• Title/Summary/Keyword: 극저기압

Search Result 6, Processing Time 0.025 seconds

Analysis of Snowfall Development Mechanism over the Korean Peninsula due to Polar Low (극저기압에 의한 한반도 강설 발달기구 분석)

  • Kim, Jinyeon;Min, Ki-Hong
    • Journal of the Korean earth science society
    • /
    • v.34 no.7
    • /
    • pp.645-661
    • /
    • 2013
  • The synoptic, thermodynamic, and dynamic characteristics of a heavy snowfall event that occurred in Seoul metropolitan area on 27 to 28 December 2010 was investigated. During this period there was a distinctive case that was identified as a polar low. We analyzed surface and upper level weather charts, snowfall amount, sea surface temperature, satellite imagery, sounding, and the National Center for Environmental Prediction global $1^{\circ}{\times}1^{\circ}$ reanalysis data. The polar low developed in an area where there was strong baroclinicity in the lower level aided by strong conditional instability due to 925 hPa warm air advection and 700 hPa cold air advection. The development mechanism of polar low is due, in part, to the tropopause folding, which advected stratospheric air increasing potential vorticity in mid-level and inducing cyclonic vorticity and convergence in low-level. Eventually clouds developed and there were snowfall total of 10 cm in Seoul metropolitan area and as much as 20 cm in southern parts of Korea. During the snowfall development, there was a $-45^{\circ}C$ cold core at 500 hPa and shortwave maintained $3-5^{\circ}$ separation with surface trough, which favored the development of polar low located in the warm sector and cyclonic advection area. The height of the dynamical tropopause lowered to 700 hPa during the peak development and increase in potential vorticity allowed strong vertical motion to occur. Overall, there was a close relationship between the development of snowfall and tropopause undulation. The heaviest snowfall occurred east of the tropopause folding where strong cyclonic vorticity, vertical motion, and moisture advection all coincided while the polar low was passing through the Korean peninsula.

Research of Cryogenic Helium Refrigerator System for SQUID (SQUID 냉각장치용 극저온 시스템 개발)

  • Lee, Kum-Bae;Baek, Il-Hyun
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.18 no.2
    • /
    • pp.121-129
    • /
    • 1989
  • 헬륨을 이용한 극저온 냉동기는 압축기(compressor)을 통하여 압력을 10-20 기압 정도로 높혀준후 여러 단계의 열교환기(heat exchanger)를 통하여 상전위온도(maximum inversion temperature) 이하로 떨어뜨린후 Joule-Thomson 밸브를 통하면 4K까지 온도가 떨어진다. 이때 압력은 1기압 정도이며 헬륨가스는 액체로 변한다. 본 연구의 목적은 Gifford-McMahon 냉동기와 Joule-Thomson 냉동기의 혼합형인 극저온 냉동기를 설계, 제작하여 죠셉슨(Josephson) 소자를 이용한 SQUID(초전도양자 간섭장치), 여러 종류의 탐지기, 컴퓨터 소자 개발 등을 위한 냉동기로 사용하는데 그 목적이 있다. 개발되는 법동기의 용량은 1 W이며, 최저온도는 4K 정도가 된다.

  • PDF

A Case Study on the Polar Low Developed over the Sea Near Busan on 11~12 February 2011 (2011년 2월 11~12일 부산 근해에서 발달한 극저기압에 대한 사례연구)

  • Lee, Jae Gyoo;Kim, Hae-Min;Kim, Yu-Jin
    • Atmosphere
    • /
    • v.26 no.2
    • /
    • pp.301-319
    • /
    • 2016
  • The evolutionary process of the polar low, which caused the heavy snowfall in the East Coast area on 11~12 February 2011, was investigated to describe in detail using synoptic weather charts, satellite imageries, and ERA (European Centre for Medium-Range Weather Forecasts Re-Analysis) -Interim reanalysis data. It was revealed that 1) the polar low was generated over the sea near Busan where a large cyclonic shear in the inverted trough branched from the parent low existed, 2) during the developing and mature stages, there was a convectively unstable region in the lower layer around the polar low and its south side, 3) the polar low was developed in the region where the static stability in the 500~850 hPa layer was the lowest, 4) the result from the budget analysis of the vorticity equation indicated that the increase in the vorticity at the lower atmosphere, where the polar low was located, was dominated mainly by the stretching term, 5) the warm core structure of the polar low was identified in the surface-700 hPa layer during the mature stage, 6) there was a close inverse relationship between a development of the polar low and the height of the dynamic tropopause over the polar low, and 7) for generation and development of the polar low, large-scale circulation systems, such as upper cold low and its combined short wave trough, major low (parent low), and polar air outbreak, should be presented, indicating that the polar low has the nature of the baroclinic disturbance.

