• Title/Summary/Keyword: 굴절도 변화량

Search Result 96, Processing Time 0.025 seconds

Dielectric Characteristics of Different Filler Content in Pb-free White Dielectric Layer (Pb-free 백색유전체에서 filler함량에 따른 유전체 특성)

  • An, Yong-Tae;Choi, Byung-Hyun;Lee, Jung-Min;Jee, Mi-Jung;Kim, Hyung-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.36-36
    • /
    • 2007
  • $R_2O_3$(R=Bi, B)-RO(R=Ba, Zn)를 주성분으로 하는 Pb-free유리프리트에 높은 굴절률을 가지고 있는 $TiO_2$ filler를 첨가하여 PDP용 백색유전체를 제조하였다. $TiO_2$ type, 함량에 따른 백색유전체로의 반사율 및 유전 특성을 조사하였다. 백색유전체를 소성한 결과 rutile과 anatase를 중량비로 75:25로 혼합하여 $520^{\circ}C$에서 소성한 경우 밀도 및 수축율의 변화를 거의 나타나지 않았다. 그러나 $TiO_2$함량이 15wt.%를 혼합하여 첨가했을 경우 반사율은 높고 접합특성 또한 우수하였다. 또한, 유전상수는 $TiO_2$첨가량이 증가함에 따라 증가하는 경향을 나타내었다.

  • PDF

Properties of ultra-thin silicon oxynitride films using plasma-assisted oxynitridation method (플라즈마 처리 기법을 이용한 초박형 실리콘 옥시나이트라이드 박막의 특성)

  • Jung, Sung-Wook;Yi, Jun-Sin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.260-260
    • /
    • 2009
  • 초박형 절연막은 현재 다양한 전자소자의 제작과 향상을 위하여 활용되고 있으며, 일반적인 화학 기상 증착 방법으로는 균일도를 확보하기 어려운 문제점을 가지고 있다. 본 논문에서는 디스플레이의 구동소자로 활용되는 박막 트랜지스터의 특성 향상과 비휘발성 메모리 소자의 터널링 박막에 응용하기 위하여 초박형 실리콘 옥시나이트라이드 박막의 증착과 이의 특성을 분석하였다. 실리콘 옥시나이트라이드 박막은 실리콘 산화막에 질소가 주입되어 있는 형태로 실리콘 산화막과 실리콘 계면상에 존재하는 질소는 터널링 전류와 결함 형성을 감소시키며, bulk 내에 존재하는 질소는 단일 실리콘 산화막에 비해 더 두꺼운 박막을 커패시턴스의 감소없이 이용할 수 있는 장점이 있다. 플라즈마 처리 기법을 이용하였을 경우에는 초박형의 균일한 박막을 얻을 수 있으며, 본 연구에서는 이산화질소 플라즈마를 이용하여 활성화된 질소 및 산소 라디칼들이 실리콘 계면을 개질하여 초박형 실리콘 옥시나이트라이드 박막을 형성활 수 있다. 플라즈마 처리 시간과 RF power의 변화에 따라 형성된 실리콘 옥시나이트라이드 박막의 두께 및 광학적 특성은 엘립소미터를 통하여 분석하였으며, 전기적인 특성은 금속-절연막-실리콘의 MIS 구조를 형성하여 커패시턴스-전압 곡선과 전류-전압 곡선을 사용하여 평가하였다. 이산화질소 플라즈마 처리 방법을 사용한 실리콘 옥시나이트라이드 박막을 log-log 스케일로 시간과 박막 두께의 함수로 전환해보면 선형적인 증가를 나타내며, 이는 초기적으로 증착률이 높고 시간이 지남에 따라 두께 증가가 포화상태에 도달함을 확인할 수 있다. 실리콘 옥시나이트라이드 박막은 초기적으로 산소의 함유량이 많은 형태의 박막으로 구성되며, 시간의 증가에 따라서 질소의 함유량이 증가하여 굴절률이 높고 더욱 치밀한 형태의 박막이 형성되었으며, 이는 시간의 증가에 따라 플라즈마 챔버 내에 존재하는 활성종들은 실리콘 박막의 개질을 통한 실리콘 옥시나이트라이드 박막의 두께 증가에 기여하기 보다는 형성된 박막의 내부적인 성분 변화에 기여하게 된다. 이산화질소 플라즈마 처리 시간의 변화에 따라 형성된 박막의 정기적인 특성의 경우, 2.3 nm 이상의 실리콘 옥시나이트라이드 박막을 가진 MIS 구조에서 accumulation과 inversion의 특성이 명확하게 나타남을 확인할 수 있다. 아산화질소 플라즈마 처리 시간이 짧은 실리콘 옥시나이트라이드 박막의 경우 전압의 변화에 따라 공핍영역에서의 기울기가 현저히 감소하며 이는 플라즈마에 의한 계면 손상으로 계면결합 전하량이 증가에 기인한 것으로 판단된다. 또한, 전류-전압 곡선을 활용하여 측정한 터널링 메카니즘은 2.3 nm 이하의 두께를 가진 실리콘 옥시나이트라이드 박막은 직접 터널링이 주도하며, 2.7 nm 이상의 두께를 가진 실리콘 옥시나이트라이드 박막은 F-N 터널링이 주도하고 있음을 확인할 수 있다. 즉, 2.5 nm 두께를 경계로 하여 실리콘 옥시나이트라이드 박막의 터널링 메카니즘이 변화함을 확인할 수 있다. 결론적으로 2.3 nm 이상의 두께를 가진 실리콘 옥시나이트라이드 박막에서 전기적인 안정성을 확보할수 있어 박막트랜지스터의 절연막으로 활용이 가능하며 2.5 nm 두께를 경계로 터널링 메커니즘이 변화하는 특성을 이용하여 비휘발성 메모리 소자 제작시 전하 주입 및 기억 유지 특성을 확보를 위한 실리콘 옥시나이트라이드 터널링 박막을 효과적으로 선택하여 활용할 수 있다.

