• 제목/요약/키워드: 국소공기연령

검색결과 12건 처리시간 0.023초

국소평균공기연령을 이용한 국소환경시스템의 청정도 평가 및 예측 (Evaluation and Prediction of Cleanliness Level in the Mini-Environment System Using Local Mean Air-Age)

  • 노광철;이현철;박정일;오명도
    • 대한기계학회논문집B
    • /
    • 제31권5호
    • /
    • pp.457-466
    • /
    • 2007
  • A numerical and experimental study on the evaluation and the prediction of cleanliness level in the mini-environment system was carried out. Using the concept of local mean air-age (LMA) and effective flow rate, the new direct method for estimating the mini-environment was developed and compared with the previous performance index of airflow pattern characteristics. It was found out that the airflow pattern analysis is a restricted method to estimate the real performance of the mini-environment. The reason is that the airflow pattern cannot predict the effect of the increment of the ventilation rate on the cleanliness level in the mini-environment. While LMA is capable of showing the effects of the contaminant accumulation caused by turbulent intensity, eddy, and the increment of the effective flow rate. This result showed that LMA is more exact and effective performance index than the previous one like the airflow pattern characteristics.

전산실의 환기성능 최적화를 위한 연구 (A Study for Optimization the Ventilation Performance of the Computer Room)

  • 권용일
    • 설비공학논문집
    • /
    • 제27권2호
    • /
    • pp.57-62
    • /
    • 2015
  • The objective of the present study is to identify the ventilation problems and to suggest the optimal ventilation system to save energy and to improve IAQ in the computer rooms, which annually performs the cooling operation by the server with the highly thermal load. Numerical results on the temperature and local mean age are presented along with some of the discharge velocities. Results show many interesting aspects of airflow patterns affecting the ventilation performances, according to the discharge velocity of the supply diffuser installed in the bottom surfaces between the servers. As the results, 2.5 m/s of the optimal discharge velocity is needed in order to improve the ventilation performance.

벽체 매립형 환기용 팬 성능개선에 관한 연구 (Study on the Performance Improvement of Ventilation Fan Installed in Walls of Underground Parking Lots)

  • 권용일
    • 설비공학논문집
    • /
    • 제26권5호
    • /
    • pp.206-211
    • /
    • 2014
  • The objective of the present study was to identify ventilation problems, and also to suggest new axial fan systems for the improvement of IAQ in the underground parking lots. Numerical results for air mean-velocity, local mean age, and sound power level are presented along with some of fan angles. The results showed the influence of airflow patterns on the fan performances installed in the underground parking lots. Discharge air volume is increased with the angle of the blade. And also, the main factors affecting the noise of the ventilation fan was found to be a rotational speed.

냉방시 시스템에어컨과 환기유닛 적응 강의실에서 실내 $CO_2$ 농도와 국소평균공기연령 연구 (Study on the Relationship between Indoor $CO_2$ Concentration and Local Mean Air-age in the Lecture Room with System Air-conditioner and Ventilation Unit for Cooling Loads)

  • 장재수;노광철;오명도
    • 설비공학논문집
    • /
    • 제17권8호
    • /
    • pp.736-745
    • /
    • 2005
  • This study is undertaken to evaluate the relationship between the indoor $CO_2$ concentration and the local mean air-age in the lecture room with the occupants. We conducted the experiments to examine the indoor $CO_2$ concentration and the local mean air-age with respect to the supply airflow of the ventilation system and the discharge angle and air-flow of the system air conditioner. Through the experiments, we found out that indoor $CO_2$ concentrations calculated by the prediction equation of Seidel are about 350 ppm lower than those measured by the experiments. The indoor $CO_2$ concentration is not related with the air-flow and the discharge angle of the system air-conditioner, but with the ventilation airflow. From the numerical calculation, the indoor $CO_2$ concentration is not related with the ventilation effectiveness, but strongly with the local mean air-age. In case of our model, the indoor $CO_2$ concentration is likely to fall within the acceptable air quality when the local mean air-age is averagely predicted under 400 seconds.

