• Title/Summary/Keyword: 굴곡 각

Search Result 242, Processing Time 0.021 seconds

Influence of the Lumbar Spine Adjustment using the Lumbar Roll Support on Head and Neck Posture in Older Adults (요추 지지대에 의한 노인의 요추만곡 조절이 머리와 목 자세에 미치는 영향)

  • Ko, Seung-Hyun;Kim, Yu-Shin;Yoon, Bum-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.12
    • /
    • pp.800-806
    • /
    • 2011
  • The objective of this study was to identify the effect of lumbar lordotic curve adjustment on head and neck posture in older adults. Methods Twenty healthy older participants (mean age 71.32) were photographed while watching monitor in sitting with or without lumbar roll support(length 28cm, diameter 10cm). The upper cervical angle and lower cervical angle were measured using the NIH ImageJ 1.32. Comparisons between upper and lower cervical angle with or without lumbar roll support were made using paired-t test analysis. Results Subjects demonstrated a significant difference in the mean upper and lower cervical angle. Mean difference of the upper cervical angle was about $2.83^{\circ}$ with and without lumbar roll support(p<0.005). Mean difference of the lower cervical angle was about $4.44^{\circ}$ with and without lumbar roll support(p<0.0001). Conclusions This study showed that healthy older adults demonstrated more ability to maintain an upright posture of cervical spine during lumbar lordotic curve maintenance with lumbar roll support than without lumbar roll support. When the clinicians consider improvement of the head and neck posture in older adults, they must incorporate adjustment in the lumbar region.

Study on Flexural Properties of Polyamide 12 according to Temperature produced by Selective Laser Sintering (선택적 레이저 소결 제작 폴리아미드 12 시편의 온도별 굴곡 특성 연구)

  • Kim, Moosun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.319-325
    • /
    • 2018
  • The use of 3D printing (Additive Manufacturing) technology has expanded from initial model production to the mass production of parts in the industrial field based on the continuous research and development of materials and process technology. As a representative polymer material for 3D printing, the polyamide-based material, which is one of the high-strength engineering plastics, is used mainly for manufacturing parts for automobiles because of its light weight and durability. In this study, the specimens were fabricated using Selective Laser Sintering, which has excellent mechanical properties, and the flexural characteristics were analyzed according to the temperature of the two types of polyamide 12 and glass bead reinforced PA12 materials. The test specimens were prepared in the directions of $0^{\circ}$, $45^{\circ}$, and $90^{\circ}$ based on the work platform, and then subjected to a flexural test in three test temperature environments of $-25^{\circ}C$, $25^{\circ}C$, and $60^{\circ}C$. As a result, PA12 had the maximum flexural strength in the direction of $90^{\circ}$ at $-25^{\circ}C$ and $0^{\circ}$ at $25^{\circ}C$ and $60^{\circ}C$. The glass bead-reinforced PA12 exhibited maximum flexural strength values at all test temperatures in the $0^{\circ}$ fabrication direction. The tendency of the flexural strength changes of the two materials was different due to the influence of the plane direction of the lamination layer depending on the type of stress generated in the bending test.

Effects of induced stereoacuity reduction on obstacle crossing (입체시력 감소가 장애물 보행에 미치는 영향)