  • PDF

Expectation of Astigmatism by Spherical Equivalent Visual Acuity (등가구면 시력으로부터 난시량의 예측)

  • Kim, Sang-Yoeb;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.167-170
    • /
    • 2011
  • Purpose: This study was tried whether expectation of astigmatism from spherical equivalent visual acuity was possible. Methods: For 54 men and women (108 eyes) corrected to emmetropia, average age of 23.3, changes of visual acuity (5m) were measured with an increasing the powers at every ${\pm}$0.25D when the (-) axis of cross cylinder is $180^{\circ}$, $90^{\circ}$, and $45^{\circ}$, respectively. Results: As the power of cross cylinder was increased, visual acuity was decreased. When the powers of cross cylinder were ${\pm}$2.50D ($180^{\circ}$ and $90^{\circ}$) and ${\pm}$2.25D ($45^{\circ}$), visual acuity was 0.05 which is the minimum measurement possible. Conclusions: The diagram on astigmatism dealing with each spherical equivalent visual acuity was able to tabulate.

Characteristics of Diamond Like Carbon Film Fabricated by Plasma Enhanced Chemical Vapor Deposition Method with mixed Ar, N2 gas rate (혼합된 Ar, N2 가스 유량에 따른 PECVD 방법에 의하여 제작된 다이아몬드 상 탄소 박막의 특성)

  • Gang, Seong-Ho;Kim, Byeong-Jin;Bae, Gyeong-Tae;Ju, Seong-Hu
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.87-87
    • /
    • 2018
  • 다이아몬드 상 탄소(diamond-like carbon, DLC)는 상당량의 $sp^3$ 결합을 가지는 비정질 탄소(a-C) 또는 수소화 비정질 탄소(a-C:H)로 이루어진 준안정 형태의 탄소이다. DLC는 전기 저항과 굴절률이 높고 화학적으로 다른 물질과 반응하지 않으며, 마찰계수가 낮고 경도가 높아 자기 디스크, 광학 소자 등의 다양한 분야에서 적용되고 있다[1,2]. 또한 다이아몬드에 비해 상온에서 성장이 가능할 정도로 합성온도가 낮아 적용 기판의 제한이 거의 없고, 증착 방법과 조건에 따라 탄소 결합의 다양성과 비정질성이 변화하기 때문에 넓은 범위의 특성을 얻을 수 있는 장점이 있다. 지금까지 DLC 박막의 광학적 특성, 특히 굴절률, 광학적인 에너지 밴드 갭, 자외선과 적외선 투과성에 대해서는 많은 연구가 진행되었으나 가시광선의 투과성에 대한 연구는 제한적이며[4], 가시광선 투과도 개선에 대한 연구는 전무하다. 본 연구에서는 ITO 기판 위에 DLC를 합성하고 기계적 특성과 가시광선 영역 투과도를 조사하였다. RF-PECVD(radio frequency plasma enhanced chemical vapor deposition) 방법에 의해서 $C_2H_2+Ar$ 혼합 가스 비율과 $C_2H_2+N_2$ 혼합 가스 비율을 변화시켜 ITO 기판 위에 DLC 박막을 합성하였다. 공정 압력과 rf-power, 증착시간, 기판온도는 0.2 torr, 40 W, 5 분, $50^{\circ}C$로 고정하고, 공정 가스는 $C_2H_2+Ar$$C_2H_2+N_2$가 200 sccm이 되도록 비율을 변화하였다. $C_2H_2:Ar$$C_2H_2:N_2$의 비율은 180 : 20, 160 : 40, 140 : 60, 120 : 80, 100 : 100이 되도록 가스의 유량을 조절하였다. 투과도는 가시광선(380 ~ 780 nm) 범위에서 측정하였고 두께와 표면조도는 AFM으로 측정하였다. 투과도는 $C_2H_2+Ar$의 Ar 가스 비율이 증가할수록 증가해 140 : 60일 때 최댓값을 나타낸 후 다시 감소하였다. $C_2H_2+N_2$ 투과도는 $N_2$ 가스 비율이 증가할수록 감소하는 경향을 나타내었다. 표면 거칠기는 $C_2H_2+Ar$ 혼합 가스를 사용한 경우의 Ar의 가스 비율이 증가할수록 증가하였다. 그러나 $C_2H_2+N_2$ 혼합 가스를 사용한 경우에는 $N_2$ 가스의 혼합 비율이 증가할수록 감소하였다.

