• Title/Summary/Keyword: 균열 길이

Search Result 528, Processing Time 0.03 seconds

Measurement of Interfacial Crack Length by Ultrasonic Scattering Compensation Depending on Thickness Variations of Bonded Dissimilar Components (이종 접합부재의 두께 변화에 따른 초음파 산란 보정에 의한 계면균열 길이의 측정)

  • Chung, Nam-Yong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.2
    • /
    • pp.67-75
    • /
    • 2006
  • In this paper, the compensation of ultrasonic scattering on interface crack depending on thickness variations of A1/Epoxy bonded dissimilar components was applied to improve measuring accuracy by using ultrasonic attenuation coefficient. The optimum conditions of theoretical value and experimental measuring accuracy by the ultrasonic method in A1/Epoxy bonded dissimilar components have been investigated. From the experimental results, the measurement method of interfacial crack lengths by using ultrasonic attenuation coefficient was proposed and discussed. After the ultrasonic scattering compensation depending on thickness variations of bonded dissimilar components was carried out, the measuring accuracy of interfacial crack length was improved by 5%.

A Study on the Characteristics of Fatigue Failure for Fillet Welded Joint (필릿 용접이음부의 피로파괴 특성에 관한 연구)

  • Kang, S.W.;Ha, W.I.;Shin, J.S.;Jang, T.W.;Jae, J.S.
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.33 no.4
    • /
    • pp.133-141
    • /
    • 1996
  • The mode of fatigue failure is depended on the characteristics of the fatigue crack initiated and propagated from the weld toe and the weld root in the load-carrying fillet welded joints. The characteristics of fatigue crack are deeply affected by the geometry of fillet and the stress range. The purpose of this study is to investigate critical weld size and stress range in order to occur toe failure under pulsating tension loading in the load-carrying fillet welded cruciform joints.

  • PDF

Effect of Hydride of the PHWR Pressure Tube on the LBB Evaluation (중수로 압력관의 수화물이 LBB평가에 미치는 영향)

  • Oh, Dong-Joon;Kim, Young-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.5
    • /
    • pp.610-616
    • /
    • 2004
  • The aim of this study was to investigate the hydride embrittlement when the LBB evaluation was carried out for the integrity of PHWR Pressure Tubes. The transverse tensile and CCT toughness tests were performed at three hydrogen concentrations while the test temperatures were changed (RT to 30$0^{\circ}C$). Both the transverse tensile and the fracture toughness tests showed the hydrogen embitterment clearly at RT but this phenomenon was disappeared while the test temperature arrived at 25$0^{\circ}C$. Using the DHC test results, the CCL and LBB time were calculated and compared. The hydride embrittlement at the LBB evaluation made the LBB time short definedly. If the operating temperature, DHCV and LBB deterministic parameters such as A and m were known, LBB time could be estimated without the calculation of CCL.

Fundamental Characteristics of Crack Control for Concrete Used in Fluosilicate Salt Based Anti-crack Agent (규불화염계 균열저감제를 이용한 콘크리트의 균열제어특성)

  • Kang Sung Woong;Yang Il Seung;Han Byung Chan;Kim Do Soo;Kil Bae Soo;Yun Hyun Do
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.289-292
    • /
    • 2004
  • This study was performed to know effective control of crack occurred by hydration heat, restraint of multiplication of hydration heat, through mechanical test, strength test and crack control test using fluosilicate salt based anti-crack agent made from by-product during phosphoric acid manufacturing process. Mix proportions for experiment were modulated at 0.495 of water to cement ratio and addition amount of fluosilicate salt based anti-crack agent to $1.0\%$. Condensation time was late and compressive strength of hardened concrete cured at several days was executed to evaluate characteristics of crack control for concrete. It is ascertained that characteristics of crack control for concrete could be improved by an adequate addition of fluosilicate salt based anti-crack agent.