  • Woo, Byung-Hoon;Sul, Jeong-Dug
    • 한국체육학회지인문사회과학편
    • /
    • v.54 no.5
    • /
    • pp.829-840
    • /
    • 2015
  • The purpose of this study was to investigated into the kinematics and ground reaction force for gait on induced stereoacuity in normal subjects with normal sight. Eighteen subjects who passed the stereoacuity testing were participated in the experiment(age: 22.1±2.7 years, height: 176.8±4.4 cm, weight: 67.6±5.8 kg). The study method adopted 3D analysis with six cameras and ground reaction force with two force-plates. The results were as follows; In gait velocity, obstacle crossing gait was slower than flat gait. In angular displacement of hip joint, mostly obstacle crossing gait was more flexed than flat gait. In angular displacement of knee joint, obstacle crossing gait was more flexed than flat gait, and stereoacuity reduction gait in TO and FC2 were more flexed than normal vision gait. In angular displacement of ankle joint, obstacle crossing gait in FC2 was more flexed than flat gait. In trunk tilt, obstacle crossing gait in MSt, TO and MSw were more extended than flat gait. In GRF, there was no significant in Fx, obstacle crossing gait in right and left foot were bigger propulsion force than flat gait, obstacle crossing gait in right and left foot were bigger braking force than normal vision gait in Fy, and obstacle crossing gait in right and left foot were bigger than flat gait in peak F1 and peak F2 of Fz, and stereoacuity reduction gait in right foot was lower than normal vision gait in valley force of Fz.

Mechanical Properties of Talc-Filled Polypropylene : Coupling Agent Effect (Talc로 충전된 폴리프로필렌의 기계적 물성 : 커플링제 효과)

  • 김주성;최미애;박태욱;김덕준
    • Polymer(Korea)
    • /
    • v.24 no.6
    • /
    • pp.770-776
    • /
    • 2000
  • The effect of unreactive coupling agent on mechanical and thermal properties of talc-filled polypropylene (PP) composites was studied. Stearic and oleic acids were introduced as coupling agents, and tensile, flexural, and impact strength, thermal stability and melting transition temperature were measured and analyzed according to the types and concentration of coupling agents. Tensile and flexural strength were enhanced by introduction of coupling agent and the maximum effect was observed at the concentration of 3 wt% of coupling agent. Tensile and flexural strength of PP treated with oleic acid were higher than those of PP treated with stearic acid. but impact strength vice-versa. The reasons for these results were postulated by analyzing morphologies of talc-filled PP observed by SEM.

  • PDF

The Design and Implementation of the Explorer Robot Adaptive Pipe Magnitude Width and Curve (파이프 크기와 굴곡에 적응하는 탐사로봇 설계 및 구현)

  • Lee, Kwang-Seok;Lee, Byeong-Ro;Choo, Yeon-Gyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.3
    • /
    • pp.602-607
    • /
    • 2009
  • Most of explorer robot in past has the fixed magnitude and communicate with wire communication method. In case of various range of pipe's width and various angle in pipe inter structure, the exploring work is very difficult. Thus, in this paper, we design as dealing with spring tension with pushing out pipe exterior, and applied RF communication. We can accept good performance both structure change and improvement of ability, monitor and collect the defaults data in pipe inter structure. Newly designed and developed pipe explorer robot is very advantageous to carrying and driving as being small and law weight.

Alterations in the Neuro-Mechanical Properties of Human Ankle Dorsiflexor after Maximum Eccentric Exercise (최대 신장성 수축운동에 따른 인체 하지 족배굴곡근의 신경-기계학적 특성 변화)

  • Lee, Hae-Dong;Kim, Seung-Jae;Kawakami, Yasuo
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.4
    • /
    • pp.21-30
    • /
    • 2008
  • The purpose of this study was to investigate changes in mechanical properties of human tibialis anterior following eccentric exercise. Healthy subjects (n=12) performed 120 maximum eccentric contraction of ankle dorsiflexor. Before and 1- and 24- hour after the eccentric exercise, ankle dorsiflexion moment-angle relationships were obtained. Along with significant decrease in maximum isometric muscle strength, the shift of the optimum ankle joint angle toward the longer muscle length direction was observed, independent of the ranges of motion of the eccentric exercise. The results of this study demonstrated that eccentric exercise-induced micro muscle damage(Morgan & Allen, 1999) does rut seem to be a sole mechanism of eccentric contraction-induced muscle damage, suggesting further investigation for the better understandings of this phenomenon.