저선량 흉부전산화단층촬영의 흡기 영상과 폐기능이 정상인 성인에서 호기 말 폐 감쇄도 증가 정도와 연령 및 흡연과의 연관성 (Correlation between Expiratory Increase of Lung Attenuation and Age and Smoking in the Subjects with Normal Inspiratory Low Dose CT and Pulmonary Function Test)

  • 권성연;황용일;윤호일;이재호;이춘택;이경원
    • Tuberculosis and Respiratory Diseases
    • /
    • 제65권6호
    • /
    • pp.457-463
    • /
    • 2008
  • 연구배경: 호기말에 흉부 촬영을 시행하면 폐 내의 공기의 부피가 감소되어 폐 감쇄도가 증가한다. 이런 폐 감쇄도의 변화가 국소적으로 저하되는 공기 가둠 현상에 대해서는 일부 연구들이 있었으나 전체 폐의 전반적인 감쇄도 변화에 대한 연구는 거의 없고, 특히 정상인을 대상으로 한 연구는 거의 없다. 저자들은 호흡기 질환이 없으며 폐기능 및 흡기 전산화단층촬영이 정상 소견이고 호기 영상에서 국소적인 공기 가둠 현상이 없는 100명을 대상으로 연구를 수행하였다. 방 법: 흉부 전산화단층촬영 영상에서 24개의 지점을 정하고, 흡기 및 호기 시 각 지점에서 폐 음영도를 측정한 후 호기말 폐 감쇄도 증가와 흡연량, 연령 사이의 상관 관계를 알아보았다. 결 과: 연구 대상 100명의 연령은 중앙값 49.0세(범위 25~71세)였고, 평균 흡연량은 $22.5{\pm}17.0$갑년이었다. 연령과 폐 감쇄도의 증가 사이에는 유의한 음의 상관관계가 있었으며 이는 흡연의 효과를 보정하였을 때에도 유지되었고, 연령을 기준으로 세 군으로 나누어 폐 감쇄도의 증가 정도를 비교하였을 때에도 유의한 차이가 있었다. 흡연량과 호기말 폐 감쇄도의 증가 사이에는 유의한 음의 상관관계가 관찰되었으나 연령을 보정하였을 때에는 유의성이 감소하였다. 결 론: 흡기-호기 시의 폐의 전반적인 감쇄도 변화 정도는 연령과 상관관계가 있으며, 노화를 반영할 가능성이 있다.

지하 수처리시설 유지관리층 환기설비의 성능평가 (Evaluation of the Ventilation Efficiency in an Underground Sewage Disposal Plant)

  • 강한기;이재헌
    • 설비공학논문집
    • /
    • 제19권10호
    • /
    • pp.695-702
    • /
    • 2007
  • In this paper, the ventilation efficiencies of an underground sewage disposal plant were investigated for ventilating system without fan, ventilating system with eleven cross flow fans and ventilating system with sixteen cross flow fans by numerical method. It has been found that the air change effectiveness of the system without fan was predicted 0.44. It means that an additional ventilating equipment is needed to maintain good indoor air quality. For the ventilating system with sixteen cross flow fans, the air change effectiveness was predicted 0.55. The air change effectiveness of the ventilating system with eleven cross flow fans was predicted 0.51. It is known that the air change effectiveness above 0.5 is enough to eliminate pollutant and bad smell in the indoor. Therefore, it is recommended to select the ventilating system with eleven cross flow fans for the underground sewage disposal plant in an economic point of view.

실증실험을 통한 측정 위치에 따른 주거공간 환기성능 평가 (Evaluation of Ventilation Performance of a Residential Unit for Different Sampling Points through Actual Field Tests)

  • 곽병창;이수만;김길태;김종엽
    • 토지주택연구
    • /
    • 제13권3호
    • /
    • pp.93-106
    • /
    • 2022
  • 일반적으로 실내 공기질을 조절하기 위해서는 환기의 역할이 중요하다. 최근 코로나-19 등 감염병의 확산으로 거주자들의 실내에서 보내는 시간이 늘어남에 따라 환기의 중요성은 더욱 높아지고 있으며, 환기성능에 대한 관심도 더욱 높아지는 추세이다. 많은 국가에서 현재 환기 성능을 파악하는 지표로서 시간당 환기횟수를 사용하고 있으며, 국내에서도 공동주택을 대상으로 시간당 0.5회 이상의 환기횟수를 확보하도록 규제하고 있다. 하지만, 선행연구 및 국내외 환기성능 평가 관련 표준을 검토한 결과 시간당 환기횟수만을 통해 실내 환기 성능을 평가하는데에는 실질적 실내 환기 성능을 평가하는 데에는 한계가 있는 것으로 나타났으며, 실질적인 환기 성능을 평가하기 위해서는 실내 국소부위를 대상으로 오염물질 저감속도와 공간내 환기 성능 균일도 등을 고려하는 것이 필요할 것이다. 이에 대해 본 연구에서는 추적가스 희석법을 이용한 실증 실험을 통해 측정 위치별 유속, 공기연령 및 환기효율을 측정하고 비교하였으며, 측정점별 조합에 따른 평균값과 공간 내 중심점에서의 측정값을 비교하여 측정점 선정에 따른 환기성능 차이를 비교 조사하였다. 본 연구 결과는 향후 실환경 기반의 주거공간 실내 환기성능을 평가하기 위한 실험절차 개발을 위한 기초자료로 활용될 수 있을 것이다.

