• Title/Summary/Keyword: 굵은 순환골재

Search Result 130, Processing Time 0.028 seconds

Experimental Study on Structural Performance of Recycled Coarse Aggregate Concrete Confined by Steel Spirals (나선철근으로 횡구속된 순환골재 콘크리트의 구조적 성능에 관한 실험적 연구)

  • Kim, Sang Woo;Jung, Chang Kyo;Lee, Sun Hee;Kim, Kil Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.103-111
    • /
    • 2011
  • This paper estimated the structural behavior of recycled aggregate concrete confined with spiral reinforcement. The main test parameter was designed to be the type of aggregates and the steel ratio of spirals. A total of 18 specimens were cast and tested in this study. All the specimens had a diameter of 150mm and a height of 300mm. The specimens can be divided into two groups, based on the type of coarse aggregate used. The ratio of spiral reinforcement was varied from 0 % to 1.75%. To measure the axial and lateral deformations of the specimens, a total of six linear variation displacement transducers (LVDTs) were installed at each specimen. Furthermore strain gauges were also attached to the steel spirals to obtain the strain of spiral reinforcements. From the experimental results, the structural performance of recycled aggregate concrete specimens confined by steel spirals was similar to that of natural aggregate concrete specimens regardless of the ratio of spiral reinforcement.

A Study on Aggregate Waste Separation Efficiency Using Adsorption System with Rotating Separation Net (회전분리망 흡착선별기의 순환 굵은골재 이물질 제거효율에 관한 연구)

  • Cho, Sungkwang;Kim, Gyuyong;Kim, Kyungwuk;Seon, Sangwon;Park, Jinyoung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.1
    • /
    • pp.85-91
    • /
    • 2021
  • Aggregate waste separator with rotating separating net was designed for applying classification process of construction waste. In order to evaluate the performance of the aggregate waste separator, according to the type of waste, standardized waste samples are prepared using acrylic. The appropriate operating point was evaluated by the classification efficiency and misclassification rate of recycled aggregate according to the control frequency of the blower operating and inlet position of the separating net. The classification efficiency at the operating point of the aggregate waste separator was evaluated through flow analysis assuming recycled aggregate and waste sample as particles. As a result of the performance test, when the distance. between the conveyor belt and the inlet was 0.2m, the classification efficiency was 95%, but the misclassification rate of recycled aggregate was 2% or more, which satisfies the classification efficiency and the misclassification rate of less than 2%. The operating point was shown at a control frequency of 58Hz at a suction distance of 0.254m. As a resu lt of flow analysis, there was no misclassification of recycled aggregate. In order to redu ce constru ction waste in the existing recycled aggregate production process, adsorption system using a rotating separating net that can be operated as an installation type was built.

The Time Dependent Deflection Characteristics and Evaluation of Reinforced Recycled Aggregate Concrete Beams (순환골재를 사용한 철근콘크리트 보의 장기 처짐 특성 및 평가)

  • Ji, Sang-Kyu;Yun, Hyun-Do;Kim, Sun-Woo;Lee, Eon-Young
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.1
    • /
    • pp.43-50
    • /
    • 2008
  • This paper presents experimental and analytical results on the long-term behavior of the reinforced recycled aggregate concrete beams under sustained loading. In this experimental program, three beams with different conditions of aggregates replacement (natural aggregate 100%, recycled coarse aggregate 100%, recycled fine aggregate 50%) were subjected to the sustained flexural loading that was a half of the nominal flexural capacity over a period of 1 year. The beam were designed with net span of 2,000 mm and rectangular cross-section of 170 mm width and 170 mm effective depth. The beams were instrumented and monitored to observe the change in the long-term behavior due to creep and shrinkage of concrete under sustained loading. The predictions of long-term deflection by ACI code, Branson, Mayer, Neville, EMM and AEMM were compared with the experimental results. From the experimental results, the reinforced concrete beams with recycled aggregates showed the same performance as that of a beam with natural aggregate. The proposed method to predict the long-term deflections of reinforced recycled aggregate concrete beams gives a good estimation for experimental results.