Analysis of the Maximum Electric Field for Changing Pressure using Breakdown Characteristic of $N_2+SF_6$, $N_2+CF_4$, $N_2$ Gases in a Cryogenic Environment (극저온 환경을 고려한 기압별 $N_2+SF_6$, $N_2+CF_4$, $N_2$가스의 절연파괴 전압 값을 이용한 최대전계 분석)

  • Oh, Seok-Ho;Lee, Sang-Hwa;Shin, Woo-Ju;Park, Tae-Gun;Seong, Jae-Kyu;Hwang, Jae-Sang;Lee, Bang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1548-1549
    • /
    • 2011
  • High voltage cryogenic insulation issues need to be addressed in order to promote the commercialization of high temperature superconducting (HTS) equipment. As a fundamental step in the development of the optimum bushings for HTS devices, the breakdown characteristics of liquid nitrogen mixed with liquefied insulating gases such as $N_2$, $SF_6$, and $CF_4$ have been investigated. In order to investigate the possibility of substituting $CF_4$ gas for $SF_6$ gas for the bushings of HTS electrical equipment, AC withstanding voltage tests have been performed. In this paper, finding the maximum electric field $E_{max}$ using utilization factor ${\eta}$. This result is applicable to developing the real scale HTS equipment of the design parameters.

  • PDF

Modeling of Thermodynamic Properties of Saturated state Hydrogen using Equation of State (상태방정식을 이용한 포화상태 수소의 열역학적 물성 모델링)

  • Bong-Seop Lee;Hun Yong Shin;Choong Hee Joe
    • Korean Chemical Engineering Research
    • /
    • v.61 no.4
    • /
    • pp.550-554
    • /
    • 2023
  • Fossil energy sources are limited in their sustainable use and expansion due to global warming caused by carbon dioxide emissions. Hydrogen is considered as a promising alternative to traditional fossil fuels. To ensure the stable long-term storage, it is necessary to accurately predict its thermodynamic properties at cryogenic temperatures. Therefore, this study aimed to investigate thermodynamic properties, such as saturated vapor pressure and density, enthalpy, and entropy of liquid and gas, using cubic equations of state that demonstrate relatively simple relationships. Among the three types of equations of state (Redlich-Kwong (RK), Soave-Redlich-Kwong (SRK), and Peng-Robinson (PR)), the SRK model exhibited relatively accurate prediction results for various physical properties.

Pulmonary Thromboendarterectomy for Pulmonary Hypertension Caused by Chronic Pulmonary Thromboembolism (만성폐색전중으로 인한 폐동맥고혈압 환자에서 시행한 폐동맥내막절제술)

  • Song Seung-Hwan;Jun Tae-Gook;Lee Young-Tak;Sung Ki-Ick;Yang Ji-Hyuk;Choi Jin-Ho;Kim Jin-Sun;Kim Ho-Joong;Park Pyo-Won
    • Journal of Chest Surgery
    • /
    • v.39 no.8 s.265
    • /
    • pp.626-632
    • /
    • 2006
  • Background: Pulmonary hypertension caused by chronic pulmonary embolism is underrecognized and carries a poor prognosis. Medical therapy is generally unsatisfactory and palliative. With the improvement of operative technique and postoperative management, pulmonary endarterectomy has been the treatment of choice for this condition. Material and Method: Between January 2001 and December 2005, eleven patients were received pulmonary endarterectomy. All patients had chronic dyspnea and exercise intolerance. Diagnosis was made with cardiac echocardiography, lung perfusion scan and computed tomography. Before the operation, Greenfield vena cava filter were placed in all patient except one. Deep hypothermic circulatory arrest was used for the distal-most portion of the endarterectomy procedure. More than moderate degree of tricuspid reguirgitation was repaired during operation. Result: There was no early and late death. Right ventricular systolic pressure was reduced significantly after operation from $91{\pm}21$ mmHg to $40{\pm}17$ mmHg on echocardiography (p=0.001). NYHA class and tricuspid reguirgitaion were improved postoperatively. Although mild reperfusion injury in three case and postoperative delirium in one case were observed, all of them recovered without complication. Conclusion: Pulmonary thromboendarterctomy offers to patient an acceptable morbidity rate and anticipation of clinical improvement. This method is safe and effective operation for pulmonary hypertension caused by chronic pulmonary thromboembolism.