  • Lee, Se-Hee;Yu, Dong-Sik;Son, Jeong-Sik;Kwak, Ho-Weon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.345-351
    • /
    • 2014
  • Purpose: The accommodative response and the near horizontal phoria were examined with additional spherical power to analyze the stimulus and response AC/A ratios that suggest reference data for the binocular vision. Methods: The open-field autorefractometer (Nvision-K 5001, Shin nippon) and modified thorington method (MIM card; Muscle Imbalance Measure card, Bernell) at 40 cm were utilized to measure the accommodative response and the near horizontal phoria for 81 persons ($20.89{\pm}1.92$ years old) with additional spherical power. The stimulus and the response AC/A ratios were calculated by gradient AC/A method. Results: The exophoria group showed the highest accommodative response ($1.92{\pm}0.26D$) at 40 cm, followed by orthophoria group and esophoria group($1.72{\pm}0.26D$ and $1.62{\pm}0.42D$, respectively) Meanwhile, the esophoria group showed the biggest ocular deviation for the near ($23.24{\Delta}$) followed by the orthophoria group and exophoria group ($19.76{\Delta}$ and $15.14{\Delta}$, respectively). The biggest difference of the stimulus and the response AC/A ratios was $1.72{\Delta}$ for the exophoria group with -2.00 D, while the one was $3.43{\Delta}$ for the esophoria group with +1.00 D. There was a significant difference between AC/A ratios for the exophoria group with -2.00 D, -1.00 D and the esophoria group with +3.00 D, +2.00D, +1.00D and -1.00D. Conclusions: The difference between stimulus and response AC/A was greater when increased minus spherical power for the exophoria group, while it was greater when increased plus spherical power for the esophoria group. Furthermore, the difference for the esophoria group was a greater than the one for the exophoria group.