The Temporal Coordination of the Lower Extremity by Increasing High-heel Height during Walking (보행 시 하이힐 굽 높이 증가에 따른 하지의 시간 협응성)

  • Ryu, Ji-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.3
    • /
    • pp.593-601
    • /
    • 2009
  • The goal of this study was to investigate the lower extremity's coordination determined by temporal relations with increasing high-heel (3, 7, 9cm) while walking on a treadmill. Twelve healthy women who walked on a treadmill under three conditionswearing 3cm high-heel shoes, 7cm, and 9cm-while kinematic data were collected using a six-cameras (240Hz) Qualisys ProReflex System. From these data, knee flexion, tibia internal rotation, and foot eversion were calculated in Euler technique and found the time for occurring the maximum angle of these movements. The maximum angle of these movements occurred almost simultaneously in 3cm high-heel walking, but not in 7cm and 9cm. The ratio of time for maximum angle of the foot eversion to tibia internal rotation converged to 1 in 3cm high-heel walking, but were less than 1 in 7cm and 9cm. In conclusion, it was indicated that 3cm high-heel walking had better the lower extremity's coordination compared with 7, 9cm high-heel walking.

Strength Evaluation of Sin91e-Radius Total Knee Replacement (TKR) (인공무릎관절의 단축법위 회전시 근력정가)

  • Wan, Jin-Young;Sub, Kwak-Yi
    • Journal of Life Science
    • /
    • v.14 no.3
    • /
    • pp.484-489
    • /
    • 2004
  • Artificial joint replacement is one of the major surgical advances of the 21th century. The primary purpose of a TKA (Total Knee Arthroplasty) is to restore normal knee Auction. Therefore, ideally, a TKA should: (a) maintain the natural leverage of the knee joint muscles to ensure generating adequate knee muscle moments to accomplish daily tasks such as rising from a chair or climbing stairs;(b) allow the same range of motion as an complete knee; and (c) provide adequate knee joint stability. Four individuals (2 peoples after surgery one year and 2 peoples after surgery three years) participated in this study. All they were prescreened for health and functional status by the same surgeon who performed the operations. Two days of accommodation practice occurred prior to the actual strength testing. The isometric strength (KIN-COM III) of the quadriceps and hamstring were measured at 60$^\circ$ and 30$^\circ$ of knee flexion, respectively. During isokinetic concentric testing, the range of motion was between 10$^\circ$ to 80$^\circ$ of knee flexion (stand-to-sit) and extension (sit-to-stand). for a given test, the trial exhibiting maximum torque was analyzed. A 16-channel MYOPACTM EMG system (Run Technologies, Inc.) was used to collect the differential input surface electromyographic (EMG) signals of the vastus medialis (VM), vastus lateralis(VL), rectus femoris (RF) during sit-to-stand and stand-to-sit tests. Disposable electrodes (Blue SensorTM, Medicotest, Inc.) were used to collect the EMG signals. The results were as follows; 1. Less maximum concentric (16% and 21% less for 1 yew man and 3 years mm, respectively) and isometric (12% and 29%, respectively) quadriceps torque for both participants. 2.14% less maximum hamstrings concentric torque for 1 year man but 16% greater torque for 3 years mm. However, 1 year man had similar hamstring isometric peak torque for both knees. 3. Less quadriceps co-contraction by 1 year man except for the VM at 10$^\circ$-20$^\circ$ and 30$^\circ$-50$^\circ$ range of knee flexion.

Hip Range of Motion Estimation using CT-derived 3D Models (CT기반 3차원 모델을 이용한 고관절 운동범위 예측)