Analysis of Fundamental Properties of Concrete Using Mix of Coarse Aggregate With Formation Causes (성인이 다른 굵은 골재를 혼합사용한 콘크리트의 기초적 특성 분석)

  • Noh, Sang-Kyun;Kim, Young-Hee;Kim, Jeong-Bin;Han, Cheon-Goo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.1
    • /
    • pp.15-21
    • /
    • 2015
  • Recently, attempts of replacing some of natural aggregate with mix of low quality aggregate are carried out for stable supply of aggregate. However, low quality aggregate such as recycled aggregate produced during the disposal process of construction wastes and by-product aggregate produced by industrial activities has problem of failing to comply to KS Standards. Therefore, we have compared fundamental properties of concrete by using granite crushed aggregate, recycled aggregate, blast furnace and electric arc furnace slag aggregate for effective utilization of lacking aggregate resources. As the result, slump in case of mixed use of aggregate was increased 0~10% compared to single use. Therefore, it is judged to be economically advantageous as it can expect effects in unit quantity or reduction of SP agent. Compressive strength in case of mixed use of aggregate was increased 0~10% compared to single use as it filled internal crevice of concrete with continuous particle size distribution. Accordingly, if we utilize by satisfying standard particle scope through mix of aggregate with different cause of formation in proper ratio, it was possible to confirm utility of mixed aggregate with demonstration of effects of increases of fluidity and compressive strength of concrete.

Analysis of Damage Levels with Bond Performance between Reinforcement and Recycled Coarse Aggregate Concrete (순환굵은골재 콘크리트와 이형철근의 부착거동시 손상단계 분석)

  • Lee, Min-Jung;Yun, Hyun-Do;JAng, Yong-Heon;Choi, Ki-Sun;You, Young-Chan;Lee, Do-Heun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.863-866
    • /
    • 2008
  • One of the most important requirements for reinforced concrete constructions is the bond behavior between concrete and reinforcement. In this study, the positions (i.e., vertical, horizontal) and the locations (i.e., 225mm and 75mm) of reinforcement were considered as a main test parameter. The ready mixed recycled aggregate concrete concrete with specified strength of 21MPa was prepared with different replacement ratio(i.e 0%, 100%) of recycled coarse aggregate. From the test results, it was bond that under the same mix proportion (i.e., the mix proportions are the same, except for deformed bars position), the bond strength between the recycled coarse aggregate concrete and the reinforcement has obvious relation with reinforcement position. Also, the specimens of top position showed a lower bond stress than that provided in CEB-FIP Code.

  • PDF

Bond between Reinforcing Bars and Recycled Coarse Aggregate Concrete with respect to Reinforcement Location (철근의 위치에 따른 이형철근과 순환굵은골재 콘크리트의 부착특성)

  • Yun, Hyun-Do;Lee, Min-Jung;Jang, Yong-Heon;Bae, Kee-Sun;You, Young-Chan;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.1093-1096
    • /
    • 2008
  • This study investigated the bond behavior between recycled coarse aggregate (RCA) concrete and deformed reinforcing bars. The position (i.e., vertical, horizontal) and the location (i.e., 375mm, 225mm and 75 mm) of deformed bar were considered as a main test parameter in this paper. From the test results, it was found that maximum bond strength of top reinforcement was decreased compared with that of bottom reinforcement. Also bar embedded horizontally 225mm above from base could not satisfy bond strength requirement provided in CEB-FIP code. It was caused by the fact that bonded area at the bottom of horizontal reinforcement was significantly reduced by the poring water and laitance. In this specimen, the bond strength provided by bearing stress and wedging action of concrete was not fully observed.

  • PDF

Effect of the Broken Red Bricks on the Mechanical Properties of Reinforced Concrete Beams (부순 적벽돌 혼입량에 따른 철근콘크리트 보의 역학적 특성에 관한 연구)

  • Kim, Jeong Sup;Shin, Yong Seok;Cho, Cheol Hee;No, Sung Yeol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.2
    • /
    • pp.83-90
    • /
    • 2008
  • The purpose of this study is to attempt to use broken red brick, which is categorized as impurities of circular aggregate to thick aggregate, as a replacement for concrete. Through the material test and performance test for each mixing rate of the broken red brick (0%, 30%, 60%), the following conclusion was reached by studying the material and structural characteristics of circular aggregate to the concrete. Even though broken red brick, which is categorized as impurities of circular aggregate, is mixed 30% with normal rubble, the compression strength, intensity strength, and curving strength was similar to that of concrete that uses normal rubble. Therefore, concrete beam made with broken red brick can be applied to the real construction field. Also, the study regarding the cutting test of the concrete that uses broken red brick and regarding applying and mixing admixture that can increase the ductility factor will be required in the future.