태양일사가 실내공간의 열적 쾌적성과 환기성능에 미치는 영향에 관한 연구 (The study on the effect of the solar radiation on thermal comfort and ventilation performance in room space)

  • 연성현;이효준;리광훈
    • 한국가시화정보학회지
    • /
    • 제14권1호
    • /
    • pp.19-26
    • /
    • 2016
  • Modern people spend much time at indoor space. So, People want to make better indoor air condition. But the facade of building is made of glass to be seen urbanely, the effect of solar radiation makes indoor environment worse. This study designs an open space affected by solar radiation with 4-way cassette air-conditioner. Using numerical simulation, this paper investigates thermal comfort and ventilation performance with discharge angles $30^{\circ}$ and $45^{\circ}$. To study thermal comfort, this paper studies distribution of velocity, temperature and effective draft temperature. Also, this paper introduces concept of air age to study ventilation performance. The flow influenced by solar radiation determines thermal comfort and ventilation performance in room space. This study shows that discharge angle of 45 degree has better thermal comfort and ventilation performance than that of 30 degree.

고립성 폐결절로 나타난 기관지폐포암의 임상적 고찰 (The Characteristics of Bronchioloalveolar Carcinoma Presenting with Solitary Pulmonary Nodule)

  • 김호철;천은미;서지영;정만표;김호중;권오정;이종헌;한용철;이경수;한정호
    • Tuberculosis and Respiratory Diseases
    • /
    • 제44권2호
    • /
    • pp.280-289
    • /
    • 1997
  • 연구목적 : 기관지폐포암은 다양한 임상적, 방사선적인 양상으로 나타나며 대표적인 방사선적인 양상으로 또는 종괴, 국소적 경화, 미만성 결절 또는 경화 등으로 나타난다. 고립성 결절 또는 국소적 경화 병변으로 나타난 기관지폐포암은 다발성 병변과는 달리 예후가 좋으므로 조기에 진단하는 것이 매우 중요하다. 그러나 고립성 결절로 나타나는 기관지폐포암은 비특이적 임상증상과 다양한 방사선 양상으로 폐렴, 폐결핵, 양성병변으로 오인되어 치료의 시기를 놓치는 경우가 있다. 이에 저자들은 고립성 폐결절로 나타난 기관지폐포암의 임상적, 방사선적 특성을 알아보기 위하여 다음과 같은 연구를 시행하였다. 방 법 : 1995년 1월부터 1996 년 8월까지 서울삼성병원에서 병리학적으로 기관지폐포암이 진단되고 방사선 소견에서 고립성 폐결절로 나타난 환자를 대상으로 임상적, 방사선적인 특성을 조사였다. 결 과 : 환자는 총 11명으로 남자는 6명, 여자 5명이었고 환자들의 연령은 37세에서 69세로 중앙 연령값은 60세이었다. 대부분의 환자는 증상이 없이 단순흉부촬영에서 우연히 이상소견이 발견되어 진단되었다. 단순흉부촬영상 대부분 경계가 불명확한 결절 또는 음영증가의 소견을 보였고 단순흉부촬영후 추측진단 양성병변이나 결핵성 폐병변으로 오인되었던 예가 6예였고 5예에서만 악성 결절로 추정되었다. 전산화단층촬영상 경화, 간유리 모양, 기관지 공기 조영, open bronchus sign, internal bubble-like lucencies, spiculated margin 또는 pleural tag등의 소견이 대부분의 환자에서 관찰되었다. FDG-PET 검사를 시행한 8예중 3예에서 악성을 의심하는 소견이 보였고 5예에서 위음성의 소견을 보였다. 병리학적인 진단은 경기관지폐생검과 경피적 폐생검을, 통해 진단된 예가 각각 1예, 2예이었고 8예에서는 비디오흉강경을 이용한 폐생검을 통해 이루어졌다. 환자는 모두 폐엽절제술을 시행받았고 수술후 병기는 $T_1N_0M_0$가 8예, $T_2N_0M_0$가 3예로 근치적 절제술이 가능하였다. 결 론 : 고립성 결절 양상의 기관지폐포암은 증상 없이 우연히 발견되는 경우가 대부분이며 단순흉부촬영상 주로 경계가 불명확한 결절 또는 음영증가의 소견으로 나타나 양성병변으로 오인되는 경우가 많았다. 만약, 이런 병변이 추적검사에서 계속 남아 있거나 커지는 경우는 흉부전산화단층촬영을 시행하여 경화, 간유리 모양, 기관지 공기조영, internal bubble-like lucencies, spiculated margin 또는 pleural tag등 소견을 보인다면 개흉술 등을 포함한 적극적인 진단적 접근이 필요하다고 생각된다.