  • Lee, Yeon Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.115-122
    • /
    • 2018
  • The success of the total hip arthroplasty is revealed as initial stability, range of motion, and long term pain, etc. Depending upon choice of implantation options such as femoral neck offset, diameter of the femoral head, the lateral opening tilt. Especially the impingement between femoral head component and acetabular cup limits the range of motion of the hip. In this sense, estimation or evaluation of the range of motion before and after the total hip arthroplasty is important. This study provides the details of a computer simulation technique for the hip range of motion of intact hip as well as arthroplasty. The suggested method defines the hip rotation center and rotation axes for flexion and abduction, respectively. The simulation uses CT-based reconstructed 3D models and an STL treating software. The abduction angle of the hip is defined as the superolateral rotation angle from sagittal plane. The flexion angle of the hip is defined as the superoanterior angle from the coronal plane. The maximum abduction angle is found as the maximum rotation angle by which the femoral head can rotate superolaterally about the anterior-posterior axis without impingement. The maximum flexion angle is found as the maximum rotation angle by which the femoral head can rotate superoanteriorly about the medial-lateral axis without impingement. Compared to the normal hip, the total hip replacement hip showed decreased abduction by 60 degrees and decreased flexion by 4 degrees. This measured value implies that the proposed measurement technique can make surgeons find a modification of increase in the femoral neck offset or femoral head, to secure larger range of motion.

Development of the environmental protection machine for upland-crop production (밭 농업 제초기 개발을 위한 기초설계)

  • Kim, T.W.;Lee, H.J.;LEE, S.H.;KIM, J.H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.82-82
    • /
    • 2017
  • 현대농업에서 잡초를 조기에 제거하지 못할 경우 작물의 성장에 장애를 초래하므로 제초작업은 매우 중요하다. 최근 친환경 고품질 농산물에 대한 소비자의 관심과 고품질 농산물에 대한 가격 차별화 등으로 제초제를 사용하지 않은 친환경 재배가 주목을 받고 있다. 제초제는 농작물에 따라 분류가 되어있어 종류마다 효과가 다르고 사용방법이 종류에 따라 어떻게 사용되는지 알기가 쉽지 않아 이에 따른 피해 또한 무시 할 수 없다. 현재 상용화되어 있는 제초기는 굴곡이 있는 고랑의 잡초를 효율적으로 제거하기 어려워 밭작물 제초작업에 사용하기 부적합하다. 밭작물 재배 기간에 행해지는 고랑의 제초작업은 평지보다 더 많은 힘이 필요하고 일반적인 제초기로는 좋은 결과를 얻기 어렵다. 또한 제초 작업시 농작물 피해와 멀칭 비닐을 손상시키는 문제가 발생 하고 있다. 따라서 밭작물에 효율적인 잡초를 제거하기 위해 굴곡이 있는 지형의 잡초를 제거하기 위한 제초기 개발이 반드시 필요하다. 밭작물용 제초기를 개발하기 위해 굴곡이 있는 고랑의 잡초 제거가 가능한 제초날의 형상 설계가 우선되어야 하며, 고랑의 잡초제거를 위한 제초날 형상설계를 하기 위해 우리나라 주요 밭작물 재배지의 이랑 넓이, 고랑 깊이 및 고랑 폭을 조사 분석하였다. 조사 작물 대상은 양파, 마늘, 무, 배추, 고추, 당근, 감자 총 7가지 작물을 대상으로 조사하였으며, 각 작물들의 이랑 넓이와 고랑 깊이 및 폭의 평균치를 구하여 제초날 설계에 적용하고자 하였다. 범위가 있는 수치는 높은 수치를 기준으로 계산하였으며 고랑의 평균 폭은 34.2cm이고, 고랑의 평균 깊이는 22.1cm가 나타났다. 잡초를 효과적으로 제거하기 위해 제초날의 형상은 고랑의 크기 및 형태에 맞게 원형으로 설계를 하여야 한다. 형상 설계는 밭작물 고랑 평균직경 및 평균높이를 고려하고, 제초작업시 제초날이 작물 및 멀칭비닐의 손상 하지 않도록 하기 위해 직경은 고랑 평균 폭의 75% 정도 치수로 형상을 설계하고, 제초날 깊이는 고랑의 굴곡형태을 고려할 때 제초날 반경의 70%정도로 설계하여 원형제초날 폭 250mm, 제초날 깊이 87.5mm로 설계해야 할 것으로 분석 되었다.

  • PDF