  • PDF

안전주입 및 정지냉각 배관의 LBB 적용을 위한 배관평가선도 개발

  • 허남수;서명원;김영진;표창률;박상덕
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11b
    • /
    • pp.697-702
    • /
    • 1996
  • 원전 배관계통에 LBB를 적용하면 배관파단으로 인한 동적영향(dynamic effect)을 고려하지 않아도 되므로 각종 구조물의 설계가 단순해지고, 배관파단에 대비해 설치하였던 각종 지지구조물들을 제거할 수 있으므로 설계비용 절감 등 경제적 이점을 얻을 수 있다. 본 논문의 목적은 차세대원전 안전주입 및 정지냉각계통 배관에 대해 설계초기단계에서 LBB적용 여부를 판단할 수 있는 배관평가선도를 개발하는 것이다. 이를 위해 먼저 배관재료의 응력-변형률곡선을 사용하여 감지가능한 균열길이를 산출하였으며, 3차원 유한요소해석과 배관재료의 파괴저항곡선을 이용한 균열안정성평가를 수행하여 배관평가선도를 개발하였다. 본 연구에서 개발한 배관평가선도를 배관설계초기단계에 사용하면 LBB적용여부로 인한 설계변경과정이 불필요하므로 전체공기를 단축할 수 있으며, 특정한 배관계통이 아닌 일반 배관계통에 적용할 수 있으므로 LBB해석회수를 상당히 줄일 수 있다.

  • PDF

Evaluation of Half Cell Potential Measurement in Cracked Concrete Exposed to Salt Spraying Test (염해에 노출된 균열부 콘크리트의 반전위 평가)

  • Kim, Ki-Bum;Park, Ki-Tae;Kwon, Seung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.6
    • /
    • pp.621-630
    • /
    • 2013
  • Several techniques for steel corrosion detection are proposed and HCP (half cell potential) technique is widely adopted for field investigation. If concrete has cracks on surface, steel corrosion is rapidly accelerated due to additional intrusion of chloride and carbon dioxide ions. This study is for an evaluation of HCP in cracked concrete exposed chloride attack. For this work, RC (reinforced concrete) beams are prepared considering 3 w/c ratios (0.35, 0.55, and 0.70) and several cover depths (10~60 mm) and various crack widths of 0.0~1.0 mm are induced. For 35 days, SST (salt spraying test) is performed for corrosion acceleration, and HCP and corrosion length of rebar are evaluated. With increasing crack width, w/c ratios, and decreasing cover depth, HCP measurements increase. HCP evaluation technique is proposed considering the effects of w/c ratios, crack width, and cover depth. Furthermore anti-corrosive cover depths are obtained through Life365 program and the results are compared with those from this study. The results shows relatively big difference in cracked concrete, however provide similar anti-corrosive conditions in sound concrete.

Experimental Investigation of the Residual Stress on Fatigue Crack Growth of Welded Steel Members (용접(鎔接) 강부재(鋼部材)의 피로균열성장(疲勞龜裂成長)에 대한 잔류응력특성(殘留應力特性)에 관한 연구(硏究))

  • Chang, Dong Il;Kim, Doo Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.99-106
    • /
    • 1987
  • Annealing were performed to investigate the behaviors of the residual stress remaining on the member of a steel structure. According to the fatigue test, the welding part has higher fatigue crack growth rate than the base metal part because the hardening of welding part reduce fracture toughness. However, the heat treatment decrease the hardness and increase the resistance to failure. Thus, the fatigue crack growth rate is improved and it reaches the minimum at $650^{\circ}C$. Elber' s equation includes the effect of the crack-close so that this equation provides a lower the fatigue crack growth rate than Paris-Erdogan' s equation, the Elber's curves show no significant difference to indentify the effect of the residual stress. The Pop loading along the crack length increases as the hardness goes higher. The heat treatment not only decrease the hardness, and the fatigue crack growth rate, but increase the absorption energy and fracture toughness on the member of a steel structure. As the result, the heat treatment produces the resistant ability to cracking which can reduce the degree of danger to failure.