  • PDF

Physicochemical Changes in Pork Boston Butts by Different Cooking Methods (가열조리방법에 따른 돼지고기 목심의 이화학적 특성 변화)

  • Yang, Jong-Beom;Ko, Myung-Soo
    • Food Science and Preservation
    • /
    • v.17 no.3
    • /
    • pp.351-357
    • /
    • 2010
  • To decrease the intake of animal fat and cholesterol, changes in the physico-chemical characteristics of pork Boston butts cooked by different methods (boiling, steaming, baking, and frying) were investigated. Cooking weight loss and the drain rates of moisture, lipids, and cholesterol were highest during frying. The pH value increased during all cooking processes tested. The refractive index of meat fat increased markedly upon frying. The hardness, gumminess, and chewiness of meat were notably increased by frying. Springiness was not significantly affected by any cooking process, and cohesiveness was slightly increased by all cooking methods evaluated. The CIE $L^*$ (lightness) value was markedly increased upon steaming, and the CIE $a^*$ (redness) value decreased notably with boiling or steaming. The CIE $b^*$ (yellowness) value decreased slightly with either boiling or steaming, and was slightly increased when baking or frying was used. The fatty acid composition did not significantly change after cooking, except when meat was fried.

Characteristics of fiber-optic current sensors using perpendicular coil formers (수직원형틀을 이용한 광섬유전류센서의 동작특성)

  • 이명래;이용희;김만식
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.419-427
    • /
    • 1996
  • Thermally-stabilized fiber-optic current sensors are proposed and demonstrated. The sensor head is made of two coil formers combined perpendicularly. In this sensor head, bending-induced birefringences can be reduced to the level much smaller than those of the single former type because the eigen-axes of the two perpendicular coil formers are made orthogonal to each other. Moreover, thermal variation of the birefringence is also expected to be minimized by the orthogonality of the two polarization eigen-axes. We changed the temperature slowly in the range of 20~45$^{\circ}C$ during 100 minutes. The overall linearity of the sensor is better than 1.2% in the range of 0~1000A. The long-term fluctuation of the sensor is less than 1% when measured for 3 hours at 500A and room temperature. Two orthogonally-polarized laser diodes are combined together to make the incident beam unpolarized. In the signal processing, the signals are separated by two parts and normalized respectively, which minimize the efects of optical fluctuations coming from sources, connectors, etc.

  • PDF

A Study on Alkali ion-Sensitivity of $Si_{x}O_{y}N_{z}$ Fabricated by Low Pressure Chemical Vapor Deposition (저압화학기상 성장법으로 제작된 $Si_{x}O_{y}N_{z}$의 알칼리이온 감지성에 관한 연구)

  • Shin, P.K.;Lee, D.C.
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.200-206
    • /
    • 1997
  • Using $SiCl_{2}H_{2}$, $NH_{3}$ and $N_{2}O$, we have fabricated silicon oxynitride ($Si_{x}O_{y}N_{z}$) layers on thermally oxidized silicon wafer by low pressure chemical vapor deposition. Three different compositions were achieved by controlling gas flow ratios($NH_{3}/N_{2}O$)) to 0.2, 0.5 and 2 with fixed gas flow of $SiCl_{2}H_{2}$. Ellipsometry and high frequency capacitance-voltage(HFCV) measurements were adapted to investigate the difference of the refractive index, dielectric constant, and composition, respectively. Regardless of nitride content, silicon oxynitrides had similar stability to silicon nitrides. The relative standing of alkali ion sensitivity in silicon oxynitride layers was influenced by nitride content. The better alkali ion-sensitivity was achieved by increasing oxide content in bulk of silicon oxynitrides.