The Neutralization Treatment of Waste Mortar and Recycled Aggregate by Using the scCO2-Water-Aggregate Reaction (초임계이산화탄소-물-골재 반응을 이용한 폐모르타르와 순환골재의 중성화 처리)

  • Kim, Taehyoung;Lee, Jinkyun;Chung, Chul-woo;Kim, Jihyun;Lee, Minhee;Kim, Seon-ok
    • Economic and Environmental Geology
    • /
    • v.51 no.4
    • /
    • pp.359-370
    • /
    • 2018
  • The batch and column experiments were performed to overcome the limitation of the neutralization process using the $scCO_2$-water-recycled aggregate, reducing its treatment time to 3 hour. The waste cement mortar and two kinds of recycled aggregate were used for the experiment. In the extraction batch experiment, three different types of waste mortar were reacted with water and $scCO_2$ for 1 ~ 24 hour and the pH of extracted solution from the treated waste mortar was measured to determine the minimum reaction time maintaining below 9.8 of pH. The continuous column experiment was also performed to identify the pH reduction effect of the neutralization process for the massive recycled aggregate, considering the non-equilibrium reaction in the field. Thirty five gram of waste mortar was mixed with 70 mL of distilled water in a high pressurized stainless steel cell at 100 bar and $50^{\circ}C$ for 1 ~ 24 hour as the neutralization process. The dried waste mortar was mixed with water at 150 rpm for 10 min. and the pH of water was measured for 15 days. The XRD and TG/DTA analyses for the waste mortar before and after the reaction were performed to identify the mineralogical change during the neutralization process. The acryl column (16 cm in diameter, 1 m in length) was packed with 3 hour treated (or untreated) recycled aggregate and 220 liter of distilled water was flushed down into the column. The pH and $Ca^{2+}$ concentration of the effluent from the column were measured at the certain time interval. The pH of extracted water from 3 hour treated waste mortar (10 ~ 13 mm in diameter) maintained below 9.8 (the legal limit). From XRD and TG/DTA analyses, the amount of portlandite in the waste mortar decreased after the neutralization process but the calcite was created as the secondary mineral. From the column experiment, the pH of the effluent from the column packed with 3 hour treated recycled aggregate kept below 9.8 regardless of their sizes, identifying that the recycled aggregate with 3 hour $scCO_2$ treatment can be reused in real construction sites.

Shear Performance of Full-Scale Recycled Fine Aggregate Concrete Beams without Shear Reinforcement (전단 보강되지 않은 실규모 순환 잔골재 콘크리트 보의 전단성능)

  • Lee, Young-Oh;Yun, Hyun-Do
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.3
    • /
    • pp.225-232
    • /
    • 2012
  • This paper presents the test results on the shear performance of large-size reinforced concrete beams using recycled fine aggregate to evaluate its applicability to structural concrete. The performance of these beams is compared to that of similar beams casted with natural coarse and fine aggregates. All of the beam specimens without shear reinforcement had $400mm{\times}600mm$ rectangular cross section and a shear span ratio (a/d) of 5.0. Five concrete mixtures with different replacement levels of recycled fine aggregates (0, 30, 60, 70 and 100%) were used to obtain a nominal concrete compressive strength of 28MPa. The test results of load-deflection curve, shear deformation, diagonal cracking load, crack pattern, ultimate shear strength, and failure mode are examined and compared. In addition, code and empirical equations from KCI, JSCE, CSA, Zsutty, and MCFT were considered to evaluate the applicability of these equations for predicting shear strength of reinforced concrete beam with recycled fine aggregate. The results showed that the overall shear behavior of reinforced concrete beams incorporating less than 60% recycled fine aggregate was comparable with that of conventional concrete beam. The MCFT gave good prediction and other code equations were conservative in predicting the shear strength of the tested beams. The beam specimens with replacement of 70 and 100% of natural fine aggregates by recycled fine aggregates showed different failure mode than other tested beams.

A Study on the Hydration Property of Mortar with Balst Furnace Slag using Water Eluted from Recycled Coarse Aggregates (순환골재 용출수를 활용한 고로슬래그 미분말 혼입 모르터의 강도특성)

  • Shin, Sang-Yeop;Jeong, Euy-Chang;Kim, Young-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.81-82
    • /
    • 2012
  • The purpose of this study is the hydration properties of motar using Blast-Furnace Slag(BFS) with water elured from recycled coarse aggregate. The results of the experiment show that the water eluted from recycled coarse aggregate mixed with blast furnace slag has comparatively higher hydration activity than the mortar not mixed with one in early-age mortar causing the calcium hydroxide in the recycled coarse aggregate to work on as a stimulus to the hydration of ground granulated blast furnace slag. BFS mixed with the eluting water the hydration reaction was a promotion.

  • PDF