  • PDF

A study on the occurrence of cracks in the tunnel pavement in the soil under use (토사구간 공용중 터널 포장부 균열 발생에 관한 연구)

  • Kim, Nag-Young;Lee, Kang-Hyun;Cho, Nam-Hun;You, Kwang-Ho;Baek, Seung-Chol
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.5
    • /
    • pp.749-760
    • /
    • 2017
  • Recently, the proportion of tunnel structures in roads and railways has increased rapidly. Along with this trend, the rate of occurrence of cracks and dropouts in concrete lining of tunnel structures is increasing. Generally, maintenance of such concrete lining is normalized and managed as the core of maintenance work in tunnel maintenance. However, the maintenance of the tunnel pavement is important in securing driver in the tunnel. In the design of tunnels, the underground condition of the tunnel is designed to be in good rock condition, so there have not been many cases of cracks in the tunnel pavement in the past. Recently, the construction of tunnel structures has been rapidly increased, and the length of the tunnels has become longer.Tunnel pavement installed in these ground conditions is increasing the occurrence of cracks in the pavement due to decrease of bearing capacity of the pavement after a long time. In this study, FWD and GPR were conducted to analyze the types of cracks and the reduction of bearing capacity in the tunnel.

Influence of Transverse Reinforcement Elements for Flexural Strength of Lap Spliced Ultra-high-strength Reinforced Concrete Beams (겹침이음된 초고강도콘크리트 보의 휨강도에 횡방향보강 요소가 미치는 영향)

  • Bae, Baek-Il;Choi, Hyun-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.5
    • /
    • pp.135-142
    • /
    • 2022
  • In this study, lap spliced ultra-high strength reinforced concrete beams were tested and the code criteria for calculating the lap splice length which was affected by the transverse reinforcement and concrete covering performance were reviewed. The main variables for test were set as fiber volume fraction and transverse reinforcing bar arrangement to improve the confining performance of the concrete cover. The change of the confining performance of concrete cover according to the increase in the fiber mixing amount at 1% and 2% volume ratio was examined, and D10 stirrups with a spacing of 100 mm were placed in the lap spliced region. As a result of the test, the specimens confined by the stirrups showed a sudden drop of load bearing capacity with horizontal cracking at the position of tensile longitudinal reinforcement. However, horizontal cracks were not appeared at the location of longitudinal reinforcement for the specimens with steel fiber. And these specimens showed gradual decrease of load bearing capacity after experiencing peak load. In particular, it was found that the strain at the position of the tensile longitudinal reinforcements of the specimens to which the mixing ratio of 2% was applied exceeds the yield strain. As a result of measuring the strain on the concrete surface, it was found that the fiber was more effective in preventing damage to the concrete surface than the stirrups for short lap spliced region.

Continuity for Double Tee Slabs (더블티 슬래브의 연속화)

  • 유승룡
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.2
    • /
    • pp.99-106
    • /
    • 2001
  • The main objective of this study is to develop a continuity of double tee slab with two modified dap-ends to solve the problems of excessive moment, slab depth, deflection, and joint cracking in the original simply supported double tee slab systems. The modified joint is produced in a combination with two slabs with modified dap and one rectangular beam. The modified joint can be justified as following different merits. The span capacity for a design load is increased, while the deflection of the slab is decreased due to the decrease of positive moment at the center span of the slab. The joint cracking between slab and beam, which occur frequently in the original slab systems of double tee will be reduced. No more additional form work is needed to cast topping concrete for continuity. Three point loading tests are performed on the specimens with a variable of an amount of main longitudinal reinforcement to evaluate flexural and shear behavior. Following conclusions are obtained from the experimental investigation. The continuity of double tee slab effectively is provided by placing longitudinal steel reinforcement in the topping concrete over the connection, and generally leads to an increase in span capacity of double tee slabs with reduced deflection. It is more effective to control the initial cracking at the connection than that of some simply supported double tee slab systems.