  • PDF

Measurement of the Nonlinear Optical Properties by use of the Far-Field Phase Modulation Method (Far-field 위상 변조량 측정법을 이용한 광학매질의 비선형 특성 측정)

  • 김성훈;양준목;김용평;이영우;신동주;정영붕
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.3
    • /
    • pp.168-174
    • /
    • 1998
  • We have measured nonlinear refractive index and nonlinear absorption coefficient of optical materials by using a far-field phase modulation technique. The phase variation of the probe beam in the nonlinear material is transformed into the spatial phase modulation in the far-field so that the spatial distribution of the optical intensity in conjunction with the computer simulation analysis can give the nonlinear optical constants. We have obtained the nonlinear refractive indices and nonlinear absorption coefficient of $CS_2$ and $BaF_2$ by fitting the experimental values and numerical simulation analysis of far-field measurements. The nonlinear refractive indices of $CS_2$ and $BaF_2$were obtained as $1.2{\times}10^{-11}$ esu and $1.0{\times}10^{-13}$ esu, respectively at 616 nm, and the nonlinear absorption coefficient of BaF$_2$as $5.0{\times}10^{-11}$cm/W at 308nm. These measured values were in good agreement with previous reports.

  • PDF

표준기용 Spectroscopic Ellipsometer 제작

  • 조용재;조현모;김현종;신동주;이윤우;이인원
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.38-39
    • /
    • 2002
  • Spectroscopic ellipsometer(SE)는 박막의 두께, 굴절률, 흡수율, 에너지 갭, 결정상태, 밀도, 표면 및 계면의 거칠기 등에 관한 유용한 정보들을 제공한다. (1-3) SE는 빛을 탐침으로 사용하기 때문에 비파괴적이고 비접촉식 박막물성 측정방법이며 편광변화에 대한 상대적 물리량을 측정함으로써 정밀도와 재연성이 매우 높은 장점들을 갖고 있다. 따라서 SE는 반도체 메모리 소자, 평판 디스플레이, DVD와 CD와 같은 데이터 저장장치 등을 제작하는 공정에서 박막에 관련된 공정계측장비로 사용되고 있다. 특히, 최근의 차세대 반도체 소자 개발에 관한 연구 등(4-6)에서는 수 nm 두께의 다양한 초박막들에 관한 물성연구가 주관심사이기 때문에 최고의 성능을 갖는 계측장비와 기술이 요구되고 있다. 따라서 본 연구에서는 그림과 같은 편광자(polarizer)-시료(sample)-검광자(analyzer)로 구성된 PSA구조의 표준기용 rotating-analyzer SE를 제작하게 되었다. 현재까지 개발된 ellipsometer의 수많은 종류들 중에서 null 형, rotating element 형, 그리고 phase modulation 형이 가장 많이 사용되고 있다. 여기서 element란 polarizer, analyzer, 또는 compensator와 같은 광 부품들을 지칭하는데 이 중 하나 또는 둘을 회전시키기 때문에 그 종류 또한 매우 많다. 이들 중에서 회전검광자형 ellipsometer는 입사각 정렬이 우수하고, 파장에 무관한 편광기만 사용하므로 비교적 넓은 광량자 에너지영역에서 정확도 높은 데이터를 얻을 수 있기 때문에 박막 상수의 정밀측정에 가장 적합하다. 특히, 본 연구에서 제작된 ellipsometer에는 간섭계 장치, polarizer tracking,(2) zone average,(1) 그리고 low-pass filter 등을 사용함으로써 측정오차를 최대한 줄이는 노력을 하였다.

  • PDF

Study on the Construction of Optical Hydrometer (광학식 비중계 제작에 관한 연구)

  • Euijin Hwang;Jinuk Lee;Myungsoo Kim
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.3
    • /
    • pp.442-445
    • /
    • 1992
  • Optical type hydrometer has been designed and constructed utilizing the fact that the refractive index of solution is varied in accordance with its specific gravity. Optical hydrometer produces the electric singal output with reflection of light in accordance with its specific gravity. This can be applied to continuous monitoring and/or automatic control of the specific gravity of solution. U-shaped glass rod was used a transfer medium of light, and the electronic circuit which utilize phase sensitive detection technique was designed to measure accurately the intensity of light. The specific gravity of sulfuric acid was measured with this hydrometer and the results show good linearity of output signal with its specific gravity.

  • PDF